Issue: 03 Specification AXIS100-03 Oscillator type : VCXO Parameter min. Frequency range Standard frequencies Frequency stability Initial tolerance vs. temperature in operating temperature range (-10°~+60°C) vs. supply voltage variation vs. load change long term (aging) Frequency adjustment range Electronic Frequency Control (EFC) range @ 25°C EFC voltage VC EFC slope (∆f / ∆VC) EFC linearity Control bandwidth RF output Signal waveform Amplitude Harmonics attenuation Subharmonics attenuation Nonarmonics attenuation Supply voltage VS Current consumption (steady state) Operable temperature range Storage temperature range Enclosure (see drawing) LxWxH typ. max. Unit ± 100 ± 100 MHz MHz ppm ppm ppm 38,900 -20 20 ± 60 Date: 2005-06-10 Condition @VC = 0V ppm ppm ppm/year @ 40°C kHz -10 10 negative ±3 V % KHz 30 SINUS +0 30 40 50 11,4 +3 12 12,6 60 -20 +70 -40 +85 36.1x27.2x10.5 max. dBm dBc dBc dBc V mA °C °C mm RL = 50 Ω Similar to IEC 60679-3 CO 09 20 gram Weight bulk IEC 60286-3 Packing 1500 V HBM, IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Ordering Code: Model (Specification) AXIS100-03 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany Frequency [MHz] 38,900 AXIS100-03 page 1(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Enclosure drawing Pin connections Pin # Symbol 1 GND 2 VS 3 VC 4 GND 5 RF OUT Function Ground Supply Voltage Control Voltage (EFC) Ground RF Output Environmental conditions Test IEC 60068 Part ... Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60679-1 clause ... 4.3 2-17 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Bump* 2-29 4.6.6 Free fall* 2-32 4.6.9 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Vibration, sinusoidal* 2-6 4.6.7 Rapid change of temperature Dry heat 2-14 4.6.5 2-2 4.6.14 Damp heat, cyclic* 2-30 4.6.15 Cold 2-1 4.6.16 Climatic sequence* 1-7 4.6.17 Damp heat, steady state* Endurance tests - ageing - extended aging 2-3 4.6.18 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXIS100-03 page 2(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]