BEL V7PC

NON-ISOLATED DC/DC CONVERTERS
12V Input / 50% Tracking Output / 10A
V7PC-10AT5 Series
PRELIMINARY
•
Industry standard pinout
•
Designed specifically for Bus Termination voltages
•
Capable of sinking and sourcing current
•
Remote on/off
•
Remote sense
Description
The V7PC-10AT5 is non-isolated step down DC/DC converters that operate from a nominal 12V source. These
converters are designed specifically to provide bus termination voltages in applications such as DDR (double
data rate) memory where the bus termination voltage must closely track the I/O bus voltage. The converter
accepts a reference input and uses this to program its output voltage to 50% of the reference. The unit is
packaged in an industry-standard single-in-line footprint and provides a maximum 10A output. Standard
features include remote on/off, over current protection and remote sense.
Part Selection
Output
Voltage
Vref / 2
Input Voltage
12V
Max. Output
Current
10A
Max. Output
Power
20W
Typical
Efficiency
82%
Model Number
V7PC-10AT5S
Input Specifications
Parameter
Input Voltage Range
Input Reference Voltage
Input Current (no load)
Input Current (full load)
Reflected Ripple Current
Min
10.8VDC
Typ
Max
13.2 VDC
3.5 VDC
Notes
50mA
3.8A
50mA rms
180mA p-p
With a simulated source
impedance of 500nH, 5Hz to
20 MHz
Output Specifications
Parameter
Output Current
Regulation
Setpoint Accuracy
Line Regulation
Load Regulation
Temperature
Ripple and Noise
Min
0A
-1.0%
-0.3%
-0.3%
-0.02%/°C
Typ
Max
10A
+1.0%
+0.3%
+0.4%
+0.02%/°C
100mV pk-pk
25mV rms
Notes
Total error band of ± 3% over
all operating conditions and
temperatures until end of life.
0 to 20MHz Bandwidth
Use 0.1uF ceramic and
470uF aluminum on output
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
NON-ISOLATED DC/DC CONVERTERS
12V Input / 50% Tracking Output / 10A
Output Specifications (continued)
Parameter
Min
Typ
Transient Response
Max deviation
Recovery to within ± 1%
0.5VDC
General Specifications
Pin Connections
Specification
200kHz typical (fixed)
inches
mm
2.50 x 0.55 x 0.36
63.5 x 14.0 x 9.0
inches
mm
0.13 ± 0.02
3.3 ± 0.5
9.5 g
0°C to 70°C (see curve)
-40°C to 100°C
>1,000,000 hours
Pin Length
Weight
Operating Temperature
Non-Operating Temperature
MTBF (MIL-HDBK-217K)
Protection Features
Short circuit
Over current
Undervoltage
Remote On/Off
Notes
di/dt = 1A/uS, Vin =12VDC
Ta = 25°C, 50-100% load
change.
150mV
70uS
Remote Sense Compensation
Parameter
Switching Frequency
Dimensions
Max
Pin
1
2
3
4
5
6
7
8
9
10
11
Function
+Vo
+Vo
Remote Sense (+)
+Vo
Ground
Ground
+Vin
+Vin
No pin
Vref In
Remote ON/OFF
Continuous
130% to 250% max Io
UVLO Vin < 9.8V
Active High
0.025 [0.064]
2002 Bel Fuse Inc. Specifications subject to change without notice. 051502
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com