CUI VPOL15A-5-SMT

rev.
PART NUMBER: VPOL15A-5-SMT
page
1 of 11
date
08/2007
DESCRIPTION: point of load converter
features
* industry standard pin out
* high efficiency to 94%
* 300 KHz switching frequency
* 3.0-5.5 VDC input range
* 0.9-3.63 VDC wide output range
* over temperature protection
* continuous short circuit protection
* remote on/off
* cost-efficient open frame design
* UL/C-UL60950 (E222736) certified
1. INTRODUCTION
2. VPOL15A-5-SMT CONVERTER FEATURES
3. GENERAL DESCRIPTION
7. APPLICATIONS
3.1 Electrical Description
7.3 Thermal Considerations
3.2 Thermal Packaging and Physical Design.
7.4 Power De-Rating Curves
4. TECHNICAL SPECIFICATIONS
5. MAIN FEATURES AND FUNCTIONS
7.5 Efficiency vs Load Curves
7.6 Input Capacitance at the Power Module
5.1 Operating Temperature Range
7.7 Test Set-Up
5.2 Over-Temperature Protection (OTP)
7.8 Remote Sense Compensation
5.3 Output Voltage Adjustment
7.9 VPOL15A-5-SMT Series Output Voltage Adustment.
5.4 Safe Operating Area (SOA)
7.10 Output Ripple and Noise Measurement
5.5 Over Current Protection
7.11 Output Capacitance
5.6 Remote on/off
7.12 VPOL15A-5-SMT Reflow Profile
5.7 UVLO (Under-Voltage Lockout)
8. MECHANICAL OUTLINE DIAGRAMS
6. SAFETY
8.1 VPOL15A-5-SMT Mechanical Outline Diagrams
6.1 Input Fusing and Safety Considerations.
8.2 VPOL15A-5-SMT Tape and Reel Dimensions
7.1 Layout Design Challenges.
7.2 Convection Requirements for Cooling
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
PART NUMBER: VPOL15A-5-SMT
page
2 of 11
date
08/2007
DESCRIPTION: point of load converter
1. Introduction
The converter is also protected against over-temperature conditions. If
This application note describes the features and functions of V-Infinity’s
the converter will shut down to protect the unit.
the converter is overloaded or the ambient temperature gets too high,
VPOL15A-5-SMT series of non-isolated dc-dc converters. These are
highly efficient, reliable and compact, high power density, single output
L1
Q1
+VIN
+VO
dc-dc converters. These “Point of Load” modules serve the needs
specifically of the fixed and mobile telecommunications and computing
Q2
C1
market, employing economical distributed power architectures. The
D1
C2
R sense
VPOL15A-5-SMT series provide precisely regulated output voltage
+SENSE
range from 0.9V to 3.63Vdc over a wide range of input voltage (Vi=3.0 –
5.5Vdc) and can operate over an ambient temperature range of –40°C
COM
COM
to +85°C. Ultra-high efficiency operation is achieved through the use of
R1
synchronous rectification and drive control techniques.
The modules are fully protected against short circuit and over-
PWM IC
ON/OFF
R trim
TRIM
ERR AMP
temperature conditions. V-Infinity’s world class automated
R2
manufacturing methods, together with an extensive testing and
qualification program, ensure that all VPOL15A-5-SMT series
Figure 1. Electrical Block Diagram
converters are extremely reliable.
2. VPOL15A-5-SMT Converter
Features
3.2 Thermal Packaging and Physical Design.
The VPOL15A-5-SMT series uses a multi-layer FR4 PCB construction.
All surface mount power components are placed on one side of the
PCB, and all low-power control components are placed on the other
High efficiency topology, typically 94% at 3.3Vdc
side. Thus, the heat dissipation of the power components is optimized,
Industry standard footprint
ensuring that control components are not thermally stressed. The
Wide ambient temperature range, -40°C to +85°C
converter is an open-frame product and has no case or case pin. The
Cost efficient open frame design
open-frame design has several advantages over encapsulated closed
Programmable output voltage via external resistor from 0.9 to
devices. Among these advantages are:
3.63Vdc
No minimum load requirement (Stable at all loads)
Efficient Thermal Management: the heat is removed from the
Remote on/off
heat generating components without heating more sensitive, small
Remote sense compensation
signal control components.
Fixed switching frequency
Environmental: Lead free open-frame converters are more easily
Continuous short-circuit protection and over current protection
re-cycled.
Over-temperature protection (OTP)
Cost Efficient: No encapsulation. Cost efficient open-frame
Monotonic Startup with pre-bias at the output.
construction.
UL/IEC/EN60950 Certified.
Reliable: Efficient cooling provided by open frame construction
offers high reliability and easy diagnostics.
3. General Description
3.1 Electrical Description
A block diagram of the VPOL15A-5-SMT Series converter is shown in
Figure 1. Extremely high efficiency power conversion is achieved
through the use of synchronous rectification and drive techniques.
Essentially, the powerful VPOL15A-5-SMT series topology is based on
a non-isolated synchronous buck converter. The control loop is
optimized for unconditional stability, fast transient response and a very
tight line and load regulation. In a typical pre-bias application the
VPOL15A-5-SMT series converters do not draw any reverse current at
start-up. The output voltage can be adjusted from 0.9 to 3.63vdc, using
the TRIM pin with a external resistor. The converter can be shut down
via a remote on/off input that is referenced to ground. This input is
compatible with popular logic devices; a 'positive' logic input is supplied
as standard. Positive logic implies that the converter is enabled if the
remote on/off input is high (or floating), and disabled if it is low.
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
page
3 of 11
date
08/2007
DESCRIPTION: point of load converter
PART NUMBER: VPOL15A-5-SMT
4. Technical Specifications
(All specifications are typical at nominal input, full load at 25°C unless otherwise noted.)
PARAMETER
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Continuous
Operating Temp erature
See Thermal Considerations Section
NOTES and CONDITIONS
Device
Min.
Typical Max.
Units
ALL
0
5.8
Vdc
ALL
-40
+85
°C
ALL
-55
+125
°C
ALL
3.0
4.5
5.5
5.5
Vdc
Storage Temperature
INPUT CHARACTERISTICS
Operating Input Voltage
Vo=2.7V
Vo=3.0V
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Hysteresis Voltage
Maximum Input Current
Vin=3.0 to 5.5Vdc , Io=Io,max.
No-Load Input Current
Vo=1.0V
Vo=1.2V
Vo=1.5V
Vo=1.8V
Vo=2.0V
Vo=2.5V
Vo=3.3V
Off Converter Input Current
Shutdown input idle current
ALL
ALL
ALL
ALL
5.0
5.0
Vdc
Vdc
Vdc
2.8
2.7
0.1
15.5
60
60
60
70
70
70
70
ALL
ALL
5
A
mA
10
mA
0.4
As
Inrush Current (I t)
ALL
Input Reflected-Ripple Current
P-P thru 1uH inductor, 5Hz to 20MHz
ALL
150
mA
Output Voltage Set Point
Vin=Nominal Vin , Io=Io.max, Tc=25°C
ALL
-1.5% Vo,set +1.5%
Vdc
Output Voltage Trim Adjustment Range
Selected by an external resistor
ALL
0.9
3.63
Vdc
Load Regulation
Io=Io.min to Io.max
ALL
-0.5
+0.5
%
Line Regulation
Vin=low line to high line
-0.2
-0.4
+0.2
+0.4
%
±0.03
%/°C
2
2
OUTPUT CHARACTERISTIC
Output Voltage Regulation
Tempera ture Coefficient
Ta=-40°C to 85°C
Output Voltage Ripple and Noise
5Hz to 20MHz bandwidth
VPOL15A-5SMT
ALL
Peak-to-Peak
Full Load, 1uF ceramic and 10uF tantalum
ALL
50
mV
RMS
Full Load, 1uF ceramic and 10uF tantalum
ALL
20
mV
Low ESR
ALL
10000
uF
ALL
0
Output DC Current-Limit Inception
Output Voltage =90% Nominal Output Voltage
ALL
18
Shout Circuit Protection
Continuous with Hiccup Mode
External Capacitive Load
Operating Output Current Range
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
22
15
A
28
A
rev.
4 of 11
date
08/2007
DESCRIPTION: point of load converter
PART NUMBER: VPOL15A-5-SMT
PARAMETER
DYNAMIC CHARACTERISTICS
page
NOTES and CONDITIONS
Device
Min.
Typical Max.
Units
Output Voltage Transient Response
Error Brand
25% Step Load Change, di/dt=0.1A/us
ALL
Setting Time (within 1% Vout nominal)
25% Step Load Change, di/dt=0.1A/us
ALL
±5
%
200
us
EFFICIENCY
100% Load
Vo=1.0V
Vo=1.2V
Vo=1.5V
Vo=1.8V
Vo=2.0V
Vo=2.5V
Vo=3.3V
82
84
87
88
89
92
94
ALL
%
ISOLATION CHARACTERISTICS
Input to Output
Non-isolation
0
Vdc
FEATURE CHARACTERISTICS
Switching Frequency
on/off Control, Positive Logic Remote On/Off
Logic Low (Module Off)
Logic High (Module On)
on/off Control, Negative Logic Remote On/Off
Logic Low (Module On)
Logic High (Module Off)
on/off Current (for both remote on/off logic)
Leakage Current (for both remote on/off logic)
Turn-On Delay and Rise Time
Turn-On Delay Time, From On/Off Control
Turn-On Delay Time, From Input
Output Voltage Rise Time
Over Temperature Protection
300
ALL
0
0.4
Vin
Vdc
Vdc
ALL
0
2.8
0.4
Vin
Vdc
Vdc
1
1
mA
mA
or Open Circuit
or Open Circuit
KHz
Ion/off at Von/off=0.0V
Logic High, Von/off=5V
Von/off to 10%Vo,set
Vin,min. to 10%Vo,set
10%Vo,set to 90%Vo,set
1
1
3.5
120
Io=100%of Io.max;Ta=25 °C per MIL-HDBK-217F
1.5
6.8
6
ms
ms
ms
°C
GENERAL SPECIFICATIONS
MTBF
Weight
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
M hours
grams
rev.
page
5 of 11
date
08/2007
DESCRIPTION: point of load converter
PART NUMBER: VPOL15A-5-SMT
current protection. The unit operates normally once the fault condition is
5. Main Features and Functions
removed. The power module will supply up to 150% of rated current. In
the event of an over current converter will go into a hiccup mode
5.1 Operating Temperature Range
protection.
V-Infinity’s VPOL15A-5-SMT series converters highly efficient converter
5.6 Remote On/Off
design has resulted in its ability to operate over a wide ambient
The remote on/off input feature of the converter allows external circuitry
temperature environment ( -40°C to 85°C). Due consideration must be
to turn the converter on or off. Active-high remote on/off is available as
given to the de-rating curves when ascertaining maximum power that can
standard. The VPOL15A-5-SMT series converters are turned on if the
be drawn from the converter. The maximum power drawn is influenced
remote on/off pin is high, or left open or floating. Setting the pin low will
by a number of factors, such as:
turn the converter ‘Off’. The signal level of the remote on/off input is
defined with respect to ground. If not using the remote on/off pin, leave
Input voltage range.
the pin open (module will be on). The part number suffix “N” is negative
Output load current.
Air velocity (forced or natural convection).
Mounting orientation of converter PCB with respect to the airflow.
Motherboard PCB design, especially ground and power planes.
These can be effective heat sinks for the converter.
remote on/off version. The unit is guaranteed off over the full temperature
range if this voltage level exceeds 2.8Vdc. The converters are turned on
If the on/off pin input is low or left open. The recommended VPOL15A-5SMT remote on/off drive circuit is shown as figures 3 & 4.
5.2 Over-Temperature Protection (OTP)
The VPOL15A-5-SMT series converters are equipped with non-latching
over-temperature protection. A te mperature sensor monitors the
temperature of the hot spot (typically, top switch). If the temperature
exceeds a threshold of 120°C (typical) the converter will shut down,
disabling the output. When the temperature has decreased the converter
will automatically restart.
The over-temperature condition can be induced by a variety of reasons
such as external overload condition or a system fan failure.
5.3 Output Voltage Adjustment
Section 7.9 describes in detail as to how to trim the output voltage with
respect to its set point. The output voltage on all models is trimmable in
the range 0.9 – 3.63Vdc.
5.4 Safe Operating Area (SOA)
Figure 2 provides a graphical representation of the safe operating area
(SOA) of the converter. This representation assumes ambient operating
conditions such as airflow are met as per thermal guidelines provided in
Sections 7.2 and 7.3.
Vo
VOLTAGE (V)
Vo,nom
Safe Operating Area
Io,max Io,CL Io
CURRENT (A)
Figure 2. Maximum Output Current Safe Operating Area
5.5 Over Current Protection
All different voltage models have a full continuous short-circuit protection.
The unit will auto recover once the short circuit is removed. To provide
protection in a fault condition, the unit is equipped with internal over-
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
+Vin
+Vo
date
08/2007
7. Applications
7.1 Layout Design Challenges.
Remote ON/OFF
In optimizing thermal design the PCB is utilized as a heat sink. Also
Q1
VPOL15A-5-SMT
Common
6 of 11
DESCRIPTION: point of load converter
PART NUMBER: VPOL15A-5-SMT
ON/OFF
Control
page
Common
some heat is transferred from the VPOL15A-5-SMT module to the main
board through connecting pins. The system designer or the end user
must ensure that other components and metal in the vicinity of the
VPOL15A-5-SMT series meet the spacing requirements to which the
system is approved.
Figure 3. Positive Remote on/off Input Drive Circuit
Low resistance and low inductance PCB layout traces are the norm and
should be used where possible. Due consideration must also be given to
+Vin
+Vo
proper low impedance tracks between power module, input and output
grounds. The recommended VPOL15A-5-SMT footprint is shown as
Q1
VPOL15A-5-SMT
ON/OFF
Control
figure 5.
Remote ON/OFF
Common
Common
Recommended Pad Layout
Dimensions are in millimetes and(inches)
Figure 4. Negative Remote on/off Input Drive Circuit
7.54
(0.297)
5.7 UVLO (Under-Voltage Lockout)
4.83
4.83
4.83
(0.190) (0.190) (0.190)
7.87
(0.310)
The voltage on the Vcc pin determines the start of the operation of the
+SENSE TRIM
Converter. When the input Vcc rises and exceeds about 2.8V the
converter initiates a soft start. The UVLO function in the converter has a
10.29
(0.405)
+VO
COM
ON/OFF
0.64
(0.025)
6. Safety
6.1 Input Fusing and Safety Considerations.
Agency Approvals: The power supply shall be submitted to and receive
formal approval from the following test agencies.
10.92
(0.430)
Top View of Board
hysteresis (about 100mV) built in to provide noise immunity at start-up.
+VIN
29.90
(1.177)
PAD SIZE
MIN:3.556x2.413(0.140x0.095)
MAX:4.19x2.79(0.165x0.110)
Figure 5. Recommended VPOL15A-5-SMT Footprint
1.The power supply shall be approved by a nationally recognized testing
rd
laboratory to UL/CSA 60950 3 Edition (North America) and EN60950
(International)
2. CB Certificate from an internationally recognized test house in
accordance with EN 60950.
The VPOL15A-5-SMT series converters do not have an internal fuse.
However, to achieve maximum safety and system protection, always
use an input line fuse. The safety agencies require a time-delay fuse
with a maximum rating of 20A.
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
TYPICAL POWER DERATING FOR 5 Vin 3.3 Vout
SMT15-05S33A Derating Curve
16
14
Output Current(A)
12
10
0LFM
6
100LFM
4
200LFM
2
0
0
10
20
30
40
50
60
70
Ambient Temperature( oC)
7 of 11
date
08/2007
DESCRIPTION: point of load converter
PART NUMBER: VPOL15A-5-SMT
8
page
80
90
100
NOTE:
1. specific input & output derating curves available, please
contact V-Infinity for detail
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
page
8 of 11
date
08/2007
DESCRIPTION: point of load converter
PART NUMBER: VPOL15A-5-SMT
7.5 Efficiency vs Load Curves (Fig. 10)
VPOL15A-5-SMT Vo=3.3V (Eff Vs Io)
VPOL15A-5-SMT Vo=2.5V (Eff Vs Io)
95%
95%
90%
85%
4.5V
5.0V
5.5V
80%
75%
Efficincy (%)
100%
Efficincy (%)
100%
90%
85%
3.0V
5.0V
5.5V
80%
75%
70%
70%
0
1
2
3
4
5
6
7
8
0
9 10 11 12 13 14 15
1
2
3
4
95%
90%
85%
3.0V
5.0V
5.5V
Efficincy (%)
95%
Efficincy (%)
100%
75%
7
8
9 10 11 12 13 14 15
90%
85%
3.0V
5.0V
5.5V
80%
75%
70%
70%
0
1
2
3
4
5
6
7
8
0
9 10 11 12 13 14 15
1
2
3
4
VPOL15A-5-SMT Vo=1.2V (Eff Vs Io)
95%
95%
90%
90%
85%
80%
3.0V
5.0V
5.5V
65%
60%
Efficincy (%)
100%
70%
6
7
8
9 10 11 12 13 14 15
VPOL15A-5-SMT Vo=1.0V (Eff Vs Io)
100%
75%
5
Current Load (A)
Current Load (A)
Efficincy (%)
6
VPOL15A-5-SMT Vo=1.5V (Eff Vs Io)
VPOL15A-5-SMT Vo=1.8V (Eff Vs Io)
100%
80%
5
Current Load (A)
Current Load (A)
85%
80%
75%
3.0V
5.0V
5.5V
70%
65%
60%
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
Current Load (A)
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
Current Load (A)
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
page
9 of 11
date
08/2007
DESCRIPTION: point of load converter
PART NUMBER: VPOL15A-5-SMT
VNL is the output voltage at no load
7.6 Input Capacitance at the Power Module
The VPOL15A-5-SMT converters must be connected to a low AC
The value of line regulation is defined as:
source impedance. To avoid probl ems with loop stability source
inductance should be low. Also, the input capacitors should be placed
Line.reg =
close to the converter input pins to de-couple distribution inductance.
However, the external input capacitors are chosen for suitable ripple
Where: VHL is the output voltage of maximum input voltage at full load.
handling capability. Low ESR polymers are a good choice. They have
VLL is the output voltage of minimum input voltage at full load.
high capacitance, high ripple rating and low ESR (typical <20mohm).
Current Meter
Electrolytic capacitors should be avoided. Circuit as shown in Figure 11
A
A
+Vo
+Sense
Power +
of 1uH. Current is measured at the input of the module.
Supply
+
Voltage
V 100uF
Meter
Tant.
VPOL15A-5-SMT
Common
To Oscilloscope
Voltage Meter
V
R-Load
Common
Figure 12. VPOL15A-5-SMT Series Test Setup
L1
+Vin
1uH
Power
Current Meter
+Vin
represents typical measurement methods for ripple current. Input
reflected-ripple current is measured with a simulated source Inductance
VHL _ VLL
x 100%
VLL
7.8 Remote Sense Compensation
Remote sense regulates the output voltage at the point of load. It
+
2*100uF
Tantalum
Supply
VPOL15A-5-SMT
220uF
ESR<0.1ohm
minimizes the effects of distribution losses such as drops across the
connecting pin and PCB tracks (see Figure 13). Please note however,
the maximum drop from the output pin to the point of load should not
exceed 500mV for remote compensation to work.
Common
The amount of power delivered by the module is defined as the output
voltage multiplied by the output current (VO x IO).
When using “Trim Up”, the output voltage of the module will increase
Figure 11. Input Reflected-Ripple Test Setup
which, if the same output current is maintained, increases the power
7.7 Test Set-Up
output by the module. Make sure that the maximum output power of the
The basic test set-up to measure parameters such as efficiency and
module remains at or below the maximum rated power.
load regulation is shown in Figure 12. Things to note are that this
When the remote sense feature is not being used, leave sense pin
converter is non-isolated, as such the input and output share a common
disconnected.
ground. These grounds should be connected together via low
impedance ground plane in the application circuit. When testing a
Figure 13. Circuit Configuration for Remote Sense Operation
converter on a bench set-up, ensure that -Vin and -Vo are connected
together via a low impedance short to ensure proper efficiency and load
regulation measurements are being made. When testing the V-Infinity’s
VPOL15A-5-SMT series under any transient conditions please ensure
Distribution Losses
that the transient response of the source is sufficient to power the
equipment under test. We can calculate the
+Vin
Efficiency
+Sense
Load regulation and line regulation.
The value of efficiency is defined as:
ç=
Where:
Vo x Io
x 100%
Vin x Iin
+Vo
R-Load
VPOL15A-5-SMT
Common
Common
Distribution Losses
Vo is output voltage,
Io is output current,
Vin is input voltage,
Iin is input current.
The value of load regulation is defined as:
Load .reg =
Where:
VFL _ VNL
x 100%
VNL
VFL is the output voltage at full load
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
page
10 of 11
date
08/2007
DESCRIPTION: point of load converter
PART NUMBER: VPOL15A-5-SMT
7.9 VPOL15A-5-SMT Series Output Voltage
Adustment.
7.10 Output Ripple and Noise Measurement
The test set-up for noise and ripple measurements is shown in Figure
The output voltage of the VPOL15A-5-SMT can be adjusted in the
15. a coaxial cable with a 50ohm termination was used to prevent
range 0.9V to 3.63V by connecting a single resistor on the motherboard
impedance mismatch reflections disturbing the noise readings at higher
(shown as Rtrim) in Figure 14. When trim resistor is not connected the
frequencies.
output voltage defaults to 0.75V
+Vin
+Vo
+Vin
Trim
1uF
Ceramic
R-Load
Test Jack
R trim-up
Common
10uF
Tant.
VPOL15A-5-SMT
R-Load
VPOL15A-5-SMT
+Vo
Common
Common
Common
Figure 15. Output Voltage Ripple and Noise Measurement Set-Up
Figure 14. Trim-up Voltage Setup
7.11 Output Capacitance
V-Infinity’s VPOL15A-5-SMT series converters provide unconditional
The value of Rtrim-up defined as:
stability with or without external capacitors. For good transient response
Rtrim = (
Where:
21070 _
5110 )
Vo _ 0.75
low ESR output capacitors should be located close to the point of load.
For high current applications point has already been made in layout
considerations for low resistance and low inductance tracks.
Rtrim-up is the external resistor in ohm,
Output capacitors with its associated ESR values have an impact on
Vo is the desired output voltage
loop stability and bandwidth. V-Infinity’s converters are designed to
To give an exa mple of the above calculation, to set a voltage of 3.3Vdc,
work with load capacitance up-to 10,000uF. It is rec ommended that any
Rtrim is given by:
additional capacitance, typically 1,000uF and low ESR (<20mohm), be
connected close to the point of load and outside the remote
21070 _
Rtrim = ( _
5110 )
Vo 0.75
compensation point.
7.12 VPOL15A-5-SMT Reflow Profile
An example of the VPOL15A-5-SMT reflow profile is given in Figure 16.
Equipment used: SMD HOT AIR REFLOW HD-350SAR
Rtrim = 3153 ohm
Alloy: AMQ-M293TA or N C-SMQ92 IND-82088 SN63
For various output values various resistors are calculated and provided
REFLOW PROFILE
in Table 3 for co nvenience.
Rtrim (Kohm)
135.36
79.17
41.71
22.98
14.96
11.75
6.93
3.15
2.20
Table 3 – Trim Resistor Values
200
TEMPERATURE (C)
Vo,set (V)
0.90
1.00
1.20
1.50
1.80
2.00
2.50
3.30
3.63
240
160
120
80
40
0
0
30
60
90
120 150 180 210 240
TIME (SECONDS)
Figure 16 VPOL15A-5-SMT Reflow Profile
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
page
11 of 11
date
08/2007
DESCRIPTION: point of load converter
PART NUMBER: VPOL15A-5-SMT
8. Mechanical Outline Diagrams
8.2 VPOL15A-5-SMT Tape and Reel Dimensions
The tape reel dimensions for the VPOL15A-5-SMT module are shown
8.1 VPOL15A-5-SMT Mechanical Outline Diagrams
in Figure 18.
Dimensions are in millimeters and inches
Tolerance: x.xx ±0.02 in. (0.5mm) , x.xxx ±0.010 in. (0.25 mm) unless
otherwise noted
P
D
t
E
BOTTOM VIEW OF BOARD
9.30
(0.366)
max.
33.0
(1.30)
7.87
(0.310)
4.83
4.83
4.83
(0.190) (0.190) (0.190)
COM
+VO
W
Bo
F
Po
P2
7.54
1.65
(0.065)
(0.297)
Ao
Ko
TRIM +SENSE
10.29 13.46
(0.405) (0.530)
1.60
(0.063)
ON/OFF
+VIN
SURFACE MOUNT CONTACT
2.84
(0.112)
1.91 (0.075)
1.22
(0.048)
Dimensions are in millimeters(Inches)
L1 INDUCTOR
W
Ao
To lerances :X.X ±0.5mm(0.02in),X.XX ±0.25mm(0.010in),unless otherwise noted.
Bo
Figure 17 VPOL15A-5-SMT Mechanical Outline Diagram
Ko
P
F
E
D
D1
Po
P2
t
Figure 18 – VPOL15A-5-SMT Tape a nd Reel Dimensions
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382