CUI CSEX-X-OL

CSEX-X-OL Series
Date: 5/29/07
Unit: mm
current sensor
Page No: 1 / 2
Features
· RoHS Compliant
· Low insertion losses
· Easy mounting
· Small size and space saving
· High immunity to external interference
Models
Model
CSE100-300-OL
Nominal
Output
R.M.S
Voltage 1,2
Current 1
100 mV ±15% @±I PN 100 A
Current
Measuring
Range 1
0 ~ ±300
Supply
Voltage 1
4 V ±5%
Current
Offset
Consumption 1
Voltage 1
±5.85 mA
±7 mV @I P =0
Notes:
1. AT = 25°C.
2. R L = 10 KΩ
Operating Performance
Thermal drift of V O
Thermal drift of V OUT
Response time
Linearity
Accuracy
Hysteresis offset voltage
Isolation voltage
Frequency bandwidth
±0.5 mV/°C
0.04%/°C
5µs
2% @0~±I PN
±15% @I PN
±10 mV @±I PN →0
3 KV @ 50/60 Hz for 1 minute
0 ~ 50 KHz
General Data
Operating temperature
Storage temperature
Mass
Setup Diagram
-25 ~ +85°C
-40 ~ +100°C
6.5g
Current direction
POWER SUPPLY
-
VOLTMETER
+
-
1
Phone: 800.275.4899
Fax: 503.612.2381
4
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
REV.
A
DESCRIPTION
NEW DRAWING
DATE
5/29/2007
7.0 0.276
0.15
10.0
+0.0
-0.2
17.0 0.669
0.18
13.0 0.512
MAX (TYP)
0.4 0.016
0.1 (4 PLCS)
3.0 0.118
0.2
0.25 0.010
0.1 (4 PLCS)
RoHS
TOLERANCE:
±0.2mm UNLESS OTHERWISE
SPECIFIED
1
2
3
4
20050 SW 112th Ave.
Tualatin, OR 97062
Phone: 503-612-2300
800-275-4899
Fax: 503-612-2383
Website: www.cui.com
Secondary Terminals
PC FILE NAME:
CSEX-X-OL Series
COPYRIGHT 2007 BY CUI INC.
Terminal 1
Terminal 2
+VCC
+OUTPUT
Terminal 3
Terminal 4
GND
-OUTPUT
TITLE:
REV:
CURRENT SENSOR
PART NO.
CSEX-X-OL Series
DRAWN BY:
ZRJ
APPROVED BY:
A
UNITS:
MM [INCHES]
SCALE:
2:1