Cree® P4 LED Model # LP377TYL1-40G Data Sheet 40-degree, 7.6 x 7.6 mm LED lamp in amber color with water-transparent lens and stopper Applications • • • • Advertising Signs Indicators Traffic Signals Automotive Lighting Absolute Maximum Ratings (TA = 25°C) Items Symbol Absolute Maximum Rating Unit IF 70 mA IFP 200 mA Reverse Voltage VR 5 V Power Dissipation PD 220 mW Operation Temperature Topr -40 ~ +100 °C Storage Temperature Tstg -40 ~ +100 °C Lead Soldering Temperature Tsol Forward Current Note 2 Peak Forward Current Note 1 Max. 260°C for 3 sec. max. (3 mm from the base of the epoxy bulb) Notes: 1. 2. Pulse width ≤0.1 msec, duty ≤1/10. A heat sink is recommended if the device is operated at ambient temperatures higher than 25°C. D-CT132.000 Data Sheet: CL Typical Electrical & Optical Characteristics (TA = 25°C) Characteristics Symbol Condition Forward Voltage VF IF = 70 mA V Reverse Current IR VR = 5 V μA Dominant Wavelength λD IF = 70 mA nm 584 591 ΦV IF = 70 mA mlm 2000 3200 2θ½ IF = 70 mA deg Luminous Flux 50% Power Angle Unit Minimum Subject to change without notice. www.cree.com/ledlamps Typical 2.6 Maximum 3.2 100 599 40 Standard Bins for LP377TYL1-40G (IF = 70 mA) Lamps are sorted to luminous flux (ΦV), VF and dominant wavelength (λD) bins shown. Orders for LP377TYL1-40G may be filled with any or all bins contained as below. All luminous flux (ΦV), VF and dominant wavelength (λD) values shown and specified are at IF = 70 mA. X2 X3 X4 X5 X6 L or above K J H G 584 nm 587 nm 590 nm 596 nm 593 nm 599 nm Dominant Wavelength (λD) Rank Luminous Flux G H J K 2000-3000 mlm 2500-3600 3000-4200 mlm 3500-4800 mlm Forward Voltage (VF) Rank Voltage V4 V5 V6 V7 V8 2.2-2.4 V 2.4-2.6 V 2.6-2.8 V 2.8-3.0 V 3.0-3.2 V Important Notes: 1. All ranks will be included per delivery; rank ratio will be based on the dice distribution. 2. No tolerance of measurement of luminous flux. 3. Tolerance of measurement of dominant wavelength is ±1 nm. 4. Tolerance of measurement of VF is ±0.05 V. 5. Packaging methods are available for selection; please refer to the “Cree LED Lamp Packaging Standard” document. 6. Please refer to the “Cree LED Lamp Reliability Test Standards” document for reliability test conditions. 7. Please refer to the “Cree LED Lamp Soldering & Handling” document for information about how to use this LED product safely. Copyright © 2007 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the Cree logo are registered trademarks of Cree, Inc. CLD-CT132.000 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps Model No. Doc. No. LP377TYL1-40G 12 23Sep04 Graphs Graphs 100.0 If (mA) -50 -60 Vr(V) -40 -30 -20 -10 0.0 80.0 -10.0 60.0 -20.0 40.0 -30.0 20.0 -40.0 Vf(V) 0.0 2.0 -50.0 Ir(uA) FIG.2 REVERSE CURRENT VS. 2.2 2.4 2.6 2.8 3.0 FIG.1 FORWARD CURRENT VS. FORWARD VOLTAGE. REVERSE VOLTAGE. Half Power WL=20nm Domi WL= 591nm I (RELATIVE LUMINOUS FLUX) 100% 2.5 2.0 75% 1.5 50% 1.0 25% 0.5 WL(nm) 500 600 700 800 900 FIG.4 RELATIVE LUMINOUS FLUX VS. WAVELENGTH. 0% 400 If(mA) 0.0 0.0 20.0 40.0 60.0 80.0 100.0 FIG.3 RELATIVE LUMINOUS FLUX VS. FORWARD CURRENT. 100 IF(mA) 50% Power Angle : 40 Ie(%) 80 0 100% 60 80% 40 60% 20 0 40% Ta( C) 0 20 40 60 80 100 FIG.5 MAXIMUM FORWARD DC CURRENT VS AMBIENT TEMPERATURE (Tjmax=120 C) Items 20% 120 Signatures Date Prepared by LiuZM 2004/09/23 DOC. No. Checked by AldosinLi 2004/09/23 J 16Jul03 Approved by David 2004/09/23 K 11Nov03 ECN# ECN-H20040261 0% -90 -60 -30 0 60 30 90 FIG.6 FAR FIELD PATTERN Revision History 12 23Sep04 CHANGE DESCRIPTION Cancel VF(min). add V8 & X6 PD from 150 to 220; Change FIG.5 Add ESD and Notes; Change FIG.1&3&5; Change ĭV & OD Rank form. Data is subject to change without prior notice. Copyright@2002 Cotco International Ltd. Obsoletes Doc: K 11Nov03. Copyright © 2007 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the Cree logo are registered trademarks of Cree, Inc. CLD-CT132.000 4/4 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps COTCO-D-074 REV.1 Mechanical Dimensions Model No. LP377TYL1-40G Doc. No. 12 23Sep04 All dimensions are in mm. Tolerance is ±0.25 mm unless otherwise noted. An epoxy meniscus may extend about 1.5 mm down the leads. Dimension Drawing Burr around bottom of epoxy may be 0.5 mm max. maximum ating Unit 70 mA 00 mA 5 V 20 mW ~ +100 °C ~ +100 °C 0°C forNotes 5 sec Max. e base of the epoxy bulb) RoHS Compliance The levels of environmentally sensitive, persistent biologically toxic (PBT), persistent organic pollutants (POP), or the device is operated at ambient temperatures higher than 25 deg C. For long term otherwise restricted materials in this product are below the maximum concentration values (also referred to as the threshold permitted forPlease such substances, or are usedsales in an representative exempted application, in accordance with EU Direcand 50mA are limits) recommended. contact COTCO for more tive 2002/95/EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS), as amended through April 21, 2006. Vision Advisory Claim = 25should °C) be cautioned not to stare at the light of this LED product. The bright light can damage the eye. cs ( TaUsers Condition Min. Typ. Max. Unit Copyright © 2007 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the IF = 70mA --- of Cree, Inc. 2.6 3.2 V Cree logo are registered trademarks CLD-CT132.000 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps Kit Number System Cree LED lamps are tested and sorted into performance bins. A bin is specified by ranges of color, forward voltage, and brightness. Sorted LEDs are packaged for shipping in various convenient options. Please refer to the “Cree LED Lamp Packaging Standard” document for more information about shipping and packaging options. Cree LEDs are sold by order codes in combinations of bins called kits. Order codes are configured in the following manner: Standard/Custom 0: Standard C: Custom VF 0: Full forward voltage distribution 1~9, A~Z . . . : special request * Wd/Color 1: Full-color distribution 2~9, A~Z . . . : special request * aaaaaaaaa-aaa-aa- x x x x x IV 0: Full luminous intensity distribution 1~9, A~Z . . . : special request * Packing type 0: Standard = tube pack 1~9, A~Z . . . : special request * Product P/N * Contact your Cree sales representative for ordering information. Standard Available Kits* Kit Number Description LP377TYL1-40G-00001 P4 40 Amber 591nm, FULL RANK, Tube Pack LP377TYL1-40G-00011 P4 40 Amber 591nm, H or above, Tube Pack * Please contact your Cree representative about the availability of non-standard kits. Copyright © 2007 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the Cree logo are registered trademarks of Cree, Inc. CLD-CT132.000 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 Fax: +1.919.313.5778 www.cree.com/ledlamps