AUK SUF623N

SUF623N
Semiconductor
N-Channel Enhancement-Mode MOSFET
Description
• High speed switching application.
Features
•
•
•
•
High density cell design for low RDS(ON).
Voltage controlled small signal switch
Include Zener protection for ESD ruggedness.
Two STK0602 Chips in SOT-26 Package
Ordering Information
Type NO.
Marking
SUF623N
623
Package Code
SOT-26
Outline Dimensions
unit : mm
1.5~1.7
2
4
3
6
Q1
Q2
3
0.4 Typ.
5
2
1
PIN Connections
1. Source 1
2. Gate 2
3. Source 2
4. Drain 2
5. Gate 1
6. Drain1
1~1.2
0.4 Min.
0~0.1
0.11~0.19
5
1
2.8~3.0
6
4
1.88~1.92
0.93~0.97
2.6~3.0
KST-A009-001
1
SUF623N
Absolute maximum ratings (Q1,Q2 Common)
Characteristic
Ta=25°C
Symbol
Rating
Unit
Drain-Source voltage
VDSS
60
V
Gate-Source voltage
VGS
±8
V
Maximum Drain current
ID
200
mA
Pulsed Drain Current
IDP
800
mA
Drain Power dissipation
Operating Junction and
Storage temperature range
PD
200
mW
TJ , Tstg
-55~150
°C
Electrical Characteristics (Q1,Q2 Common)
Characteristic
Symbol
Test Condition
Ta=25°C
Min. Typ. Max.
Unit
Drian-Source breakdown voltage
BVDSS
ID=10µA, VGS=0
60
-
-
V
Gate-Threshold voltage
VGS(th)
ID=1µA, VDS=5V
0.8
-
1.8
V
Zero Gate voltage drain current
IDSS
VDS=60V, VGS=0
-
-
1.0
µA
Gate-body leakage
IGSS
VDS=0V, VGS=±6V
-
-
±1.0
µA
VGS=5V, ID=10mA
-
2.5
6.0
VGS=10V, ID=10mA
-
2.0
4.0
20
65
-
-
26
-
-
20
-
-
10
-
Drain-Source on-resistance
RDS(ON)
Forward transconductance
gfs
Input capacitance
Ciss
Output capacitance
Coss
Reverse Transfer capacitance
Crss
Turn-on delay time
td(on)
Rise time
Turn-off delay time
Fall time
tr
td(off)
VDS=5V, ID=20mA
VDS=5V, VGS=0, f=1MHz
Ω
mS
pF
150
VDD=5V, ID=10mA
VGS=5V
RL=500Ω
tf
KST-A009-001
240
-
200
-
-
300
-
ns
2
SUF623N
Electrical Characteristic Curves
Fig. 1 ID - VDS
Fig. 3 ID - VGS
Fig. 2 ID - VDS
Fig. 4 rDS(on) - ID
Fig. 5 C - VDS
Fig. 6 rDS(on) - TJ
KST-A009-001
3
SUF623N
Electrical Characteristic Curves
Fig. 7 rDS(on) - VGS
Fig. 8 IS - VSD
Fig. 9 VGS(th) - TJ
KST-A009-001
4
SUF623N
These AUK products are intended for usage in general electronic equipments(Office and
communication equipment, measuring equipment, domestic electrification, etc.).
Please make sure that you consult with us before you use these AUK products in equipments which require high quality and/or reliability, and in equipments which could have
major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic
signal, combustion central, all types of safety device, etc.).
AUK cannot accept liability to any damage which may occur in case these AUK products
were used in the mentioned equipments without prior consultation with AUK.
KST-A009-001
5