AXTAL AXIS100-03

Issue: 03
Specification
AXIS100-03
Oscillator type :
VCXO
Parameter
min.
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature in operating
temperature range (-10°~+60°C)
vs. supply voltage variation
vs. load change
long term (aging)
Frequency adjustment range
Electronic Frequency Control (EFC)
range @ 25°C
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC linearity
Control bandwidth
RF output
Signal waveform
Amplitude
Harmonics attenuation
Subharmonics attenuation
Nonarmonics attenuation
Supply voltage VS
Current consumption (steady state)
Operable temperature range
Storage temperature range
Enclosure (see drawing) LxWxH
typ.
max.
Unit
± 100
± 100
MHz
MHz
ppm
ppm
ppm
38,900
-20
20
± 60
Date: 2005-06-10
Condition
@VC = 0V
ppm
ppm
ppm/year @ 40°C
kHz
-10
10
negative
±3
V
%
KHz
30
SINUS
+0
30
40
50
11,4
+3
12
12,6
60
-20
+70
-40
+85
36.1x27.2x10.5 max.
dBm
dBc
dBc
dBc
V
mA
°C
°C
mm
RL = 50 Ω
Similar to
IEC 60679-3 CO 09
20
gram
Weight
bulk
IEC 60286-3
Packing
1500
V
HBM, IEC 61000-4-2
ESD Sensitivity
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Ordering Code:
Model (Specification)
AXIS100-03
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Frequency [MHz]
38,900
AXIS100-03
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Pin # Symbol
1
GND
2
VS
3
VC
4
GND
5
RF OUT
Function
Ground
Supply Voltage
Control Voltage (EFC)
Ground
RF Output
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIS100-03
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]