AXTAL AXE10-14

Issue: 01
Specification
AXE10-14
Oscillator type :
PXO for WLAN Test Equipment
Parameter
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature in operating frequency
range (steady state)
vs. supply voltage variation
vs. load change
long term (aging) 1st year
Frequency adjustment range
Mechanical (internal trimmer)
Electronic Frequency Control (EFC)
range
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC linearity
EFC input impedance
Absolute pull range (APR) over
10 years, see Note 2
RF output
Signal waveform
Load
Rise & decay time
Symmetry (duty cycle)
Start-up time
Phase noise
@ 63 MHz [100 MHz]
Supply voltage VS
Current consumption (steady state)
Enable/disable function
Operable temperature range
Storage temperature range
Enclosure (see drawing)
Weight
Packing
ESD Sensitivity
min.
typ.
max.
Date: 2004-03-24
Unit
Condition
±2
±5
MHz
MHz
ppm
ppm
ppm
0°~+50°C
±0.2
±0.1
±1
ppm
ppm
ppm
@ 40°C
ppm
ppm
N.A.
N.A.
V
N.A.
22.000 / 40.000
%
kΩ
ppm
ppm
10
HCMOS
15
5
60
4
40
2.85
-45
-55
-95
-125
-135
-140
-145
3.0
3.15
30
+90
+105
14.4x9.5x6 max
3
Tape & reel
1500
pF
ns
%
ms
dBc
dBc
dBc
dBc
dBc
V
mA
°C
°C
mm
gram
V
@ VS/2
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
@ +25°C
IEC 60679-3 or 61837
IEC 60286-3
HBM as in IEC 610004-2
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
GmbH & Co. KG
Wasemweg 5
D-74821 Lobbach
Germany
AXE10-14
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Pin # Symbol
1
N.C.
2
N.C.
3
GND
4
RF OUT
5
N.C.
6
Vs
Function
No Connection
No Connection
Ground
RF Output
No Connection
Supply Voltage
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
2-17
IEC 61178-1
clause ...
4.5
4.6
4.8.2
Test conditions
Enclosure styles as in IEC
60122-3, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Solderability
Resistance to
soldering heat
Shock
2-20
4.8.3
2-27
4.8.8
Bump
2-29
4.8.6
Free fall
2-32
4.8.9
Vibration,
sinusoidal
2-6
4.8.7
Rapid change of
temperature
2-14
4.8.5
Dry heat
2-2
4.8.11
Damp heat, cyclic
2-30
4.8.12
Cold
2-1
4.8.13
Climatic sequence
1-7
4.8.14
Damp heat, steady
state
Endurance tests
- ageing
- extended aging
2-3
4.8.15
Test Ea, 3 x per axes 100g, 6
ms half-sine pulse
Test Eb, 4000 bumps per
Axes, 40g, 6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz
- 2 kHz, 10g
Test Na, 10 cycles at
extremes of operating
temperature range
Test Ba, 16 h at upper
temperature indicated by
climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower
temperature indicated by
climatic category
Sequence of 4.8.11, 4.8.12
st
(1 cycle), 4.8.13, 4.8.12 (5
cycles)
Test Ca, 56 days
4.9.1
4.9.2
30 days @ 85°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Lobbach
Germany
AXE10-14
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]