LEM HAC600-S

Current Transducers HAC 100 ... 800-S
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 100 .. 800 A
Preliminary
Electrical data
Primary nominal
r.m.s. current
IPN (A)
Primary current
measuring range
IP (A)
100
200
300
400
600
800
VC
IC
± 300
± 600
± 900
± 900
± 1800
± 1800
Type
HAC 100-S
HAC 200-S
HAC 300-S
HAC 400-S
HAC 600-S
HAC 800-S
Features
• Hall effect measuring principle
• Galvanic isolation between primary
Supply voltage (± 5 %)
Current consumption
± 15
HAC 100-S .. 400-S
< ± 18
HAC 600-S .. 800-S
< ± 25
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn 2.5
Isolation resistance @ 500 VDC
> 1000
Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C
±4
Output internal resistance
100
Load resistance
>10
Vd
RIS
VOUT
ROUT
RL
V
mA
mA
kV
MΩ
V
Ω
kΩ
and secondary circuit
• Isolation voltage 2500 V
• Low power consumption
• Extended measuring range (3 x IPN)
Advantages
• Easy mounting
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
interference.
Accuracy - Dynamic performance data
X
ε
L
VOE
VOH
VOT
TCε G
tr
f
Accuracy @ IPN, TA = 25°C (without offset)
Linearity (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN
Thermal drift of VOE
Thermal drift (% of reading)
Response time @ 90% of IP
Frequency bandwidth (- 3 dB)1)
< ± 1 % of IPN
< ± 1 % of IPN
< ± 30
mV
< ± 35
<±1
< ± 0.1
<7
DC .. 50
mV
mV/K
%/K
µs
kHz
Applications
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
applications.
- 10 .. + 80
- 15 .. + 85
70
°C
°C
g
Notes : EN50178 approval pending
1)
Derating is needed to avoid excessive core heating at high frequency.
010118/2
LEM Components
www.lem.com
HAC 100 ... 800-S
Top View
20
d 4.5
Molex 5045-04AG
18
7.5
10
28
4321
42
Front View
1
9
23
34
24
16
Left View
21
4.5
20
d 2.5
58
Terminal Identification
1.....+Vcc
2.....-Vcc
3.....Output
4.....0V
mm
TOLERANCE : +/-0.5
UNLESS OTHERWISE SPECIFIED
UNIT : mm
SCALE : 1/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.