EXAR XRT86VL38_07

XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
APRIL 2007
REV. V1.2.1
GENERAL DESCRIPTION
The XRT86VL38 is an eight-channel 1.544 Mbit/s or
2.048 Mbit/s DS1/E1/J1 framer and LIU integrated
solution featuring R3 technology (Relayless,
Reconfigurable, Redundancy). The physical interface
is optimized with internal impedance, and with the
patented pad structure, the XRT86VL38 provides
protection from power failures and hot swapping.
The XRT86VL38 contains an integrated DS1/E1/J1
framer and LIU which provide DS1/E1/J1 framing and
error accumulation in accordance with ANSI/ITU_T
specifications. Each framer has its own framing
synchronizer and transmit-receive slip buffers. The
slip buffers can be independently enabled or disabled
as required and can be configured to frame to the
common DS1/E1/J1 signal formats.
Each Framer block contains its own Transmit and
Receive E1/J1 Framing function. There are 3
Transmit HDLC controllers per channel which
encapsulate contents of the Transmit HDLC buffers
into LAPD Message frames. There are 3 Receive
HDLC controllers per channel which extract the
payload content of Receive LAPD Message frames
from the incoming E1/J1 data stream and write the
contents into the Receive HDLC buffers. Each framer
also contains a Transmit and Overhead Data Input
port, which permits Data Link Terminal Equipment
direct access to the outbound E1/J1 frames.
Likewise, a Receive Overhead output data port
permits Data Link Terminal Equipment direct access
to the Data Link bits of the inbound E1/J1 frames.
The XRT86VL38 fully meets all of the latest E1/J1
specifications:
ANSI E1.107-1988, ANSI E1.4031995, ANSI E1.231-1993, ANSI E1.408-1990, AT&T
TR 62411 (12-90) TR54016, and ITU G-703, G.704,
G706 and G.733, AT&T Pub. 43801, and ETS 300
011, 300 233, JT G.703, JT G.704, JT G706, I.431.
Extensive test and diagnostic functions include Loopbacks, Boundary scan, Pseudo Random bit
sequence
(PRBS)
test
pattern
generation,
Performance Monitor, Bit Error Rate (BER) meter,
forced error insertion, and LAPD unchannelized data
payload processing according to ITU-T standard
Q.921.
Applications and Features (next page)
FIGURE 1. XRT86VL38 8-CHANNEL DS1 (E1/J1) FRAMER/LIU COMBO
Local PCM
Highway
External Data
Link Controller
XRT86VL38
Tx Overhead In
Rx Overhead Out
1 of 8-channels
Tx Serial
Data In
2-Frame
Slip Buffer
Elastic Store
Tx Framer
ST-BUS
Tx Serial
Clock
Rx Serial
Clock
TTIP
Tx LIU
Interface
LLB
TRING
LB
RTIP
Rx Serial
Data Out
2-Frame
Slip Buffer
Elastic Store
Rx Framer
Rx LIU
Interface
PRBS
Generator &
Analyser
Performance
Monitor
HDLC/LAPD
Controllers
LIU &
Loopback
Control
1:1 Turns Ratio
RRING
RxLOS
Line Side
8kHz sync
OSC
Back Plane
1.544-16.384 Mbit/s
1:2 Turns Ratio
Signaling &
Alarms
DMA
Interface
JTAG
Microprocessor
Interface
3
System (Terminal) Side
INT
TxON
Memory
D[7:0]
µP
A[14:0]
Select
4 WR
ALE_AS
RD
RDY_DTACK
Intel/Motorola µP
Configuration, Control &
Status Monitor
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • (510) 668-7000 • FAX (510) 668-7017 • www.exar.com
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
APPLICATIONS
• High-Density E1/J1 interfaces for Multiplexers, Switches, LAN Routers and Digital Modems
• SONET/SDH terminal or Add/Drop multiplexers (ADMs)
• E1/J1 add/drop multiplexers (MUX)
• Channel Service Units (CSUs): E1/J1 and Fractional E1/J1
• Digital Access Cross-connect System (DACs)
• Digital Cross-connect Systems (DCS)
• Frame Relay Switches and Access Devices (FRADS)
• ISDN Primary Rate Interfaces (PRA)
• PBXs and PCM channel bank
• T3 channelized access concentrators and M13 MUX
• Wireless base stations
• ATM equipment with integrated DS1 interfaces
• Multichannel DS1 Test Equipment
• E1/J1 Performance Monitoring
• Voice over packet gateways
• Routers
FEATURES
• Eight independent, full duplex DS1 Tx and Rx Framer/LIUs
• Two 512-bit (two-frame) elastic store, PCM frame slip buffers (FIFO) on TX and Rx provide up to 8.192 MHz
asynchronous back plane connections with jitter and wander attenuation
• Supports input PCM and signaling data at 1.544, 2.048, 4.096 and 8.192 Mbits. Also supports 4-channel
multiplexed 12.352/16.384 (HMVIP/H.100) Mbit/s on the back plane bus
• Programmable output clocks for Fractional E1/J1
• Supports Channel Associated Signaling (CAS)
• Supports Common Channel Signalling (CCS)
• Supports ISDN Primary Rate Interface (ISDN PRI) signaling
• Extracts and inserts robbed bit signaling (RBS)
• 3 Integrated HDLC controllers per channel for transmit and receive, each controller having two 96-byte
buffers (buffer 0 / buffer 1)
• HDLC Controllers Support SS7
• Timeslot assignable HDLC
• V5.1 or V5.2 Interface
• Automatic Performance Report Generation (PMON Status) can be inserted into the transmit LAPD interface
every 1 second or for a single transmission
• Alarm Indication Signal with Customer Installation signature (AIS-CI)
• Remote Alarm Indication with Customer Installation (RAI-CI)
• Gapped Clock interface mode for Transmit and Receive.
2
XRT86VL38
REV. V1.2.1
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
• Intel/Motorola and Power PC interfaces for configuration, control and status monitoring
• Parallel search algorithm for fast frame synchronization
• Wide choice of T1 framing structures: SF/D4, ESF, SLC®96, T1DM and N-Frame (non-signaling)
• Direct access to D and E channels for fast transmission of data link information
• PRBS, QRSS, and Network Loop Code generation and detection
• Programmable Interrupt output pin
• Supports programmed I/O and DMA modes of Read-Write access
• Each framer block encodes and decodes the E1/J1 Frame serial data
• Detects and forces Red (SAI), Yellow (RAI) and Blue (AIS) Alarms
• Detects OOF, LOF, LOS errors and COFA conditions
• Loopbacks: Local (LLB) and Line remote (LB)
• Facilitates Inverse Multiplexing for ATM
• Performance monitor with one second polling
• Boundary scan (IEEE 1149.1) JTAG test port
• Accepts external 8kHz Sync reference
• 1.8V Inner Core Voltage
• 3.3V I/O operation with 5V tolerant inputs
• 420-pin PBGA package or 484-pin STBGA package with -40°C to +85°C operation
ORDERING INFORMATION
PART NUMBER
PACKAGE
OPERATING TEMPERATURE RANGE
XRT86VL38IB
420 Plastic Ball Grid Array
-40°C to +85°C
XRT86VL38IB484
484 Shrink Thin Ball Grid Array
-40°C to +85°C
3
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
420 BALL - PLASTIC BALL GRID ARRAY (BOTTOM VIEW, SEE PIN LIST FOR DESCRIPTION)
26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
O O O O O O O O O O O O O O O O O O O O O O O O O O
A
O O O O O O O O O O O O O O O O O O O O O O O O O O
B
O O O O O O O O O O O O O O O O O O O O O O O O O O
C
O O O O O O O O O O O O O O O O O O O O O O O O O O
D
O O O O O O O O O O O O O O O O O O O O O O O O O O
E
O O O O O
O O O O O
F
O O O O O
O O O O O
G
O O O O O
O O O O O
H
O O O O O
O O O O O
J
O O O O O
O O O O O
K
O O O O O
O O O O O
L
O O O O O
O O O O O
M
O O O O O
O O O O O
N
O O O O O
O O O O O
P
O O O O O
O O O O O
R
O O O O O
O O O O O
T
O O O O O
O O O O O
U
O O O O O
O O O O O
V
O O O O O
O O O O O
W
O O O O O
O O O O O
Y
O O O O O
O O O O O
AA
O O O O O O O O O O O O O O O O O O O O O O O O O O
AB
O O O O O O O O O O O O O O O O O O O O O O O O O O
AC
O O O O O O O O O O O O O O O O O O O O O O O O O O
AD
O O O O O O O O O O O O O O O O O O O O O O O O O O
AE
O O O O O O O O O O O O O O O O O O O O O O O O O O
AF
4
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
484 BALL - SHRINK THIN BALL GRID ARRAY (BOTTOM VIEW - SEE PIN LIST FOR DESCRIPTION)
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
O O O O O O O O O O O O O O O O O O O O O O
A
O O O O O O O O O O O O O O O O O O O O O O
B
O O O O O O O O O O O O O O O O O O O O O O
C
O O O O O O O O O O O O O O O O O O O O O O
D
O O O O O O O O O O O O O O O O O O O O O O
E
O O O O O O O O O O O O O O O O O O O O O O
F
O O O O O O O O O O O O O O O O O O O O O O
G
O O O O O O O O O O O O O O O O O O O O O O
H
O O O O O O O O O O O O O O O O O O O O O O
J
O O O O O O O O O O O O O O O O O O O O O O
K
O O O O O O O O O O O O O O O O O O O O O O
L
O O O O O O O O O O O O O O O O O O O O O O
M
O O O O O O O O O O O O O O O O O O O O O O
N
O O O O O O O O O O O O O O O O O O O O O O
P
O O O O O O O O O O O O O O O O O O O O O O
R
O O O O O O O O O O O O O O O O O O O O O O
T
O O O O O O O O O O O O O O O O O O O O O O
U
O O O O O O O O O O O O O O O O O O O O O O
V
O O O O O O O O O O O O O O O O O O O O O O
W
O O O O O O O O O O O O O O O O O O O O O O
Y
O O O O O O O O O O O O O O O O O O O O O O
AA
O O O O O O O O O O O O O O O O O O O O O O
AB
5
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
LIST OF PARAGRAPHS
1.0 REGISTER DESCRIPTIONS - E1 MODE ..............................................................................................12
2.0 LINE INTERFACE UNIT (LIU SECTION) REGISTERS .......................................................................150
I
XRT86VL38
REV. V1.2.1
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
LIST OF FIGURES
Figure 1.: XRT86VL38 8-channel DS1 (E1/J1) Framer/LIU Combo .................................................................................. 1
II
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
LIST OF TABLES
Table 1:: Register Summary .............................................................................................................................................. 6
Table 2:: Clock Select Register (CSR)
Hex Address: 0xn100 .................. 12
Table 3:: Line Interface Control Register (LICR)
Hex Address: 0xn101 .................... 14
Table 4:: General Purpose Input/Output 0 Control Register (GPIOCR0)
Hex Address: 0x0102 ...................... 16
Table 5:: General Purpose Input/Output 1 Control Register (GPIOCR1)
Hex Address: 0x4102 ....................... 17
Table 6:: Framing Select Register (FSR)
Hex Address: 0xn107 ................ 18
Table 7:: Alarm Generation Register (AGR)
Hex Address: 0xn108 ................... 22
Table 8:: Synchronization MUX Register (SMR)
Hex Address: 0xn109 ................. 24
Table 9:: Transmit Signaling and Data Link Select Register (TSDLSR)
Hex Address:0xn10A .................... 27
Table 10:: Framing Control Register (FCR)
Hex Address: 0xn10B ............... 30
Table 11:: Receive Signaling & Data Link Select Register (RSDLSR)
Hex Address: 0xn10C ................ 32
Table 12:: Receive Signaling Change Register 0 (RSCR 0)
Hex Address: 0xn10D ............ 34
Table 13:: Receive Signaling Change Register 1 (RSCR 1)
Hex Address: 0xn10E ........... 34
Table 14:: Receive Signaling Change Register 2 (RSCR 2)
Hex Address: 0xn10F ........... 34
Table 15:: Receive Signaling Change Register 3 (RSCR 3)
Hex Address: 0xn110 .......... 35
Table 16:: Receive National Bits Register (RNBR)
Hex Address: 0xn111 ............... 36
Table 17:: Receive Extra Bits Register (REBR)
Hex Address: 0xn112 .............. 37
Table 18:: Data Link Control Register (DLCR1)
Hex Address: 0xn113 .................. 39
Table 19:: Transmit Data Link Byte Count Register (TDLBCR1)
Hex Address: 0xn114 ............... 41
Table 20:: Receive Data Link Byte Count Register (RDLBCR1)
Hex Address: 0xn115 ................ 42
Table 21:: Slip Buffer Control Register (SBCR)
Hex Address: 0xn116 ................... 43
Table 22:: FIFO Latency Register (FFOLR)
Hex Address: 0xn117 ............... 44
Table 23:: DMA 0 (Write) Configuration Register (D0WCR)
Hex Address: 0xn118 ................. 45
Table 24:: DMA 1 (Read) Configuration Register (D1RCR)
Hex Address: 0xn119 ................ 46
Table 25:: Interrupt Control Register (ICR)
Hex Address: 0xn11A .................. 47
Table 26:: LAPD Select Register (LAPDSR)
Hex Address: 0xn11B ................ 48
Table 27:: Performance Report Control Register (PRCR)
Hex Address: 0xn11D ................... 48
Table 28:: Gapped Clock Control Register (GCCR)
Hex Address: 0xn11E ................. 49
Table 29:: Transmit Interface Control Register (TICR)
Hex Address:0xn120 ................... 50
Table 30:: Transmit Interface Speed When Multiplexed Mode is Disabled (TxMUXEN = 0) ........................................... 52
Table 31:: Transmit Interface Speed when Multiplexed Mode is Enabled (TxMUXEN = 1) ............................................ 53
Table 32:: PRBS Control And Status Register 0 (PRBSCSR0)
Hex Address: 0xn121 ................ 54
Table 33:: Receive Interface Control Register (RICR)
Hex Address: 0xn122 .................. 56
Table 34:: Receive Interface Speed When Multiplexed Mode is Disabled (TxMUXEN = 0) ............................................ 58
Table 35:: Receive Interface Speed when Multiplexed Mode is Enabled (TxMUXEN = 1) ............................................. 59
Table 36:: PRBS Control and Status Register 1 (PRBSCSR1)
Hex Address: 0xn123 ................. 60
Table 37:: Loopback Code Control Register (LCCR)
Hex Address: 0xn124 .................. 62
Table 38:: Transmit Loopback Coder Register (TLCR)
Hex Address: 0xn125 ................. 62
Table 39:: Receive Loopback Activation Code Register (RLACR)
Hex Address: 0xn126 ............... 62
Table 40:: Receive Loopback Deactivation Code Register (RLDCR)
Hex Address: 0xn127 ................... 62
Table 41:: Defect Detection Enable Register (DDER)
Hex Address: 0xn129 ................... 62
Table 42:: Transmit Sa Select Register (TSASR)
Hex Address: 0xn130 ................ 63
Table 43:: Transmit Sa Auto Control Register 1 (TSACR1)
Hex Address: 0xn131 ................... 65
Table 44:: Conditions on Receive side When TSACR1 bits Are enabled ........................................................................ 66
Table 45:: Transmit Sa Auto Control Register 2 (TSACR2)
Hex Address: 0xn132 ...................... 67
Table 46:: Conditions on Receive side When TSACR2 bits enabled .............................................................................. 68
Table 47:: Transmit Sa4 Register (TSA4R)
Hex Address: 0xn133 ............. 69
Table 48:: Transmit Sa5 Register (TSA5R)
Hex Address: 0xn134 ............. 69
Table 49:: Transmit Sa6 Register (TSA6R)
Hex Address: 0xn135 ............. 69
Table 50:: Transmit Sa7 Register (TSA7R)
Hex Address: 0xn136 ............. 69
Table 51:: Transmit Sa8 Register (TSA8R)
Hex Address: 0xn137 ............. 70
Table 52:: Receive Sa4 Register (RSA4R)
Hex Address: 0xn13B ............. 71
Table 53:: Receive Sa5 Register (RSA5R)
Hex Address: 0xn13C ............. 71
Table 54:: Receive Sa6 Register (RSA6R)
Hex Address: 0xn13D ............. 71
Table 55:: Receive Sa7 Register (RSA7R)
Hex Address: 0xn13E ............. 72
Table 56:: Receive Sa8 Register (RSA8R)
Hex Address: 0xn13F ............. 72
Table 57:: Data Link Control Register (DLCR2)
Hex Address: 0xn143 .............. 73
Table 58:: Transmit Data Link Byte Count Register (TDLBCR2)
Hex Address: 0xn144 ............... 75
III
XRT86VL38
REV. V1.2.1
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
Table 59:: Receive Data Link Byte Count Register (RDLBCR2)
Hex Address: 0xn145 ................ 76
Table 60:: Data Link Control Register (DLCR3)
Hex Address: 0xn153 ................ 77
Table 61:: Transmit Data Link Byte Count Register (TDLBCR3)
Hex Address: 0xn154 ................. 79
Table 62:: Receive Data Link Byte Count Register (RDLBCR3)
Hex Address: 0xn155 ............... 80
Table 63:: Device ID Register (DEVID)
Hex Address: 0xn1FE ............. 81
Table 64:: Revision ID Register (REVID)
Hex Address: 0xn1FF .......... 81
Table 65:: Transmit Channel Control Register 0-31 (TCCR 0-31)
Hex Address: 0Xn300 to 0xn31F ................... 82
Table 66:: Transmit User Code Register 0 - 31 (TUCR 0-31)
Hex Address: 0xn320 to 0xn33F .............. 84
Table 67:: Transmit Signaling Control Register 0-31 (TSCR 0-31)
Hex Address: 0xn340 to 0xn35F ................... 85
Table 68:: Receive Channel Control Register x (RCCR 0-31)
Hex Address: 0xn360 to 0xn37F ................. 88
Table 69:: Receive User Code Register 0-31 (RUCR 0-31)
Hex Address: 0xn380 to 0xn39F ............... 90
Table 70:: Receive Signaling Control Register 0-31 (RSCR 0-31)
Hex Address: 0xn3A0 to 0xn3BF ................... 91
Table 71:: Receive Substitution Signaling Register 0-31 (RSSR 0-31) Hex Address 0xn3C0 to 0xn3DF .................. 93
Table 72:: Receive Signaling Array Register 0 - 31 (RSAR 0-31)
Hex Address: 0Xn500 to 0xn51F ................. 94
Table 73:: LAPD Buffer 0 Control Register (LAPDBCR0)
Hex Address: 0xn600 .................................... 95
Table 74:: LAPD Buffer 1 Control Register (LAPDBCR1)
Hex Address: 0xn700 .................................... 95
Table 75:: PMON Receive Line Code Violation Counter MSB (RLCVCU)
Hex Address: 0xn900 ................. 96
Table 76:: PMON Receive Line Code Violation Counter LSB (RLCVCL)
Hex Address: 0xn901 ................ 96
Table 77:: PMON Receive Framing Alignment Bit Error Counter MSB (RFAECU) Hex Address: 0xn902 ................... 97
Table 78:: PMON Receive Framing Alignment Bit Error Counter LSB (RFAECL) Hex Address: 0xn903 .................... 97
Table 79:: PMON Receive Severely Errored Frame Counter (RSEFC)
Hex Address: 0xn904 .................... 98
Table 80:: PMON Receive CRC-4 Bit Error Counter - MSB (RSBBECU)
Hex Address: 0xn905 ................... 98
Table 81:: PMON Receive CRC-4 Block Error Counter - LSB (RSBBECL)
Hex Address: 0xn906 .................... 98
Table 82:: PMON Receive Far-End BLock Error Counter - MSB (RFEBECU)
Hex Address: 0xn907 .................. 99
Table 83:: PMON Receive Far End Block Error Counter -LSB (RFEBECL)
Hex Address: 0xn908 .................... 99
Table 84:: PMON Receive Slip Counter (RSC)
Hex Address: 0xn909 ........... 100
Table 85:: PMON Receive Loss of Frame Counter (RLFC)
Hex Address: 0xn90A ............. 100
Table 86:: PMON Receive Change of Frame Alignment Counter (RCFAC)
Hex Address: 0xn90B ............... 100
Table 87:: PMON LAPD Frame Check Sequence Error Counter 1 (LFCSEC1)
Hex Address: 0xn90C ............... 101
Table 88:: PMON PRBS Bit Error Counter MSB (PBECU)
Hex Address: 0xn90D ............ 101
Table 89:: PMON PRBS Bit Error Counter LSB (PBECL)
Hex Address: 0xn90E ........... 101
Table 90:: PMON Transmit Slip Counter (TSC)
Hex Address: 0xn90F ........... 102
Table 91:: PMON Excessive Zero Violation Counter MSB (EZVCU)
Hex Address: 0xn910 ................ 102
Table 92:: PMON Excessive Zero Violation Counter LSB (EZVCL)
Hex Address: 0xn911 ................ 102
Table 93:: PMON Frame Check Sequence Error Counter 2 (LFCSEC2)
Hex Address: 0xn91C ................ 103
Table 94:: PMON Frame Check Sequence Error Counter 3 (LFCSEC3)
Hex Address: 0xn92C ................ 103
Table 95:: Block Interrupt Status Register (BISR)
Hex Address: 0xnB00 ................... 104
Table 96:: Block Interrupt Enable Register (BIER)
Hex Address: 0xnB01 .................. 106
Table 97:: Alarm & Error Interrupt Status Register (AEISR)
Hex Address: 0xnB02 ...................... 108
Table 98:: Alarm & Error Interrupt Enable Register (AEIER)
Hex Address: 0xnB03 ..................... 110
Table 99:: Framer Interrupt Status Register (FISR)
Hex Address: 0xnB04 ................ 112
Table 100:: Framer Interrupt Enable Register (FIER)
Hex Address: 0xnB05 .............. 115
Table 101:: Data Link Status Register 1 (DLSR1)
Hex Address: 0xnB06 ............ 117
Table 102:: Data Link Interrupt Enable Register 1 (DLIER1)
Hex Address: 0xnB07 ................. 119
Table 103:: Slip Buffer Interrupt Status Register (SBISR)
Hex Address: 0xnB08 ................ 121
Table 104:: Slip Buffer Interrupt Enable Register (SBIER)
Hex Address: 0xnB09 ................... 124
Table 105:: Receive Loopback Code Interrupt and Status Register (RLCISR)
Hex Address: 0xnB0A ................... 126
Table 106:: Receive Loopback Code Interrupt Enable Register (RLCIER)
Hex Address: 0xnB0B ................ 128
Table 107:: Receive SA Interrupt Status Register (RSAISR)
Hex Address: 0xnB0C .............. 129
Table 108:: Receive SA Interrupt Enable Register (RSAIER)
Hex Address: 0xnB0D .............. 132
Table 109:: Excessive Zero Status Register (EXZSR)
Hex Address: 0xnB0E ........... 135
Table 110:: Excessive Zero Enable Register (EXZER)
Hex Address: 0xnB0F ............ 136
Table 111:: SS7 Status Register for LAPD1 (SS7SR1)
Hex Address: 0xnB10 .............. 136
Table 112:: SS7 Enable Register for LAPD1 (SS7ER1)
Hex Address: 0xnB11 ............ 137
Table 113:: RxLOS/CRC Interrupt Status Register (RLCISR)
Hex Address: 0xnB12 ............. 137
Table 114:: RxLOS/CRC Interrupt Enable Register (RLCIER)
Hex Address: 0xnB13 ............. 139
Table 115:: Data Link Status Register 2 (DLSR2)
Hex Address: 0xnB16 .............. 140
Table 116:: Data Link Interrupt Enable Register 2 (DLIER2)
Hex Address: 0xnB17 ................ 142
Table 117:: SS7 Status Register for LAPD2 (SS7SR2)
Hex Address: 0xnB18 .............. 144
Table 118:: SS7 Enable Register for LAPD2 (SS7ER2)
Hex Address: 0xnB19 .............. 144
IV
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
Table 119:: Data Link Status Register 3 (DLSR3)
Hex Address: 0xnB26 .............. 145
Table 120:: Data Link Interrupt Enable Register 3 (DLIER3)
Hex Address: 0xnB27 ............... 147
Table 121:: SS7 Status Register for LAPD3 (SS7SR3)
Hex Address: 0xnB28 ............. 149
Table 122:: SS7 Enable Register for LAPD3 (SS7ER3)
Hex Address: 0xnB29 ............ 149
Table 123:: LIU Channel Control Register 0 (LIUCCR0)
Hex Address: 0x0Fn0 ............. 150
Table 124:: Equalizer Control and Transmit Line Build Out ........................................................................................... 152
Table 125:: LIU Channel Control Register 1 (LIUCCR1)
Hex Address: 0x0Fn1 ............. 153
Table 126:: LIU Channel Control Register 2 (LIUCCR2)
Hex Address: 0x0Fn2 ............. 155
Table 127:: LIU Channel Control Register 3 (LIUCCR3)
Hex Address: 0x0Fn3 ............. 157
Table 128:: LIU Channel Control Interrupt Enable Register (LIUCCIER)
Hex Address: 0x0Fn4 .................. 159
Table 129:: LIU Channel Control Status Register (LIUCCSR)
Hex Address: 0x0Fn5 ................. 161
Table 130:: LIU Channel Control Interrupt Status Register (LIUCCISR)
Hex Address: 0x0Fn6 .................... 164
Table 131:: LIU Channel Control Cable Loss Register (LIUCCCCR)
Hex Address: 0x0Fn7 ................ 166
Table 132:: LIU Channel Control Arbitrary Register 1 (LIUCCAR1)
Hex Address: 0x0Fn8 ................... 166
Table 133:: LIU Channel Control Arbitrary Register 2 (LIUCCAR2)
Hex Address: 0x0Fn9 ................... 166
Table 134:: LIU Channel Control Arbitrary Register 3 (LIUCCAR3)
Hex Address: 0x0FnA .................. 167
Table 135:: LIU Channel Control Arbitrary Register 4 (LIUCCAR4)
Hex Address: 0x0FnB .................. 167
Table 136:: LIU Channel Control Arbitrary Register 5 (LIUCCAR5)
Hex Address: 0x0FnC .................. 167
Table 137:: LIU Channel Control Arbitrary Register 6 (LIUCCAR6)
Hex Address: 0x0FnD .................. 168
Table 138:: LIU Channel Control Arbitrary Register 7 (LIUCCAR7)
Hex Address: 0x0FnE .................. 168
Table 139:: LIU Channel Control Arbitrary Register 8 (LIUCCAR8)
Hex Address: 0x0FnF .................. 168
Table 140:: LIU Global Control Register 0 (LIUGCR0)
Hex Address: 0x0FE0 .............. 169
Table 141:: LIU Global Control Register 1 (LIUGCR1)
Hex Address: 0x0FE1 .............. 170
Table 142:: LIU Global Control Register 2 (LIUGCR2)
Hex Address: 0x0FE2 .............. 172
Table 143:: LIU Global Control Register 3 (LIUGCR3)
Hex Address: 0x0FE4 .............. 172
Table 144:: LIU Global Control Register 4 (LIUGCR4)
Hex Address: 0x0FE9 .............. 173
Table 145:: LIU Global Control Register 5 (LIUGCR5)
Hex Address: 0x0FEA .............. 174
V
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
DESCRIPTION OF THE CONTROL REGISTERS - E1 MODE
TABLE 1: REGISTER SUMMARY
FUNCTION
SYMBOL
HEX
Clock and Select Register
CSR
0xn100
Line Interface Control Register
LICR
0xn101
General Purpose Input/Output Control 0
GPIOCR0
0x0102
General Purpose Input/Output Control 1
GPIOCR1
0x4102
-
0xn103 - 0xn106
Framing Select Register
FSR
0xn107
Alarm Generation Register
AGR
0xn108
Synchronization MUX Register
SMR
0xn109
TSDLSR
0xn10A
FCR
0xn10B
RSDLSR
0xn10C
Receive Signaling Change Register 0
RSCR0
0xn10D
Receive Signaling Change Register 1
RSCR1
0xn10E
Receive Signaling Change Register 2
RSCR2
0xn10F
Receive Signaling Change Register 3
RSCR3
0xn110
Receive National Bits Register
RNBR
0xn111
Receive Extra Bits Register
REBR
0xn112
Data Link Control Register 1
DLCR1
0xn113
Transmit Data Link Byte Count Register 1
TDLBCR1
0xn114
Receive Data Link Byte Count Register 1
RDLBCR1
0xn115
SBCR
0xn116
FIFO Latency Register
FIFOLR
0xn117
DMA 0 (Write) Configuration Register
D0WCR
0xn118
DMA 1 (Read) Configuration Register
D1RCR
0xn119
ICR
0xn11A
LAPDSR
0xn11B
-
0xn11C
Performance Report Control Register
PRCR
0xn11D
Gapped Clock Control Register
GCCR
0xn11E
Transmit Interface Control Register
TICR
0xn120
Control Registers (0xn100 - 0xn1FF)
Reserved
Transmit Signaling and Data Link Select Register
Framing Control Register
Receive Signaling & Data Link Select Register
Slip Buffer Control Register
Interrupt Control Register
LAPD Select Register
Reserved - T1 mode only
6
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 1: REGISTER SUMMARY
FUNCTION
SYMBOL
HEX
PRBS Control & Status Register 0
PRBSCSR0
0xn121
Receive Interface Control Register
RICR
0xn122
PRBS Control & Status Register 1
PRBSCSR1
0xn123
-
0xn124 - 0xn127
Defect Detection Enable Register
DDER
0xn129
Transmit Sa Select Register
TSASR
0xn130
Transmit Sa Auto Control Register 1
TSACR1
0xn131
Transmit Sa Auto Control Register 2
TSACR2
0xn132
Transmit Sa4 Register
TSA4R
0xn133
Transmit Sa5 Register
TSA5R
0xn134
Transmit Sa6 Register
TSA6R
0xn135
Transmit Sa7 Register
TSA7R
0xn136
Transmit Sa8 Register
TSA8R
0xn137
Receive Sa4 Register
RSA4R
0xn13B
Receive Sa5 Register
RSA5R
0xn13C
Receive Sa6 Register
RSA6R
0xn13D
Receive Sa7 Register
RSA7R
0xn13E
Receive Sa8 Register
RSA8R
0xn13F
-
0xn142
DLCR2
0xn143
Transmit Data Link Byte Count Register 2
TDLBCR2
0xn144
Receive Data Link Byte Count Register 2
RDLBCR2
0xn145
DLCR3
0xn153
Transmit Data Link Byte Count Register 3
TDLBCR3
0xn154
Receive Data Link Byte Count Register 3
RDLBCR3
0xn155
Device ID Register
DEVID
0xn1FE
Revision Number Register
REVID
0xn1FF
Transmit Channel Control Register 0-31
TCCR 0-31
0xn300 0xn31F
User Code Register 0-31
TUCR 0-31
0xn320 0xn33F
Transmit Signaling Control Register 0 -31
TSCR 0-31
0xn340 0xn35F
For T1 mode only
Reserved - T1 mode only
Data Link Control Register 2
Data Link Control Register 3
Time Slot (payload) Control (0xn300 - 0xn3FF)
7
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 1: REGISTER SUMMARY
FUNCTION
SYMBOL
HEX
Receive Channel Control Register 0-31
RCCR 0-31
0xn360 0xn37F
Receive User Code Register 0-31
RUCR 0-31
0xn380 0xn39F
Receive Signaling Control Register 0-31
RSCR 0-31
0xn3A0 0xn3BF
Receive Substitution Signaling Register 0-31
RSSR 0-31
0xn3C0 0xn3DF
RSAR0-31
0xn500 0xn51F
LAPDBCR0
0xn600 0xn660
LAPDBCR1
0xn700 0xn760
Receive Line Code Violation Counter: MSB
RLCVCU
0xn900
Receive Line Code Violation Counter: LSB
RLCVCL
0xn901
Receive Frame Alignment Error Counter: MSB
RFAECU
0xn902
Receive Frame Alignment Error Counter: LSB
RFAECL
0xn903
Receive Severely Errored Frame Counter
RSEFC
0xn904
Receive Synchronization Bit (CRC-6 (T1) CRC-4 (E1) Block) Error
Counter: MSB
RSBBECU
0xn905
Receive Synchronization Bit (CRC-6 (T1) CRC-4 (E1) Block) Error
Counter: LSB
RSBBECL
0xn906
Receive Far-End Block Error Counter: MSB
RFEBECU
0xn907
Receive Far-End Block Error Counter: LSB
RFEBECL
0xn908
Receive Slip Counter
RSC
0xn909
Receive Loss of Frame Counter
RLFC
0xn90A
Receive Change of Frame Alignment Counter
RCFAC
0xn90B
LAPD Frame Check Sequence Error counter 1
LFCSEC1
0xn90C
PRBS bit Error Counter: MSB
PBECU
0xn90D
PRBS bit Error Counter: LSB
PBECL
0xn90E
TSC
0xn90F
Receive Signaling Array (0xn500 - 0xn51F)
Receive Signaling Array Register 0
LAPDn Buffer 0
LAPD Buffer 0 Control Register
LAPDn Buffer 1
LAPD Buffer 1 Control Register
Performance Monitor
Transmit Slip Counter
8
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 1: REGISTER SUMMARY
FUNCTION
SYMBOL
HEX
Excessive Zero Violation Counter: MSB
EZVCU
0xn910
Excessive Zero Violation Counter: LSB
EZVCL
0xn911
LAPD Frame Check Sequence Error counter 2
LFCSEC2
0xn91C
LAPD Frame Check Sequence Error counter 3
LFCSEC3
0xn92C
Block Interrupt Status Register
BISR
0xnB00
Block Interrupt Enable Register
BIER
0xnB01
Alarm & Error Interrupt Status Register
AEISR
0xnB02
Alarm & Error Interrupt Enable Register
AEIER
0xnB03
Framer Interrupt Status Register
FISR
0xnB04
Framer Interrupt Enable Register
FIER
0xnB05
Data Link Status Register 1
DLSR1
0xnB06
Data Link Interrupt Enable Register 1
DLIER1
0xnB07
Slip Buffer Interrupt Status Register
SBISR
0xnB08
Slip Buffer Interrupt Enable Register
SBIER
0xnB09
Receive Loopback code Interrupt and Status Register
RLCISR
0xnB0A
Receive Loopback code Interrupt Enable Register
RLCIER
0xnB0B
Receive SA (Sa6) Interrupt Status Register
RSAISR
0xnB0C
Receive SA (Sa6) Interrupt Enable Register
RSAIER
0xnB0D
Excessive Zero Status Register
EXZSR
0xnB0E
Excessive Zero Enable Register
EXZER
0xnB0F
SS7 Status Register for LAPD 1
SS7SR1
0xnB10
SS7 Enable Register for LAPD 1
SS7ER1
0xnB11
RxLOS/CRC Interrupt Status Register
RLCISR
0xnB12
RxLOS/CRC Interrupt Enable Register
RLCIER
0xnB13
Data Link Status Register 2
DLSR2
0xnB16
Data Link Interrupt Enable Register 2
DLIER2
0xnB17
SS7 Status Register for LAPD 2
SS7SR2
0xnB18
SS7 Enable Register for LAPD 2
SS7ER2
0xnB19
Data Link Status Register 3
DLSR3
0xnB26
Data Link Interrupt Enable Register 3
DLIER3
0xnB27
SS7 Status Register for LAPD 3
SS7SR3
0xnB28
SS7 Enable Register for LAPD 3
SS7ER3
0xnB29
Interrupt Generation/Enable Register Address Map (0xnB00 - 0xnB41)
9
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 1: REGISTER SUMMARY
FUNCTION
SYMBOL
HEX
CIAIER
0xnB40 - 0xnB41
LIU Channel Control Register 0
LIUCCR0
0x0Fn0
LIU Channel Control Register 1
LIUCCR1
0x0Fn1
LIU Channel Control Register 2
LIUCCR2
0x0Fn2
LIU Channel Control Register 3
LIUCCR3
0x0Fn3
LIU Channel Control Interrupt Enable Register
LIUCCIER
0x0Fn4
LIU Channel Control Status Register
LIUCCSR
0x0Fn5
LIU Channel Control Interrupt Status Register
LIUCCISR
0x0Fn6
LIU Channel Control Cable Loss Register
LIUCCCCR
0x0Fn7
LIU Channel Control Arbitrary Register 1
LIUCCAR1
0x0Fn8
LIU Channel Control Arbitrary Register 2
LIUCCAR2
0x0Fn9
LIU Channel Control Arbitrary Register 3
LIUCCAR3
0x0FnA
LIU Channel Control Arbitrary Register 4
LIUCCAR4
0x0FnB
LIU Channel Control Arbitrary Register 5
LIUCCAR5
0x0FnC
LIU Channel Control Arbitrary Register 6
LIUCCAR6
0x0FnD
LIU Channel Control Arbitrary Register 7
LIUCCAR7
0x0FnE
LIU Channel Control Arbitrary Register 8
LIUCCAR8
0x0FnF
-
0x0F80 0x0FDF
LIU Global Control Register 0
LIUGCR0
0x0FE0
LIU Global Control Register 1
LIUGCR1
0x0FE1
LIU Global Control Register 2
LIUGCR2
0x0FE2
LIU Global Control Register 3
LIUGCR3
0x0FE4
LIU Global Control Register 4
LIUGCR4
0x0FE9
LIU Global Control Register 5
LIUGCR5
0x0FEA
-
0x0FEB 0x0FFF
Reserved - T1 mode only
LIU Register Summary - Channel Control Registers
Reserved
LIU Register Summary - Global Control Registers
Reserved
10
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
11
REV. V1.2.1
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
1.0 REGISTER DESCRIPTIONS - E1 MODE
TABLE 2: CLOCK SELECT REGISTER (CSR)
BIT
FUNCTION
TYPE
DEFAULT
HEX ADDRESS: 0Xn100
DESCRIPTION-OPERATION
7
LCV Insert
R/W
0
Line Code Violation Insertion
This bit is used to force a Line Code Violation (LCV) on the transmit
output of TTIP/TRING.
A “0” to “1” transition on this bit will cause a single LCV to be inserted
on the transmit output of TTIP/TRING.
6
Set T1 Mode
R/W
0
T1/E1 Mode select
This bit is used to program the individual channel to operate in either
T1 or E1 mode.
0 = Configures the selected channel to operate in E1 mode.
1 = Configures the selected channel to operate in T1 mode.
5
Sync All Transmitters to 8kHz
R/W
0
Sync All Transmit Framers to 8kHz
This bit permits the user to configure each of the eight (8) Transmit E1
Framer blocks to synchronize their “transmit output” frame alignment
with the 8kHz signal that is derived from the MCLK PLL, as described
below.
0 - Disables the “Sync all Transmit Framers to 8kHz” feature for all 8
channels.
1 - Enables the “Sync all Transmit Framers to 8kHz” feature for all 8
channels.
NOTE: Writing to this bit in register 0x0100 will enable this feature for
all 8 channels.
NOTE: This bit is only active if the MCLK PLL is used as the “Timing
Source” for the Transmit E1 Framer” blocks. CSS[1:0] of this
register allows users to select the transmit source of the
framer.
4
Clock Loss Detect
R/W
1
Clock Loss Detect Enable/Disable Select
This bit enables a clock loss protection feature for the Framer whenever the recovered line clock is used as the timing source for the transmit section. If the LIU loses clock recovery, the Clock Distribution Block
will detect this occurrence and automatically begin to use the internal
clock derived from MCLK PLL as the Transmit source, until the LIU is
able to regain clock recovery.
0 = Disables the clock loss protection feature.
1 = Enables the clock loss protection feature.
NOTE: This bit needs to be enabled in order to detect the clock loss
detection interrupt status (address: 0xnB00, bit 5)
3:2
Reserved
R/W
00
Reserved
12
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 2: CLOCK SELECT REGISTER (CSR)
BIT
1:0
FUNCTION
CSS[1:0]
REV. V1.2.1
HEX ADDRESS: 0Xn100
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
01
Clock Source Select
These bits select the timing source for the Transmit E1 Framer block.
These bits can also determine the direction of TxSERCLK, TxSYNC,
and TxMSYNC in base rate operation mode (2.048MHz Clock mode).
In Base Rate (2.048MHz Clock Mode):
CSS[1:0]
00/11
TRANSMIT SOURCE FOR THE
TRANSMIT E1 FRAMER BLOCK
Loop Timing Mode
The recovered line clock is chosen as the timing source.
01
External Timing Mode
The Transmit Serial Input Clock
from the TxSERCLK_n input pin is
chosen as the timing source.
10
Internal Timing Mode
The MCLK PLL is chosen as the
timing source.
DIRECTION OF
TXSERCLK
Output
Input
Output
NOTE: TxSYNC/TxMSYNC can be programmed as input or output
depending on the setting of SYNC INV bit in Register Address
0xn109, bit 4. Please see Register Description for the
Synchronization Mux Register (SMR - 0xn109).
NOTES: In High-Speed or multiplexed modes, TxSERCLK, TxSYNC,
and TxMSYNC are all configured as INPUTS only.
13
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 3: LINE INTERFACE CONTROL REGISTER (LICR)
BIT
FUNCTION
HEX ADDRESS: 0Xn101
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
FORCE_LOS
R/W
0
Force Transmit LOS (To the Line Side)
This bit permits the user to configure the transmit direction circuitry
(within the channel) to transmit the LOS pattern to the remote terminal
equipment, as described below.
0 - Configures the transmit direction circuitry to transmit “normal” traffic.
1 - Configures the transmit direction circuitry to transmit the LOS
Pattern.
6
SR
R/W
0
Single Rail Mode
This bit can only be set if the LIU Block is also set to single rail mode.
See Register 0x0FE0, bit 7.
0 - Dual Rail
1 - Single Rail
LB[1:0]
R/W
00
Framer Loopback Selection
These bits are used to select any of the following loop-back modes for
the framer section. For LIU loopback modes, see the LIU configuration
registers.
5:4
3:2
Reserved
R/W
0
LB[1:0]
TYPES OF LOOPBACK SELECTED
00
Normal Mode (No LoopBack)
01
Framer Local LoopBack:
When framer local loopback is enabled, the transmit
PCM input data is looped back to the receive PCM output data. The receive input data at RTIP/RRING is
ignored while an All Ones Signal is transmitted out to
the line interface.
10
Framer Far-End (Remote) Line LoopBack:
When framer remote loopback is enabled, the digital
data enters the framer interface, however does not
enter the framing blocks. The receive digital data from
the LIU is allowed to pass through the LIU Decoder/
Encoder circuitry before returning to the line interface.
11
Framer Payload LoopBack:
When framer payload loopback is enabled, the raw
data within the receive time slots are looped back to the
transmit framer block where the data is re-framed
according to the transmit timing.
Reserved
14
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 3: LINE INTERFACE CONTROL REGISTER (LICR)
BIT
1
FUNCTION
Encode B8ZS
TYPE
DEFAULT
R/W
0
REV. V1.2.1
HEX ADDRESS: 0Xn101
DESCRIPTION-OPERATION
Encode AMI or B8ZS/HDB3 Line Code Select
This bit enables or disables the B8ZS/HDB3 encoder on the transmit
path.
0 = Enables the B8ZS encoder.
1 = Disables the B8ZS encoder.
NOTE: When B8ZS encoder is disabled, AMI line code is used.
0
Decode AMI/B8ZS
R/W
0
Decode AMI or B8ZS/HDB3 Line Code Select
This bit enables or disables the B8ZS/HDB3 decoder on the receive
path.
0 = Enables the B8ZS decoder.
1 = Disables the B8ZS decoder.
NOTE: When B8ZS decoder is disabled, AMI line code is received.
15
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 4: GENERAL PURPOSE INPUT/OUTPUT 0 CONTROL REGISTER (GPIOCR0)
BIT
FUNCTION
7-4 GPIO0_3DIR
GPIO0_2DIR
GPIO0_1DIR
GPIO0_0DIR
TYPE
DEFAULT
R/W
1111
HEX ADDRESS: 0X0102
DESCRIPTION-OPERATION
GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 Direction
These bits permit the user to define the General Purpose I/O Pins,
GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 as either Input pins or Output
pins, as described below.
0 – Configures GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 to function as
input pins.
1 – Configures GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 to function as
output pins.
1. If GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 are configured to
function as input pins, then the user can monitor the state of
these input pins by reading out the state of Bit 3-0 (GPIO0_3/
GPIO0_2/GPIO0_1/GPIO0_0) within this register.
2. If GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 are configured to
function as output pins, then the user can control the state of
these output pins by writing the appropriate value into Bit 3-0
(GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0) within this register.
3-0 GPIO0_3
GPIO0_2
GPIO0_1
GPIO0_0
R/W
0000
GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 Control
The exact function of this bit depends upon whether General Purpose I/
O Pins, GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 have been configured
to function as input or output pins, as described below.
If GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 are configured to function
as input pins:
If GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 are configured to function as
input pins, then the user can monitor the state of the corresponding
input pin by reading out the state of these bits.
NOTE:
If GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 are configured to
function as input pins, then writing to this particular register will
have no effect on the state of this pin.
If GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 are configured to function
as output pins:
If GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 are configured to function as
output pins, then the user can control the state of the corresponding
output pin by writing the appropriate value to these bits.
NOTE: GPIO0_3/GPIO0_2/GPIO0_1/GPIO0_0 can be configured to
function as input or output pins, by writing the appropriate
value to Bit 7-4 (GPIO0_3DIR/GPIO0_2DIR/GPIO0_1DIR/
GPIO0_0DIR) within this register.
16
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 5: GENERAL PURPOSE INPUT/OUTPUT 1 CONTROL REGISTER (GPIOCR1)
BIT
FUNCTION
7-4 GPIO1_3DIR
GPIO1_2DIR
GPIO1_1DIR
GPIO1_0DIR
TYPE
DEFAULT
R/W
0000
REV. V1.2.1
HEX ADDRESS: 0X4102
DESCRIPTION-OPERATION
GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 Direction
These bits permit the user to define the General Purpose I/O Pins,
GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 as either Input pins or Output
pins, as described below.
0 – Configures GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 to function as
input pins.
1 – Configures GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 to function as
output pins.
1. If GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 are configured to
function as input pins, then the user can monitor the state of
these input pins by reading out the state of Bit 3-0 (GPIO1_3/
GPIO1_2/GPIO1_1/GPIO1_0) within this register.
2. If GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 are configured to
function as output pins, then the user can control the state of
these output pins by writing the appropriate value into Bit 3-0
(GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0) within this register.
3-0 GPIO1_3
GPIO1_2
GPIO1_1
GPIO1_0
R/W
0000
GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 Control
The exact function of this bit depends upon whether General Purpose I/
O Pins, GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 have been configured
to function as input or output pins, as described below.
If GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 are configured to function
as input pins:
If GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 are configured to function as
input pins, then the user can monitor the state of the corresponding
input pin by reading out the state of these bits.
NOTE:
If GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 are configured to
function as input pins, then writing to this particular register will
have no effect on the state of this pin.
If GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 are configured to function
as output pins:
If GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 are configured to function as
output pins, then the user can control the state of the corresponding
output pin by writing the appropriate value to these bits.
NOTE: GPIO1_3/GPIO1_2/GPIO1_1/GPIO1_0 can be configured to
function as input or output pins, by writing the appropriate
value to Bit 7-4 (GPIO1_3DIR/GPIO1_2DIR/GPIO1_1DIR/
GPIO1_0DIR) within this register.
17
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 6: FRAMING SELECT REGISTER (FSR)
HEX ADDRESS: 0Xn107
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
G.706 Annex B
CRC-4 Calculation Enable
R/W
0
G.706 Annex B CRC-4 Calculation Enable
This bit configures the E1 Receive Framer Block to be compliant with ITU-T
G.706 Annex B for CRC-to-non-CRC interworking detection. If Annex B is
enabled, G.706 Annex B CRC-4 multiframe alignment algorithm is implemented. If CRC-4 alignment is enabled and not achieved in 400msec while
the basic frame alignment signal is present, it is assumed that the remote
end is a non CRC-4 equipment. A CRC-to-Non-CRC interworking interrupt
will be generated. The CRC-to-Non-CRC interworking interrupt Status can
be read from Register Address 0xnB0A.
0 - Configures the Receive E1 Framer block to NOT support the “G.706
Annex B” CRC-4 Multiframe Alignment algorithm.
1 - Configures the Receive E1 Framer block to support the “G.706 Annex B”
CRC-4 Multiframe Alignment algorithm.
6
Transmit CRC-4
Error
R/W
0
Transmit CRC-4 Error
This bit is used to force a continuous errored CRC pattern in the outbound
CRC multiframe to be sent on the transmission line. The Transmit E1
Framer Block will implement this error by inverting the value of CRC bit
(C1).
0 = Disables the Transmit E1 Framer Block to transmit errored CRC bit.
1 = Forces the Transmit E1 Framer Block to transmit continuous errored
CRC bit.
NOTE: This bit is ignored if CRC multi-Framing is disabled.
18
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 6: FRAMING SELECT REGISTER (FSR)
BIT
FUNCTION
5-4 CAS MF Align
Sel[1:0]
REV. V1.2.1
HEX ADDRESS: 0Xn107
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
00
CAS Multiframe Alignment Declaration Algorithm Select[1:0]
These bits allow the user to select which CAS Multiframe Alignment Declaration algorithm the Receive E1 Framer block will employ, according to the
table below.
CAS MF
ALIGN
SEL[1:0]
00/11
CAS MULTIFRAME ALIGNMENT DECLARATION ALGORITHM
SELECTED
CAS Multiframe Alignment is Disabled
01
The “16-Frame” Algorithm
If this alignment algorithm is selected, then the Receive
E1 Framer block will monitor the 16th timeslot of each
incoming E1 frame and will declare CAS Multiframe alignment (e.g., clear the Loss of CAS Multiframe” defect) condition; anytime that it detects 15 consecutive E1 frames in
which bits 1 - 4 (of timeslot 16) do not contain the “CAS
Multiframe Alignment” pattern; which is immediately followed by an E1 frame that DOES contain the “CAS Multiframe Alignment” pattern.
10
The “2-Frame” (ITU-T G.732) Algorithm
If this alignment algorithm is selected, then the Receive
E1 Framer block will monitor the 16th timeslot of each
incoming E1 frame and will declare CAS Multiframe alignment (e.g., clear the Loss of CAS Multiframe” defect) condition; anytime that it detects a single E1 frame in which
bits 1 - 4 (of timeslot 16) do not contain the “CAS Multiframe Alignment” pattern; which is immediately followed
by an E1 frame that DOES contain the “CAS Multiframe
Alignment” pattern.
NOTE: For information on the criteria that the Receive E1 Framer block
uses in order to declare the “Loss of CAS Multiframe” defect
condition, please see register description for the Framing Control
Register (FCR - address 0xn10B)
19
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 6: FRAMING SELECT REGISTER (FSR)
BIT
FUNCTION
3-2 CRC MF Align
Sel[1:0]
HEX ADDRESS: 0Xn107
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
00
CRC Multiframe Alignment Declaration Criteria Select [1:0]
These two bits allow the user to select which CRC-Multiframe Alignment
Declaration criteria the Receive E1 Framer block will employ. The Receive
E1 Framer block will check for CRC Multiframe Alignment by checking the
incoming E1 data-stream and determining whether the international bits (bit
1 of timeslot 0) of non-FAS frames match the CRC multiframe alignment
pattern (0,0,1,0,1,1,E1,E2). The table below provides more details on the
three different CRC Multiframe Alignment Declaration Criteria.
CRC MF
ALIGN SEL
[1:0]
CRC MULTIFRAME ALIGNMENT DECLARATION CRITERIA
SELECTED
00
CRC Multiframe Alignment is Disabled
01
CRC Multiframe Alignment is Enabled. Alignment is
declared if at least 1 valid CRC multiframe alignment
signal (0,0,1,0,1,1,E1,E2) is observed within 8ms.
10
CRC Multiframe Alignment is Enabled. Alignment is
declared if at least 2 valid CRC multiframe alignment
signals (0,0,1,0,1,1,E1,E2) are observed within 8ms.
11
CRC Multiframe Alignment is Enabled. Alignment is
declared if at least 3 valid CRC multiframe alignment
signals (0,0,1,0,1,1,E1,E2) are observed within 8ms.
NOTE: For information on the criteria that the Receive E1 Framer block
uses to declare the “Loss of CRC Multiframe Alignment” defect
condition, please see register description for the Framing Control
Register (FCR - 0xn10B)
1
Additional Frame
Check Enable FAS
R/W
0
Additional Frame Check Enable - FAS Frame Alignment Declaration
This bit permits the user to configure the Receive E1 Framer block to perform some “additional FAS frame synchronization checking” prior to declaring “FAS Frame Alignment”. If the user implements this feature, then the
Receive E1 Framer block will perform some more testing on two additional
E1 frames, prior to declaring the “FAS Frame Alignment” condition.
0 - Disables this additional FAS frame checking.
1 - Enables this additional FAS frame checking.
20
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 6: FRAMING SELECT REGISTER (FSR)
REV. V1.2.1
HEX ADDRESS: 0Xn107
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
0
FAS Frame Align
Sel
R/W
0
FAS Alignment Declaration Algorithm Select
This bit specifies which algorithm the Receive E1 Framer block uses in its
search for the FAS Alignment.
0 = Selects the FAS Alignment Algorithm 1
1 = Selects the FAS Alignment Algorithm 2
FAS Alignment Algorithm 1
If the Receive E1 Framer block has been configured to use “FAS Alignment
Algorithm # 1", then it will acquire FAS alignment by performing the following three steps:
Step 1 - The Receive E1 Framer block begins by searching for the correct
7-bit FAS pattern. Go to Step 2 if found.
Step 2 - Check if the FAS is absent in the following frame by verifying that
bit 2 of the assumed timeslot 0 of the Non-FAS frame is a one. Go back to
Step 1 if failed, otherwise, go to step 3.
Step 3 - Check if the FAS is present in the assumed timeslot 0 of the third
frame. Go back to Step 1 if failed.
After the first three steps (if they all passed), the Receive E1 Framer Block
will declare FAS in SYNC if Frame Check Sequence (Bit 1 of this register) is
disabled. If Frame Check Sequence (Bit 1 of this register) is enabled, then
the Receive E1 Framer Block will need to verify the correct frame alignment
for an additional two frames.
FAS Alignment Algorithm 2
If the Receive E1 Framer block has been configured to support “FAS Alignment Algorithm # 2, then it will perform the following 3 steps in order to
acquire and declare FAS Frame Alignment with the incoming E1 datastream. Algorithm 2 is similar to Algorithm 1 but adds a one-frame hold off
time after the second step fails. After the second step fails, it waits for the
next assumed FAS in the next frame before it begins the new search for the
correct FAS pattern.
Step 1 - Algorithm 1 begins by searching for the correct 7-bit FAS pattern.
Go to Step 2 if found.
Step 2 - Check if the FAS is absent in the following frame by verifying that
bit 2 of the assumed timeslot 0 of the Non-FAS frame is a one. Go back to
Step 4 if failed, otherwise, go to step 3.
Step 3 - Check if the FAS is present in the assumed timeslot 0 of the third
frame. Go back to Step 1 if failed, otherwise, proceed to check for Frame
Check Sequence.
Step 4 - Wait for assumed FAS in the next frame, then go back to Step 1
After the first three steps (if they all passed), the Receive E1 Framer Block
will declare FAS in SYNC if Frame Check Sequence (Bit 1 of this register) is
disabled. If Frame Check Sequence (Bit 1 of this register) is enabled, then
the Receive E1 Framer Block will need to verify the correct frame alignment
for an additional two frames.
21
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 7: ALARM GENERATION REGISTER (AGR)
BIT
FUNCTION
HEX ADDRESS: 0Xn108
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
Transmit AUXP
Pattern
R/W
0
Transmit Auxiliary (AUXP) Pattern
This bit permits the user to command the Transmit E1 Framer block to
transmit the AUXP Pattern to the remote terminal equipment, as depicted
below.
0 - Configures the Transmit E1 Framer block to NOT transmit the AUXP
Pattern (which is an unframed, repeating 1010... pattern).
1 - Configures the Transmit E1 Framer block to transmit the AUXP Pattern.
The device also supports AUXP pattern detection, please read register
(address 0xnB0A) for more detail.
6
Loss of Frame
Declaration Criteria
R/W
0
Loss of Frame Declaration Criteria
This bit permits the user to select the “Loss of Frame Declaration Criteria”
for the Receive E1 Framer block, as depicted below.
0 = Loss of Frame is declared immediately if either CRC Multiframe Alignment or FAS Alignment is lost.
1 = Loss of Frame is declared immediately if FAS Alignment is lost. If CRC
Multiframe Alignment is lost for more than 8ms, E1 receive framer will
force a frame search.
5-4 Transmit YEL And
Multi-YEL[1:0]
R/W
00
Yellow Alarm and Multiframe Yellow Alarm Generation [1:0]
These bits activate or deactivate the transmission of yellow and multiframe
yellow alarm. The Yellow alarm and multiframe Yellow alarm can be forced
to transmit as’1’, or be inserted upon detection of loss of alignment. The
decoding of these bits are explained as follows:
YEL[1:0]
YELLOW ALARM TRANSMITTED
00/10
Yellow Alarm and Multiframe Yellow Alarm transmission
is disabled.
01
Automatic Transmission of Yellow and CAS Multiframe
Yellow Alarms are enabled, as described below:
1. Whenever the Receive E1 Framer block declares the
LOF (Loss of FAS Framing) defect condition:
The corresponding Transmit E1 Framer block will automatically transmit the Yellow Alarm indicator (by setting Bit 3 of
Time-Slot 0, within the non-FAS frames) to 1" whenever
(and for the duration that) the Receive E1 Framer block
declares the LOF defect condition.
2. Whenever the Receive E1 Framer block declares the
“Loss of CAS Multiframe Alignment” defect condition:
The corresponding Transmit E1 Framer block will automatically transmit the CAS Multiframe Yellow Alarm indicator (by
setting Bit 6 within “Frame 0" of Time-slot 16) to “1” whenever (and for the duration that) the Receive E1 Framer block
declares the Loss of CAS Multiframe Defect condition.
11
Force Transmission of Yellow and Multiframe Yellow
Alarm
Both Yellow and Multiframe Yellow Alarm are transmitted as
‘1’ when this is enabled.
22
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 7: ALARM GENERATION REGISTER (AGR)
BIT
FUNCTION
3-2 Transmit AIS Pattern Select[1:0]
REV. V1.2.1
HEX ADDRESS: 0Xn108
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
00
Types of AIS Pattern Generation Select
These bits permit the user to do the following.
a. To select the type of AIS Pattern that the Transmit E1 Framer block will
transmit.
b. To force (via Software-control) the transmission of the “selected” AIS
Pattern.
AISG[1:0]
TYPES OF AIS PATTERN TRANSMITTED
00
Transmission of AIS Indicator is Disabled
The Transmit E1 Framer block will transmit “normal” E1 traffic to the remote terminal equipment.
01
Unframed AIS alarm
Transmit E1 Framer block will transmit an
Unframed All Ones Pattern, as an AIS Pattern.
10
The AIS-16 Pattern
In this case, Time-slot 16 (within each outbound
E1 frame) will be set to an “All Ones” Pattern.
11
Framed AIS alarm
Transmit E1 Framer block will transmit a Framed
All Ones Pattern, as an AIS Pattern.
NOTE: For “normal” operation, the user should set these bits to “[0, 0]”.
1-0 AIS Defect Declaration Criteria[1:0]
R/W
00
AIS Defect Declaration Criteria[1:0]:
These bits permit the user to specify the types of AIS Patterns that the
Receive E1 Framer block must detect before it will declare the AIS defect
condition.
AISD[1:0]
AIS Defect Declaration Criteria
00
AIS Defect Condition will NOT be declared.
01
Receive E1 Framer block will detect both
Unframed and Framed AIS pattern
10
Receive E1 Framer block will detect AIS16 (Time
Slot 16 AIS) pattern*.
11
Receive E1 Framer block will detect only Framed
AIS pattern
NOTE: In revision C of XRT86VL38, Receive E1 framer will always monitor
AIS16 condition and report the state and interrupt status without
having to enable these two bits. AIS16 alarm state and interrupt
status can be read from register 0xnB12, 0xnB13.
23
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 8: SYNCHRONIZATION MUX REGISTER (SMR)
BIT
FUNCTION
7-6 E Bit Source Sel[1:0]
TYPE
DEFAULT
R/W
00
HEX ADDRESS: 0Xn109
DESCRIPTION-OPERATION
Source for E bits [1:0]
These bits permit the user to specify the source of the E-bits, within
each outbound E1 frame, as depicted below.
ESRC[1:0]
SOURCE FOR E-BITS
00
The corresponding Receive E1 Framer block:
In this case, the E-bits will be used to indicate
whether the Receive E1 Framer block has
detected a CRC error within the most recently
received Sub-Multiframe.
The Receive E1 Framer will indicate a received
errored sub-multiframe by setting the binary state
of E bit from ‘1’ to ‘0’ for each errored sub-multiframe.
01
All E bits (within the outbound E1 data-stream) are
set to “0”.
10
All E bits (within the outbound E1 data-stream) are
set to “1”.
11
The outgoing E bits will be used to carry data link
information.
NOTE: This bit is only active if the Transmit E1 Framer block has
been configured to internally generate and insert the various
Framing Alignment bits within the outbound E1 data-stream.
In other words, whenever the “Framing Alignment Pattern
Source Select” bit (within Bit 0 of this Register) is set to “0”.
5
Reserved
-
-
Reserved
24
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 8: SYNCHRONIZATION MUX REGISTER (SMR)
BIT
4
FUNCTION
Transmit Frame Sync
Select
REV. V1.2.1
HEX ADDRESS: 0Xn109
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Transmit Frame Sync Select
This bit permits the user to configure the System-Side Terminal
Equipment or the E1 Transmit Framer to dictate whenever the Transmit E1 Framer block will initiate its generation and transmission of
the very next E1 frame. If the system side controls, then all of the following will be true.
1. The corresponding TxSync_n and TxMSync_n pins will function
as input pins.
2. The Transmit E1 Framer block will initiate its generation of a new
E1 frame whenever it samples the corresponding “TxSync_n” input
pin “high” (via the TxSerClk_n input clock signal).
3. The Transmit E1 Framer block will initiate its generation of a new
CRC Multiframe whenever it samples the corresponding
“TxMSync_n” input pin “high”.
This bit can also be used to select the direction of the transmit single
frame boundary (TxSYNC) and multi-frame boundary (TxMSYNC)
depending on whether TxSERCLK is chosen as the timing source for
the transmit section of the framer. (CSS[1:0] = 01 in register 0xn100)
If TxSERCLK is chosen as the timing source:
0 = Configures TxSYNC and TxMSYNC as inputs. (System Side
Controls)
1 = Configures TxSYNC and TxMSYNC as outputs. (Chip Controls)
If either Recovered Line Clock, MCLK PLL is chosen as the timing source:
0 = Configures TxSYNC and TxMSYNC as outputs. (Chip Controls)
1 = Configures TxSYNC and TxMSYNC as inputs. (System Side
Controls)
NOTE: TxSERCLK is chosen as the transmit clock if CSS[1:0] of the
Clock Select Register (Register Address: 0xn100) is set to
b01. Recovered Clock is chosen as the transmit clock if
CSS[1:0] is set to b00 or b11; Internal Clock is chosen as the
transmit clock if CSS[1:0] is set to b10.
3-2 Data Link Source
Select [1:0]
R/W
00
Data Link Source Select
These bits are used to specify the source of the Data Link bits that
will be inserted in the outbound E1 frames. The table below
describes the three different sources from which the Data Link bits
can be inserted.
DLSRC[1:0]
00/11
SOURCE OF DATA LINK BITS
TxSER Input - The transmit serial input from the
transmit payload data input block will be the
source for data link bits
01
Transmit HDLC Controller - The Transmit HDLC
Controller will generate either BOS (Bit Oriented
Signaling) or MOS (Message Oriented Signaling)
messages which will be inserted into the Data Link
bits in the outbound E1frames.
10
TxOH Input - The Transmit Overhead data Input
Port will be the source for the Data Link bits.
25
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 8: SYNCHRONIZATION MUX REGISTER (SMR)
HEX ADDRESS: 0Xn109
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
1
CRC-4 Bits Source Sel
R/W
0
CRC-4 Bits Source Select
This bit permits the user to specify the source of the CRC-4 bits,
within the outbound E1 data-stream, as depicted below.
0 - Configures the Transmit E1 Framer block to internally compute
and insert the CRC-4 bits within the outbound E1 data-stream.
1 - Configures the Transmit E1 Framer block to externally accept
data from the TxSer_n input pin, and to insert this data into the CRC4 bits within the outbound E1 data-stream.
NOTE: This bit is ignored if CRC Multiframe Alignment is disabled
0
Framing Alignment Pattern Source Select
R/W
0
Framing Alignment Pattern Source Select
This bit permits the user to specify the source of the various “Framing Alignment” bits (which includes the FAS bits, the CRC Multiframe
Alignment bits, the E and A bits).
0 - Configures the Transmit E1 Framer block to internally generate
and insert these various framing alignment bits into the outbound E1
data-stream.
1 - Configures the Transmit E1 Framer block to externally accept
data from the TxSer_n input pin, and to insert this data into the FAS,
CRC Multiframe, E and A bits within the outbound E1 data-stream.
NOTE: Users can specify the source for E-bits in register bits 6-7
within this register if Transmit E1 Framer is configured to
internally generate the various framing alignment bits (i.e.
this bit set to’0’).
26
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 9: TRANSMIT SIGNALING AND DATA LINK SELECT REGISTER (TSDLSR)
BIT
7
FUNCTION
TxSa8ENB
REV. V1.2.1
HEX ADDRESS:0Xn10A
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Transmit Sa8 Enable
This bit specifies if the Sa8 bits (bit 7 within timeslot 0 of non-FAS frames) will be
involved in the transmission of Data Link Information.
0 = Sa8 will NOT be used to transport Data Link Information. Sa8 bits will be set to
“1” within the outbound E1 data-stream if the Sa8 bits are inserted from the transmit serial input.
1 = Sa8 WILL be used to transport Data Link Information.
NOTE: Sa8 bits can be inserted from either the transmit serial input or register
depending on the Transmit SA Select Register (Register Address:
0xn130) setting. The data link interface uses Sa8 bits for transmission
only if Data Link source is from HDLC controller (DLSRC = b01 from
Register 0xn109) and if Sa8 bits are inserted from the transmit serial input
(TxSa8SEL = 0 from Register 0xn130).
6
TxSa7ENB
R/W
0
Transmit Sa7 Enable
This bit specifies if the Sa7 bits (bit 6 within timeslot 0 of non-FAS frames) will be
involved in the transmission of Data Link Information.
0 = Sa7 will NOT be used to transport Data Link Information. Sa7 bits will be set to
“1” within the outbound E1 data-stream if the Sa7 bits are inserted from the transmit serial input.
1 = Sa7 WILL be used to transport Data Link Information.
NOTE: Sa7 bits can be inserted from either the transmit serial input or register
depending on the Transmit SA Select Register (Register Address:
0xn130) setting. The data link interface uses Sa8 bits for transmission
only if Data Link source is from HDLC controller (DLSRC = b01 from
Register 0xn109) and if Sa7 bits are inserted from the transmit serial input
(TxSa7SEL = 0 from Register 0xn130).
5
TxSa6ENB
R/W
0
Transmit Sa6 Enable
This bit specifies if the Sa6 bits (bit 5 within timeslot 0 of non-FAS frames) will be
involved in the transmission of Data Link Information.
0 = Sa6 will NOT be used to transport Data Link Information. Sa6 bits will be set to
“1” within the outbound E1 data-stream if the Sa6 bits are inserted from the transmit serial input.
1 = Sa6 WILL be used to transport Data Link Information.
NOTE: Sa6 bits can be inserted from either the transmit serial input or register
depending on the Transmit SA Select Register (Register Address:
0xn130) setting. The data link interface uses Sa6 bits for transmission
only if Data Link source is from HDLC controller (DLSRC = b01 from
Register 0xn109) and if Sa6 bits are inserted from the transmit serial input
(TxSa6SEL = 0 from Register 0xn130).
4
TxSa5ENB
R/W
0
Transmit Sa5 Enable
This bit specifies if the Sa5 bits (bit 4 within timeslot 0 of non-FAS frames) will be
involved in the transmission of Data Link Information.
0 = Sa5 will NOT be used to transport Data Link Information. Sa5 bits will be set to
“1” within the outbound E1 data-stream if the Sa5 bits are inserted from the transmit serial input.
1 = Sa5 WILL be used to transport Data Link Information.
Sa5 bits can be inserted from either the transmit serial input or register depending
on the Transmit SA Select Register (Register Address: 0xn130) setting. The data
link interface uses Sa5 bits for transmission only if Data Link source is from HDLC
controller (DLSRC = b01 from Register 0xn109) and if Sa5 bits are inserted from
the transmit serial input (TxSa5SEL = 0 from Register 0xn130).
27
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 9: TRANSMIT SIGNALING AND DATA LINK SELECT REGISTER (TSDLSR)
BIT
3
FUNCTION
TxSa4ENB
HEX ADDRESS:0Xn10A
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Transmit Sa4 Enable
This bit specifies if the Sa4 bits (bit 3 within timeslot 0 of non-FAS frames) will be
involved in the transmission of Data Link Information.
0 = Sa4 will NOT be used to transport Data Link Information. Sa4 bits will be set to
“1” within the outbound E1 data-stream if the Sa4 bits are inserted from the transmit serial input.
1 = Sa4 WILL be used to transport Data Link Information.
Sa4 bits can be inserted from either the transmit serial input or register depending
on the Transmit SA Select Register (Register Address: 0xn130) setting. The data
link interface uses Sa4 bits for transmission only if Data Link source is from HDLC
controller (DLSRC = b01 from Register 0xn109) and if Sa4 bits are inserted from
the transmit serial input (TxSa5SEL = 0 from Register 0xn130).
28
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 9: TRANSMIT SIGNALING AND DATA LINK SELECT REGISTER (TSDLSR)
BIT
FUNCTION
2-0 TxSIGDL[2:0]
TYPE
DEFAULT
R/W
000
HEX ADDRESS:0Xn10A
DESCRIPTION-OPERATION
Transmit Signaling and Data Link Select[2:0]:
These bits are used to specify the source for D/E channel, National Bits in
timeslot 0 of the non-FAS frames, and Timeslot 16 of the outbound E1
frames. The table below presents the settings of these three bits in detail.
TXSIGDL
[2:0]
SOURCE OF SOURCE OF
NATIONAL
D/E CHANNEL
BITS
SOURCE OF
TIMESLOT 16
000
TxFrTD_n or
TxSer_n
input pin
Data link
TxSer_n input pin
001
TxFrTD_n or
TxSer_n
input pin
Data link
CAS signaling is enabled. Time Slot
16 can be inserted from any of the following:
• TxSer_n input pin
• TSCR Register (0xn340-0xn35F)
• TxOH_n input pin on time slot 16
only
• TxSIG_n input pin on every slot
010
TxFrTD_n or
TxSer_n
input pin
Forced to
All Ones
TxSER_n input pin or
TxSIG_n input pin on time slot 16 only
011
TxFrTD_n or
TxSer_n
input pin
Forced to
All Ones
CAS signaling is enabled. Time Slot
16 can be inserted from any of the following:
• TxSer_n input pin
• TSCR Register (0xn340-0xn35F)
• TxOH_n input pin on time slot 16
only
• TxSIG_n input pin on every slot
100
TxSIG_n or
TxSer_n
input pin
Data link
TxSer_n input pin
101/
110/
Not Used
Not Used
Not Used
29
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 10: FRAMING CONTROL REGISTER (FCR)
BIT
7
FUNCTION
Reframe
6-5 Loss of CAS MF
Align_Sel [1:0]
HEX ADDRESS: 0Xn10B
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Force Reframe
A ‘0’ to ‘1’ transition will force the Receive E1 Framer to restart the synchronization process. This bit field is automatically cleared (set to 0)
after frame synchronization is reached.
R/W
10
Loss of CAS Multiframe Alignment Defect Declaration Criteria
Select [1:0]
These two bits permit the user to select the “Loss of CAS Multiframe
Alignment” defect declaration criteria. Loss of CAS Multiframe Alignment defect is declared based on the number of consecutive CAS multiframes with Multiframe Alignment signal received in error as indicated
in the table below.
CASC[1:0]
NOTE:
4-3 Loss of CRC Multiframe Align_Sel[1:0]
R/W
00
LOSS OF CAS MULTIFRAME ALIGNMENT
DECLARATION CRITERIA
00
2 consecutive CAS Multiframes
01
3 consecutive CAS Multiframes
10
4 consecutive CAS Multiframes
11
8 consecutive CAS Multiframes
These bits are active only if CAS Multiframe Alignment is
enabled.
Loss of CRC-4 Multiframe Alignment Defect Declaration Criteria
Select [1:0]
These two bits permit the user to select the “Loss of CRC-4 Multiframe
Alignment” defect declaration criteria for the Channel. The following
table presents the different CRC-4 Multiframe Algorithms in terms of
the number of consecutive erred CRC-4 multiframe alignments that the
E1 Receiver Framer will receive before it declares the “Loss of CRC-4
Multiframe Alignment” defect condition.
CASC[1:0]
NOTE:
LOSS OF CRC-4 MULTIFRAME ALIGNMENT
DECLARATION CRITERIA
00
4 consecutive CRC-4 Multiframes Alignment
01
2 consecutive CRC-4 Multiframes Alignment
10
8 consecutive CRC-4 Multiframes Alignment
11
If TBR-4 Standard is Enabled*:
4 consecutive CRC-4 Multiframe Alignment or 915
or more CRC-4 errors
If TBR-4 Standard is Disabled*:
915 or more CRC-4 errors
These bits are only active if CRC Multiframe Alignment is
enabled. If CRC multiframe alignment is not found in 8ms, the
E1 receive framer will restart the synchronization process.
NOTE: TBR-4 standard is enabled by writing to 0xn112, bit 6.
30
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 10: FRAMING CONTROL REGISTER (FCR)
BIT
FUNCTION
2-0 LOF_Declare_Sel
[2:0]
REV. V1.2.1
HEX ADDRESS: 0Xn10B
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
011
Loss of FAS Alignment Defect Declaration Criteria Select [2:0]
These bits permit the user to specify the Loss of FAS Alignment defect
declaration criteria. The following table presents the different FAS
Alignment Algorithms in terms of the number of consecutive erred FAS
patterns within a multiframe that the E1 Receiver Framer will receive
before it declares the “Loss of FAS Alignment” defect conditions
FASC[2:0]
NOTE:
LOSS OF FAS ALIGNMENT DECLARATION CRITERIA
000
Setting these bits to ‘b000’ is illegal. Do not use
this configuration.
001
1 FAS Alignment pattern
010
2 consecutive FAS Alignment patterns
011
3 consecutive FAS Alignment patterns
100
4 consecutive FAS Alignment patterns
101
5 consecutive FAS Alignment patterns
110
6 consecutive FAS Alignment patterns
111
7 consecutive FAS Alignment patterns
Loss of FAS alignment will force the E1 receive framer to
declare the loss of CAS multiframe alignment and loss of CRC
multiframe alignment.
31
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 11: RECEIVE SIGNALING & DATA LINK SELECT REGISTER (RSDLSR)
BIT
7
FUNCTION
RxSa8ENB
HEX ADDRESS: 0Xn10C
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Receive Sa8 Enable
This bit is used to specify whether or not Sa 8 (bit 7 within timeslot 0 of non-FAS
frames) will be used to receive data link information
0 = Sa8 is not used to receive data link information
1 = Sa8 is used to receive data link information
NOTE: This bit is valid only if the RxSIGDL[2:0] = “000”, “001”, or “100”. (The
National bits have been configured to receive data link bits).
6
RxSa7ENB
R/W
0
Receive Sa7 Enable
This bit is used to specify whether or not Sa 7 (bit 6 within timeslot 0 of non-FAS
frames) will be used to receive data link information
0 = Sa7 is not used to receive data link information
1 = Sa7 is used to receive data link information
NOTE: This bit is valid only if the RxSIGDL[2:0] = “000”, “001”, or “100”. (The
National bits have been configured to receive data link bits).
5
RxSa6ENB
R/W
0
Receive Sa6 Enable
This bit is used to specify whether or not Sa 6 (bit 5 within timeslot 0 of non-FAS
frames) will be used to receive data link information
0 = Sa6 is not used to receive data link information
1 = Sa6 is used to receive data link information
NOTE: This bit is valid only if the RxSIGDL[2:0] = “000”, “001”, or “100”. (The
National bits have been configured to receive data link bits).
4
RxSa5ENB
R/W
0
Receive Sa5 Enable
This bit is used to specify whether or not Sa 5 (bit 4 within timeslot 0 of non-FAS
frames) will be used to receive data link information
0 = Sa5 is not used to receive data link information
1 = Sa5 is used to receive data link information
NOTE: This bit is valid only if the RxSIGDL[2:0] = “000”, “001”, or “100”. (The
National bits have been configured to receive data link bits).
3
RxSa4ENB
R/W
0
Receive Sa4 Enable
This bit is used to specify whether or not Sa 4 (bit 3 within timeslot 0 of non-FAS
frames) will be used to receive data link information
0 = Sa4 is not used to receive data link information
1 = Sa4 is used to receive data link information
NOTE: This bit is valid only if the RxSIGDL[2:0] = “000”, “001”, or “100”. (The
National bits have been configured to receive data link bits).
32
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 11: RECEIVE SIGNALING & DATA LINK SELECT REGISTER (RSDLSR)
BIT
FUNCTION
2-0 RxSIGDL[2:0]
TYPE
DEFAULT
R/W
000
HEX ADDRESS: 0Xn10C
DESCRIPTION-OPERATION
Receive Signaling and Datalink Select[2:0]:
These bits specify the destination for the data that is to be extracted via D/E
channel, National Bits in timeslot 0 of the non-FAS frames, and Timeslot 16 in
the outbound frames. The table below presents the settings of these three
RxSIGDL bits in detail.
RXSIGDL
[2:0]
D/E CHANNEL
NATIONAL BITS
TIME SLOT 16
000
RxFrTD_n or the
RxSer_n
output pin
Data Link
RxSER_n output pin
001
RxFrTD_n or the
RxSer_n
output pin
Data Link
CAS signaling is enabled. Time
Slot 16 can be extracted to any
of the following:
• RxSer_n output pin
• RSAR Register
(0xn500-0xn51F)
• RxOH_n output pin on time
slot 16 only
• RxSIG_n output pin on every
time slot
010
RxFrTD_n or the
RxSer_n
output pin
Data Link
forced to All
Ones
Time Slot 16 can be extracted
to any of the following:
• RxSer_n output pin
• RSAR Register
(0xn500-0xn51F)
• RxOH_n output pin on time
slot 16 only
• RxSIG_n output pin on time
slot 16 only
011
RxFrTD_n or the
RxSer_n
output pin
Data Link
forced to All
Ones
CAS signaling is enabled. Time
Slot 16 can be extracted to any
of the following:
• RxSer_n output pin
• RSAR Register
(0xn500-0xn51F)
• RxOH_n output pin on time
slot 16 only
RxSIG_n output pin on every
time slot
100
RxSIG_n or the
RxSer_n
output pin
101/110/ Not Used
111
33
Data Link
RxSER_n output pin
Not Used
Not Used
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 12: RECEIVE SIGNALING CHANGE REGISTER 0 (RSCR 0)
BIT
FUNCTION
TYPE
DEFAULT
7
Ch. 0
RUR
0
6
Ch. 1
RUR
0
5
Ch.2
RUR
0
4
Ch.3
RUR
0
3
Ch.4
RUR
0
2
Ch.5
RUR
0
1
Ch.6
RUR
0
0
Ch.7
RUR
0
DESCRIPTION-OPERATION
These bits indicate whether the Channel Associated signaling data,
associated with Time-Slots 0 through 7 within the incoming E1 datastream, has changed since the last read of this register, as depicted
below.
0 - CAS data (for Time-slots 0 through 7) has NOT changed since the
last read of this register.
1 - CAS data (for Time-slots 0 through 7) HAS changed since the last
read of this register.
NOTES: 1. Bit 7 (Time-Slot 0) is NOT active, since it carries the FAS and
National Bits.
NOTE: 2. This register is only active if the incoming E1 data-stream is
using Channel Associated Signaling.
TABLE 13: RECEIVE SIGNALING CHANGE REGISTER 1 (RSCR 1)
BIT
FUNCTION
DEFAULT
DESCRIPTION-OPERATION
These bits indicate whether the Channel Associated signaling data,
associated with Time-Slots 8 through 15 within the incoming E1 datastream, has changed since the last read of this register, as depicted
below.
0 - CAS data (for Time-slots 8 through 15) has NOT changed since the
last read of this register.
1 - CAS data (for Time-slots 8 through 15) HAS changed since the last
read of this register.
Ch.8
RUR
0
6
Ch.9
RUR
0
5
Ch.10
RUR
0
4
Ch.11
RUR
0
3
Ch.12
RUR
0
2
Ch.13
RUR
0
1
Ch.14
RUR
0
0
Ch.15
RUR
0
NOTE: This register is only active if the incoming E1 data-stream is
using Channel Associated Signaling.
TABLE 14: RECEIVE SIGNALING CHANGE REGISTER 2 (RSCR 2)
FUNCTION
HEX ADDRESS: 0Xn10E
TYPE
7
BIT
HEX ADDRESS: 0Xn10D
HEX ADDRESS: 0Xn10F
TYPE
DEFAULT
DESCRIPTION-OPERATION
These bits indicate whether the Channel Associated signaling data,
associated with Time-Slots 16 through 23 within the incoming E1 datastream, has changed since the last read of this register, as depicted
below.
0 - CAS data (for Time-slots 16 through 23) has NOT changed since
the last read of this register.
1 - CAS data (for Time-slots 16 through 23) HAS changed since the
last read of this register.
7
Ch.16
RUR
0
6
Ch.17
RUR
0
5
Ch.18
RUR
0
4
Ch.19
RUR
0
3
Ch.20
RUR
0
2
Ch.21
RUR
0
1
Ch.22
RUR
0
0
Ch.23
RUR
0
NOTE: This register is only active if the incoming E1 data-stream is
using Channel Associated Signaling.
34
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 15: RECEIVE SIGNALING CHANGE REGISTER 3 (RSCR 3)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0Xn110
TYPE
DEFAULT
DESCRIPTION-OPERATION
These bits indicate whether the Channel Associated signaling data,
associated with Time-Slots 24 through 31 within the incoming E1
data-stream, has changed since the last read of this register, as
depicted below.
0 - CAS data (for Time-slots 24 through 31) has NOT changed since
the last read of this register.
1 - CAS data (for Time-slots 24 through 31) HAS changed since the
last read of this register.
7
Ch.24
RUR
0
6
Ch.25
RUR
0
5
Ch.26
RUR
0
4
Ch.27
RUR
0
3
Ch.28
RUR
0
2
Ch.29
RUR
0
1
Ch.30
RUR
0
0
Ch.31
RUR
0
NOTE: This register is only active if the incoming E1 data-stream is
using Channel Associated Signaling.
35
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 16: RECEIVE NATIONAL BITS REGISTER (RNBR)
BIT
FUNCTION
TYPE
DEFAULT
HEX ADDRESS: 0Xn111
DESCRIPTION-OPERATION
7
Si_FAS
RO
x
Received International Bit - FAS Frame
This Read Only bit contains the value of the International Bit (e.g.,
the Si bit) in the most recently received FAS frame.
6
Si_nonFAS
RO
x
Received International Bit - Non FAS Frame
This Read Only bit contains the value of the International Bit (e.g.,
the Si bit) in the most recently received non-FAS frame
5
R_ALARM
RO
x
Received A bit - Non FAS Frame
This Read Only bit contains the value in the Remote Alarm Indication
bit (A bit, or bit 3 of non-FAS frame) within the most recently received
non-FAS frame.
4
Sa4
RO
x
3
Sa5
RO
x
Received National Bits
These Read Only bits contain the values of the National bits (Sa4Sa8) within the most recently received non-FAS frame.
2
Sa6
RO
x
1
Sa7
RO
x
0
Sa8
RO
x
36
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 17: RECEIVE EXTRA BITS REGISTER (REBR)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0Xn112
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
In-Frame
RO
0
In Frame State:
This READ-ONLY bit indicates whether the Receive E1 Framer block is
currently declaring the “In-Frame” condition with the incoming E1 datastream.
0 - Indicates that the Receive E1 Framer block is currently declaring the
LOF (Loss of Frame) Defect condition.
1 - Indicates that the Receive E1 Framer block is currently declaring itself
to be in the “In-Frame” condition.
6
TBR4_Std
R/W
0
TBR4 Standard
Setting this bit will force the XRT86VL38 to be compliant with the TBR-4
standard for “Loss of CRC-4 Multiframe Alignment Criteria”.
0 - Backward compatible with XRT86L38 for Loss of CRC-4 Multiframe
Criteria. When CRCC[1:0] (from register 0xn10B) is set to’11’, Loss of
CRC-4 Multiframe Alignment will declare if 915 or more CRC-4 errors
have been detected in 1 second.
1 - “TBR-4 Compliant” Loss of CRC-4 Multiframe Alignment Criteria When CRCC[1:0] (from register 0xn10B) is set to’11’, Loss of CRC-4 Multiframe Alignment will declare if 4 consecutive CRC-4 Multiframe Alignment have been received in error OR if 915 or more CRC-4 errors have
been detected in 1 second.
-
-
Reserved
RO
x
Extra Bit 1
This READ ONLY bit field indicates the value of the most recently
received Extra Bit value (bit 5 within timeslot 16 of frame 0 of the signaling multiframe).
5-4 Reserved
3
EX1
NOTE:
2
ALARMFE
RO
x
This bit only has meaning if the framer is using Channel
Associated Signaling.
CAS Multi-Frame Yellow Alarm
This READ ONLY bit field indicates the value of the most recently
received CAS Multiframe Yellow Alarm Bit (bit 6 within timeslot 16 of
frame 0 of the signaling multiframe).
0 = Indicates that the E1 receive framer block is NOT receiving the CAS
Multiframe Yellow Alarm.
1 = Indicates that the E1 receive framer block is currently receiving the
CAS Multiframe Yellow Alarm.
NOTE:
This bit only has meaning if the framer is using Channel
Associated Signaling.
37
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 17: RECEIVE EXTRA BITS REGISTER (REBR)
BIT
1
FUNCTION
EX2
TYPE
DEFAULT
DESCRIPTION-OPERATION
RO
x
Extra Bit 2
This READ ONLY bit field indicates the value of the most recently
received Extra Bit value (bit 7 within timeslot 16 of frame 0 of the signaling multiframe).
NOTE:
0
EX3
HEX ADDRESS: 0Xn112
RO
x
This bit only has meaning if the framer is using Channel
Associated Signaling.
Extra Bit 3
This READ ONLY bit field indicates the value of the most recently
received Extra Bit value (bit 8 within timeslot 16 of frame 0 of the signaling multiframe).
NOTE:
This bit only has meaning if the framer is using Channel
Associated Signaling.
38
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 18: DATA LINK CONTROL REGISTER (DLCR1)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0Xn113
TYPE
DEFAULT
DESCRIPTION-OPERATION
-
-
Reserved. Please set this bit to’0’ for normal operation.
7
Reserved
6
MOS ABORT Disable
R/W
0
MOS ABORT Disable:
This bit permits the user to either enable or disable the “Automatic
MOS ABORT” feature within Transmit HDLC Controller # 1. If the
user enables this feature, then Transmit HDLC Controller block # 1
will automatically transmit the ABORT Sequence (e.g., a zero followed by a string of 7 consecutive “1s”) whenever it abruptly transitions from transmitting a MOS type of message, to transmitting a
BOS type of message.
If the user disables this feature, then the Transmit HDLC Controller
Block # 1 will NOT transmit the ABORT sequence, whenever it
abruptly transitions from transmitting a MOS-type of message to
transmitting a BOS-type of message.
0 - Enables the “Automatic MOS Abort” feature
1 - Disables the “Automatic MOS Abort” feature
5
Rx_FCS_DIS
R/W
0
Receive Frame Check Sequence (FCS) Verification Enable/Disable
This bit permits the user to configure the Receive HDLC Controller
Block # 1 to compute and verify the FCS value within each incoming
LAPD message frame.
0 - Enables FCS Verification
1 - Disables FCS Verification
4
AutoRx
R/W
0
Auto Receive LAPD Message
This bit configures the Receive HDLC Controller Block #1 to discard
any incoming BOS or LAPD Message frame that exactly match
which is currently stored in the Receive HDLC1 buffer.
0 = Disables this “AUTO DISCARD” feature
1 = Enables this “AUTO DISCARD” feature.
3
Tx_ABORT
R/W
0
Transmit ABORT
This bit configures the Transmit HDLC Controller Block #1 to transmit an ABORT sequence (string of 7 or more consecutive 1’s) to the
Remote terminal.
0 - Configures the Transmit HDLC Controller Block # 1 to function
normally (e.g., not transmit the ABORT sequence).
1 - Configures the Transmit HDLC Controller block # 1 to transmit
the ABORT Sequence.
39
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 18: DATA LINK CONTROL REGISTER (DLCR1)
BIT
2
FUNCTION
Tx_IDLE
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Transmit Idle (Flag Sequence Byte)
This bit configures the Transmit HDLC Controller Block #1 to unconditionally transmit a repeating string of Flag Sequence octets (0X7E)
in the data link channel to the Remote terminal. In normal conditions, the Transmit HDLC Controller block will repeatedly transmit
the Flag Sequence octet whenever there is no MOS message to
transmit to the remote terminal equipment. However, if the user
invokes this “Transmit Idle Sequence” feature, then the Transmit
HDLC Controller block will UNCONDITIONALLY transmit a repeating stream of the Flag Sequence octet (thereby overwriting all outbound MOS data-link messages).
0 - Configures the Transmit HDLC Controller Block # 1 to transmit
data-link information in a “normal” manner.
1 - Configures the Transmit HDLC Controller block # 1 to transmit a
repeating string of Flag Sequence Octets (0x7E).
NOTE:
1
Tx_FCS_EN
HEX ADDRESS: 0Xn113
R/W
0
This bit is ignored if the Transmit HDLC1 controller is
operating in the BOS Mode - bit 0 (MOS/BOS) within this
register is set to 0.
Transmit LAPD Message with Frame Check Sequence (FCS)
This bit permits the user to configure the Transmit HDLC Controller
block # 1 to compute and append FCS octets to the “back-end” of
each outbound MOS data-link message.
0 - Configures the Transmit HDLC Controller block # 1 to NOT compute and append the FCS octets to the back-end of each outbound
MOS data-link message.
1 - Configures the Transmit HDLC Controller block # 1 TO COMPUTE and append the FCS octets to the back-end of each outbound
MOS data-link message.
NOTE: This bit is ignored if the transmit HDLC1 controller has been
configured to operate in the BOS mode - bit 0 (MOS/BOS)
within this register is set to 0.
0
MOS/BOS
R/W
0
Message Oriented Signaling/Bit Oriented Signaling Send
This bit permits the user to enable LAPD transmission through
HDLC Controller Block # 1 using either BOS (Bit-Oriented Signaling)
or MOS (Message-Oriented Signaling) frames.
0 - Transmit HDLC Controller block # 1 BOS message Send.
1 - Transmit HDLC Controller block # 1 MOS message Send.
NOTE: This is not an Enable bit. This bit must be set to "0" each time
a BOS is to be sent.
40
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 19: TRANSMIT DATA LINK BYTE COUNT REGISTER (TDLBCR1)
BIT
7
FUNCTION
TxHDLC1 BUFAvail/
BUFSel
REV. V1.2.1
HEX ADDRESS: 0Xn114
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Transmit HDLC1 Buffer Available/Buffer Select
This bit has different functions, depending upon whether the user is
writing to or reading from this register, as depicted below.
If the user is writing data into this register bit:
0 - Configures the Transmit HDLC1 Controller to read out and transmit the data, residing within “Transmit HDLC1 Buffer # 0", via the
Data Link channel to the remote terminal equipment.
1 - Configures the Transmit HDLC1 Controller to read out and transmit the data, residing within the “Transmit HDLC1 Buffer #1”, via the
Data Link channel to the remote terminal equipment.
If the user is reading data from this register bit:
0 - Indicates that “Transmit HDLC1 Buffer # 0" is the next available
buffer. In this case, if the user wishes to write in the contents of a
new “outbound” Data Link Message into the Transmit HDLC1 Message Buffer, he/she should proceed to write this message into
“Transmit HDLC1 Buffer # 0" - Address location: 0xn600.
1 - Indicates that “Transmit HDLC1 Buffer # 1" is the next available
buffer. In this case, if the user wishes to write in the contents of a
new “outbound” Data Link Message into the Transmit HDLC1 Message Buffer, he/she should proceed to write this message into
“Transmit HDLC1 Buffer # 1" - Address location: 0xn700.
NOTE: If one of these Transmit HDLC1 buffers contain a message
which has yet to be completely read-in and processed for
transmission by the Transmit HDLC1 controller, then this bit
will automatically reflect the value corresponding to the next
available buffer when it is read. Changing this bit to the inuse buffer is not permitted.
6-0 TDLBC[6:0]
R/W
0000000 Transmit HDLC1 Message - Byte Count
The exact function of these bits depends on whether the Transmit
HDLC 1 Controller is configured to transmit MOS or BOS messages
to the Remote Terminal Equipment.
In BOS MODE:
These bit fields contain the number of repetitions the BOS message
must be transmitted before the Transmit HDLC1 controller generates the Transmit End of Transfer (TxEOT) interrupt and halts transmission. If these fields are set to 00000000, then the BOS message
will be transmitted for an indefinite number of times.
In MOS MODE:
These bit fields contain the length, in number of octets, of the message to be transmitted. The length of MOS message specified in
these bits include header bytes such as the SAPI, TEI, Control field,
however, it does not include the FCS bytes.
41
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 20: RECEIVE DATA LINK BYTE COUNT REGISTER (RDLBCR1)
BIT
7
FUNCTION
RBUFPTR
6-0 RDLBC[6:0]
HEX ADDRESS: 0Xn115
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Receive HDLC1 Buffer-Pointer
This bit Identifies which Receive HDLC1 buffer contains the most
recently received HDLC1 message.
0 - Indicates that Receive HDLC1 Buffer # 0 contains the contents of
the most recently received HDLC message.
1 - Indicates that Receive HDLC1 Buffer # 1 contains the contents of
the most recently received HDLC message.
R/W
0000000 Receive HDLC Message - byte count
The exact function of these bits depends on whether the Receive
HDLC Controller Block #1 is configured to receive MOS or BOS
messages.
In BOS Mode:
These seven bits contain the number of repetitions the BOS message must be received before the Receive HDLC1 controller generates the Receive End of Transfer (RxEOT) interrupt. If these bits are
set to “0000000”, the message will be received indefinitely and no
Receive End of Transfer (RxEOT) interrupt will be generated.
In MOS Mode:
These seven bits contain the size in bytes of the HDLC1 message
that has been received and written into the Receive HDLC buffer.
The length of MOS message shown in these bits include header
bytes such as the SAPI, TEI, Control field, AND the FCS bytes.
42
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 21: SLIP BUFFER CONTROL REGISTER (SBCR)
BIT
7
FUNCTION
TYPE
DEFAULT
TxSB_ISFIFO
R/W
0
REV. V1.2.1
HEX ADDRESS: 0Xn116
DESCRIPTION-OPERATION
Transmit Slip Buffer Mode
This bit permits the user to configure the Transmit Slip Buffer to function
as either “Slip-Buffer” Mode, or as a “FIFO”, as depicted below.
0 - Configures the Transmit Slip Buffer to function as a “Slip-Buffer”.
1 - Configures the Transmit Slip Buffer to function as a “FIFO”.
NOTE: Transmit slip buffer is only used in high-speed or multiplexed mode
where TxSERCLKn must be configured as inputs only. Users
must make sure that the “Transmit Direction” timing (i.e.
TxMSYNC) and the TxSerClk input clock signal are synchronous
to prevent any transmit slips from occurring.
NOTE: The data latency is dictated by FIFO Latency in the FIFO Latency
Register (register 0xn117).
6-5 Reserved
-
-
Reserved
4
SB_FORCESF
R/W
0
Force Signaling Freeze
This bit permits the user to freeze any signaling update on the RxSIGn
output pin as well as the Receive Signaling Array Register -RSAR
(0xn500-0xn51F) until this bit is cleared.
0 = Signaling on RxSIG and RSAR is updated immediately.
1 = Signaling on RxSIG and RSAR is not updated until this bit is set to ‘0’.
3
SB_SFENB
R/W
0
Signal Freeze Enable Upon Buffer Slips
This bit enables signaling freeze for one multiframe after the receive buffer
slips.
If signaling freeze is enabled, then the “Receive Channel” will freeze all
signaling updates on RxSIG pin and RSAR (0xn500-0xn51F) for at least
“one-multiframe” period, after a “slip-event” has been detected within the
“Receive Slip Buffer”.
0 = Disables signaling freeze for one multi-frame after receive buffer slips.
1 = Enables signaling freeze for one multi-frame after receive buffer slips.
2
SB_SDIR
R/W
1
Slip Buffer (RxSync) Direction Select
This bit permits user to select the direction of the receive frame boundary
(RxSYNC) signal if the receive buffer is enabled. (i.e. SB_ENB[1:0] = 01 or
10). If slip buffer is bypassed, RxSYNC is always an output pin.
0 = Selects the RxSync signal as an output
1 = Selects the RxSync signal as an input
43
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 21: SLIP BUFFER CONTROL REGISTER (SBCR)
BIT
FUNCTION
1-0 SB_ENB[1:0]
HEX ADDRESS: 0Xn116
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
01
Receive Slip Buffer Mode Select
These bits select modes of operation for the receive slip buffer. These two
bits also select the direction of RxSERCLK and RxSYNC in base clock
rate (2.048MHz). The following table shows the corresponding slip buffer
modes as well as the direction of the RxSYNC/RxSERCLK according to
the setting of these two bits.
SB_ENB RECEIVE SLIP BUFFER DIRECTION OF
MODE SELECT
RXSERCLK
[1:0]
00/11
DIRECTION OF
RXSYNC
Receive Slip Buffer is Output
bypassed
Output
01
Slip Buffer Mode
Input
Depends on the
setting of SB_SDIR
(bit 2 of this register)
If SB_SDIR = 0:
RxSYNC = Output
If SB_SDIR = 1:
RxSYNC = Input
10
FIFO Mode.
Input
FIFO data latency
can be programmed
by the 'FIFO Latency
Register' (Address =
0xn117).
Depends on the
setting of SB_SDIR
(bit 2 of this register)
If SB_SDIR = 0:
RxSYNC = Output
If SB_SDIR = 1:
RxSYNC = Input
NOTE: If the user configures the Receive Slip Buffer to operate in the
“FIFO Mode”, then the user must make sure that the RxSerClk
input pin is synchronized to the Recovered Clock signal for this
particular channel.
TABLE 22: FIFO LATENCY REGISTER (FFOLR)
BIT
FUNCTION
7-5 Reserved
4-0 Rx Slip Buffer FIFO
Latency[4:0]
TYPE
DEFAULT
-
-
R/W
00100
HEX ADDRESS: 0Xn117
DESCRIPTION-OPERATION
Reserved
Receive Slip Buffer FIFO Latency[4:0]:
These bits permit the user to specify the “Receive Data” Latency (in
terms of RxSerClk_n clock periods), whenever the Receive Slip
Buffer has been configured to operate in the “FIFO” Mode.
NOTE: These bits are only active if the Receive Slip Buffer has been
configured to operate in the FIFO Mode.
44
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 23: DMA 0 (WRITE) CONFIGURATION REGISTER (D0WCR)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0Xn118
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
DMA0 RST
R/W
0
DMA_0 Reset
This bit resets the transmit DMA (Write) channel 0.
0 = Normal operation.
1 = A zero to one transition resets the transmit DMA (Write) channel 0.
6
DMA0 ENB
R/W
0
DMA_0 Enable
This bit enables the transmit DMA_0 (Write) interface. After a transmit
DMA is enabled, DMA transfers are only requested when the transmit
buffer status bits indicate that there is space for a complete message
or cell.
The DMA write channel is used by the external DMA controller to
transfer data from the external memory to the HDLC buffers within the
E1 Framer. The DMA Write cycle starts by E1 Framer asserting the
DMA Request (REQ0) ‘low’, then the external DMA controller should
drive the DMA Acknowledge (ACK0) ‘low’ to indicate that it is ready to
start the transfer. The external DMA controller should place new data
on the Microprocessor data bus each time the Write Signal is Strobed
low if the WR is configured as a Write Strobe. If WR is configured as a
direction signal, then the external DMA controller would place new
data on the Microprocessor data bus each time the Read Signal (RD)
is Strobed low.
0 = Disables the transmit DMA_0 (Write) interface
1 = Enables the transmit DMA_0 (Write) interface
5
WR TYPE
R/W
0
Write Type Select
This bit selects the function of the WR signal.
0 = WR functions as a direction signal (indicates whether the current
bus cycle is a read or write operation) and RD functions as a data
strobe signal.
1 =WR functions as a write strobe signal
-
-
Reserved
Channel Select
These three bits select which T/E1 channel within the XRT86VL38
uses the Transmit DMA_0 (Write) interface.
000 = Channel 0
001 = Channel 1
001 = Channel 2
011 = Channel 3
100 = Channel 4
101 = Channel 5
110 = Channel 6
111 = Channel 7
4 - 3 Reserved
2
DMA0_CHAN(2)
R/W
0
1
DMA0_CHAN(1)
R/W
0
0
DMA0_CHAN(0)
R/W
0
45
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 24: DMA 1 (READ) CONFIGURATION REGISTER (D1RCR)
BIT
FUNCTION
7-6 Reserved
TYPE
DEFAULT
-
-
Reserved
HEX ADDRESS: 0Xn119
DESCRIPTION-OPERATION
7
DMA1 RST
R/W
0
DMA_1 Reset
This bit resets the Receive DMA (Read) Channel 1
0 = Normal operation.
1 = A zero to one transition resets the Receive DMA (Read) channel 1.
6
DMA1 ENB
R/W
0
DMA1_ENB
This bit enables the Receive DMA_1 (Read) interface. After a receive
DMA is enabled, DMA transfers are only requested when the receive
cell buffer contains a complete message or cell.
The DMA read channel is used by the E1 Framer to transfer data from
the HDLC buffers within the E1 Framer to external memory. The DMA
Read cycle starts by E1 Framer asserting the DMA Request (REQ1)
‘low’, then the external DMA controller should drive the DMA Acknowledge (ACK1) ‘low’ to indicate that it is ready to receive the data. The
E1 Framer should place new data on the Microprocessor data bus
each time the Read Signal is Strobed low if the RD is configured as a
Read Strobe. If RD is configured as a direction signal, then the E1
Framer would place new data on the Microprocessor data bus each
time the Write Signal (WR) is Strobed low.
0 = Disables the DMA_1 (Read) interface
1 = Enables the DMA_1 (Read) interface
5
RD TYPE
R/W
0
READ Type Select
This bit selects the function of the RD signal.
0 = RD functions as a Read Strobe signal
1 = RD acts as a direction signal (indicates whether the current bus
cycle is a read or write operation), and WR works as a data strobe.
-
-
Reserved
Channel Select
These three bits select which T/E1 channel within the chip uses the
Receive DMA_1 (Read) interface.
000 = Channel 0
001 = Channel 1
001 = Channel 2
011 = Channel 3
100 = Channel 4
101 = Channel 5
110 = Channel 6
111 = Channel 7
4 - 3 Reserved
2
DMA1_CHAN(2)
R/W
0
1
DMA1_CHAN(1)
R/W
0
0
DMA1_CHAN(0)
R/W
0
46
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 25: INTERRUPT CONTROL REGISTER (ICR)
BIT
FUNCTION
7-3 Reserved
REV. V1.2.1
HEX ADDRESS: 0Xn11A
TYPE
DEFAULT
DESCRIPTION-OPERATION
-
-
Reserved
2
INT_WC_RUR
R/W
0
Interrupt Write-to-Clear or Reset-upon-Read Select
This bit configures all Interrupt Status bits to be either Reset Upon
Read or Write-to-Clear
0 = Configures all Interrupt Status bits to be Reset Upon Read
(RUR).
1= Configures all Interrupt Status bits to be Write-to-Clear (WC).
1
ENBCLR
R/W
0
Interrupt Enable Auto Clear
This bit configures all interrupt enable bits to clear or not clear after
reading the interrupt status bit.
0= Configures all Interrupt Enable bits to not cleared after reading
the interrupt status bit. The corresponding Interrupt Enable bit will
stay ‘high’ after reading the interrupt status bit.
1= Configures all interrupt Enable bits to clear after reading the
interrupt status bit. The corresponding interrupt enable bit will be set
to ‘low’ after reading the interrupt status bit.
0
INTRUP_ENB
R/W
0
Interrupt Enable for Framer_n
This bit enables the entire E1 Framer Block for Interrupt Generation.
0 = Disables the E1 framer block for Interrupt Generation
1 = Enables the E1 framer block for Interrupt Generation
47
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 26: LAPD SELECT REGISTER (LAPDSR)
BIT
FUNCTION
[7:2] Reserved
[1:0] HDLC Controller
Select[1:0]
HEX ADDRESS: 0Xn11B
TYPE
DEFAULT
DESCRIPTION-OPERATION
-
-
Reserved
R/W
0
HDLC Controller Select[1:0]:
These bits permit the user to select any of the three (3) HDLC Controllers that he/she will use within this particular channel, as
depicted below.
00 & 11 - Selects HDLC Controller # 1
01 - Selects HDLC Controller # 2
10 - Selects HDLC Controller # 3
TABLE 27: PERFORMANCE REPORT CONTROL REGISTER (PRCR)
BIT
FUNCTION
7
Reserved
6
RLOS_OUT_ENB
5-0 Reserved
HEX ADDRESS: 0Xn11D
TYPE
DEFAULT
DESCRIPTION-OPERATION
-
-
For T1 mode only
R/W
1
RLOS Output Enable:
This bit is used to enable or disable the Receive LOS (RLOS_n) output pins.
0 - Disables the RLOS output pin.
1 - Enables the RLOS output pin.
-
-
Reserved.
48
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 28: GAPPED CLOCK CONTROL REGISTER (GCCR)
BIT
7
FUNCTION
FrOutclk
6-0 Reserved
REV. V1.2.1
HEX ADDRESS: 0Xn11E
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Framer Output Clock Reference
This bit is used to enable or disable high-speed T1/E1 rate on the
T1OSCCLK and the E1OSCCLK output pins.
By default, the output clock reference on T1OSCCLK and
E1OSCCLK output pins is 1.544MHz/2.048MHz respectively. By setting this bit to a “1”, the output clock reference on the T1OSCLK and
the E1OSCCLK is 49.408MHz/65.536MHz for T1/E1 respectively.
0 = Disables high-speed rate to be output on the T1OSCCLK and
E1OSCCLK output pins. Standard T1/E1 Rate - 1.544MHz/2.048Mhz
will be output to the T1OSCCLK and E1OSCCLK output pins respectively.
1 = Enables high-speed rate to be output on the T1OSCCLK and
E1OSCCLK output pins.
-
-
Reserved
49
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 29: TRANSMIT INTERFACE CONTROL REGISTER (TICR)
BIT
7
FUNCTION
TxSyncFrD
HEX ADDRESS:0Xn120
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Transmit Synchronous fraction data interface
This bit selects whether TxCHCLK or TxSERCLK will be used for fractional data input if the transmit fractional interface is enabled. If TxSERCLK is selected to clock in fractional data input, TxCHCLK will be used
as an enable signal
0 = Fractional data Is clocked into the chip using TxChCLK if the transmit fractional data interface is enabled.
1 = Fractional data is clocked into the chip using TxSerClk if the transmit fractional data interface is enabled. TxChClk is used as fractional
data enable.
NOTE: The Time Slot Identifier Pins (TxChn[4:0]) still indicates the time
slot number if the transmit fractional data interface is not
enabled. Fractional Interface can be enabled by setting
TxFr2048 to 1
6
Reserved
-
-
Reserved
5
TxPLClkEnb
R/W
0
Transmit payload clock enable
This bit configures the E1 framer to output a regular clock or a payload
clock on the transmit serial clock (TxSERCLK) pin when TxSERCLK is
configured to be an output.
0 = Configures the framer to output a 2.048MHz clock on the TxSERCLK pin when TxSERCLK is configured as an output.
1 = Configures the framer to output a 2.048MHz clock on the TxSERCLK pin when transmitting payload bits. There will be gaps on the
TxSERCLK output pin when transmitting overhead bits.
4
TxFr2048
R/W
0
Transmit Fractional/Signaling Interface Enabled
This bit is used to enable or disable the transmit fractional data interface, signaling input, as well as the 32MHz transmit clock and the transmit overhead Signal output. This bit only functions when the device is
configured in non-high speed or multiplexed modes of operations.
If the device is configured in base rate:
0 = Configures the 5 time slot identifier pins (TxChn[4:0]) to output the
channel number as usual.
1 = Configures the 5 time slot identifier pins (TxChn[4:0]) into the following different functions:
TxChn[0] becomes the Transmit Serial SIgnaling pin (TxSIG_n) for signaling inputs. Signaling data can now be input from the TxSIG pin if
configured appropriately.
TxChn[1] becomes the Transmit Fractional Data Input pin (TxFrTD_n)
for fractional data input. Fractional data can now be input from the
TxFrTD pin if configured appropriately.
TxChn[2] becomes the 32 MHz transmit clock output
TxChn[3] becomes the Transmit Overhead Signal which pulses high on
the first bit of each multi-frame.
NOTE: This bit has no function in the high speed or multiplexed modes
of operation. In high-speed or multiplexed modes, TxCHN[0]
functions as TxSIGn for signaling input.
50
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 29: TRANSMIT INTERFACE CONTROL REGISTER (TICR)
BIT
3
FUNCTION
TxICLKINV
REV. V1.2.1
HEX ADDRESS:0Xn120
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Transmit Clock Inversion (Backplane Interface)
This bit selects whether data transition will happen on the rising or falling edge of the transmit clock.
0 = Selects data transition happen on the rising edge of the transmit
clocks.
1 = Selects data transition happen on the falling edge of the transmit
clocks.
NOTE: This feature is only available for base rate configuration (i.e.
non-highspeed, or non-multiplexed modes).
2
TxMUXEN
R/W
0
Transmit Multiplexed Mode Enable
This bit enables or disables the multiplexed mode on the transmit side.
When multiplexed mode is enable, four-channel data from the backplane interface are multiplexed onto one serial stream and output to the
line side. The backplane speed will be running at 16.384MHz once multiplexed mode is enabled.
0 = Disables the multiplexed mode.
1 = Enables the multiplexed mode.
51
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 29: TRANSMIT INTERFACE CONTROL REGISTER (TICR)
BIT
FUNCTION
HEX ADDRESS:0Xn120
TYPE
DEFAULT
DESCRIPTION-OPERATION
Transmit Interface Mode selection
This bit determines the transmit interface speed. The exact function of
these two bits depends on whether Multiplexed mode is enabled or disabled. Table 30 and Table 31shows the functions of these bits for nonmultiplexed and multiplexed modes.:
1
TxIMODE[1]
R/W
0
0
TxIMODE[0]
R/W
0
TABLE 30: TRANSMIT INTERFACE SPEED WHEN MULTIPLEXED MODE
IS DISABLED (TXMUXEN = 0)
TXIMODE[1:0]
TRANSMIT INTERFACE SPEED
00
2.048Mbit/s. (Base Rate)
Transmit Backplane interface signals include:
TxSERCLK is an input or output clock at
2.048MHz
TxMSYNC is the superframe boundary at 2ms
TxSYNC is the single frame boundary at 125 us
TxSER is the base-rate data input
01
2.048Mbit/ (High-speed MVIP Mode)
Transmit Backplane interface signals include:
TxSERCLK is an input clock at 2.048MHz
TxMSYNC will become the high speed input clock
at 2.048MHz to input high-speed data
TxSYNC indicates the single frame boundary
TxSER is the high-speed data input
10
4.096Mbit/s High-speed mode:
Transmit Backplane interface signals include:
TxSERCLK is an input clock at 2.048MHz
TxMSYNC will become the high speed input clock
at 4.096MHz to input high-speed data
TxSYNC indicates the single frame boundary
TxSER is the high-speed data input
11
8.192Mbit/s High-speed mode:
Transmit Backplane interface signals include:
TxSERCLK is an input clock at 2.048MHz
TxMSYNC will become the high speed input clock
at 8.192MHz to input high-speed data
TxSYNC indicates the single frame boundary
TxSER is the high-speed data input
52
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 29: TRANSMIT INTERFACE CONTROL REGISTER (TICR)
BIT
FUNCTION
1-0 TxIMODE[1:0]
TYPE
DEFAULT
R/W
0
REV. V1.2.1
HEX ADDRESS:0Xn120
DESCRIPTION-OPERATION
(Continued):
TABLE 31: TRANSMIT INTERFACE SPEED WHEN MULTIPLEXED MODE
IS ENABLED (TXMUXEN = 1)
TXIMODE[1:0]
TRANSMIT INTERFACE SPEED
00
Reserved
01
16.384MHz Bit Multiplexed Mode:
The transmit interface is taking four-channel multiplexed data at a rate of 16.384Mbit/s from channel
0 and bit-demultiplexing the serial data into 4 channels and output to the line on channels 0 through 3.
The TxSYNC signal pulses “High” during the first bit
of each E1 frame.
10
HMVIP High-Speed Multiplexed Mode Enabled:
Transmit interface is taking four-channel multiplexed data at a rate of 16.384Mbit/s from channel
0 and byte-demultiplexing the serial data into 4
channels and output to the line on channels 0
through 3. The TxSYNC signal pulses “High” during
the last two bits of the previous E1 frame and the
first two bits of the current E1 frame.
11
H.100 High-Speed Multiplexed Mode Enabled:
Transmit interface is taking four-channel multiplexed data at a rate of 16.384Mbit/s from channel
0 and byte-demultiplexing the serial data into 4
channels and output to the line on channels 0
through 3. The TxSYNC signal pulses “High” during
the last bit of the previous E1 frame and the first bit
of the current E1 frame.
Transmit Backplane interface signals include:
TxSERCLK is an input clock at 2.048MHz
TxMSYNC will become the high speed input clock at 16.384MHz to
input high-speed multiplexed data on the back-plane interface
TxSYNC is the single multiplexed frame boundary
TxSER is the high-speed data input
NOTE: In high speed mode, transmit data is sampled on the rising edge
of the 16MHz clock edge. Multiplexed data on Channel 4 is demultiplexed into the LIU outputs at channel 4 through 7.
53
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 32: PRBS CONTROL AND STATUS REGISTER 0 (PRBSCSR0)
BIT
FUNCTION
HEX ADDRESS: 0XN121
TYPE
DEFAULT
DESCRIPTION-OPERATION
3
PRBS_Switch
R/W
0
PRBS Switch
This bit enables or disables the PRBS switch function within the
XRT86VL38 device.
By enabling the PRBS switch function, PRBS functionality will be
switched between the receive and transmit framer. E1 Receive
framer will generate the PRBS pattern and insert it onto the receive
backplane interface, and E1 Transmit Framer will be monitoring the
transmit backplane interface for PRBS pattern and declare PRBS
LOCK if PRBS has locked onto the input pattern.
If PRBS switch is disabled, E1 Transmit framer will generate the
PRBS pattern to the line interface and the receive framer will be
monitoring the line for PRBS/QRTS pattern and declare PRBS
LOCK if PRBS has locked onto the input pattern.
0 = Disables the PRBS Switch Feature.
1 = Enables the PRBS Switch Feature.
2
BER[1]
R/W
0
1
BER[0]
R/W
0
Bit Error Rate
This bit is used to insert PRBS bit error at the rates presented at the
table below. The exact function of this bit depends on whether
PRBS switch function is enabled or not. (bit 3 within this register).
If the PRBS switch function is disabled, bit error will be inserted by
the E1 transmit framer out to the line interface if this bit is enabled.
If the PRBS switch function is enabled, bit error will be inserted by
the E1 receive framer out to the receive backplane interface if this
bit is enabled.
BER[1:0]
BIT ERROR RATE
00
Disable Bit Error insertion to the transmit output
or receive backplane interface
01
Bit Error is inserted to the transmit output or
receive backplane interface at a rate of 1/1000
(one out of one Thousand)
10
Bit Error is inserted to the transmit output or
receive backplane interface at a rate of 1/
1,000,000 (one out of one million)
11
Disable Bit Error insertion to the transmit output
or receive backplane interface
54
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 32: PRBS CONTROL AND STATUS REGISTER 0 (PRBSCSR0)
BIT
0
REV. V1.2.1
HEX ADDRESS: 0XN121
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
UnFramedPRBS
R/W
0
Unframed PRBS Pattern
This bit enables or disables unframed PRBS/QRTS pattern generation (i.e. All timeslots and framing bits are all PRBS/QRTS data).
The exact function of this bit depends on whether PRBS switch
function is enabled or not. (bit 3 within this register).
If PRBS switch function is disabled, E1 Transmit Framer will generate an unframed PRBS 15 or QRTS pattern to the line side if this bit
is enabled.
If PRBS switch function is enabled, E1 Receive Framer will generate an unframed PRBS 15 or QRTS pattern to the receive backplane interface if this bit is enabled.
0 - Enables an unframed PRBS/QRTS pattern generation to the line
interface or to the receive backplane interface
1 - Disables an unframed PRBS/QRTS pattern generation to the line
interface or to the receive backplane interface
55
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 33: RECEIVE INTERFACE CONTROL REGISTER (RICR)
BIT
7
HEX ADDRESS: 0XN122
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
RxSyncFrD
R/W
0
Receive Synchronous fraction data interface
This bit selects whether RxCHCLK or RxSERCLK will be used for fractional
data output if receive fractional interface is enabled. If RxSERCLK is selected
to clock out fractional data, RxCHCLK will be used as an enable signal
0 = Fractional data Is clocked out of the chip using RxChCLK if the receive
fractional interface is enabled.
1 = Fractional data is clocked out of the chip using RxSerClk if the receive
fractional interface is enabled. RxChClk is used as fractional data enable.
NOTE: The Time Slot Identifier Pins (RxChn[4:0]) still indicates the time slot
number if the receive fractional data interface is not enabled.
Fractional Interface can be enabled by setting RxFr2048 to 1
6
Reserved
-
-
Reserved
5
RxPLClkEnb
R/W
0
Receive payload clock enable
This bit configures the E1 framer to either output a regular clock or a payload
clock on the receive serial clock (RxSERCLK) pin when RxSERCLK is configured to be an output.
0 = Configures the framer to output a 2.048MHz clock on the RxSERCLK pin
when RxSERCLK is configured as an output.
1 = Configures the framer to output a 2.048MHz clock on the RxSERCLK pin
when receiving payload bits. There will be gaps on the RxSERCLK output pin
when receiving overhead bits.
4
RxFr2048
R/W
0
Receive Fractional/Signaling Interface Enabled
This bit is used to enable or disable the receive fractional output interface,
receive signaling output, the serial channel number output, as well as the
8kHz and the received recovered clock output. This bit only functions when
the device is configured in non-high speed or multiplexed modes of operations.
If the device is configured in base rate:
0 = configure the 5 time slot identifier pins (RxChn[4:0]) to output the channel
number in parallel as usual.
1 = configure the 5 time slot identifier pins (RxChn[4:0]) into the following different functions:
RxChn[0] becomes the Receive Serial SIgnaling output pin (RxSIG_n) for signaling outputs. Signaling data can now be output to the RxSIG pin if configured appropriately.
RxChn[1] becomes the Receive Fractional Data Output pin (RxFrTD_n) for
fractional data output. Fractional data can now be output to the RxFrTD pin if
configured appropriately.
RxChn[2] outputs the serial channel number
RxChn[3] outputs an 8kHz clock signal.
RxCHN[4] outputs the received recovered clock signal (2.048MHz for E1)
NOTE: This bit has no function in the high speed or multiplexed modes of
operation. In high-speed or multiplexed modes, RxCHN[0] outputs the
Signaling data and RxCHN[4] outputs the recovered clock.
56
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 33: RECEIVE INTERFACE CONTROL REGISTER (RICR)
BIT
3
REV. V1.2.1
HEX ADDRESS: 0XN122
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
RxICLKINV
N/A
0
Receive Clock Inversion (Backplane Interface)
This bit selects whether data transition will happen on the rising or falling edge
of the receive clock.
0 = Selects data transition happen on the rising edge of the receive clocks.
1 = Selects data transition happen on the falling edge of the receive clocks.
NOTE: This feature is only available for base rate configuration (i.e. nonhighspeed, or non-multiplexed modes).
2
RxMUXEN
R/W
0
Receive Multiplexed Mode Enable
This bit enables or disables the multiplexed mode on the receive side. When
multiplexed mode is enable, four channels data from the line side are multiplexed onto one serial stream and output to the back-plane interface on
RxSER. The backplane speed will become 16.384MHz once multiplexed
mode is enabled.
0 = Disables the multiplexed mode.
1 = Enables the multiplexed mode.
57
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 33: RECEIVE INTERFACE CONTROL REGISTER (RICR)
BIT
HEX ADDRESS: 0XN122
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
1
RxIMODE[1]
R/W
0
0
RxIMODE[0]
R/W
0
Receive Interface Mode Selection
This bit determines the receive interface speed. The exact function of these
two bits depends on whether Receive Multiplexed mode is enabled or disabled. Table 34 and Table 35 shows the functions of these two bits for nonmultiplexed and multiplexed modes.:
TABLE 34: RECEIVE INTERFACE SPEED WHEN MULTIPLEXED MODE IS
DISABLED (TXMUXEN = 0)
RXIMODE[1:0]
RECEIVE INTERFACE SPEED
00
2.048Mbit/s. (Base Rate Mode)
Receive backplane interface signals include:
RxSERCLK is an input or output clock at 2.048MHz
RxSYNC is an input or output signal which indicates the
receive singe frame boundary
RxSER is the base-rate data output
01
2.048Mbit/s (High-speed MVIP Mode)
Receive Backplane Interface signals include:
RxSERCLK is an input clock at 2.048MHz
RxSYNC is an input signal which indicates the receive
singe frame boundary
RxSER is the high-speed data output
10
4.096Mbit/s High-speed Mode:
Receive Backplane Interface signals include:
RxSERCLK is an input clock at 4.096MHz
RxSYNC is an input signal which indicates the receive
singe frame boundary
RxSER is the high-speed data output
11
8.192Mbit/s High-speed Mode:
Receive Backplane Interface signals include:
RxSERCLK is an input clock at 8.192MHz
RxSYNC is an input signal which indicates the receive
singe frame boundary
RxSER is the high-speed data output
58
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 33: RECEIVE INTERFACE CONTROL REGISTER (RICR)
BIT
FUNCTION
1-0 RxIMODE
TYPE
DEFAULT
R/W
0
REV. V1.2.1
HEX ADDRESS: 0XN122
DESCRIPTION-OPERATION
(Continued):
TABLE 35: RECEIVE INTERFACE SPEED WHEN MULTIPLEXED MODE IS
ENABLED (TXMUXEN = 1)
TXIMODE[1:0]
TRANSMIT INTERFACE SPEED
00
Reserved
01
16.384MHz Bit-Multiplexed Mode
Receive interface is taking data from the four LIU input
channels 0 through 3 and byte-multiplexing the fourchannel data into one 16.384MHz serial stream and output to channel 0 of the Receive Serial Output (RxSER).
The RxSYNC signal pulses “High” during the framing bit
of each E1 frame.
10
HMVIP High-Speed Multiplexed Mode:
Receive interface is taking data from the four LIU input
channels 0 through 3 and byte-multiplexing the fourchannel data into one 16.384MHz serial stream and output to channel 0 of the Receive Serial Output (RxSER).
The RxSYNC signal pulses “High” during the last two
bits of the previous E1 frame and the first two bits of the
current E1 frame.
11
H.100 High-Speed Multiplexed Mode:
Receive interface is taking data from the four LIU input
channels 0 through 3 and byte-multiplexing the fourchannel data into one 16.384MHz serial stream and output to channel 0 of the Receive Serial Output (RxSER).
The RxSYNC signal pulses “High” during the last bit of
the previous E1 frame and the first bit of the current E1
frame.
Receive Backplane Interface signals include:
RxSERCLK is an input clock at 16.384MHz
RxSYNC is an input signal which indicates the multiplexed frame boundary.
The length of RxSYNC depends on the multiplexed mode selected.
RxSER is the high-speed data output
NOTE: In high speed mode, receive data is clocked out on the rising edge of
the 16MHz clock edge.
NOTE: Channels 4 through 7 are multiplexed into the receive serial output
(RxSER) at channel 4 in the same fashion.
59
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 36: PRBS CONTROL AND STATUS REGISTER 1 (PRBSCSR1)
BIT
7
FUNCTION
PRBSTyp
HEX ADDRESS: 0XN123
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
PRBS Pattern Type
This bit selects the type of PRBS pattern that the E1 Transmit/
Receive framer will generate or detect. PRBS 15 (X15 + X14 +1)
Polynomial or QRTS (Quasi-Random Test Signal) Pattern can be
generated by the transmit or receive framer depending on whether
PRBS switch function is enabled or not (bit 3 in register 0xn121).
If the PRBS Switch function is disabled, E1 transmit framer will generate either PRBS 15 or QRTS pattern and output to the line interface. PRBS 15 or QRTS pattern depends on the setting of this bit.
If the PRBS Switch function is enabled, E1 receive framer will generate either PRBS 15 or QRTS pattern and output to the receive
back plane interface. PRBS 15 or QRTS pattern depends on the
setting of this bit.
0 = Enables the PRBS 15 (X15 + X14 +1) Polynomial generation.
1 = Enables the QRTS (Quasi-Random Test Signal) pattern generation.
6
ERRORIns
R/W
0
Error Insertion
This bit is used to insert a single PRBS/QRTS error to the transmit
or receive output depending on whether PRBS switch function is
enabled or not. (bit 3 in register 0xn121).
If the PRBS Switch function is disabled, E1 transmit framer will
insert a single PRBS/QRTS error and output to the line interface if
this bit is enabled.
If the PRBS Switch function is enabled, E1 receive framer will insert
a single PRBS/QRTS error and output to the receive back plane
interface if this bit is enabled.
A ‘0’ to ‘1’ transition will cause one output bit inverted in the PRBS/
QRTS stream.
This bit only works if PRBS generation
5
DATAInv
R/W
0
PRBS Data Invert:
This bit inverts the Transmit PRBS/QRTS output data and the
Receive PRBS/QRTS input data. The exact function of this bit
depends on whether PRBS switch function is enabled or not. (bit 3
in register 0xn121).
If the PRBS Switch function is disabled and if this bit is enabled, E1
transmit framer will invert the PRBS/QRTS data before it outputs to
the line interface, and the E1 receive framer will invert the incoming
PRBS/QRTS data before it receives it.
If the PRBS Switch function and this bit are both enabled, E1
receive framer will invert the PRBS/QRTS data before it outputs to
the line interface, and the E1 transmit framer will invert the incoming
PRBS/QRTS data before it receives it.
0 - Transmit and Receive Framer will not invert the Transmit PRBS/
QRTS and Receive PRBS data.
1 - Transmit and Receive Framer will invert the Transmit PRBS/
QRTS and Receive PRBS data.
60
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 36: PRBS CONTROL AND STATUS REGISTER 1 (PRBSCSR1)
BIT
FUNCTION
TYPE
DEFAULT
REV. V1.2.1
HEX ADDRESS: 0XN123
DESCRIPTION-OPERATION
4
RxPRBSLock
RO
0
Lock Status
This READ ONLY bit field indicates whether or not the Receive or
Transmit PRBS lock has obtained. The exact function of this bit
depends on whether PRBS switch function is enabled or not. (bit 3
in register 0xn121).
If the PRBS Switch function is disabled, E1 receive framer will
declare LOCK if PRBS/QRTS has locked onto the input pattern.
If the PRBS Switch function is disabled, E1 transmit framer will
declare LOCK if PRBS/QRTS has locked onto the input pattern.
0 = Indicates the Receive PRBS/QRTS has not Locked onto the
input patterns.
1 = Indicates the Receive PRBS/QRTS has locked onto the input
patterns.
3
RxPRBSEnb
R/W
0
Receive PRBS Detection/Generation Enable
This bit enables or disables the receive PRBS/QRTS pattern detection or generation. The exact function of this bit depends on whether
PRBS switch function is enabled or not. (bit 3 in register 0xn121).
If the PRBS switch function is disabled and if this bit is enabled, E1
Receive Framer will detect the incoming PRBS/QRTS pattern from
the line side and declare PRBS/QRTS lock if incoming data locks
onto the PRBS/QRTS pattern.
If the PRBS switch function and this bit are both enabled, E1 Transmit Framer will detect the incoming PRBS/QRTS pattern from the
transmit backplane interface and declare PRBS/QRTS lock if incoming data locks onto the PRBS/QRTS pattern.
0 = Disables the Receive PRBS/QRTS pattern detection.
1 - Enables the Receive PRBS/QRTS pattern detection.
2
TxPRBSEnb
R/W
0
Transmit PRBS Generation Enable
This bit enables or disables the Transmit PRBS pattern generator.
The exact function of this bit depends on whether PRBS switch
function is enabled or not. (bit 3 in register 0xn121).
If PRBS switch function is disabled, E1 Transmit Framer will generate the PRBS 15 or QRTS pattern to the line side if this bit is
enabled.
If PRBS switch function is enabled, E1 Receive Framer will generate the PRBS 15 or QRTS pattern to the receive backplane interface
if this bit is enabled.
0 = Disables the Transmit PRBS/QRTS pattern generator.
1 - Enables the Transmit PRBS/QRTS pattern generator.
1
RxBypass
R/W
0
Receive Framer Bypass
This bit enables or disables the Receive E1 Framer bypass.
0 = Disables the Receive E1 framer Bypass.
1 - Enables the Receive E1 Framer Bypass
0
TxBypass
R/W
0
Transmit Framer Bypass
This bit enables or disables the Transmit E1 Framer bypass.
0 = Disables the Transmit E1 framer Bypass.
1 - Enables the Transmit E1 Framer Bypass
61
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 37: LOOPBACK CODE CONTROL REGISTER (LCCR)
BIT
FUNCTION
7-0 Reserved
TYPE
DEFAULT
-
-
HEX ADDRESS: 0XN124
DESCRIPTION-OPERATION
For T1 mode only
TABLE 38: TRANSMIT LOOPBACK CODER REGISTER (TLCR)
BIT
FUNCTION
7-0 Reserved
TYPE
DEFAULT
-
-
HEX ADDRESS: 0XN125
DESCRIPTION-OPERATION
For T1 mode only
TABLE 39: RECEIVE LOOPBACK ACTIVATION CODE REGISTER (RLACR)
BIT
FUNCTION
TYPE
DEFAULT
7-0 Reserved
DESCRIPTION-OPERATION
For T1 mode only
TABLE 40: RECEIVE LOOPBACK DEACTIVATION CODE REGISTER (RLDCR)
BIT
FUNCTION
TYPE
DEFAULT
7-0 Reserved
7
FUNCTION
DEFDET
HEX ADDRESS: 0XN127
DESCRIPTION-OPERATION
For T1 mode only
TABLE 41: DEFECT DETECTION ENABLE REGISTER (DDER)
BIT
HEX ADDRESS: 0XN126
HEX ADDRESS: 0XN129
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
1
For defect detection per ANSI T1.231-1997 and T1.403-1999, user
should leave this bit set to ‘1’.
62
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 42: TRANSMIT Sa SELECT REGISTER (TSASR)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0XN130
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
TxSa8SEL
R/W
0
Transmit Sa8 bit select
This bit determines whether National Bit (Sa8) is inserted from the
transmit serial input (TxSER_n) pin or from the Transmit Sa8 register (Register address = 0xn137).
0 = Selects Sa 8 to be inserted from the Transmit Serial input
(TxSER_n) input pin.
1 = Selects Sa 8 to be inserted from the Transmit Sa8 Register
(Register address = 0xn137)
6
TxSa7SEL
R/W
0
Transmit Sa7 bit select
This bit determines whether National Bit (Sa7) is inserted from the
transmit serial input (TxSER_n) pin or from the Transmit Sa7 register (Register address = 0xn136).
0 = Selects Sa 7 to be inserted from the Transmit Serial input
(TxSER_n) input pin.
1 = Selects Sa 7 to be inserted from the Transmit Sa7 Register
(Register address = 0xn136)
5
TxSa6SEL
R/W
0
Transmit Sa6 bit select
This bit determines whether National Bit (Sa6) is inserted from the
transmit serial input (TxSER_n) pin or from the Transmit Sa6 register (Register address = 0xn135).
0 = Selects Sa 6 to be inserted from the Transmit Serial input
(TxSER_n) input pin.
1 = Selects Sa 6 to be inserted from the Transmit Sa6 Register
(Register address = 0xn135)
4
TxSa5SEL
R/W
0
Transmit Sa5bit select
This bit determines whether National Bit (Sa5) is inserted from the
transmit serial input (TxSER_n) pin or from the Transmit Sa5 register (Register address = 0xn134).
0 = Selects Sa 5 to be inserted from the Transmit Serial input
(TxSER_n) input pin.
1 = Selects Sa 5 to be inserted from the Transmit Sa5 Register
(Register address = 0xn134)
3
TxSa4SEL
R/W
0
Transmit Sa4 bit select
This bit determines whether National Bit (Sa4) is inserted from the
transmit serial input (TxSER_n) pin or from the Transmit Sa4 register (Register address = 0xn133).
0 = Selects Sa 4 to be inserted from the Transmit Serial input
(TxSER_n) input pin.
1 = Selects Sa 4 to be inserted from the Transmit Sa4 Register
(Register address = 0xn133)
63
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 42: TRANSMIT Sa SELECT REGISTER (TSASR)
BIT
2
FUNCTION
LB1ENB
HEX ADDRESS: 0XN130
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Local Loopback 1 auto enable
This bit enables or disables local loopback mode when the National
bits (Sa5, Sa6) and the A bit (remote alarm bit) received from the
transmit backplane interface follows a specific pattern.
Local loopback is activated when the National Bits (Sa5, Sa 6) and
A bit (remote alarm bit) follow the following pattern from the transmit
serial input. (TxSER_n pin)
Sa5 = 00000000 occur for 8 consecutive times
Sa6 = 11111111 occur for 8 consecutive times
A = 11111111 occur for 8 consecutive times
NOTE: This feature only works if Sa bits are provided from the
transmit serial input pin (TxSER_n)
1
LB2ENB
R/W
0
Local Loopback 2 auto enable
This bit enables or disables local loopback mode when the National
bits (Sa5, Sa6) received from the transmit backplane interface follows a specific pattern.
Local loopback is activated when the National Bits (Sa5, Sa 6) and
A bit (remote alarm bit) follow the following pattern from the transmit
serial input. (TxSER_n pin)
Sa5 = 00000000 occur for 8 consecutive times, and
Sa6 = 10101010 occur for 8 consecutive times, and
A = 11111111 occur for 8 consecutive times
NOTE: This feature only works if Sa bits are provided from the
transmit serial input pin (TxSER_n)
0
LBRENB
R/W
0
Local Loopback release enable
This bit releases the local loopback mode when the National bits
(Sa5, Sa6) received from the transmit backplane interface follows a
specific pattern.
Local loopback is released when the National Bits (Sa5, Sa 6) follow
the following pattern from the transmit serial input. (TxSER_n pin)
Sa5 = 00000000 occur for 8 consecutive times
Sa6 = 00000000 occur for 8 consecutive times
NOTE: This feature only works if Sa bits are provided from the
transmit serial input pin (TxSER_n)
64
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 43: TRANSMIT Sa AUTO CONTROL REGISTER 1 (TSACR1)
BIT
7
REV. V1.2.1
HEX ADDRESS: 0XN131
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
LOSLFA_1_ENB
R/W
0
LOS/LFA 1 automatic transmission
This bit enables the automatic Sa-bit transmission upon detecting
Loss of Signal (LOS) or Loss of frame alignment (LFA) condition.
Upon detecting Loss of Signal or Loss of Frame alignment condition, E1 framer will transmit the Sa5 bit as ‘1’, and Sa6 bit as ‘0’ pattern.
See Table 44 for the transmit Sa5, Sa6, and A bit pattern upon
detecting LOS or LFA conditions.
6
LOS_1_ENB
R/W
0
LOS 1 automatic transmission
This bit enables the auto Sa-bit transmission upon detecting Loss of
Signal (LOS) condition.
Upon detecting Loss of Signal condition, E1 framer will transmit the
Alarm bit (A bit) as ‘1’, Sa5 bit as ‘1’, and Sa6 bit as ‘1110’ pattern.
See Table 44 for the transmit Sa5, Sa6, and A bit pattern upon
detecting LOS condition.
5
LOSLFA_2_ENB
R/W
0
LOS/LFA 2 automatic transmission
This bit enables the auto Sa-bit transmission upon detecting Loss of
Signal (LOS) or Loss of frame alignment (LFA) condition.
Upon detecting Loss of Signal or Loss of Frame alignment condition, E1 framer will transmit the Alarm bit (A bit) as ‘1’, Sa5 bit as ‘0’,
and Sa6 bit as ‘0’ pattern.
See Table 44 for the transmit Sa5, Sa6, and A bit pattern upon
detecting LOS or LFA conditions.
4
LOSLFA_3_ENB
R/W
0
LOS/LFA 3 automatic transmission
This bit enables the auto Sa-bit transmission upon detecting Loss of
Signal (LOS) or Loss of frame alignment (LFA) condition.
Upon detecting Loss of Signal or Loss of Frame alignment condition, E1 framer will transmit the Alarm bit (A bit) as ‘0’, Sa5 bit as ‘1’,
and Sa6 bit as ‘1100’ pattern.
See Table 44 for the transmit Sa5, Sa6, and A bit pattern upon
detecting LOS/LFA conditions.
3
LOSLFA_4_ENB
R/W
0
LOS/LFA 4 automatic transmission
This bit enables the auto Sa-bit transmission upon detecting Loss of
Signal (LOS) or Loss of frame alignment (LFA) condition.
Upon detecting Loss of Signal or Loss of Frame alignment condition, E1 framer will transmit the Alarm bit (A bit) as ‘0’, Sa5 bit as ‘1’,
and Sa6 bit as ‘1110’ pattern.
See Table 44 for the transmit Sa5, Sa6, and A bit pattern upon
detecting LOS/LFA conditions.
65
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 43: TRANSMIT Sa AUTO CONTROL REGISTER 1 (TSACR1)
BIT
2
FUNCTION
NOP_ENB
HEX ADDRESS: 0XN131
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
No power automatic transmission
This bit enables the auto Sa-bit transmission upon detecting Loss of
Power condition. The XRT86VL38 device recognizes the Loss of
Power condition by monitoring the Loss of Power input pin (pin
AB1). When the Loss of Power input pin is HIGH indicates a Loss of
Power condition is occurring. When the Loss of Power input pin is
LOW indicates no Loss of Power condition detected.
Upon detecting Loss of Power condition, E1 framer will transmit the
Alarm bit (A bit) as ‘0’, Sa5 bit as ‘1’, and Sa6 bit as ‘1000’ pattern.
See Table 44 for the transmit Sa5, Sa6, and A bit pattern upon
detecting Loss of Power condition.
1
NOP_LOSLFA_ENB
R/W
0
No power and LOS/LFA automatic transmission
This bit enables the auto Sa-bit transmission upon detecting the following two conditions:
1. Upon Loss of Power and Loss of Signal (LOS) or
2. Upon Loss of Power and Loss of frame alignment (LFA)
When the E1 framer detects any one of the above two conditions,
E1 framer will transmit the Alarm bit (A bit) as ‘1’, Sa5 bit as ‘1’, Sa6
bit as ‘1000’ pattern.
See Table 44 for the transmit Sa5, Sa6, and A bit format upon
detecting loss of power and LOS/LFA conditions.
0
LOS_2_ENB
R/W
0
LOS 3 automatic transmission
This bit enables the auto Sa-bit transmission upon detecting Loss of
Signal (LOS) condition.
Upon detecting Loss of Signal condition, E1 framer will transmit the
Sa5 and Sa6 bit as an Auxiliary (10101010...) pattern
See Table 44 for the transmit Sa5, Sa6, and A bit format upon
detecting LOS condition.
The following table demonstrates the conditions on the receive side which trigger the Automatic Sa, and A bit
transmission when TSACR1 bits are enabled.
TABLE 44: CONDITIONS ON RECEIVE SIDE WHEN TSACR1 BITS ARE ENABLED
CONDITIONS
ACTIONS - SENDING PATTERN
COMMENTS
A
SA5
SA6
LOSLFA_1_ENB: Loss of signal or Loss of
frame alignment
X
1
0000
LOS/LFA at TE (FC2)
LOS_1_ENB: Loss of signal
1
1
1110
LOS (FC3)
LOSLFA_2_ENB: LOS or LFA
1
0
0000
LOS/LFA (FCL)
LOSLFA_3_ENB: LOS or LFA
0
1
1100
LOS/LFA (FC4)
LOSLFA_4_ENB: LOS or LFA
0
1
1110
LOS/LFA (FC3&FC4)
NOP_ENB: Loss of power
0
1
1000
Loss of power at NT1
NOP_LOSLFA_ENB: Loss of power and LOS
or LFA
1
1
1000
Loss of power and LOS/LFA
LOS_2_ENB: LOS
AUXP pattern
66
LOS (FC1). Transmit AUXP pattern
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 45: TRANSMIT Sa AUTO CONTROL REGISTER 2 (TSACR2)
BIT
7
FUNCTION
AIS_1_ENB
REV. V1.2.1
HEX ADDRESS: 0XN132
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
AIS reception
This bit enables the automatic Sa-bit transmission upon detecting
AIS condition.
Upon detecting the AIS condition, E1 framer will transmit the Alarm
bit (A bit) as ‘1’, Sa5 bit as ‘1’, and Sa6 bit as ‘1’.
See Table 46 for the transmit Sa5, Sa6, and A bit pattern upon
detecting AIS condition.
6
AIS_2_ENB
R/W
0
AIS reception
This bit enables the automatic Sa-bit transmission upon detecting
AIS condition.
Upon detecting the AIS condition, E1 framer will transmit the Alarm
bit (A bit) as ‘0’, Sa5 bit as ‘1’, and Sa6 bit as ‘1’.
See Table 46 for the transmit Sa5, Sa6, and A bit pattern upon
detecting AIS condition.
5
Reserved
-
-
Reserved
4
Reserved
-
-
Reserved
3
CRCREP_ENB[1]
R/W
0
2
CRCREP_ENB[0]
R/W
0
CRC report
These two bits enable the automatic Sa-bit transmission upon
detecting Far End Block Error (i.e. received E bit = 0).
Upon detecting the Far End Block Error (FEBE) condition, E1 framer
will transmit the Alarm bit (A bit) as ‘0’, Sa5 bit as ‘1’, Sa6 bit as
‘0000’, and E bit as ‘0’ pattern if these two bits are set to ‘01’.
If these two bits are set to ‘10’, E1 framer will transmit the Alarm bit
(A bit) as ‘0’, Sa5 bit as ‘0’, Sa6 bit as ‘0000’, and E bit as ‘0’ pattern
upon detecting the Far End Block Error (FEBE).
If these two bits are set to ‘11’, E1 framer will transmit the Alarm bit
(A bit) as ‘0’, Sa5 bit as ‘1’, Sa6 bit as ‘0001’, and E bit as ‘1’ pattern
upon detecting the Far End Block Error (FEBE).
See Table 46 for the transmit Sa5, Sa6, E, and A bit pattern upon
detecting FEBE condition.
1
CRCDET_ENB
R/W
0
CRC detection
This bit enables the automatic Sa-bit transmission upon detecting
CRC-4 error condition.
Upon detecting CRC-4 error condition, E1 framer will transmit the
Alarm bit (A bit) as ‘0’, Sa5 bit as ‘1’, Sa6 bit as ‘0010’, and E bit as
‘1’ pattern.
See Table 46 for the transmit Sa5, Sa6, E, and A bit pattern upon
detecting CRC-4 error condition.
0
CRCREC AND
DET_ENB
R/W
0
CRC report and detect
This bit enables automatic Sa-bit transmission upon detecting both
Far End Block Error (FEBE) and CRC-4 error conditions.
Upon detecting both Far End Block Error (FEBE) and CRC-4 error
condition, E1 framer will transmit the Alarm bit (A bit) as ‘0’, Sa5 bit
as ‘1’, Sa6 bit as ‘0011’, and E bit as ‘1’ pattern.
See Table 46 for the transmit Sa5, Sa6, E, and A bit pattern upon
detecting both FEBE and CRC-4 error conditions.
67
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
The following table demonstrates the conditions on receive side which trigger the Automatic Sa, E, and A bits
transmission when TSACR2 bits are enabled.
TABLE 46: CONDITIONS ON RECEIVE SIDE WHEN TSACR2 BITS ENABLED
ACTIONS - SENDING PATTERN FOR
CONDITIONS
A
SA5
SA6
E
AIS_1_ENB
1
1
1111
X
AIS_2_ENB
0
1
1111
x
CRCREP_ENB = 01, CRC reported (E = 0)
0
1
0000
0
CRCREP_ENB = 10, CRC reported
0
0
0000
0
CRCREP_ENB = 11, CRC reported
0
1
0001
1
CRCDET_ENB
0
1
0010
1
CRCDET/REP_ENB
0
1
0011
1
68
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 47: TRANSMIT Sa4 REGISTER (TSA4R)
BIT
FUNCTION
7-0 TxSa4[7:0]
HEX ADDRESS: 0XN133
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
11111111 Transmit Sa4 Sequence
The content of this register sources the transmit Sa4 bits if data link
selects Sa 4 bit for transmission and if Sa4 is inserted from register.
(i.e. TxSa4ENB bit in register 0xn10A = 1 and TxSa4SEL bit in register 0xn130 = 1).
Bit 7 of this register is transmitted in the Sa4 position in frame 2 of
the CRC-4 multiframe, and bit 6 of this register is transmitted in the
Sa4 position in frame 4 of the CRC-4 multiframe,...etc.
TABLE 48: TRANSMIT Sa5 REGISTER (TSA5R)
BIT
FUNCTION
7-0 TxSa5[7:0]
HEX ADDRESS: 0XN134
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
11111111 Transmit Sa5 Sequence
The content of this register sources the transmit Sa5 bits if data link
selects Sa 5 bit for transmission and if Sa5 is inserted from register.
(i.e. TxSa5ENB bit in register 0xn10A = 1 and TxSa5SEL bit in register 0xn130 = 1).
Bit 7 of this register is transmitted in the Sa5 position in frame 2 of
the CRC-4 multiframe, and bit 6 of this register is transmitted in the
Sa5 position in frame 4 of the CRC-4 multiframe,...etc.
TABLE 49: TRANSMIT Sa6 REGISTER (TSA6R)
BIT
FUNCTION
7-0 TxSa6[7:0]
HEX ADDRESS: 0XN135
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
11111111 Transmit Sa6 Sequence
The content of this register sources the transmit Sa6 bits if data link
selects Sa 6 bit for transmission and if Sa6 is inserted from register.
(i.e. TxSa6ENB bit in register 0xn10A = 1 and TxSa6SEL bit in register 0xn130 = 1).
Bit 7 of this register is transmitted in the Sa6 position in frame 2 of
the CRC-4 multiframe, and bit 6 of this register is transmitted in the
Sa6 position in frame 4 of the CRC-4 multiframe,...etc.
TABLE 50: TRANSMIT Sa7 REGISTER (TSA7R)
BIT
FUNCTION
7-0 TxSa7[7:0]
REV. V1.2.1
HEX ADDRESS: 0XN136
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
11111111 Transmit Sa7 Sequence
The content of this register sources the transmit Sa7 bits if data link
selects Sa 7 bit for transmission and if Sa7 is inserted from register.
(i.e. TxSa7ENB bit in register 0xn10A = 1 and TxSa7SEL bit in register 0xn130 = 1).
Bit 7 of this register is transmitted in the Sa7 position in frame 2 of
the CRC-4 multiframe, and bit 6 of this register is transmitted in the
Sa7 position in frame 4 of the CRC-4 multiframe,...etc.
69
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 51: TRANSMIT Sa8 REGISTER (TSA8R)
BIT
FUNCTION
7-0 TxSa8[7:0]
HEX ADDRESS: 0XN137
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
11111111 Transmit Sa8 Sequence
The content of this register sources the transmit Sa8 bits when data
link selects Sa 8 bit for transmission and if Sa8 is inserted from register.
(i.e. TxSa8ENB bit in register 0xn10A = 1 and TxSa8SEL bit in register 0xn130 = 1).
Bit 7 of this register is transmitted in the Sa8 position in frame 2 of
the CRC-4 multiframe, and bit 6 of this register is transmitted in the
Sa8 position in frame 4 of the CRC-4 multiframe,...etc.
70
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 52: RECEIVE SA4 REGISTER (RSA4R)
BIT
FUNCTION
7-0 RxSa4[7:0]
TYPE
RO
HEX ADDRESS: 0XN13B
DEFAULT
DESCRIPTION-OPERATION
00000000 Received Sa4 Sequence
The content of this register stores the Sa 4 bits in the most recently
received CRC-4 multiframe. This register is updated when the entire
multiframe is received.
This register will show the contents of the received Sa4 bits if data
link selects Sa4 bit for reception. (i.e.RxSa4ENB bit in register
0xn10Ch = 1).
Bit 7 of this register indicates the received Sa4 bit in frame 2 of the
CRC-4 multiframe, and bit 6 of this register indicates the received
Sa4 bit in frame 4 of the CRC-4 multiframe,...etc.
TABLE 53: RECEIVE SA5 REGISTER (RSA5R)
BIT
FUNCTION
7-0 RxSa5[7:0]
TYPE
RO
HEX ADDRESS: 0XN13C
DEFAULT
DESCRIPTION-OPERATION
00000000 Received Sa5 Sequence
The content of this register stores the Sa 5 bits in the most recently
received CRC-4 multiframe. This register is updated when the entire
multiframe is received.
This register will show the contents of the received Sa5 bits if data
link selects Sa5 bit for reception. (i.e.RxSa5ENB bit in register
0xn10Ch = 1).
Bit 7 of this register indicates the received Sa5 bit in frame 2 of the
CRC-4 multiframe, and bit 6 of this register indicates the received
Sa5 bit in frame 4 of the CRC-4 multiframe,...etc.
TABLE 54: RECEIVE SA6 REGISTER (RSA6R)
BIT
FUNCTION
7-0 RxSa6[7:0]
TYPE
RO
REV. V1.2.1
HEX ADDRESS: 0Xn13D
DEFAULT
DESCRIPTION-OPERATION
00000000 Received Sa6 Sequence
The content of this register stores the Sa 6 bits in the most recently
received CRC-4 multiframe. This register is updated when the entire
multiframe is received.
This register will show the contents of the received Sa6 bits if data
link selects Sa6 bit for reception. (i.e.RxSa6ENB bit in register
0xn10Ch = 1).
Bit 7 of this register indicates the received Sa6 bit in frame 2 of the
CRC-4 multiframe, and bit 6 of this register indicates the received
Sa6 bit in frame 4 of the CRC-4 multiframe,...etc.
71
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 55: RECEIVE SA7 REGISTER (RSA7R)
BIT
FUNCTION
7-0 RxSa7[7:0]
TYPE
RO
HEX ADDRESS: 0Xn13E
DEFAULT
DESCRIPTION-OPERATION
00000000 Received Sa7 Sequence
The content of this register stores the Sa 7 bits in the most recently
received CRC-4 multiframe. This register is updated when the entire
multiframe is received.
This register will show the contents of the received Sa7 bits if data
link selects Sa7 bit for reception. (i.e.RxSa7ENB bit in register
0xn10Ch = 1).
Bit 7 of this register indicates the received Sa7 bit in frame 2 of the
CRC-4 multiframe, and bit 6 of this register indicates the received
Sa7 bit in frame 4 of the CRC-4 multiframe,...etc.
TABLE 56: RECEIVE SA8 REGISTER (RSA8R)
BIT
FUNCTION
7-0 RxSa8[7:0]
TYPE
RO
HEX ADDRESS: 0Xn13F
DEFAULT
DESCRIPTION-OPERATION
00000000 Received Sa8 Sequence
The content of this register stores the Sa 8 bits in the most recently
received CRC-4 multiframe. This register is updated when the entire
multiframe is received.
This register will show the contents of the received Sa8 bits if data
link selects Sa8 bit for reception. (i.e.RxSa8ENB bit in register
0xn10Ch = 1).
Bit 7 of this register indicates the received Sa8 bit in frame 2 of the
CRC-4 multiframe, and bit 6 of this register indicates the received
Sa8 bit in frame 4 of the CRC-4 multiframe,...etc.
72
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 57: DATA LINK CONTROL REGISTER (DLCR2)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0Xn143
TYPE
DEFAULT
DESCRIPTION-OPERATION
-
-
Reserved. Please set this bit to’0’ for normal operation.
7
Reserved
6
MOS ABORT Disable
R/W
0
MOS ABORT Disable:
This bit permits the user to either enable or disable the “Automatic
MOS ABORT” feature within Transmit HDLC Controller # 2. If the
user enables this feature, then Transmit HDLC Controller block # 2
will automatically transmit the ABORT Sequence (e.g., a zero followed by a string of 7 consecutive “1s”) whenever it abruptly transitions from transmitting a MOS type of message, to transmitting a
BOS type of message.
If the user disables this feature, then the Transmit HDLC Controller
Block # 2 will NOT transmit the ABORT sequence, whenever it
abruptly transitions from transmitting a MOS-type of message to
transmitting a BOS-type of message.
0 - Enables the “Automatic MOS Abort” feature
1 - Disables the “Automatic MOS Abort” feature
5
Rx_FCS_DIS
R/W
0
Receive Frame Check Sequence (FCS) Verification Enable/Disable
This bit permits the user to configure the Receive HDLC Controller
Block # 2 to compute and verify the FCS value within each incoming
LAPD message frame.
0 - Enables FCS Verification
1 - Disables FCS Verification
4
AutoRx
R/W
0
Auto Receive LAPD Message
This bit configures the Receive HDLC Controller Block #2 to discard
any incoming BOS or LAPD Message frame that exactly match
which is currently stored in the Receive HDLC2 buffer.
0 = Disables this “AUTO DISCARD” feature
1 = Enables this “AUTO DISCARD” feature.
3
Tx_ABORT
R/W
0
Transmit ABORT
This bit configures the Transmit HDLC Controller Block #2 to transmit an ABORT sequence (string of 7 or more consecutive 1’s) to the
Remote terminal.
0 - Configures the Transmit HDLC Controller Block # 2 to function
normally (e.g., not transmit the ABORT sequence).
1 - Configures the Transmit HDLC Controller block # 2 to transmit
the ABORT Sequence.
73
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 57: DATA LINK CONTROL REGISTER (DLCR2)
BIT
2
FUNCTION
Tx_IDLE
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Transmit Idle (Flag Sequence Byte)
This bit configures the Transmit HDLC Controller Block #2 to unconditionally transmit a repeating string of Flag Sequence octets (0X7E)
in the data link channel to the Remote terminal. In normal conditions, the Transmit HDLC Controller block will repeatedly transmit
the Flag Sequence octet whenever there is no MOS message to
transmit to the remote terminal equipment. However, if the user
invokes this “Transmit Idle Sequence” feature, then the Transmit
HDLC Controller block will UNCONDITIONALLY transmit a repeating stream of the Flag Sequence octet (thereby overwriting all outbound MOS data-link messages).
0 - Configures the Transmit HDLC Controller Block # 2 to transmit
data-link information in a “normal” manner.
1 - Configures the Transmit HDLC Controller block # 2 to transmit a
repeating string of Flag Sequence Octets (0x7E).
NOTE:
1
Tx_FCS_EN
HEX ADDRESS: 0Xn143
R/W
0
This bit is ignored if the Transmit HDLC2 controller is
operating in the BOS Mode - bit 0 (MOS/BOS) within this
register is set to 0.
Transmit LAPD Message with Frame Check Sequence (FCS)
This bit permits the user to configure the Transmit HDLC Controller
block # 2 to compute and append FCS octets to the “back-end” of
each outbound MOS data-link message.
0 - Configures the Transmit HDLC Controller block # 2 to NOT compute and append the FCS octets to the back-end of each outbound
MOS data-link message.
1 - Configures the Transmit HDLC Controller block # 2 TO COMPUTE and append the FCS octets to the back-end of each outbound
MOS data-link message.
NOTE: This bit is ignored if the transmit HDLC2 controller has been
configured to operate in the BOS mode - bit 0 (MOS/BOS)
within this register is set to 0.
0
MOS/BOS
R/W
0
Message Oriented Signaling/Bit Oriented Signaling Send
This bit permits the user to enable LAPD transmission through
HDLC Controller Block # 2 using either BOS (Bit-Oriented Signaling)
or MOS (Message-Oriented Signaling) frames.
0 - Transmit HDLC Controller block # 2 BOS message Send.
1 - Transmit HDLC Controller block # 2 MOS message Send.
NOTE: This is not an Enable bit. This bit must be set to "0" each time
a BOS is to be sent.
74
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 58: TRANSMIT DATA LINK BYTE COUNT REGISTER (TDLBCR2)
BIT
7
FUNCTION
TxHDLC2 BUFAvail/
BUFSel
REV. V1.2.1
HEX ADDRESS: 0Xn144
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Transmit HDLC2 Buffer Available/Buffer Select
This bit has different functions, depending upon whether the user is
writing to or reading from this register, as depicted below.
If the user is writing data into this register bit:
0 - Configures the Transmit HDLC2 Controller to read out and transmit the data, residing within “Transmit HDLC2 Buffer # 0", via the
Data Link channel to the remote terminal equipment.
1 - Configures the Transmit HDLC2 Controller to read out and transmit the data, residing within the “Transmit HDLC2 Buffer #1”, via the
Data Link channel to the remote terminal equipment.
If the user is reading data from this register bit:
0 - Indicates that “Transmit HDLC2 Buffer # 0" is the next available
buffer. In this case, if the user wishes to write in the contents of a
new “outbound” Data Link Message into the Transmit HDLC2 Message Buffer, he/she should proceed to write this message into
“Transmit HDLC2 Buffer # 0" - Address location: 0xn600.
1 - Indicates that “Transmit HDLC2 Buffer # 1" is the next available
buffer. In this case, if the user wishes to write in the contents of a
new “outbound” Data Link Message into the Transmit HDLC2 Message Buffer, he/she should proceed to write this message into
“Transmit HDLC2 Buffer # 1" - Address location: 0xn700.
NOTE: If one of these Transmit HDLC2 buffers contain a message
which has yet to be completely read-in and processed for
transmission by the Transmit HDLC2 controller, then this bit
will automatically reflect the value corresponding to the next
available buffer when it is read. Changing this bit to the inuse buffer is not permitted.
6-0 TDLBC[6:0]
R/W
0000000 Transmit HDLC2 Message - Byte Count
The exact function of these bits depends on whether the Transmit
HDLC 2 Controller is configured to transmit MOS or BOS messages
to the Remote Terminal Equipment.
In BOS MODE:
These bit fields contain the number of repetitions the BOS message
must be transmitted before the Transmit HDLC2 controller generates the Transmit End of Transfer (TxEOT) interrupt and halts transmission. If these fields are set to 00000000, then the BOS message
will be transmitted for an indefinite number of times.
In MOS MODE:
These bit fields contain the length, in number of octets, of the message to be transmitted. The length of MOS message specified in
these bits include header bytes such as the SAPI, TEI, Control field,
however, it does not include the FCS bytes.
75
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 59: RECEIVE DATA LINK BYTE COUNT REGISTER (RDLBCR2)
BIT
7
FUNCTION
RBUFPTR
6-0 RDLBC[6:0]
HEX ADDRESS: 0Xn145
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Receive HDLC2 Buffer-Pointer
This bit Identifies which Receive HDLC2 buffer contains the most
recently received HDLC2 message.
0 - Indicates that Receive HDLC2 Buffer # 0 contains the contents of
the most recently received HDLC message.
1 - Indicates that Receive HDLC2 Buffer # 1 contains the contents of
the most recently received HDLC message.
R/W
0000000 Receive HDLC Message - byte count
The exact function of these bits depends on whether the Receive
HDLC Controller Block #2 is configured to receive MOS or BOS
messages.
In BOS Mode:
These seven bits contain the number of repetitions the BOS message must be received before the Receive HDLC2 controller generates the Receive End of Transfer (RxEOT) interrupt. If these bits are
set to “0000000”, the message will be received indefinitely and no
Receive End of Transfer (RxEOT) interrupt will be generated.
In MOS Mode:
These seven bits contain the size in bytes of the HDLC2 message
that has been received and written into the Receive HDLC buffer.
The length of MOS message shown in these bits include header
bytes such as the SAPI, TEI, Control field, AND the FCS bytes.
76
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 60: DATA LINK CONTROL REGISTER (DLCR3)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0Xn153
TYPE
DEFAULT
DESCRIPTION-OPERATION
-
-
Reserved. Please set this bit to’0’ for normal operation.
7
Reserved
6
MOS ABORT
Disable
R/W
0
MOS ABORT Disable:
This bit permits the user to either enable or disable the “Automatic MOS
ABORT” feature within Transmit HDLC Controller # 3. If the user enables this
feature, then Transmit HDLC Controller block # 3 will automatically transmit
the ABORT Sequence (e.g., a zero followed by a string of 7 consecutive
“1s”) whenever it abruptly transitions from transmitting a MOS type of message, to transmitting a BOS type of message.
If the user disables this feature, then the Transmit HDLC Controller Block # 3
will NOT transmit the ABORT sequence, whenever it abruptly transitions
from transmitting a MOS-type of message to transmitting a BOS-type of
message.
0 - Enables the “Automatic MOS Abort” feature
1 - Disables the “Automatic MOS Abort” feature
5
Rx_FCS_DIS
R/W
0
Receive Frame Check Sequence (FCS) Verification Enable/Disable
This bit permits the user to configure the Receive HDLC Controller Block # 3
to compute and verify the FCS value within each incoming LAPD message
frame.
0 - Enables FCS Verification
1 - Disables FCS Verification
4
AutoRx
R/W
0
Auto Receive LAPD Message
This bit configures the Receive HDLC Controller Block #3 to discard any
incoming BOS or LAPD Message frame that exactly match which is currently
stored in the Receive HDLC1 buffer.
0 = Disables this “AUTO DISCARD” feature
1 = Enables this “AUTO DISCARD” feature.
3
Tx_ABORT
R/W
0
Transmit ABORT
This bit configures the Transmit HDLC Controller Block #3 to transmit an
ABORT sequence (string of 7 or more consecutive 1’s) to the Remote terminal.
0 - Configures the Transmit HDLC Controller Block # 3 to function normally
(e.g., not transmit the ABORT sequence).
1 - Configures the Transmit HDLC Controller block # 3 to transmit the
ABORT Sequence.
77
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 60: DATA LINK CONTROL REGISTER (DLCR3)
BIT
2
FUNCTION
Tx_IDLE
HEX ADDRESS: 0Xn153
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Transmit Idle (Flag Sequence Byte)
This bit configures the Transmit HDLC Controller Block #3 to unconditionally
transmit a repeating string of Flag Sequence octets (0X7E) in the data link
channel to the Remote terminal. In normal conditions, the Transmit HDLC
Controller block will repeatedly transmit the Flag Sequence octet whenever
there is no MOS message to transmit to the remote terminal equipment.
However, if the user invokes this “Transmit Idle Sequence” feature, then the
Transmit HDLC Controller block will UNCONDITIONALLY transmit a repeating stream of the Flag Sequence octet (thereby overwriting all outbound
MOS data-link messages).
0 - Configures the Transmit HDLC Controller Block # 3 to transmit data-link
information in a “normal” manner.
1 - Configures the Transmit HDLC Controller block # 3 to transmit a repeating string of Flag Sequence Octets (0x7E).
NOTE: This bit is ignored if the Transmit HDLC3 controller is operating in the
BOS Mode - bit 0 (MOS/BOS) within this register is set to 0.
1
Tx_FCS_EN
R/W
0
Transmit LAPD Message with Frame Check Sequence (FCS)
This bit permits the user to configure the Transmit HDLC Controller block # 3
to compute and append FCS octets to the “back-end” of each outbound
MOS data-link message.
0 - Configures the Transmit HDLC Controller block # 3 to NOT compute and
append the FCS octets to the back-end of each outbound MOS data-link
message.
1 - Configures the Transmit HDLC Controller block # 3 TO COMPUTE and
append the FCS octets to the back-end of each outbound MOS data-link
message.
NOTE:
0
MOS/BOS
R/W
0
This bit is ignored if the transmit HDLC3 controller has been
configured to operate in the BOS mode - bit 0 (MOS/BOS) within this
register is set to 0.
Message Oriented Signaling/Bit Oriented Signaling Send
This bit permits the user to enable LAPD transmission through HDLC Controller Block # 3 using either BOS (Bit-Oriented Signaling) or MOS (Message-Oriented Signaling) frames.
0 - Transmit HDLC Controller block # 3 BOS message Send.
1 - Transmit HDLC Controller block # 3 MOS message Send.
NOTE: This is not an Enable bit. This bit must be set to "0" each time a BOS
is to be sent.
78
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 61: TRANSMIT DATA LINK BYTE COUNT REGISTER (TDLBCR3)
BIT
7
FUNCTION
TxHDLC3 BUFAvail/
BUFSel
REV. V1.2.1
HEX ADDRESS: 0Xn154
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Transmit HDLC3 Buffer Available/Buffer Select
This bit has different functions, depending upon whether the user is
writing to or reading from this register, as depicted below.
If the user is writing data into this register bit:
0 - Configures the Transmit HDLC3 Controller to read out and transmit the data, residing within “Transmit HDLC3 Buffer # 0", via the
Data Link channel to the remote terminal equipment.
1 - Configures the Transmit HDLC3 Controller to read out and transmit the data, residing within the “Transmit HDLC3 Buffer #1”, via the
Data Link channel to the remote terminal equipment.
If the user is reading data from this register bit:
0 - Indicates that “Transmit HDLC3 Buffer # 0" is the next available
buffer. In this case, if the user wishes to write in the contents of a
new “outbound” Data Link Message into the Transmit HDLC3 Message Buffer, he/she should proceed to write this message into
“Transmit HDLC3 Buffer # 0" - Address location: 0xn600.
1 - Indicates that “Transmit HDLC3 Buffer # 1" is the next available
buffer. In this case, if the user wishes to write in the contents of a
new “outbound” Data Link Message into the Transmit HDLC3 Message Buffer, he/she should proceed to write this message into
“Transmit HDLC3 Buffer # 1" - Address location: 0xn700.
NOTE: If one of these Transmit HDLC3 buffers contain a message
which has yet to be completely read-in and processed for
transmission by the Transmit HDLC3 controller, then this bit
will automatically reflect the value corresponding to the next
available buffer when it is read. Changing this bit to the inuse buffer is not permitted.
6-0 TDLBC[6:0]
R/W
0000000 Transmit HDLC3 Message - Byte Count
The exact function of these bits depends on whether the Transmit
HDLC 3 Controller is configured to transmit MOS or BOS messages
to the Remote Terminal Equipment.
In BOS MODE:
These bit fields contain the number of repetitions the BOS message
must be transmitted before the Transmit HDLC3 controller generates the Transmit End of Transfer (TxEOT) interrupt and halts transmission. If these fields are set to 00000000, then the BOS message
will be transmitted for an indefinite number of times.
In MOS MODE:
These bit fields contain the length, in number of octets, of the message to be transmitted. The length of MOS message specified in
these bits include header bytes such as the SAPI, TEI, Control field,
however, it does not include the FCS bytes.
79
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 62: RECEIVE DATA LINK BYTE COUNT REGISTER (RDLBCR3)
BIT
7
FUNCTION
RBUFPTR
6-0 RDLBC[6:0]
HEX ADDRESS: 0Xn155
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Receive HDLC3 Buffer-Pointer
This bit Identifies which Receive HDLC3 buffer contains the most
recently received HDLC1 message.
0 - Indicates that Receive HDLC3 Buffer # 0 contains the contents of
the most recently received HDLC message.
1 - Indicates that Receive HDLC3 Buffer # 1 contains the contents of
the most recently received HDLC message.
R/W
0000000 Receive HDLC Message - byte count
The exact function of these bits depends on whether the Receive
HDLC Controller Block #3 is configured to receive MOS or BOS
messages.
In BOS Mode:
These seven bits contain the number of repetitions the BOS message must be received before the Receive HDLC3 controller generates the Receive End of Transfer (RxEOT) interrupt. If these bits are
set to “0000000”, the message will be received indefinitely and no
Receive End of Transfer (RxEOT) interrupt will be generated.
In MOS Mode:
These seven bits contain the size in bytes of the HDLC3 message
that has been received and written into the Receive HDLC buffer.
The length of MOS message shown in these bits include header
bytes such as the SAPI, TEI, Control field, AND the FCS bytes.
80
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 63: DEVICE ID REGISTER (DEVID)
BIT
FUNCTION
HEX ADDRESS: 0XN1FE
TYPE
DEFAULT
RO
0x3B
DEVID[7:0]
7-0
DESCRIPTION-OPERATION
DEVID
This register is used to identify the XRT86VL38 Framer/LIU. The
value of this register is 0x3Bh.
TABLE 64: REVISION ID REGISTER (REVID)
BIT
FUNCTION
7-0 REVID[7:0]
TYPE
RO
REV. V1.2.1
HEX ADDRESS: 0XN1FF
DEFAULT
DESCRIPTION-OPERATION
00000010 REVID
This register is used to identify the revision number of the XRT86VL38.
The value of this register for the current revision is B - 0x02h.
NOTE: The content of this register is subject to change when a newer
revision of the device is issued.
81
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 65: TRANSMIT CHANNEL CONTROL REGISTER 0-31 (TCCR 0-31)
BIT
FUNCTION
7
LAPDcntl[1]
6
LAPDcntl[0]
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
1
Transmit LAPD Control
These bits select which one of the three Transmit LAPD controller is configured to use D/E time slot (Octets 0-31) for transmitting LAPD messages.
The following table presents the different settings of these two bits.
0
LAPDCNTL[1:0]
NOTE:
5-4 Reserved
HEX ADDRESS: 0Xn300 TO 0Xn31F
-
-
LAPD CONTROLLER SELECTED
00
Transmit LAPD Controller 1
01
Transmit LAPD Controller 2
10
The TxDE[1:0] bits in the Transmit Signaling and
Data Link Select Register (TSDLSR - Register
Address - 0xn10A, bit 3-2) determine the data
source for D/E time slots.
11
Transmit LAPD Controller 3
All three Transmit LAPD Controllers can use D/E timeslots for
transmission. However, only Transmit LAPD Controller 1 can use
datalink for transmission. Register 0xn300 represents D/E time slot
0, and 0xn31F represents D/E time slot 31.
Reserved (For T1 mode only)
82
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 65: TRANSMIT CHANNEL CONTROL REGISTER 0-31 (TCCR 0-31)
BIT
FUNCTION
3-0 TxCond(3:0)
REV. V1.2.1
HEX ADDRESS: 0Xn300 TO 0Xn31F
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0000
Transmit Channel Conditioning for Timeslot 0 to 31
These bits allow the user to substitute the input PCM data (Octets 0-31) with
internally generated Conditioning Codes prior to transmission to the remote
terminal equipment on a per-channel basis. The table below presents the
different conditioning codes based on the setting of these bits.
NOTE:
Register address 0xn300 represents time slot 0, and address
0xn31F represents time slot 31.
TXCOND[1:0]
0x0 / 0xE
CONDITIONING CODES
Contents of timeslot octet are unchanged.
0x1
All 8 bits of the selected timeslot octet are inverted (1’s
complement)
OUTPUT = (TIME_SLOT_OCTET) XOR 0xFF
0x2
Even bits of the selected timeslot octet are inverted
OUTPUT = (TIME_SLOT_OCTET) XOR 0xAA
0x3
Odd bits of the selected time slot octet are inverted
OUTPUT = (TIME_SLOT_OCTET) XOR 0x55
0x4
Contents of the selected timeslot octet will be substituted
with the 8 -bit value in the Transmit
Programmable User Code Register (0xn320-0xn337),
0x5
Contents of the timeslot octet will be substituted with the
value 0x7F (BUSY Code)
0x6
Contents of the timeslot octet will be substituted with the
value 0xFF (VACANT Code)
0x7
Contents of the timeslot octet will be substituted with the
BUSY time slot code (111#_####), where ##### is the
Timeslot number
0x8
Contents of the timeslot octet will be substituted with the
MOOF code (0x1A)
0x9
Contents of the timeslot octet will be substituted with the
A-Law Digital Milliwatt pattern
0xA
Contents of the timeslot octet will be substituted with the
µ-Law Digital Milliwatt pattern
0xB
The MSB (bit 1) of input data is inverted
0xC
All input data except MSB is inverted
0xD
Contents of the timeslot octet will be substituted with the
PRBS X15 + X 14 + 1/QRTS pattern
NOTE: PRBS X15 + X 14 + 1 or QRTS pattern depends on
PRBSType selected in the register 0xn123 - bit 7
0xF
D/E time slot - The TxSIGDL[2:0] bits in the Transmit Signaling and Data Link Select Register (0xn10A) will determine the data source for D/E time slots.
83
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 66: TRANSMIT USER CODE REGISTER 0 - 31 (TUCR 0-31)
BIT
7-0
FUNCTION
TUCR[7:0]
TYPE
R/W
DEFAULT
HEX ADDRESS: 0Xn320 TO 0Xn33F
DESCRIPTION-OPERATION
b00010111 Transmit Programmable User code.
These eight bits allow users to program any code in this register to
replace the input PCM data when the Transmit Channel Control
Register (TCCR) is configured to replace timeslot octet with programmable user code. (i.e. if TCCR is set to ‘0x4’)
The default value of this register is an IDLE Code (b00010111).
84
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 67: TRANSMIT SIGNALING CONTROL REGISTER 0-31 (TSCR 0-31)
BIT
7
FUNCTION
A (x)
REV. V1.2.1
HEX ADDRESS: 0Xn340 TO 0XN35F
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
See Note Transmit Signaling bit A or x bit
This bit allows users to provide signaling Bit A for octets 0-31 if
Channel Associated Signaling (CAS) is enabled and if signaling
data is inserted from TSCR register (TxSIGSRC[1:0] = 01 in this
register)
NOTE: Users must write to TSCR0 (Address 0xn340) the correct
CAS alignment bits (0 bits) in order to get CAS SYNC at the
remote terminal. The xyxx bits can be programmed by
writing to TSCR16 (0xn350) and programming the
TxSIGSRC[1:0] bits within this register to ‘b11’.
6
B (y)
R/W
See Note Transmit Signaling bit B or y bit
This bit allows users to provide signaling Bit B for octets 0-31 if
Channel Associated Signaling (CAS) is enabled and if signaling
data is inserted from TSCR register (TxSIGSRC[1:0] = 01 in this
register)
NOTE: Users must write to TSCR0 (Address 0xn340) the correct
CAS alignment bits (0 bits) in order to get CAS SYNC at the
remote terminal. The xyxx bits can be programmed by
writing to TSCR16 (0xn350) and programming the
TxSIGSRC[1:0] bits within this register to ‘b11’.
5
C (x)
R/W
See Note Transmit Signaling bit C or x bit
This bit allows users to provide signaling Bit C for octets 0-31 if
Channel Associated Signaling (CAS) is enabled and if signaling
data is inserted from TSCR register (TxSIGSRC[1:0] = 01 in this
register)
NOTE: Users must write to TSCR0 (Address 0xn340) the correct
CAS alignment bits (0 bits) in order to get CAS SYNC at the
remote terminal. The xyxx bits can be programmed by
writing to TSCR16 (0xn350) and programming the
TxSIGSRC[1:0] bits within this register to ‘b11’.
4
D (x)
R/W
See Note Transmit Signaling bit D or x bit
This bit allows users to provide signaling Bit D in for octets 0-31 if
Channel Associated Signaling (CAS) is enabled and if signaling
data is inserted from TSCR register (TxSIGSRC[1:0] = 01 in this
register)
NOTE: Users must write to TSCR0 (Address 0xn340) the correct
CAS alignment bits (0 bits) in order to get CAS SYNC at the
remote terminal. The xyxx bits can be programmed by
writing to TSCR16 (0xn350) and programming the
TxSIGSRC[1:0] bits within this register to ‘b11’.
3
Reserved
-
See Note Reserved
2
Reserved
-
See Note Reserved
85
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 67: TRANSMIT SIGNALING CONTROL REGISTER 0-31 (TSCR 0-31)
BIT
FUNCTION
HEX ADDRESS: 0Xn340 TO 0XN35F
TYPE
DEFAULT
See Note Channel signaling control
These bits determine the source for signaling information. The table
See Note
below presents the different sources for signaling information corresponding to different settings of these two bits.
1
TxSIGSRC[1]
R/W
0
TxSIGSRC[0]
R/W
DESCRIPTION-OPERATION
TXSIGSRC[1:0]
SIGNALING SOURCE SELECTED
00
Signaling data is inserted from input PCM
data (TxSERn pin)
01
Signaling data is inserted from this register
(TSCRs).
10
Signaling data is inserted from the transmit
Overhead input pin (TxOH_n) if XRT86VL38
is configured in the base rate configuration
and if the Transmit Signaling Interface bit is
disabled. (i.e. TxMUXEN bit = 0, TxIMODE[1:0] = 00, and TxFr2048 bit = 0 in the
Transmit Interface Control Register (TICR)
Register 0xn120).
If the Transmit Signaling Interface bit is
enabled (i.e. TxFr2048 bit = 1 in the Transmit Interface Control Register (TICR) Register 0xn120), signaling data will be inserted
from the Transmit Signaling input pin
(TxSIG_n)
11
No signaling data is inserted into the input
PCM data. Setting these two bits to ‘11’ will
configure the xyxx bits only, where x bits are
inserted from this register (TSCR) and y bit
reflects the alarm condition.
NOTE: The default value for register address 0xn340 = 0x01, 0xn341-0xn34F = 0xD0, 0xn350 = 0xB3, 0xn351-0xn35F =
0xD0
86
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
87
REV. V1.2.1
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 68: RECEIVE CHANNEL CONTROL REGISTER X (RCCR 0-31)
BIT
FUNCTION
HEX ADDRESS: 0Xn360 TO 0XN37F
TYPE
DEFAULT
DESCRIPTION-OPERATION
Receive LAPD Control
These bits select which one of the three Receive LAPD controller will be configured to use D/E time slot (Octets 0-23) for receiving LAPD messages.
7
LAPDcntl[1]
R/W
1
6
LAPDcntl[0]
R/W
0
LAPDCNTL[1:0]
RECEIVE LAPD CONTROLLER SELECTED
00
Receive LAPD Controller 1
01
Receive LAPD Controller 2
10
The RxSIGDL[1:0] bits in the Receive Signaling and Data Link Select Register
(RSDLSR - Address - 0xn10C) determine
the data source for Receive D/E time slots.
11
Receive LAPD Controller 3
NOTE: All three LAPD Controller can use D/E timeslots for receiving LAPD
messages. However, only LAPD Controller 1 can use datalink for
reception.
NOTE: Register 0xn360 represents D/E time slot 0, and 0xn37F represents
D/E time slot 31.
5-4 Reserved
-
-
Reserved
88
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 68: RECEIVE CHANNEL CONTROL REGISTER X (RCCR 0-31)
BIT
FUNCTION
3-0 RxCOND[3:0]
TYPE
DEFAULT
R/W
0000
REV. V1.2.1
HEX ADDRESS: 0Xn360 TO 0XN37F
DESCRIPTION-OPERATION
Receive Channel Conditioning for Timeslot 0 to 31
These bits allow the user to substitute the input line data (Octets 0-31) with
internally generated Conditioning Codes prior to transmission to the backplane interface on a per-channel basis. The table below presents the different conditioning codes based on the setting of these bits.
NOTE: Register address 0xn300 represents time slot 0, and address 0xn31F
represents time slot 31.
RXCOND[1:0]
0x0 / 0xE
CONDITIONING CODES
Contents of timeslot octet are unchanged.
0x1
All 8 bits of the selected timeslot octet are inverted (1’s
complement)
OUTPUT = (TIME_SLOT_OCTET) XOR 0xFF
0x2
Even bits of the selected timeslot octet are inverted
OUTPUT = (TIME_SLOT_OCTET) XOR 0xAA
0x3
Odd bits of the selected time slot octet are inverted
OUTPUT = (TIME_SLOT_OCTET) XOR 0x55
0x4
Contents of the selected timeslot octet will be substituted
with the 8 -bit value in the Receive
Programmable User Code Register (0xn380-0xn397),
0x5
Contents of the timeslot octet will be substituted with the
value 0x7F (BUSY Code)
0x6
Contents of the timeslot octet will be substituted with the
value 0xFF (VACANT Code)
0x7
Contents of the timeslot octet will be substituted with the
BUSY time slot code (111#_####), where ##### is the
Timeslot number
0x8
Contents of the timeslot octet will be substituted with the
MOOF code (0x1A)
0x9
Contents of the timeslot octet will be substituted with the
A-Law Digital Milliwatt pattern
0xA
Contents of the timeslot octet will be substituted with the
µ-Law Digital Milliwatt pattern
0xB
The MSB (bit 1) of input data is inverted
0xC
All input data except MSB is inverted
0xD
Contents of the timeslot octet will be substituted with the
PRBS X15 + X 14 + 1/QRTS pattern
NOTE: PRBS X15 + X 14 + 1 or QRTS pattern depends on
PRBSType selected in the register 0xn123 - bit 7
0xF
D/E time slot - The RxSIGDL[2:0] bits in the Transmit Signaling and Data Link Select Register (0xn10C) will determine the data source for Receive D/E time slots.
89
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 69: RECEIVE USER CODE REGISTER 0-31 (RUCR 0-31)
BIT
FUNCTION
7-0 RxUSER[7:0]
HEX ADDRESS: 0Xn380 TO 0XN39F
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
11111111 Receive Programmable User code.
These eight bits allow users to program any code in this register to
replace the received data when the Receive Channel Control Register (RCCR) is configured to replace timeslot octet with the receive
programmable user code. (i.e. if RCCR is set to ‘0x4’)
90
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 70: RECEIVE SIGNALING CONTROL REGISTER 0-31 (RSCR 0-31)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0Xn3A0 TO 0XN3BF
TYPE
DEFAULT
DESCRIPTION-OPERATION
6
SIGC_ENB
R/W
0
Signaling substitution enable
This bit enables or disables signaling substitution on the receive
side on a per channel basis. Once signaling substitution is enabled,
received signaling bits ABCD will be substituted with the ABCD values in the Receive Substitution Signaling Register (RSSR).
Signaling substitution only occurs in the output PCM data
(RxSERn). Receive Signaling Array Register (RSAR - Address
0xn500-0xn51F) and the external Signaling bus (RxSIG_n) output
pin will not be affected.
0 = Disables signaling substitution on the receive side.
1 = Enables signaling substitution on the receive side.
5
OH_ENB
R/W
0
Signaling OH interface output enable
This bit enables or disables signaling information to output via the
Receive Overhead pin (RxOH_n) on a per channel basis. The signaling information in the receive signaling array registers (RSAR Address 0xn500-0xn51F) is output to the receive overhead output
pin (RxOH_n) if this bit is enabled.
0 = Disables signaling information to output via RxOH_n.
1 = Enables signaling information to output via RxOH_n.
4
DEB_ENB
R/W
0
Per-channel debounce enable
This bit enables or disables the signaling debounce feature on a per
channel basis.
When this feature is enabled, the per-channel signaling state must
be in the same state for 2 superframes before the Receive Framer
updates signaling information on the Receive Signaling Array Register (RSAR) and the Signaling Pin (RxSIGn). If the signaling bits for
two consecutive superframes are not the same, the current state of
RSAR and RxSIG will not change.
When this feature is disabled, RSAR and RxSIG will be updated as
soon as the receive signaling bits have changed.
0 = Disables the Signaling Debounce feature.
1 = Enables the Signaling Debounce feature.
91
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 70: RECEIVE SIGNALING CONTROL REGISTER 0-31 (RSCR 0-31)
BIT
FUNCTION
HEX ADDRESS: 0Xn3A0 TO 0XN3BF
TYPE
DEFAULT
DESCRIPTION-OPERATION
Signaling conditioning
These bits allow user to select the format of signaling substitution on
a per-channel basis, as presented in the table below.
3
RxSIGC[1]
R/W
0
2
RxSIGC[0]
R/W
0
RXSIGC[1:0]
1
RxSIGE[1]
R/W
0
0
RxSIGE[0]
R/W
0
SIGNALING SUBSTITUTION SCHEMES
00
Substitutes all signaling bits with one.
01
Enables 16-code (A,B,C,D) signaling substitution.
Users must write to bits 3-0 in the Receive Signaling Substitution Register (RSSR) to provide
the 16-code (A,B,C,D) signaling substitution values.
10
Enables 4-code (A,B) signaling substitution.
Users must write to bits 4-5 in the Receive Signaling Substitution Register (RSSR) to provide
the 4-code (A,B) signaling substitution values.
11
Enables 2-code (A) signaling substitution.
Users must write to bit 6 in the Receive Signaling Substitution Register (RSSR) to provide the
2-code (A) signaling substitution values.
Receive Signaling Extraction.
These bits control per-channel signaling extraction as presented in
the table below. Signaling information can be extracted to the
Receive Signaling Array Register (RSAR), the Receive Signaling
Output pin (RxSIG_n) if the Receive SIgnaling Interface is enable,
or the Receive Overhead Interface output (RxOH_n) if OH_ENB bit
is enabled. (bit 5 of this register).
RXSIGE[1:0]
92
SIGNALING EXTRACTION SCHEMES
00
No signaling information is extracted.
01
Enables 16-code (A,B,C,D) signaling
extraction.
All signaling bits A,B,C,D will be extracted.
10
Enables 4-code (A,B) signaling extraction
Only signaling bits A,B will be extracted.
11
Enables 2-code (A) signaling extraction
Only signaling bit A will be extracted.
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 71: RECEIVE SUBSTITUTION SIGNALING REGISTER 0-31 (RSSR 0-31)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS 0Xn3C0 TO 0XN3DF
TYPE
DEFAULT
DESCRIPTION-OPERATION
6
SIG2-A
R/W
0
2-code signaling A
This bit provides the value of signaling bit A to substitute the receive
signaling bit A on a per channel basis when 2-code signaling substitution is enabled. Register address 0xn3C0 represents time slot 0,
and 0xn3DF represents time slot 31.
5
SIG4-B
R/W
0
4-code signaling B
This bit provides the value of signaling bit B to substitute the receive
signaling bit B when 4-code signaling substitution is enabled. Register address 0xn3C0 represents time slot 0, and 0xn3DF represents
time slot 31.
4
SIG4-A
R/W
0
4-code signaling A
This bit provides the value of signaling bit A to substitute the receive
signaling bit A when 4-code signaling substitution is enabled. Register address 0xn3C0 represents time slot 0, and 0xn3DF represents
time slot 31.
3
SIG16-D
R/W
0
16-code signaling D
This bit provides the value of signaling bit D to substitute the receive
signaling bit D when 16-code signaling substitution is enabled. Register address 0xn3C0 represents time slot 0, and 0xn3DF represents time slot 31.
2
SIG16-C
R/W
0
16-code signaling C
This bit provides the value of signaling bit C to substitute the receive
signaling bit C when 16-code signaling substitution is enabled. Register address 0xn3C0 represents time slot 0, and 0xn3DF represents time slot 31.
1
SIG16-B
R/W
0
16-code signaling B
This bit provides the value of signaling bit B to substitute the receive
signaling bit B when 16-code signaling substitution is enabled. Register address 0xn3C0 represents time slot 0, and 0xn3DF represents time slot 31.
0
SIG16-A
R/W
0
16-code signaling A
This bit provides the value of signaling bit A to substitute the receive
signaling bit A when 16-code signaling substitution is enabled. Register address 0xn3C0 represents time slot 0, and 0xn3DF represents time slot 31.
93
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 72: RECEIVE SIGNALING ARRAY REGISTER 0 - 31 (RSAR 0-31)
BIT
FUNCTION
7-4 Reserved
HEX ADDRESS: 0Xn500 TO 0Xn51F
TYPE
DEFAULT
-
-
Reserved
These READ ONLY registers reflect the most recently received signaling value (A,B,C,D) associated with timeslot 0 to 31. If signaling
debounce feature is enabled, the received signaling state must be
the same for 2 superframes before this register is updated. If the
signaling bits for two consecutive superframes are not the same, the
current value of this register will not be changed.
If the signaling debounce or sig feature is disabled, this register is
updated as soon as the received signaling bits have changed.
3
A
RO
0
2
B
RO
0
1
C
RO
0
0
D
RO
0
DESCRIPTION-OPERATION
NOTE:
The content of this register only has meaning when the
framer is using Channel Associated Signaling.
94
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 73: LAPD BUFFER 0 CONTROL REGISTER (LAPDBCR0)
BIT
FUNCTION
7-0 LAPD Buffer 0
REV. V1.2.1
HEX ADDRESS: 0Xn600
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
LAPD Buffer 0 (96-Bytes) Auto Incrementing
This register is used to transmit and receive LAPD messages within
buffer 0 of the HDLC controller. Any one of the HDLC controller can
be is chosen in the LAPD Select Register (0xn11B). Users should
determine the next available buffer by reading the BUFAVAL bit (bit
7 of the Transmit Data Link Byte Count Register 1 (address 0xn114),
Register 2 (0xn144) and Register 3 (0xn154) depending on which
HDLC controller is selected. If buffer 0 is available, writing to buffer 0
will insert the message into the outgoing LAPD frame after the
LAPD message is sent and the data from the transmit buffer cannot
be retrieved.
After detecting the Receive end of transfer interrupt (RxEOT), users
should read the RBUFPTR bit (bit 7 of the Receive Data Link Byte
Count Register 1 (address 0xn115), Register 2 (0xn145), or Register 3 (0xn155) depending on which HDLC controller is selected) to
determine which buffer contains the received LAPD message ready
to be read. If RBUFPTR bit indicates that buffer 0 is available to be
read, reading buffer 0 (Register 0xn600) continuously will retrieve
the entire received LAPD message.
NOTE: When writing to or reading from Buffer 0, the register is
automatically incremented such that the entire 96 Byte
LAPD message can be written into or read from buffer 0
(Register 0xn600) continuously.
TABLE 74: LAPD BUFFER 1 CONTROL REGISTER (LAPDBCR1)
BIT
FUNCTION
7-0 LAPD Buffer 1
HEX ADDRESS: 0Xn700
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
LAPD Buffer 1 (96-Bytes) Auto Incrementing
This register is used to transmit and receive LAPD messages within
buffer 1 of the HDLC controller. Any one of the HDLC controller can
be is chosen in the LAPD Select Register (0xn11B). Users should
determine the next available buffer by reading the BUFAVAL bit (bit
7 of the Transmit Data Link Byte Count Register 1 (address 0xn114),
Register 2 (0xn144) and Register 3 (0xn154) depending on which
HDLC controller is selected. If buffer 1 is available, writing to buffer 1
will insert the message into the outgoing LAPD frame after the
LAPD message is sent and the data from the transmit buffer 1 cannot be retrieved.
After detecting the Receive end of transfer interrupt (RxEOT), users
should read the RBUFPTR bit (bit 7 of the Receive Data Link Byte
Count Register 1 (address 0xn115), Register 2 (0xn145), or Register 3 (0xn155) depending on which HDLC controller is selected) to
determine which buffer contains the received LAPD message ready
to be read. If RBUFPTR bit indicates that buffer 1 is available to be
read, reading buffer 1 (Register 0xn700) continuously will retrieve
the entire received LAPD message.
NOTE: When writing to or reading from Buffer 0, the register is
automatically incremented such that the entire 96 Byte
LAPD message can be written into or read from buffer 0
(Register 0xn600) continuously.
95
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 75: PMON RECEIVE LINE CODE VIOLATION COUNTER MSB (RLCVCU)
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor “Receive Line Code Violation” 16-Bit
Counter - Upper Byte:
These RESET-upon-READ bits, along with that within the PMON
Receive Line Code Violation Counter Register LSB combine to
reflect the cumulative number of instances that Line Code Violation
has been detected by the Receive E1 Framer block since the last
read of this register.
This register contains the Most Significant byte of this 16-bit of the
Line Code Violation counter.
7
RLCVC[15]
RUR
0
6
RLCVC[14]
RUR
0
5
RLCVC[13]
RUR
0
4
RLCVC[12]
RUR
0
3
RLCVC[11]
RUR
0
2
RLCVC[10]
RUR
0
1
RLCVC[9]
RUR
0
0
RLCVC[8]
RUR
0
NOTE: For all 16-bit wide PMON registers, user must read the MSB
counter first before reading the LSB counter in order to read
the accurate PMON counts. To clear PMON count, user
must read the MSB counter first before reading the LSB
counter in order to clear the PMON count.
TABLE 76: PMON RECEIVE LINE CODE VIOLATION COUNTER LSB (RLCVCL)
BIT
FUNCTION
HEX ADDRESS: 0Xn900
HEX ADDRESS: 0Xn901
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor “Receive Line Code Violation” 16-Bit
Counter - Lower Byte:
These RESET-upon-READ bits, along with that within the PMON
Receive Line Code Violation Counter Register MSB combine to
reflect the cumulative number of instances that Line Code Violation
has been detected by the Receive E1 Framer block since the last
read of this register.
This register contains the Least Significant byte of this 16-bit of the
Line Code Violation counter.
7
RLCVC[7]
RUR
0
6
RLCVC[6]
RUR
0
5
RLCVC[5]
RUR
0
4
RLCVC[4]
RUR
0
3
RLCVC[3]
RUR
0
2
RLCVC[2]
RUR
0
1
RLCVC[1]
RUR
0
0
RLCVC[0]
RUR
0
NOTE: For all 16-bit wide PMON registers, user must read the MSB
counter first before reading the LSB counter in order to read
the accurate PMON counts. To clear PMON count, user
must read the MSB counter first before reading the LSB
counter in order to clear the PMON count.
96
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
.
TABLE 77: PMON RECEIVE FRAMING ALIGNMENT BIT ERROR COUNTER MSB (RFAECU) HEX ADDRESS: 0Xn902
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor “Receive Framing Alignment Error 16-Bit
Counter” - Upper Byte:
These RESET-upon-READ bits, along with that within the “PMON
Receive Framing Alignment Error Counter Register LSB” combine
to reflect the cumulative number of instances that the Receive
Framing Alignment errors has been detected by the Receive E1
Framer block since the last read of this register.
This register contains the Most Significant byte of this 16-bit of the
Receive Framing Alignment Error counter.
7
RFAEC[15]
RUR
0
6
RFAEC[14]
RUR
0
5
RFAEC[13]
RUR
0
4
RFAEC[12]
RUR
0
3
RFAEC[11]
RUR
0
2
RFAEC[10]
RUR
0
1
RFAEC[9]
RUR
0
0
RFAEC[8]
RUR
0
NOTE: For all 16-bit wide PMON registers, user must read the MSB
counter first before reading the LSB counter in order to read
the accurate PMON counts. To clear PMON count, user
must read the MSB counter first before reading the LSB
counter in order to clear the PMON count.
.
TABLE 78: PMON RECEIVE FRAMING ALIGNMENT BIT ERROR COUNTER LSB (RFAECL)
BIT
FUNCTION
HEX ADDRESS: 0Xn903
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor “Receive Framing Alignment Error 16-Bit
Counter” - Lower Byte:
These RESET-upon-READ bits, along with that within the “PMON
Receive Framing Alignment Error Counter Register MSB” combine
to reflect the cumulative number of instances that the Receive
Framing Alignment errors has been detected by the Receive E1
Framer block since the last read of this register.
This register contains the Least Significant byte of this 16-bit of the
Receive Framing Alignment Error counter.
7
RFAEC[7]
RUR
0
6
RFAEC[6]
RUR
0
5
RFAEC[5]
RUR
0
4
RFAEC[4]
RUR
0
3
RFAEC[3]
RUR
0
2
RFAEC[2]
RUR
0
1
RFAEC[1]
RUR
0
0
RFAEC[0]
RUR
0
NOTE: For all 16-bit wide PMON registers, user must read the MSB
counter first before reading the LSB counter in order to read
the accurate PMON counts. To clear PMON count, user
must read the MSB counter first before reading the LSB
counter in order to clear the PMON count.
97
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 79: PMON RECEIVE SEVERELY ERRORED FRAME COUNTER (RSEFC)
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor - Receive Severely Errored frame Counter
(8-bit Counter)
These Reset-Upon-Read bit fields reflect the cumulative number of
instances that Receive Severely Errored Frames have been
detected by the E1 Framer since the last read of this register.
Severely Errored Frame is defined as the occurrence of two consecutive errored frame alignment signals without causing loss of frame
condition.
7
RSEFC[7]
RUR
0
6
RSEFC[6]
RUR
0
5
RSEFC[5]
RUR
0
4
RSEFC[4]
RUR
0
3
RSEFC[3]
RUR
0
2
RSEFC[2]
RUR
0
1
RSEFC[1]
RUR
0
0
RSEFC[0]
RUR
0
TABLE 80: PMON RECEIVE CRC-4 BIT ERROR COUNTER - MSB (RSBBECU)
BIT
FUNCTION
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor “Receive Synchronization Bit Error 16-Bit
Counter” - Upper Byte:
These RESET-upon-READ bits, along with that within the “PMON
Receive Synchronization Bit Error Counter Register LSB” combine
to reflect the cumulative number of instances that the Receive Synchronization Bit errors has been detected by the Receive E1 Framer
block since the last read of this register.
This register contains the Most Significant byte of this 16-bit of the
Receive Synchronization Bit Error counter.
RSBBEC[15]
RUR
0
6
RSBBEC[14]
RUR
0
5
RSBBEC[13]
RUR
0
4
RSBBEC[12]
RUR
0
3
RSBBEC[11]
RUR
0
2
RSBBEC[10]
RUR
0
1
RSBBEC[9]
RUR
0
0
RSBBEC[8]
RUR
0
NOTE: For all 16-bit wide PMON registers, user must read the MSB
counter first before reading the LSB counter in order to read
the accurate PMON counts. To clear PMON count, user
must read the MSB counter first before reading the LSB
counter in order to clear the PMON count.
TABLE 81: PMON RECEIVE CRC-4 BLOCK ERROR COUNTER - LSB (RSBBECL)
FUNCTION
HEX ADDRESS: 0Xn905
TYPE
7
BIT
HEX ADDRESS: 0Xn904
HEX ADDRESS: 0Xn906
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor “Receive Synchronization Bit Error 16-Bit
Counter” - Lower Byte:
These RESET-upon-READ bits, along with that within the “PMON
Receive Synchronization Bit Error Counter Register MSB” combine
to reflect the cumulative number of instances that the Receive Synchronization Bit errors has been detected by the Receive E1 Framer
block since the last read of this register.
This register contains the Least Significant byte of this 16-bit of the
Receive Synchronization Bit Error counter.
7
RSBBEC[7]
RUR
0
6
RSBBEC[6]
RUR
0
5
RSBBEC[5]
RUR
0
4
RSBBEC[4]
RUR
0
3
RSBBEC[3]
RUR
0
2
RSBBEC[2]
RUR
0
1
RSBBEC[1]
RUR
0
0
RSBBEC[0]
RUR
0
NOTE: For all 16-bit wide PMON registers, user must read the MSB
counter first before reading the LSB counter in order to read
the accurate PMON counts. To clear PMON count, user
must read the MSB counter first before reading the LSB
counter in order to clear the PMON count.
98
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 82: PMON RECEIVE FAR-END BLOCK ERROR COUNTER - MSB (RFEBECU)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0Xn907
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor - Receive Far-End Block Error 16-Bit
Counter - Upper Byte:
These RESET-upon-READ bits, along with that within the “PMON
Receive Far-End Block Error Counter Register LSB” combine to
reflect the cumulative number of instances that the Receive Far-End
Block errors has been detected by the Receive E1 Framer block
since the last read of this register.
This register contains the Most Significant byte of this 16-bit of the
Receive Far-End Block Error counter.
7
RFEBEC[15]
RUR
0
6
RFEBEC[14]
RUR
0
5
RFEBEC[13]
RUR
0
4
RFEBEC[12]
RUR
0
3
RFEBEC[11]
RUR
0
2
RFEBEC[10]
RUR
0
1
RFEBEC[9]
RUR
0
0
RFEBEC[8]
RUR
0
NOTE: The Receive Far-End Block Error Counter will increment
once each time the received E-bit is set to zero. This
counter is disabled during loss of sync at either the FAS or
CRC-4 level and it will continue to count if loss of multiframe
sync occurs at the CAS level.
NOTE: For all 16-bit wide PMON registers, user must read the MSB
counter first before reading the LSB counter in order to read
the accurate PMON counts. To clear PMON count, user
must read the MSB counter first before reading the LSB
counter in order to clear the PMON count.
TABLE 83: PMON RECEIVE FAR END BLOCK ERROR COUNTER -LSB (RFEBECL)
BIT
FUNCTION
HEX ADDRESS: 0Xn908
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor - Receive Far-End Block Error 16-Bit
Counter - Lower Byte:
These RESET-upon-READ bits, along with that within the “PMON
Receive Far-End Block Error Counter Register MSB” combine to
reflect the cumulative number of instances that the Receive Far-End
Block errors has been detected by the Receive E1 Framer block
since the last read of this register.
This register contains the Least Significant byte of this 16-bit of the
Receive Far-End Block Error counter.
7
RFEBEC[7]
RUR
0
6
RFEBEC[6]
RUR
0
5
RFEBEC[5]
RUR
0
4
RFEBEC[4]
RUR
0
3
RFEBEC[3]
RUR
0
2
RFEBEC[2]
RUR
0
1
RFEBEC[1]
RUR
0
0
RFEBEC[0]
RUR
0
NOTE: The Receive Far-End Block Error Counter will increment
once each time the received E-bit is set to zero. This
counter is disabled during loss of sync at either the FAS or
CRC-4 level and it will continue to count if loss of multiframe
sync occurs at the CAS level.
NOTE: For all 16-bit wide PMON registers, user must read the MSB
counter first before reading the LSB counter in order to read
the accurate PMON counts. To clear PMON count, user
must read the MSB counter first before reading the LSB
counter in order to clear the PMON count.
99
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 84: PMON RECEIVE SLIP COUNTER (RSC)
BIT
FUNCTION
HEX ADDRESS: 0Xn909
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
RSC[7]
RUR
0
6
RSC[6]
RUR
0
5
RSC[5]
RUR
0
Performance Monitor - Receive Slip Counter (8-bit Counter)
These Reset-Upon-Read bit fields reflect the cumulative number of
instances that Receive Slip events have been detected by the E1
Framer since the last read of this register.
4
RSC[4]
RUR
0
NOTE: A slip event is defined as a replication or deletion of a E1
frame by the receive slip buffer.
3
RSC[3]
RUR
0
2
RSC[2]
RUR
0
1
RSC[1]
RUR
0
0
RSC[0]
RUR
0
TABLE 85: PMON RECEIVE LOSS OF FRAME COUNTER (RLFC)
BIT
FUNCTION
HEX ADDRESS: 0Xn90A
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor - Receive Loss of Frame Counter (8-bit
Counter)
These Reset-Upon-Read bit fields reflect the cumulative number of
instances that Receive Loss of Frame condition have been detected
by the E1 Framer since the last read of this register.
7
RLFC[7]
RUR
0
6
RLFC[6]
RUR
0
5
RLFC[5]
RUR
0
4
RLFC[4]
RUR
0
3
RLFC[3]
RUR
0
2
RLFC[2]
RUR
0
1
RLFC[1]
RUR
0
0
RLFC[0]
RUR
0
NOTE: This counter counts once every time the Loss of Frame
condition is declared. This counter provides the capability to
measure an accumulation of short failure events.
TABLE 86: PMON RECEIVE CHANGE OF FRAME ALIGNMENT COUNTER (RCFAC)
BIT
FUNCTION
HEX ADDRESS: 0Xn90B
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor - Receive Change of Frame Alignment
Counter (8-bit Counter)
These Reset-Upon-Read bit fields reflect the cumulative number of
instances that Receive Change of Framing Alignment have been
detected by the E1 Framer since the last read of this register.
7
RCFAC[7]
RUR
0
6
RCFAC[6]
RUR
0
5
RCFAC[5]
RUR
0
4
RCFAC[4]
RUR
0
3
RCFAC[3]
RUR
0
2
RCFAC[2]
RUR
0
1
RCFAC[1]
RUR
0
0
RCFAC[0]
RUR
0
NOTE: Change of Framing Alignment (COFA) is declared when the
newly-locked framing pattern is different from the one
offered by off-line framer.
100
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 87: PMON LAPD FRAME CHECK SEQUENCE ERROR COUNTER 1 (LFCSEC1)
BIT
FUNCTION
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor - LAPD 1 Frame Check Sequence Error
Counter (8-bit Counter)
These Reset-Upon-Read bit fields reflect the cumulative number of
instances that Frame Check Sequence Error have been detected by
the LAPD Controller 1 since the last read of this register.
FCSEC1[7]
RUR
0
6
FCSEC1[6]
RUR
0
5
FCSEC1[5]
RUR
0
4
FCSEC1[4]
RUR
0
3
FCSEC1[3]
RUR
0
2
FCSEC1[2]
RUR
0
1
FCSEC1[1]
RUR
0
0
FCSEC1[0]
RUR
0
TABLE 88: PMON PRBS BIT ERROR COUNTER MSB (PBECU)
FUNCTION
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor - E1 PRBS Bit Error 16-Bit Counter Upper Byte:
These RESET-upon-READ bits, along with that within the “PMON
E1 PRBS Bit Error Counter Register LSB” combine to reflect the
cumulative number of instances that the ReceiveE1 PRBS Bit errors
has been detected by the Receive E1 Framer block since the last
read of this register.
This register contains the Most Significant byte of this 16-bit of the
Receive E1 PRBS Bit Error counter.
PRBSE[15]
RUR
0
6
PRBSE[14]
RUR
0
5
PRBSE[13]
RUR
0
4
PRBSE[12]
RUR
0
3
PRBSE[11]
RUR
0
2
PRBSE[10]
RUR
0
1
PRBSE[9]
RUR
0
0
PRBSE[8]
RUR
0
NOTE: For all 16-bit wide PMON registers, user must read the MSB
counter first before reading the LSB counter in order to read
the accurate PMON counts. To clear PMON count, user
must read the MSB counter first before reading the LSB
counter in order to clear the PMON count.
TABLE 89: PMON PRBS BIT ERROR COUNTER LSB (PBECL)
FUNCTION
HEX ADDRESS: 0Xn90D
TYPE
7
BIT
HEX ADDRESS: 0Xn90C
TYPE
7
BIT
REV. V1.2.1
HEX ADDRESS: 0Xn90E
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor - E1 PRBS Bit Error 16-Bit Counter Lower Byte:
These RESET-upon-READ bits, along with that within the “PMON
E1 PRBS Bit Error Counter Register MSB” combine to reflect the
cumulative number of instances that the ReceiveE1 PRBS Bit errors
has been detected by the Receive E1 Framer block since the last
read of this register.
This register contains the Least Significant byte of this 16-bit of the
Receive E1 PRBS Bit Error counter.
7
PRBSE[7]
RUR
0
6
PRBSE[6]
RUR
0
5
PRBSE[5]
RUR
0
4
PRBSE[4]
RUR
0
3
PRBSE[3]
RUR
0
2
PRBSE[2]
RUR
0
1
PRBSE[1]
RUR
0
0
PRBSE[0]
RUR
0
NOTE: For all 16-bit wide PMON registers, user must read the MSB
counter first before reading the LSB counter in order to read
the accurate PMON counts. To clear PMON count, user
must read the MSB counter first before reading the LSB
counter in order to clear the PMON count.
101
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 90: PMON TRANSMIT SLIP COUNTER (TSC)
BIT
FUNCTION
HEX ADDRESS: 0Xn90F
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
TxSLIP[7]
RUR
0
6
TxSLIP[6]
RUR
0
5
TxSLIP[5]
RUR
0
Performance Monitor - Transmit Slip Counter (8-bit Counter)
These Reset-Upon-Read bit fields reflect the cumulative number of
instances that Transmit Slip events have been detected by the E1
Framer since the last read of this register.
4
TxSLIP[4]
RUR
0
NOTE: A slip event is defined as a replication or deletion of a E1
frame by the transmit slip buffer.
3
TxSLIP[3]
RUR
0
2
TxSLIP[2]
RUR
0
1
TxSLIP[1]
RUR
0
0
TxSLIP[0]
RUR
0
TABLE 91: PMON EXCESSIVE ZERO VIOLATION COUNTER MSB (EZVCU)
BIT
FUNCTION
TYPE
DEFAULT
7
EZVC[15]
RUR
0
6
EZVC[14]
RUR
0
5
EZVC[13]
RUR
0
4
EZVC[12]
RUR
0
3
EZVC[11]
RUR
0
2
EZVC[10]
RUR
0
1
EZVC[9]
RUR
0
0
EZVC[8]
RUR
0
DESCRIPTION-OPERATION
Performance Monitor - E1 Excessive Zero Violation 16-Bit
Counter - Upper Byte:
These RESET-upon-READ bits, along with that within the “PMON
E1 Excessive Zero Violation Counter Register LSB” combine to
reflect the cumulative number of instances that the ReceiveE1
Excessive Zero Violation has been detected by the Receive E1
Framer block since the last read of this register.
This register contains the Most Significant byte of this 16-bit of the
Receive E1 Excessive Zero Violation counter.
NOTE: For all 16-bit wide PMON registers, user must read the MSB
counter first before reading the LSB counter in order to read
the accurate PMON counts. To clear PMON count, user
must read the MSB counter first before reading the LSB
counter in order to clear the PMON count.
TABLE 92: PMON EXCESSIVE ZERO VIOLATION COUNTER LSB (EZVCL)
BIT
FUNCTION
HEX ADDRESS: 0Xn910
HEX ADDRESS: 0Xn911
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor - E1 Excessive Zero Violation 16-Bit
Counter - Lower Byte:
These RESET-upon-READ bits, along with that within the “PMON
E1 Excessive Zero Violation Counter Register MSB” combine to
reflect the cumulative number of instances that the ReceiveE1
Excessive Zero Violation has been detected by the Receive E1
Framer block since the last read of this register.
This register contains the Least Significant byte of this 16-bit of the
Receive E1 Excessive Zero Violation counter.
7
EZVC[7]
RUR
0
6
EZVC[6]
RUR
0
5
EZVC[5]
RUR
0
4
EZVC[4]
RUR
0
3
EZVC[3]
RUR
0
2
EZVC[2]
RUR
0
1
EZVC[1]
RUR
0
0
EZVC[0]
RUR
0
NOTE: For all 16-bit wide PMON registers, user must read the MSB
counter first before reading the LSB counter in order to read
the accurate PMON counts. To clear PMON count, user
must read the MSB counter first before reading the LSB
counter in order to clear the PMON count.
102
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 93: PMON FRAME CHECK SEQUENCE ERROR COUNTER 2 (LFCSEC2)
BIT
FUNCTION
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor - LAPD 2 Frame Check Sequence Error
Counter (8-bit Counter)
These Reset-Upon-Read bit fields reflect the cumulative number of
instances that Frame Check Sequence Error have been detected by
the LAPD Controller 2 since the last read of this register.
FCSEC2[7]
RUR
0
6
FCSEC2[6]
RUR
0
5
FCSEC2[5]
RUR
0
4
FCSEC2[4]
RUR
0
3
FCSEC2[3]
RUR
0
2
FCSEC2[2]
RUR
0
1
FCSEC2[1]
RUR
0
0
FCSEC2[0]
RUR
0
TABLE 94: PMON FRAME CHECK SEQUENCE ERROR COUNTER 3 (LFCSEC3)
FUNCTION
HEX ADDRESS: 0Xn91C
TYPE
7
BIT
REV. V1.2.1
HEX ADDRESS: 0Xn92C
TYPE
DEFAULT
DESCRIPTION-OPERATION
Performance Monitor - LAPD 3 Frame Check Sequence Error
Counter (8-bit Counter)
These Reset-Upon-Read bit fields reflect the cumulative number of
instances that Frame Check Sequence Error have been detected by
the LAPD Controller 3 since the last read of this register.
7
FCSEC3[7]
RUR
0
6
FCSEC3[6]
RUR
0
5
FCSEC3[5]
RUR
0
4
FCSEC3[4]
RUR
0
3
FCSEC3[3]
RUR
0
2
FCSEC3[2]
RUR
0
1
FCSEC3[1]
RUR
0
0
FCSEC3[0]
RUR
0
103
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 95: BLOCK INTERRUPT STATUS REGISTER (BISR)
BIT
7
FUNCTION
Sa6
TYPE
DEFAULT
DESCRIPTION-OPERATION
RO
0
Sa6 Block Interrupt Status
This bit Indicates whether or not the SA 6 block has an interrupt
request awaiting service.
0 - Indicates no outstanding SA 6 block interrupt request is awaiting
service
1 - Indicates the SA 6 block has an interrupt request awaiting service. Interrupt Service routine should branch to the interrupt source
and read the SA6 block Interrupt Status register (address 0xnB0C)
to clear the interrupt
NOTE:
6
Reserved
5
RxClkLOS
HEX ADDRESS: 0XnB00
This bit will be reset to 0 after the microprocessor has
performed a read to the SA6 Interrupt Status Register
For T1 mode only
RO
0
Loss of Recovered Clock Interrupt Status
This bit Indicates whether or not the Recovered Clock has an interrupt request awaiting service.
0 - Indicates no outstanding SA 6 block interrupt request is awaiting
service
1 - Indicates the SA 6 block has an interrupt request awaiting service.
This bit indicates whether or not the framer has experienced a Loss
of Recovered Clock interrupt since last read of this register.
0 = Indicates Loss of Recovered Clock interrupt has not occurred
since last read of this register
1 = Indicates Loss of Recovered Clock interrupt has occurred since
last read of this register.
NOTE: This bit is only active if the clock loss detection feature is
enabled (Register - 0xn100)
4
ONESEC
RO
0
One Second Interrupt Status
This bit indicates whether or not the framer has experienced a One
Second interrupt since the last read of this register.
0 = Indicates One Second interrupt has not occurred since the last
read of this register
1 = Indicates One Second interrupt has occurred since the last read
of this register
3
HDLC
RO
0
HDLC Block Interrupt Status
This bit indicates whether or not the HDLC block has any interrupt
request awaiting service.
0 = Indicates no outstanding HDLC block interrupt request is awaiting service
1 = Indicates HDLC Block has an interrupt request awaiting service.
Interrupt Service routine should branch to the interrupt source and
read the corresponding Data Link Status Registers (address
0xnB06, 0xnB16, 0xnB26, 0xnB10, 0xnB18, 0xnB28) to clear the
interrupt.
NOTE:
This bit will be reset to 0 after the microprocessor has
performed a read to the corresponding Data Link Status
Registers that generated the interrupt.
104
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 95: BLOCK INTERRUPT STATUS REGISTER (BISR)
BIT
2
FUNCTION
SLIP
ALARM
DEFAULT
DESCRIPTION-OPERATION
RO
0
Slip Buffer Block Interrupt Status
This bit indicates whether or not the Slip Buffer block has any outstanding interrupt request awaiting service.
0 = Indicates no outstanding Slip Buffer Block interrupt request is
awaiting service
1 = Indicates Slip Buffer block has an interrupt request awaiting service. Interrupt Service routine should branch to the interrupt source
and read the Slip Buffer Interrupt Status register (address 0xnB08)
to clear the interrupt
RO
0
E1 FRAME
RO
0
This bit will be reset to 0 after the microprocessor has
performed a read to the Slip Buffer Interrupt Status
Register.
Alarm & Error Block Interrupt Status
This bit indicates whether or not the Alarm & Error Block has any
outstanding interrupt request awaiting service.
0 = Indicates no outstanding interrupt request is awaiting service
1 = Indicates the Alarm & Error Block has an interrupt request awaiting service. Interrupt service routine should branch to the interrupt
source and read the corresponding alarm and error status registers
(address 0xnB02, 0xnB0E, 0xnB40) to clear the interrupt.
NOTE:
0
HEX ADDRESS: 0XnB00
TYPE
NOTE:
1
REV. V1.2.1
This bit will be reset to 0 after the microprocessor has
performed a read to the corresponding Alarm & Error
Interrupt Status register that generated the interrupt.
E1 Framer Block Interrupt Status
This bit indicates whether or not the E1 Framer block has any outstanding interrupt request awaiting service.
0 = Indicates no outstanding interrupt request is awaiting service.
1 = Indicates the E1 Framer Block has an interrupt request awaiting
service. Interrupt service routine should branch to the interrupt
source and read the E1 Framer status register (address 0xnB04) to
clear the interrupt
NOTE:
This bit will be reset to 0 after the microprocessor has
performed a read to the E1 Framer Interrupt Status register.
105
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 96: BLOCK INTERRUPT ENABLE REGISTER (BIER)
BIT
FUNCTION
HEX ADDRESS: 0XnB01
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
SA6 Block interrupt enable
This bit permits the user to either enable or disable the SA 6 Block
for interrupt generation.
If the user writes a “0” to this register bit and disables the SA 6 Block
for interrupt generation, then all SA 6 interrupts will be disabled for
interrupt generation.
If the user writes a “1” to this register bit, the SA6 Block interrupt at
the “Block Level” will be enabled. However, the individual SA 6 interrupts at the “Source Level” still need to be enabled in order to generate that particular interrupt to the interrupt pin.
0 - Disables all SA6 Block interrupt within the device.
1 - Enables the SA6 interrupt at the “Block-Level”.
7
SA6_ENB
6
Reserved
5
RXCLKLOSS
R/W
0
Loss of Recovered Clock Interrupt Enable
This bit permits the user to either enable or disable the Loss of
Recovered Clock Interrupt for interrupt generation.
0 - Disables the Loss of Recovered Clock Interrupt within the device.
1 - Enables the Loss of Recovered Clock interrupt at the “SourceLevel”.
4
ONESEC_ENB
R/W
0
One Second Interrupt Enable
This bit permits the user to either enable or disable the One Second
Interrupt for interrupt generation.
0 - Disables the One Second Interrupt within the device.
1 - Enables the One Second interrupt at the “Source-Level”.
3
HDLC_ENB
R/W
0
HDLC Block Interrupt Enable
This bit permits the user to either enable or disable the HDLC Block
for interrupt generation.
If the user writes a “0” to this register bit and disables the HDLC
Block for interrupt generation, then all HDLC interrupts will be disabled for interrupt generation.
If the user writes a “1” to this register bit, the HDLC Block interrupt at
the “Block Level” will be enabled. However, the individual HDLC
interrupts at the “Source Level” still need to be enabled in order to
generate that particular interrupt to the interrupt pin.
0 - Disables all SA6 Block interrupt within the device.
1 - Enables the SA6 interrupt at the “Block-Level”.
2
SLIP_ENB
R/W
0
Slip Buffer Block Interrupt Enable
This bit permits the user to either enable or disable the Slip Buffer
Block for interrupt generation.
If the user writes a “0” to this register bit and disables the Slip Buffer
Block for interrupt generation, then all Slip Buffer interrupts will be
disabled for interrupt generation.
If the user writes a “1” to this register bit, the Slip Buffer Block interrupt at the “Block Level” will be enabled. However, the individual Slip
Buffer interrupts at the “Source Level” still need to be enabled in
order to generate that particular interrupt to the interrupt pin.
0 - Disables all Slip Buffer Block interrupt within the device.
1 - Enables the Slip Buffer interrupt at the “Block-Level”.
For T1 mode only
106
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 96: BLOCK INTERRUPT ENABLE REGISTER (BIER)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0XnB01
TYPE
DEFAULT
DESCRIPTION-OPERATION
1
ALARM_ENB
R/W
0
Alarm & Error Block Interrupt Enable
This bit permits the user to either enable or disable the Alarm &
Error Block for interrupt generation.
If the user writes a “0” to this register bit and disables the Alarm &
Error Block for interrupt generation, then all Alarm & Error interrupts
will be disabled for interrupt generation.
If the user writes a “1” to this register bit, the Alarm & Error Block
interrupt at the “Block Level” will be enabled. However, the individual
Alarm & Error interrupts at the “Source Level” still need to be
enabled in order to generate that particular interrupt to the interrupt
pin.
0 - Disables all Alarm & Error Block interrupt within the device.
1 - Enables the Alarm & Error interrupt at the “Block-Level”.
0
E1FRAME_ENB
R/W
0
E1 Framer Block Enable
This bit permits the user to either enable or disable the E1 Framer
Block for interrupt generation.
If the user writes a “0” to this register bit and disables the E1 Framer
Block for interrupt generation, then all E1 Framer interrupts will be
disabled for interrupt generation.
If the user writes a “1” to this register bit, the E1 Framer Block interrupt at the “Block Level” will be enabled. However, the individual E1
Framer interrupts at the “Source Level” still need to be enabled in
order to generate that particular interrupt to the interrupt pin.
0 - Disables all E1 Framer Block interrupt within the device.
1 - Enables the E1 Framer interrupt at the “Block-Level”.
107
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 97: ALARM & ERROR INTERRUPT STATUS REGISTER (AEISR)
BIT
FUNCTION
HEX ADDRESS: 0XnB02
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
Rx LOF State
RO
0
Receive Loss of Frame State
This READ-ONLY bit indicates whether or not the Receive E1 Framer block
is currently declaring the “Loss of Frame” condition within the incoming E1
data-stream, as described below.
Loss of Frame is declared when “FASC” number of consecutive frames,
where “FASC” indicates the Loss of FAS Alignment Criteria in the Framing
Control Register (0xn10B), bit 2-0.
0 – The Receive E1 Framer block is NOT currently declaring the “Loss of
Frame” condition.
1 – The Receive E1 Framer block is currently declaring the “Loss of Frame”
condition.
6
RxAIS State
RO
0
Receive Alarm Indication Status Defect State
This READ-ONLY bit indicates whether or not the Receive E1 Framer block
is currently declaring the AIS defect condition within the incoming E1 datastream, as described below.
AIS defect is declared when AIS condition persists for 250 microseconds (2
frames). AIS defect is cleared when more than 2 zeros are detected in two
consecutive frames (250us)
0 – The Receive E1 Framer block is NOT currently declaring the AIS defect
condition.
1 – The Receive E1 Framer block is currently declaring the AIS defect condition.
5
RxMYEL Status
RUR/
WC
0
Change of CAS Multiframe Yellow Alarm Interrupt Status.
This Reset-Upon-Read bit field indicates whether or not the CAS multiframe
yellow alarm interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will generate
an interrupt in response to either one of the following conditions.
1. Whenever the Receive E1 Framer block declares the CAS Multiframe
Yellow Alarm.
2. Whenever the Receive E1 Framer block clears the CAS Multiframe
Yellow Alarm
CAS Multiframe Yellow Alarm is declared whenever the received ‘y’ bit in
Time Slot 16 of Frame 0 is set to ‘1’.
0 = Indicates that the “Change of CAS Multiframe Yellow Alarm” interrupt
has not occurred since the last read of this register.
1 = Indicates that the “Change of CAS Multiframe Yellow Alarm” interrupt
has occurred since the last read of this register.
4
LOS State
RO
0
Framer Receive Loss of Signal (LOS) State
This READ-ONLY bit indicates whether or not the Receive E1 framer is currently declaring the Loss of Signal (LOS) condition within the incoming DS1
data-stream, as described below
LOS defect is declared when LOS condition persists for 175 consecutive
bits. LOS defect is cleared when LOS condition is absent or when the
received signal reaches a 12.5% ones density for 175 consecutive bits.
0 = The Receive DS1 Framer block is NOT currently declaring the Loss of
Signal (LOS) condition.
1 = The Receive DS1 Framer block is currently declaring the Loss of Signal
(LOS) condition.
108
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 97: ALARM & ERROR INTERRUPT STATUS REGISTER (AEISR)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0XnB02
TYPE
DEFAULT
DESCRIPTION-OPERATION
3
LCV Int Status
RUR/
WC
0
Line Code Violation Interrupt Status.
This Reset-Upon-Read bit field indicates whether or not the Receive E1 LIU
block has detected a Line Code Violation interrupt since the last read of this
register.
0 = Indicates that the Line Code Violation interrupt has not occurred since
the last read of this register.
1 = Indicates that the Line Code Violation interrupt has occurred since the
last read of this register.
2
Rx LOF State
Change
RUR/
WC
0
Change in Loss of Frame Condition Interrupt Status.
This Reset-Upon-Read bit field indicates whether or not the “Change in
Receive Loss of Frame Condition” interrupt has occurred since the last read
of this register.
If this interrupt is enabled, then the Receive E1 Framer block will generate
an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block declares the Loss of Frame
condition.
2. Whenever the Receive E1 Framer block clears the Loss of Frame
condition
0 = Indicates that the “Change in Receive Loss of Frame condition” interrupt
has not occurred since the last read of this register
1 = Indicates that the “Change in Receive Loss of Frame condition” interrupt
has occurred since the last read of this register
1
RxAIS State
Change
RUR/
WC
0
Change in Receive AIS Condition Interrupt Status.
This Reset-Upon-Read bit field indicates whether or not the “Change in
Receive AIS Condition” interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will generate
an interrupt in response to either one of the following conditions.
1. Whenever the Receive E1 Framer block declares the AIS condition.
2. Whenever the Receive E1 Framer block clears the AIS condition
0 = Indicates that the “Change in Receive AIS condition” interrupt has not
occurred since the last read of this register
1 = Indicates that the “Change in Receive AIS condition” interrupt has
occurred since the last read of this register
0
RxYEL State
Change
RUR/
WC
0
Change in Receive Yellow Alarm Interrupt Status.
This Reset-Upon-Read bit field indicates whether or not the “Change in
Receive Yellow Alarm Condition” interrupt has occurred since the last read
of this register.
If this interrupt is enabled, then the Receive E1 Framer block will generate
an interrupt in response to either one of the following conditions.
1. Whenever the Receive E1 Framer block declares the Yellow Alarm
condition.
2. Whenever the Receive E1 Framer block clears the Yellow Alarm
condition
0 = Indicates that the “Change in Receive Yellow Alarm condition” interrupt
has not occurred since the last read of this register
1 = Indicates that the “Change in Receive Yellow Alarm condition” interrupt
has occurred since the last read of this register
109
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 98: ALARM & ERROR INTERRUPT ENABLE REGISTER (AEIER)
HEX ADDRESS: 0XnB03
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
Rx_YEL_STATE
RO
0
Receive Yellow Alarm State
This READ-ONLY bit indicates whether or not the Receive E1 Framer block
is currently declaring the Yellow Alarm condition within the incoming E1
data-stream, as described below.
Yellow alarm or Remote Alarm Indication (RAI) is declared when the ‘A’ bit
of two consecutive non-FAS frames is set to ‘1’, which is equivalent to taking 375us to declare a RAI condition. Yellow alarm is cleared when the ‘A’
bit of two consecutive non-FAS frames is set to 0, which is equivalent to
taking 375us to clear a RAI condition.
0 – The Receive E1 Framer block is NOT currently declaring the Yellow
Alarm condition.
1 – The Receive E1 Framer block is currently declaring the Yellow Alarm
condition.
6
Reserved
-
-
Reserved
5
RxMYEL ENB
R/W
0
Change of CAS Multiframe Yellow Alarm Interrupt Enable.
This bit permits the user to either enable or disable the “Change in CAS
Multiframe Yellow Alarm”
Interrupt, within the XRT86VL38 device. If the user enables this interrupt,
then the Receive E1 Framer block will generate an interrupt in response to
either one of the following conditions.
1. The instant that the Receive E1 Framer block declares CAS
Multiframe Yellow Alarm.
2. The instant that the Receive E1 Framer block clears the CAS
Multiframe Yellow Alarm.
0 – Disables the “Change in CAS Multiframe Yellow Alarm” Interrupt.
1 – Enables the “Change in CAS Multiframe Yellow Alarm” Interrupt.
4
-
R/W
0
This bit should be set to’0’ for proper operation.
3
LCV ENB
R/W
0
Line Code violation interrupt enable
This bit permits the user to either enable or disable the “Line Code Violation” interrupt within the XRT86VL38 device. If the user enables this interrupt, then the Receive E1 Framer block will generate an interrupt when
Line Code Violation is detected.
0 = Disables the interrupt generation when Line Code Violation is detected.
1 = Enables the interrupt generation when Line Code Violation is detected.
2
RxLOF ENB
R/W
0
Change in Loss of Frame Condition interrupt enable
This bit permits the user to either enable or disable the “Change in Loss of
Frame Condition” Interrupt, within the XRT86VL38 device. If the user
enables this interrupt, then the Receive E1 Framer block will generate an
interrupt in response to either one of the following conditions.
1. The instant that the Receive E1 Framer block declares the Loss of
Frame condition.
2. The instant that the Receive E1 Framer block clears the Loss of
Frame condition.
0 – Disables the “Change in Loss of Frame Condition” Interrupt.
1 – Enables the “Change in Loss of Frame Condition” Interrupt.
110
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 98: ALARM & ERROR INTERRUPT ENABLE REGISTER (AEIER)
BIT
1
FUNCTION
RxAIS ENB
REV. V1.2.1
HEX ADDRESS: 0XnB03
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Change in AIS Condition interrupt enable
This bit permits the user to either enable or disable the “Change in AIS
Condition” Interrupt, within the XRT86VL38 device. If the user enables this
interrupt, then the Receive E1 Framer block will generate an interrupt in
response to either one of the following conditions.
1. The instant that the Receive E1 Framer block declares the AIS
condition.
2. The instant that the Receive E1 Framer block clears the AIS
condition.
0 – Disables the “Change in AIS Condition” Interrupt.
1 – Enables the “Change in AIS Condition” Interrupt.
0
RxYEL ENB
R/W
0
Change in Yellow alarm Condition interrupt enable
This bit permits the user to either enable or disable the “Change in Yellow
Alarm Condition” Interrupt, within the XRT86VL38 device. If the user
enables this interrupt, then the Receive E1 Framer block will generate an
interrupt in response to either one of the following conditions.
1. The instant that the Receive E1 Framer block declares the Yellow
Alarm condition.
2. The instant that the Receive E1 Framer block clears the Yellow
Alarm condition.
0 – Disables the “Change in Yellow Alarm Condition” Interrupt.
1 – Enables the “Change in Yellow Alarm Condition” Interrupt.
111
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
1
TABLE 99: FRAMER INTERRUPT STATUS REGISTER (FISR)
BIT
7
HEX ADDRESS: 0XnB04
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
COMFA Status
RUR/
WC
0
Change of CAS Multiframe Alignment Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the “Change of
CAS multiframe alignment” interrupt has occurred since the last read of
this register.
If this interrupt is enabled, then the Receive E1 Framer block will generate
an interrupt in response to either one of the following conditions.
1. Whenever the Receive E1 Framer block declares the “Loss of CAS
Multiframe Alignment”.
2. Whenever the Receive E1 Framer block clears the “Loss of CAS
Multiframe Alignment”
Loss CAS Multiframe Alignment is declared when the “CASC” number of
consecutive CAS Multiframe Alignment signals have been received in
error, where CASC sets the criteria for Loss of CAS multiframe. CASC can
ben programmed through Framing Control Register (FCR - address
0xn10B, bit 6-5)
0 = Indicates that the “Change of CAS Multiframe Alignment” interrupt has
not occurred since the last read of this register.
1 = Indicates that the “Change of CAS Multiframe Alignment” interrupt has
occurred since the last read of this register.
NOTES: This bit only has meaning when Channel Associated Signaling
(CAS) is enabled.
6
NBIT Status
RUR/
WC
0
Change in National Bits Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the “Change in
National Bits” interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt whenever any one of the National Bits (Sa4-Sa8)
within the incoming non-FAS E1 frames has changed.
0 = Indicates that the “Change in National Bits” interrupt has not occurred
since the last read of this register.
1 = Indicates that the “Change in National Bits” interrupt has occurred
since the last read of this register.
5
SIG Status
RUR/
WC
0
Change in CAS Signaling Bits Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the “Change in
CAS Signaling Bits” interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt whenever any one of the four signaling bits values
(A,B,C,D) has changed in any one of the 30 channels within the incoming
E1 frames. Users can read the signaling change registers (address
0xn10D-0xn110) to determine which signalling channel has changed.
0 = Indicates that the “Change in CAS Signaling Bits” interrupt has not
occurred since the last read of this register.
1 = Indicates that the “Change in CAS Signaling Bits” interrupt has
occurred since the last read of this register.
NOTE:
This bit only has meaning when Channel Associated Signaling
(CAS) is enabled.
112
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 99: FRAMER INTERRUPT STATUS REGISTER (FISR)
BIT
FUNCTION
TYPE
DEFAULT
REV. V1.2.1
HEX ADDRESS: 0XnB04
DESCRIPTION-OPERATION
4
COFA Status
RUR/
WC
0
Change of FAS Framing Alignment (COFA) Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the “Change of
FAS Framing Alignment” interrupt has occurred since the last read of this
register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt whenever the Receive E1 Framer block detects a
Change of FAS Framing Alignment Signal (e.g., the FAS bits have
appeared to move to a different location within the incoming E1 data
stream).
0 = Indicates that the “Change of FAS Framing Alignment (COFA)” interrupt has not occurred since the last read of this register.
1 = Indicates that the “Change of FAS Framing Alignment (COFA)” interrupt has occurred since the last read of this register.
3
LOF Status
RUR/
WC
0
Change in Loss of Frame Condition Interrupt Status.
This Reset-Upon-Read bit field indicates whether or not the “Change in
Receive Loss of Frame Condition” interrupt has occurred since the last
read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will generate
an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block declares the Loss of Frame
condition.
2. Whenever the Receive E1 Framer block clears the Loss of Frame
condition
0 = Indicates that the “Change in Receive Loss of Frame condition” interrupt has not occurred since the last read of this register
1 = Indicates that the “Change in Receive Loss of Frame condition” interrupt has occurred since the last read of this register
2
FMD Status
RUR/
WC
0
Frame Mimic Detection Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the “Frame Mimic
Detection” interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt whenever the Receive E1 Framer block detects the
presence of Frame Mimic bits (i.e., the Payload bits have appeared to
mimic the Framing pattern within the incoming E1 data stream).
0 = Indicates that the “Frame Mimic Detection” interrupt has not occurred
since the last read of this register.
1 = Indicates that the “Frame Mimic Detection” interrupt has occurred since
the last read of this register.
113
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 99: FRAMER INTERRUPT STATUS REGISTER (FISR)
BIT
FUNCTION
HEX ADDRESS: 0XnB04
TYPE
DEFAULT
DESCRIPTION-OPERATION
1
Sync Error Status
RUR/
WC
0
CRC-4 Error Interrupt Status.
This Reset-Upon-Read bit field indicates whether or not the “CRC-4 Error”
interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt whenever the Receive E1 Framer block detects a
CRC-4 Error within the incoming E1 sub-multiframe.
0 = Indicates that the “CRC-4 Error” interrupt has not occurred since the
last read of this register.
1 = Indicates that the “CRC-4 Error” interrupt has occurred since the last
read of this register.
0
Framing Error Status
RUR/
WC
0
Framing Error Interrupt Status
This Reset-Upon-Read bit field indicates whether or not a “Framing Error”
interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt whenever the Receive E1 Framer block detects one
or more Framing Alignment Bit Error within the incoming E1 data stream.
0 = Indicates that the “Framing Error” interrupt has not occurred since the
last read of this register.
1 = Indicates that the “Framing Error” interrupt has occurred since the last
read of this register.
NOTE: This bit doesn't not necessarily indicate that synchronization has
been lost.
114
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
1
TABLE 100: FRAMER INTERRUPT ENABLE REGISTER (FIER)
BIT
7
FUNCTION
COMFA ENB
HEX ADDRESS: 0XnB05
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Change in CAS Multiframe Alignment Interrupt Enable
This bit permits the user to either enable or disable the “Change in CAS
Multiframe Alignment” Interrupt, within the XRT86VL38 device. If the user
enables this interrupt, then the Receive E1 Framer block will generate an
interrupt in response to either one of the following conditions.
1. The instant that the Receive E1 Framer block declares the Loss of
CAS Multiframe Alignment condition.
2. The instant that the Receive E1 Framer block clears the Loss of
CAS Multiframe Alignment condition.
0 – Disables the “Change in CAS Multiframe Alignment” Interrupt.
1 – Enables the “Change in CAS Multiframe Alignment” Interrupt.
6
NBIT ENB
R/W
0
Change in National Bits Interrupt Enable
This bit permits the user to either enable or disable the “Change in
National Bits” Interrupt, within the XRT86VL38 device. If the user enables
this interrupt, then the Receive E1 Framer block will generate an interrupt
when it detects a change in the National Bits (Sa4-Sa8) within the channel.
0 = Disables the Change in National Bits Interrupt
1 - Enables the Change in National Bits Interrupt
5
SIG ENB
R/W
0
Change in CAS Signaling Bits Interrupt Enable
This bit permits the user to either enable or disable the “Change in CAS
Signaling Bits” Interrupt, within the XRT86VL38 device. If the user enables
this interrupt, then the Receive E1 Framer block will generate an interrupt
when it detects a change in the any four signaling bits (A,B,C,D) in any one
of the 30 signaling channels. Users can read the signaling change registers (address 0xn10D-0xn110) to determine which signalling channel has
changed state.
0 = Disables the Change in Signaling Bits Interrupt
1 - Enables the Change in Signaling Bits Interrupt
NOTE: This bit has no meaning when Channel Associated Signaling is
disabled.
4
COFA ENB
R/W
0
Change of FAS Framing Alignment (COFA) Interrupt Enable
This bit permits the user to either enable or disable the “Change in FAS
Framing Alignment (COFA)” Interrupt, within the XRT86VL38 device. If the
user enables this interrupt, then the Receive E1 Framer block will generate
an interrupt when it detects a Change of FAS Framing Alignment Signal
(e.g., the FAS bits have appeared to move to a different location within the
incoming E1 data stream).
0 – Disables the “Change of FAS Framing Alignment (COFA)” Interrupt.
1 – Enables the “Change of FAS Framing Alignment (COFA)” Interrupt.
115
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 100: FRAMER INTERRUPT ENABLE REGISTER (FIER)
BIT
3
FUNCTION
LOF ENB
HEX ADDRESS: 0XnB05
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Change in Loss of Frame Condition interrupt enable
This bit permits the user to either enable or disable the “Change in Loss of
Frame Condition” Interrupt, within the XRT86VL38 device. If the user
enables this interrupt, then the Receive E1 Framer block will generate an
interrupt in response to either one of the following conditions.
1. The instant that the Receive E1 Framer block declares the Loss of
Frame condition.
2. The instant that the Receive E1 Framer block clears the Loss of
Frame condition.
0 – Disables the “Change in Loss of Frame Condition” Interrupt.
1 – Enables the “Change in Loss of Frame Condition” Interrupt.
2
FMD ENB
R/W
0
Frame Mimic Detection Interrupt Enable
This bit permits the user to either enable or disable the “Frame Mimic
Detection” Interrupt, within the XRT86VL38 device. If the user enables this
interrupt, then the Receive E1 Framer block will generate an interrupt
when it detects the presence of Frame mimic bits (i.e., the payload bits
have appeared to mimic the framing bit pattern within the incoming E1
data stream).
0 – Disables the “Frame Mimic Detection” Interrupt.
1 – Enables the “Frame Mimic Detection” Interrupt.
1
SE_ENB
R/W
0
Synchronization Bit (CRC-4) Error Interrupt Enable
This bit permits the user to either enable or disable the “CRC-4 Error
Detection” Interrupt, within the XRT86VL38 device. If the user enables this
interrupt, then the Receive E1 Framer block will generate an interrupt
when it detects a CRC-4 error within the incoming E1 sub-multiframe.
0 – disable the “CRC-4 Error Detection” Interrupt.
1 – enable the “CRC-4 Error Detection” Interrupt.
0
FE_ENB
R/W
0
Framing Bit Error Interrupt Enable
This bit permits the user to either enable or disable the “Framing Alignment
Bit Error Detection” Interrupt, within the XRT86VL38 device. If the user
enables this interrupt, then the Receive E1 Framer block will generate an
interrupt when it detects one or more Framing Alignment Bit error within
the incoming E1 data stream.
0 – disable the “Framing Alignment Bit Error Detection” Interrupt.
1 – enable the “Framing Alignment Bit Error Detection” Interrupt.
NOTE:
Detecting Framing Alignment Bit Error doesn't not necessarily
indicate that synchronization has been lost.
116
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 101: DATA LINK STATUS REGISTER 1 (DLSR1)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0XnB06
TYPE
DEFAULT
DESCRIPTION-OPERATION
RO
0
HDLC1 Message Type Identifier
This READ ONLY bit indicates the type of data link message
received by Receive HDLC 1 Controller. Two types of data link messages are supported within the XRT86VL38 device: Message Oriented Signaling (MOS) or Bit-Oriented Signalling (BOS).
0 = Indicates Bit-Oriented Signaling (BOS) type data link message is
received
1 = Indicates Message Oriented Signaling (MOS) type data link
message is received
7
MSG TYPE
6
TxSOT
RUR/
WC
0
Transmit HDLC1 Controller Start of Transmission (TxSOT)
Interrupt Status
This Reset-Upon-Read bit indicates whether or not the “Transmit
HDLC1 Controller Start of Transmission (TxSOT) “Interrupt has
occurred since the last read of this register. Transmit HDLC1 Controller will declare this interrupt when it has started to transmit a data
link message. For sending large HDLC messages, start loading the
next available buffer once this interrupt is detected.
0 = Transmit HDLC1 Controller Start of Transmission (TxSOT) interrupt has not occurred since the last read of this register
1 = Transmit HDLC1 Controller Start of Transmission interrupt
(TxSOT) has occurred since the last read of this register.
5
RxSOT
RUR/
WC
0
Receive HDLC1 Controller Start of Reception (RxSOT) Interrupt
Status
This Reset-Upon-Read bit indicates whether or not the Receive
HDLC1 Controller Start of Reception (RxSOT) interrupt has
occurred since the last read of this register. Receive HDLC1 Controller will declare this interrupt when it has started to receive a data
link message.
0 = Receive HDLC1 Controller Start of Reception (RxSOT) interrupt
has not occurred since the last read of this register
1 = Receive HDLC1 Controller Start of Reception (RxSOT) interrupt
has occurred since the last read of this register
4
TxEOT
RUR/
WC
0
Transmit HDLC1 Controller End of Transmission (TxEOT) Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Transmit
HDLC1 Controller End of Transmission (TxEOT) Interrupt has
occurred since the last read of this register. Transmit HDLC1 Controller will declare this interrupt when it has completed its transmission of a data link message. For sending large HDLC messages, it
is critical to load the next available buffer before this interrupt
occurs.
0 = Transmit HDLC1 Controller End of Transmission (TxEOT) interrupt has not occurred since the last read of this register
1 = Transmit HDLC1 Controller End of Transmission (TxEOT) interrupt has occurred since the last read of this register
117
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 101: DATA LINK STATUS REGISTER 1 (DLSR1)
BIT
FUNCTION
HEX ADDRESS: 0XnB06
TYPE
DEFAULT
DESCRIPTION-OPERATION
3
RxEOT
RUR/
WC
0
Receive HDLC1 Controller End of Reception (RxEOT) Interrupt
Status
This Reset-Upon-Read bit indicates whether or not the Receive
HDLC1 Controller End of Reception (RxEOT) Interrupt has occurred
since the last read of this register. Receive HDLC1 Controller will
declare this interrupt once it has completely received a full data link
message, or once the buffer is full.
0 = Receive HDLC1 Controller End of Reception (RxEOT) interrupt
has not occurred since the last read of this register
1 = Receive HDLC1 Controller End of Reception (RxEOT) Interrupt
has occurred since the last read of this register
2
FCS Error
RUR/
WC
0
FCS Error Interrupt Status
This Reset-Upon-Read bit indicates whether or not the FCS Error
Interrupt has occurred since the last read of this register. Receive
HDLC1 Controller will declare this interrupt when it has detected the
FCS error in the most recently received data link message.
0 = FCS Error interrupt has not occurred since the last read of this
register
1 = FCS Error interrupt has occurred since the last read of this register
1
Rx ABORT
RUR/
WC
0
Receipt of Abort Sequence Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Receipt of
Abort Sequence interrupt has occurred since last read of this register. Receive HDLC1 Controller will declare this interrupt if it detects
the Abort Sequence (i.e. a string of seven (7) consecutive 1’s) in the
incoming data link channel.
0 = Receipt of Abort Sequence interrupt has not occurred since last
read of this register
1 = Receipt of Abort Sequence interrupt has occurred since last
read of this register
0
RxIDLE
RUR/
WC
0
Receipt of Idle Sequence Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Receipt of
Idle Sequence interrupt has occurred since the last read of this register. The Receive HDLC1 Controller will declare this interrupt if it
detects the flag sequence octet (0x7E) in the incoming data link
channel. If RxIDLE "AND" RxEOT occur together, then the entire
HDLC message has been received.
0 = Receipt of Idle Sequence interrupt has not occurred since last
read of this register
1 = Receipt of Idle Sequence interrupt has occurred since last read
of this register.
118
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 102: DATA LINK INTERRUPT ENABLE REGISTER 1 (DLIER1)
BIT
FUNCTION
TYPE
DEFAULT
-
-
Reserved
REV. V1.2.1
HEX ADDRESS: 0XnB07
DESCRIPTION-OPERATION
7
Reserved
6
TxSOT ENB
R/W
0
Transmit HDLC1 Controller Start of Transmission (TxSOT)
Interrupt Enable
This bit enables or disables the “Transmit HDLC1
Controller Start of Transmission (TxSOT) “Interrupt within the
XRT86VL38 device. Once this interrupt is enabled, the Transmit
HDLC1 Controller will generate an interrupt when it has started to
transmit a data link message.
0 = Disables the Transmit HDLC1 Controller Start of Transmission
(TxSOT) interrupt.
1 = Enables the Transmit HDLC1 Controller Start of Transmission
(TxSOT) interrupt.
5
RxSOT ENB
R/W
0
Receive HDLC1 Controller Start of Reception (RxSOT) Interrupt
Enable
This bit enables or disables the “Receive HDLC1
Controller Start of Reception (RxSOT) “Interrupt within the
XRT86VL38 device. Once this interrupt is enabled, the Receive
HDLC1 Controller will generate an interrupt when it has started to
receive a data link message.
0 = Disables the Receive HDLC1 Controller Start of Reception
(RxSOT) interrupt.
1 = Enables the Receive HDLC1 Controller Start of Reception
(RxSOT) interrupt.
4
TxEOT ENB
R/W
0
Transmit HDLC1 Controller End of Transmission (TxEOT) Interrupt Enable
This bit enables or disables the “Transmit HDLC1
Controller End of Transmission (TxEOT) “Interrupt within the
XRT86VL38 device. Once this interrupt is enabled, the Transmit
HDLC1 Controller will generate an interrupt when it has finished
transmitting a data link message.
0 = Disables the Transmit HDLC1 Controller End of Transmission
(TxEOT) interrupt.
1 = Enables the Transmit HDLC1 Controller End of Transmission
(TxEOT) interrupt.
3
RxEOT ENB
R/W
0
Receive HDLC1 Controller End of Reception (RxEOT) Interrupt
Enable
This bit enables or disables the “Receive HDLC1
Controller End of Reception (RxEOT) “Interrupt within the
XRT86VL38 device. Once this interrupt is enabled, the Receive
HDLC1 Controller will generate an interrupt when it has finished
receiving a complete data link message.
0 = Disables the Receive HDLC1 Controller End of Reception
(RxEOT) interrupt.
1 = Enables the Receive HDLC1 Controller End of Reception
(RxEOT) interrupt.
119
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 102: DATA LINK INTERRUPT ENABLE REGISTER 1 (DLIER1)
BIT
FUNCTION
TYPE
DEFAULT
HEX ADDRESS: 0XnB07
DESCRIPTION-OPERATION
2
FCS ERR ENB
R/W
0
FCS Error Interrupt Enable
This bit enables or disables the “Received FCS Error “Interrupt
within the XRT86VL38 device. Once this interrupt is enabled, the
Receive HDLC1 Controller will generate an interrupt when it has
detected the FCS error within the incoming data link message.
0 = Disables the “Receive FCS Error” interrupt.
1 = Enables the “Receive FCS Error” interrupt.
1
RxABORT ENB
R/W
0
Receipt of Abort Sequence Interrupt Enable
This bit enables or disables the “Receipt of Abort Sequence“ Interrupt within the XRT86VL38 device. Once this interrupt is enabled,
the Receive HDLC1 Controller will generate an interrupt when it has
detected the Abort Sequence (i.e. a string of seven (7) consecutive
1’s) within the incoming data link channel.
0 = Disables the “Receipt of Abort Sequence” interrupt.
1 = Enables the “Receipt of Abort Sequence” interrupt.
0
RxIDLE ENB
R/W
0
Receipt of Idle Sequence Interrupt Enable
This bit enables or disables the “Receipt of Idle Sequence“ Interrupt
within the XRT86VL38 device. Once this interrupt is enabled, the
Receive HDLC1 Controller will generate an interrupt when it has
detected the Idle Sequence Octet (i.e. 0x7E) within the incoming
data link channel.
0 = Disables the “Receipt of Idle Sequence” interrupt.
1 = Enables the “Receipt of Idle Sequence” interrupt.
120
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 103: SLIP BUFFER INTERRUPT STATUS REGISTER (SBISR)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0XnB08
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
TxSB_FULL
RUR/
WC
0
Transmit Slip buffer Full Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Transmit Slip
Buffer Full interrupt has occurred since the last read of this register. The
transmit Slip Buffer Full interrupt is declared when the transmit slip buffer
is filled. If the transmit slip buffer is full and a WRITE operation occurs,
then a full frame of data will be deleted, and this interrupt bit will be set to
‘1’.
0 = Indicates that the Transmit Slip Buffer Full interrupt has not occurred
since the last read of this register.
1 = Indicates that the Transmit Slip Buffer Full interrupt has occurred since
the last read of this register.
6
TxSB_EMPT
RUR/
WC
0
Transmit Slip buffer Empty Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Transmit Slip
Buffer Empty interrupt has occurred since the last read of this register. The
transmit Slip Buffer Empty interrupt is declared when the transmit slip
buffer is emptied. If the transmit slip buffer is emptied and a READ operation occurs, then a full frame of data will be repeated, and this interrupt bit
will be set to ‘1’.
0 = Indicates that the Transmit Slip Buffer Empty interrupt has not
occurred since the last read of this register.
1 = Indicates that the Transmit Slip Buffer Empty interrupt has occurred
since the last read of this register.
5
TxSB_SLIP
RUR/
WC
0
Transmit Slip Buffer Slips Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Transmit Slip
Buffer Slips interrupt has occurred since the last read of this register. The
transmit Slip Buffer Slips interrupt is declared when the transmit slip buffer
is either filled or emptied. This interrupt bit will be set to ‘1’ in either one of
these two conditions:
1. If the transmit slip buffer is emptied and a READ operation occurs,
then a full frame of data will be repeated, and this interrupt bit will be
set to ‘1’.
2. If the transmit slip buffer is full and a WRITE operation occurs, then
a full frame of data will be deleted, and this interrupt bit will be set to
‘1’.
0 = Indicates that the Transmit Slip Buffer Slips interrupt has not occurred
since the last read of this register.
1 = Indicates that the Transmit Slip Buffer Slips interrupt has occurred
since the last read of this register.
NOTE: Users still need to read the Transmit Slip Buffer Empty Interrupt (bit
6 of this register) or the Transmit Slip Buffer Full Interrupts (bit 7 of
this register) to determine whether transmit slip buffer empties or
fills.
121
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 103: SLIP BUFFER INTERRUPT STATUS REGISTER (SBISR)
BIT
4
FUNCTION
CAS SYNC
TYPE
DEFAULT
DESCRIPTION-OPERATION
RO
0
CAS Multiframe Alignment is in SYNC
This READ ONLY bit field indicates whether or not the E1 Receive Framer
Block is declaring CAS Multiframe Alignment LOCK status.
The E1 Receive Framer Block will declare the CAS Multiframe Alignment
LOCK status according to the CAS Multiframe Alignment Algorithm as
described in the Framing Select Register (FSR - address 0xn107).
The E1 Receive Framer Block will declare the CAS Multiframe Alignment
LOSS OF LOCK status when CASC number of consecutive CAS Multiframe Alignment Signals have been received in error, where CASC sets
the Loss of CAS Multiframe Alignment Criteria, as described in the Framing Control Register (FCR - address 0xn10B).
0 = Indicates that the E1 Receive Framer Block is currently declaring CAS
Multiframe LOSS OF LOCK status
1 = Indicates that the E1 Receive Framer Block is currently declaring CAS
Multiframe LOCK status
NOTE:
3
CRCMLOCK
HEX ADDRESS: 0XnB08
RO
0
In E1 mode, this bit has no meaning if Channel Associated
Signaling is disabled.
CRC Multiframe is in SYNC
This READ ONLY bit field indicates whether or not the E1 Receive Framer
Block is declaring the E1 CRC Multiframe Alignment LOCK status.
The E1 Receive Framer declares the CRC Multiframe Alignment LOCK
status according to the CRC Multiframe Alignment Declaration Criteria
which can be selected in the Framing Select Register (FSR - address
0xn107)
The E1 Receive Framer declares the CRC Multiframe Alignment LOSS
OF LOCK status according to the Loss CRC Multiframe Alignment Criteria
selected in the Framing Control Register (FCR - address 0xn10B)
0 = Indicates that the E1 Receive Framer is currently declaring E1 CRC
Multiframe Alignment LOSS OF LOCK status
0 = Indicates that the E1 Receive Framer is currently declaring E1 Multiframe Alignment LOCK status
NOTE: In E1 mode, this bit has no meaning if CRC Multiframe Alignment
is disabled.
2
RxSB_FULL
RUR/
WC
0
Receive Slip buffer Full Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Receive Slip Buffer
Full interrupt has occurred since the last read of this register. The Receive
Slip Buffer Full interrupt is declared when the receive slip buffer is filled. If
the receive slip buffer is full and a WRITE operation occurs, then a full
frame of data will be deleted, and this interrupt bit will be set to ‘1’.
0 = Indicates that the Receive Slip Buffer Full interrupt has not occurred
since the last read of this register.
1 = Indicates that the Receive Slip Buffer Full interrupt has occurred since
the last read of this register.
122
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 103: SLIP BUFFER INTERRUPT STATUS REGISTER (SBISR)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0XnB08
TYPE
DEFAULT
DESCRIPTION-OPERATION
1
RxSB_EMPT
RUR/
WC
0
Receive Slip buffer Empty Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Receive Slip Buffer
Empty interrupt has occurred since the last read of this register. The
Receive Slip Buffer Empty interrupt is declared when the receive slip
buffer is emptied. If the receive slip buffer is emptied and a READ operation occurs, then a full frame of data will be repeated, and this interrupt bit
will be set to ‘1’.
0 = Indicates that the Receive Slip Buffer Empty interrupt has not occurred
since the last read of this register.
1 = Indicates that the Receive Slip Buffer Empty interrupt has occurred
since the last read of this register.
0
RxSB_SLIP
RUR/
WC
0
Receive Slip Buffer Slips Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Receive Slip Buffer
Slips interrupt has occurred since the last read of this register. The
Receive Slip Buffer Slips interrupt is declared when the receive slip buffer
is either filled or emptied. This interrupt bit will be set to ‘1’ in either one of
these two conditions:
1. If the receive slip buffer is emptied and a READ operation occurs,
then a full frame of data will be repeated, and this interrupt bit will be
set to ‘1’.
2. If the receive slip buffer is full and a WRITE operation occurs, then a
full frame of data will be deleted, and this interrupt bit will be set to
‘1’.
0 = Indicates that the Receive Slip Buffer Slips interrupt has not occurred
since the last read of this register.
1 = Indicates that the Receive Slip Buffer Slips interrupt has occurred
since the last read of this register.
NOTE: Users still need to read the Receive Slip Buffer Empty Interrupt (bit
1 of this register) or the Receive Slip Buffer Full Interrupts (bit 2 of
this register) to determine whether transmit slip buffer empties or
fills.
123
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 104: SLIP BUFFER INTERRUPT ENABLE REGISTER (SBIER)
BIT
FUNCTION
HEX ADDRESS: 0XnB09
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
TxFULL_ENB
R/W
0
Transmit Slip Buffer Full Interrupt Enable
This bit enables or disables the Transmit Slip Buffer Full interrupt
within the XRT86VL38 device. Once this interrupt is enabled, the
transmit Slip Buffer Full interrupt is declared when the transmit slip
buffer is filled. If the transmit slip buffer is full and a WRITE operation occurs, then a full frame of data will be deleted, and the interrupt
status bit will be set to ‘1’.
0 = Disables the Transmit Slip Buffer Full interrupt when the Transmit Slip Buffer fills
1 - Enables the Transmit Slip Buffer Full interrupt when the Transmit
Slip Buffer fills.
6
TxEMPT_ENB
R/W
0
Transmit Slip Buffer Empty Interrupt Enable
This bit enables or disables the Transmit Slip Buffer Empty interrupt
within the XRT86VL38 device. Once this interrupt is enabled, the
transmit Slip Buffer Empty interrupt is declared when the transmit
slip buffer is emptied. If the transmit slip buffer is emptied and a
READ operation occurs, then a full frame of data will be repeated,
and the interrupt status bit will be set to ‘1’.
0 = Disables the Transmit Slip Buffer Empty interrupt when the
Transmit Slip Buffer empties
1 - Enables the Transmit Slip Buffer Empty interrupt when the Transmit Slip Buffer empties.
5
TxSLIP_ENB
R/W
0
Transmit Slip Buffer Slips Interrupt Enable
This bit enables or disables the Transmit Slip Buffer Slips interrupt
within the XRT86VL38 device. Once this interrupt is enabled, the
transmit Slip Buffer Slips interrupt is declared when either the transmit slip buffer is filled or emptied. If the transmit slip buffer is emptied
and a READ operation occurs, then a full frame of data will be
repeated, and the interrupt status bit will be set to ‘1’.
The interrupt status bit will be set to ‘1’ in either one of these two
conditions:
1. If the transmit slip buffer is emptied and a READ operation
occurs, then a full frame of data will be repeated, and this
interrupt bit will be set to ‘1’.
2. If the transmit slip buffer is full and a WRITE operation occurs,
then a full frame of data will be deleted, and this interrupt bit
will be set to ‘1’.
0 = Disables the Transmit Slip Buffer Slips interrupt when the Transmit Slip Buffer empties or fills
1 - Enables the Transmit Slip Buffer Slips interrupt when the Transmit Slip Buffer empties or fills.
4-3 Reserved
-
-
Reserved
124
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 104: SLIP BUFFER INTERRUPT ENABLE REGISTER (SBIER)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0XnB09
TYPE
DEFAULT
DESCRIPTION-OPERATION
2
RxFULL_ENB
R/W
0
Receive Slip Buffer Full Interrupt Enable
This bit enables or disables the Receive Slip Buffer Full interrupt
within the XRT86VL38 device. Once this interrupt is enabled, the
Receive Slip Buffer Full interrupt is declared when the receive slip
buffer is filled. If the Receive slip buffer is full and a WRITE operation occurs, then a full frame of data will be deleted, and the interrupt
status bit will be set to ‘1’.
0 = Disables the Receive Slip Buffer Full interrupt when the Transmit
Slip Buffer fills
1 - Enables the Receive Slip Buffer Full interrupt when the Transmit
Slip Buffer fills.
1
RxEMPT_ENB
R/W
0
Receive Slip buffer Empty Interrupt Enable
This bit enables or disables the Receives Slip Buffer Empty interrupt
within the XRT86VL38 device. Once this interrupt is enabled, the
Receive Slip Buffer Empty interrupt is declared when the Receive
slip buffer is emptied. If the Receive slip buffer is emptied and a
READ operation occurs, then a full frame of data will be repeated,
and the interrupt status bit will be set to ‘1’.
0 = Disables the Receive Slip Buffer Empty interrupt when the
Transmit Slip Buffer empties
1 - Enables the Receive Slip Buffer Empty interrupt when the Transmit Slip Buffer empties.
0
RxSLIP_ENB
R/W
0
Receive Slip buffer Slips Interrupt Enable
This bit enables or disables the Receive Slip Buffer Slips interrupt
within the XRT86VL38 device. Once this interrupt is enabled, the
Receive Slip Buffer Slips interrupt is declared when either the
Receive slip buffer is filled or emptied. If the Receive slip buffer is
emptied and a READ operation occurs, then a full frame of data will
be repeated, and the interrupt status bit will be set to ‘1’.
The interrupt status bit will be set to ‘1’ in either one of these two
conditions:
1. If the Receive slip buffer is emptied and a READ operation
occurs, then a full frame of data will be repeated, and this
interrupt bit will be set to ‘1’.
2. If the Receive slip buffer is full and a WRITE operation occurs,
then a full frame of data will be deleted, and this interrupt bit
will be set to ‘1’.
0 = Disables the Receive Slip Buffer Slips interrupt when the Transmit Slip Buffer empties or fills
1 - Enables the Receive Slip Buffer Slips interrupt when the Transmit Slip Buffer empties or fills.
125
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 105: RECEIVE LOOPBACK CODE INTERRUPT AND STATUS REGISTER (RLCISR)
BIT
FUNCTION
TYPE
DEFAULT
HEX ADDRESS: 0XnB0A
DESCRIPTION-OPERATION
7
AUXPSTAT
RO
0
AUXP state
This READ ONLY bit indicates whether or not the Receive E1
Framer Block is currently detecting Auxiliary (101010....) pattern.
0 = Indicates that the Receive E1 Framer Block is NOT currently
detecting the Auxiliary (101010....)Pattern.
1 = Indicates that the Receive E1 Framer Block is currently detecting the Auxiliary (101010....)Pattern.
6
AUXPINT
RUR/WC
0
Change in Auxiliary Pattern interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Auxiliary Pattern” interrupt has occurred since the last
read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the Auxiliary
Pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Auxiliary Pattern
0 = Indicates that the “Change in Auxiliary Pattern” interrupt has not
occurred since the last read of this register
1 = Indicates that the “Change in Auxiliary Pattern” interrupt has
occurred since the last read of this register
5
NONCRCSTAT
RO
0
CRC-4-to-non-CRC-4 interworking state
This READ ONLY bit indicates the status of CRC-4 interworking status when Annex B is enabled. (MODENB bit in register 0xn107)
When Annex B is enabled, G.706 Annex B CRC-4 multiframe alignment algorithm is implemented. If CRC-4 alignment is enabled and
not achieved in 400msec while the basic frame alignment signal is
present, it is assumed that the remote end is a non CRC-4 equipment. Then, a CRC-to-Non-CRC interworking interrupt status will be
generated.
0 = Indicates CRC-4 to non-CRC-4 interworking is NOT established.
1 = Indicates CRC-4 to non-CRC-4 interworking is established.
126
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 105: RECEIVE LOOPBACK CODE INTERRUPT AND STATUS REGISTER (RLCISR)
BIT
4
FUNCTION
NONCRCINT
TYPE
RUR/WC
REV. V1.2.1
HEX ADDRESS: 0XnB0A
DEFAULT
DESCRIPTION-OPERATION
0
Change of CRC-4-to-non-CRC-4 interworking interrupt Status This Reset-Upon-Read bit field indicates whether or not the
“Change in CRC-4 to Non-CRC-4 interworking” interrupt has
occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the CRC-4 to
non-CRC-4 interworking condition.
2. Whenever the Receive E1 Framer block detects the nonCRC-4 to CRC-4 interworking condition.
0 = Indicates that the “Change in CRC-4 to non-CRC-4 interworking”
interrupt has not occurred since the last read of this register
1 = Indicates that the “Change in CRC-4 to non-CRC-4 interworking”
interrupt has occurred since the last read of this register
3-0
For T1 mode only
127
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 106: RECEIVE LOOPBACK CODE INTERRUPT ENABLE REGISTER (RLCIER)
BIT
6
FUNCTION
AUXPINTENB
HEX ADDRESS: 0XnB0B
TYPE
DEFAULT
DESCRIPTION-OPERATION
R/W
0
Change in Auxiliary Pattern interrupt enable
This READ WRITE bit field enables or disables the “Change in Auxiliary Pattern” interrupt within the E1 Receive Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the Auxiliary
Pattern.
2. Whenever the Receive E1 Framer block no longer detects
the Auxiliary Pattern
0 = Disables the “Change in Auxiliary Pattern” interrupt within the
E1 Receive Framer.
1 - Enables the “Change in Auxiliary Pattern” interrupt within the E1
Receive Framer.
5
Reserved
4
NONCRCENB
-
-
Reserved
R/W
0
Change of CRC-4-to-non-CRC-4 interworking interrupt Enable
This bit enables or disables the “Change in CRC-4 to Non-CRC-4
interworking” interrupt within the E1 Receive Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the CRC-4
to non-CRC-4 interworking condition.
2. Whenever the Receive E1 Framer block detects the nonCRC-4 to CRC-4 interworking condition.
0 = Disables the “Change in CRC-4 to non-CRC-4 interworking”
interrupt within the E1 Receive Framer.
1 - Enables the “Change in CRC-4 to non-CRC-4 interworking”
interrupt within the E1 Receive Framer.
3-2 Reserved
1-0 Reserved
-
-
Reserved
For T1 mode only
128
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 107: RECEIVE SA INTERRUPT STATUS REGISTER (RSAISR)
BIT
7
FUNCTION
SA6_1111
REV. V1.2.1
HEX ADDRESS: 0XnB0C
TYPE
DEFAULT
DESCRIPTION-OPERATION
RUR/
WC
0
Change in Debounced Sa6 = 1111 Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Debounced Sa6=1111” interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1111 pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1111 pattern.
0 = Indicates that the “Change in Debounced Sa6=1111” interrupt
has not occurred since the last read of this register
1 = Indicates that the “Change in Debounced Sa6=1111” interrupt
has occurred since the last read of this register
6
SA6_1110
RUR/
WC
0
Change in Debounced Sa6 = 1110 Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Debounced Sa6=1110” interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1110 pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1110 pattern.
0 = Indicates that the “Change in Debounced Sa6=1110” interrupt
has not occurred since the last read of this register
1 = Indicates that the “Change in Debounced Sa6=1110” interrupt
has occurred since the last read of this register
5
SA6_1100
RUR/
WC
0
Change in Debounced Sa6 = 1100 Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Debounced Sa6=1100” interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1100 pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1100 pattern.
0 = Indicates that the “Change in Debounced Sa6=1100” interrupt
has not occurred since the last read of this register
1 = Indicates that the “Change in Debounced Sa6=1100” interrupt
has occurred since the last read of this register
129
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 107: RECEIVE SA INTERRUPT STATUS REGISTER (RSAISR)
BIT
4
FUNCTION
SA6_1010
HEX ADDRESS: 0XnB0C
TYPE
DEFAULT
DESCRIPTION-OPERATION
RUR/
WC
0
Change in Debounced Sa6 = 1010 Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Debounced Sa6=1010” interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1010 pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1010 pattern.
0 = Indicates that the “Change in Debounced Sa6=1010” interrupt
has not occurred since the last read of this register
1 = Indicates that the “Change in Debounced Sa6=1010” interrupt
has occurred since the last read of this register
3
SA6_1000
RUR/
WC
0
Change in Debounced Sa6 = 1000 Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Debounced Sa6=1000” interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1000 pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1000 pattern.
0 = Indicates that the “Change in Debounced Sa6=1000” interrupt
has not occurred since the last read of this register
1 = Indicates that the “Change in Debounced Sa6=1000” interrupt
has occurred since the last read of this register
2
SA6_001x
RUR/
WC
0
Change in Debounced Sa6 = 001x Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Debounced Sa6=001x” interrupt has occurred since the
last read of this register, where x is don’t care.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 001x pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 001x pattern.
0 = Indicates that the “Change in Debounced Sa6=001x” interrupt
has not occurred since the last read of this register
1 = Indicates that the “Change in Debounced Sa6=001x” interrupt
has occurred since the last read of this register
130
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 107: RECEIVE SA INTERRUPT STATUS REGISTER (RSAISR)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0XnB0C
TYPE
DEFAULT
DESCRIPTION-OPERATION
1
SA6_other
RUR/
WC
0
Debounced Sa6 = other Combination Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Debounced Sa6=other combination” interrupt has
occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt when it detects the Debounced Sa 6 equals to
any other combinations.
0 = Indicates that the “Debounced Sa6 = other combination” interrupt has not occurred since the last read of this register
1 = Indicates that the “Debounced Sa6 = other combination” interrupt has occurred since the last read of this register
0
SA6_0000
RUR/
WC
0
Change in Debounced Sa6 = 0000 Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Debounced Sa6=0000” interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 0000 pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 0000 pattern.
0 = Indicates that the “Change in Debounced Sa6=0000” interrupt
has not occurred since the last read of this register
1 = Indicates that the “Change in Debounced Sa6=0000” interrupt
has occurred since the last read of this register
131
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 108: RECEIVE SA INTERRUPT ENABLE REGISTER (RSAIER)
BIT
7
FUNCTION
SA6_1111_ENB
TYPE
DEFAULT
R/W
0
HEX ADDRESS: 0XnB0D
DESCRIPTION-OPERATION
Change in Debounced Sa6 = 1111 Interrupt Enable
This bit enables or disables the “Change in Debounced Sa6=1111”
interrupt within the E1 Receive Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1111 pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1111 pattern.
0 = Disables the “Change in Debounced Sa6=1111” interrupt within
the Receive E1 Framer Block
1 - Enables the “Change in Debounced Sa6=1111” interrupt within
the Receive E1 Framer Block
6
SA6_1110_ENB
R/W
0
Change in Debounced Sa6 = 1110 Interrupt Enable
This bit enables or disables the “Change in Debounced Sa6=1110”
interrupt within the E1 Receive Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1110 pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1110 pattern.
0 = Disables the “Change in Debounced Sa6=1110” interrupt within
the Receive E1 Framer Block
1 - Enables the “Change in Debounced Sa6=1110” interrupt within
the Receive E1 Framer Block
5
SA6_1100_ENB
R/W
0
Change in Debounced Sa6 = 1100 Interrupt Enable
This bit enables or disables the “Change in Debounced Sa6=1100”
interrupt within the E1 Receive Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1100 pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1100 pattern.
0 = Disables the “Change in Debounced Sa6=1100” interrupt within
the Receive E1 Framer Block
1 - Enables the “Change in Debounced Sa6=1100” interrupt within
the Receive E1 Framer Block
132
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 108: RECEIVE SA INTERRUPT ENABLE REGISTER (RSAIER)
BIT
4
REV. V1.2.1
HEX ADDRESS: 0XnB0D
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
SA6_1010_ENB
R/W
0
Change in Debounced Sa6 = 1010 Interrupt Enable
This bit enables or disables the “Change in Debounced Sa6=1010”
interrupt within the E1 Receive Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1010 pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1010 pattern.
0 = Disables the “Change in Debounced Sa6=1010” interrupt within
the Receive E1 Framer Block
1 - Enables the “Change in Debounced Sa6=1010” interrupt within
the Receive E1 Framer Block
3
SA6_1000_ENB
R/W
0
Change in Debounced Sa6 = 1000 Interrupt Enable
This bit enables or disables the “Change in Debounced Sa6=1000”
interrupt within the E1 Receive Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1000 pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1000 pattern.
0 = Disables the “Change in Debounced Sa6=1000” interrupt within
the Receive E1 Framer Block
1 - Enables the “Change in Debounced Sa6=1000” interrupt within
the Receive E1 Framer Block
2
SA6_001x_ENB
R/W
0
Change in Debounced Sa6 = 001x Interrupt Enable
This bit enables or disables the “Change in Debounced Sa6=001x”
interrupt within the E1 Receive Framer, where x is don’t care.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 001x pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 001x pattern.
0 = Disables the “Change in Debounced Sa6=001x” interrupt within
the Receive E1 Framer Block
1 - Enables the “Change in Debounced Sa6=001x” interrupt within
the Receive E1 Framer Block
133
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 108: RECEIVE SA INTERRUPT ENABLE REGISTER (RSAIER)
BIT
HEX ADDRESS: 0XnB0D
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
1
SA6_other_ENB
R/W
0
Debounced Sa6 = Other Combination Interrupt enable
This bit enables or disables the “Debounced Sa6=other combination” interrupt within the E1 Receive Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt when it detects the debounced Sa6 equals to
any other combination.
0 = Disables the “Debounced Sa6=other combination” interrupt
within the Receive E1 Framer Block
1 - Enables the “Debounced Sa6=other combination” interrupt within
the Receive E1 Framer Block
0
SA6_0000_ENB
R/W
0
Change in Debounced Sa6 = 0000 Interrupt Enable
This bit enables or disables the “Change in Debounced Sa6=0000”
interrupt within the E1 Receive Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 0000 pattern.
2. Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 0000 pattern.
0 = Disables the “Change in Debounced Sa6=0000” interrupt within
the Receive E1 Framer Block
1 - Enables the “Change in Debounced Sa6=0000” interrupt within
the Receive E1 Framer Block
134
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 109: EXCESSIVE ZERO STATUS REGISTER (EXZSR)
BIT
5
FUNCTION
SA7_EQ_0_STAT
4-2 Reserved
1
SA7_EQ_0_INT
REV. V1.2.1
HEX ADDRESS: 0XnB0E
TYPE
DEFAULT
DESCRIPTION-OPERATION
RO
0
Received Sa7 Equals ‘0’ State
This READ ONLY bit field indicates whether or not the Receive E1
Framer is currently declaring the “Sa7 Equals 0” status within the
incoming E1 National Bits.
The “Received Sa7 Equals 0” status will be set to ‘1’ if the received
Sa7 is 0 for at least 2 out of 3 times.
0 = Indicates the E1 Receive Framer is currently not declaring the
“Received Sa7 Equals 0” status.
1 = Indicates the E1 Receive Framer is currently declaring the
“Received Sa7 Equals 0” status.
-
-
Reserved
RUR/
WC
0
Change in “Sa 7 Equals 0” Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Sa7 Equals 0” interrupt has occurred since the last read
of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the Received
Sa7 equals to 0 for at least 2 out of 3 times.
2. Whenever the Receive E1 Framer block no longer detects the
Received Sa7 equals to the 0.
0 = Indicates that the “Change in Sa7 Equals 0” interrupt has not
occurred since the last read of this register
1 = Indicates that the “Change in Sa7 Equals 0” interrupt has
occurred since the last read of this register
0
EXZ_STATUS
RUR/
WC
0
Change in Excessive Zero Condition Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Excessive Zero Condition” interrupt within the E1
Receive Framer Block has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Excessive Zero Condition.
2. Whenever the Receive E1 Framer block clears the Excessive
Zero Condition
0 = Indicates the “Change in Excessive Zero Condition” interrupt
has NOT occurred since the last read of this register
1 = Indicates the “Change in Excessive Zero Condition” interrupt
has occurred since the last read of this register
135
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 110: EXCESSIVE ZERO ENABLE REGISTER (EXZER)
BIT
1
HEX ADDRESS: 0XnB0F
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
SA7_EQ_0_ENB
R/W
0
Change in “Sa 7 Equals 0” Interrupt Enable
This bit enables or disables the “Change in Sa7 Equals 0” interrupt
within the Receive E1 Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the Received
Sa7 equals to 0 for at least 2 out of 3 times.
2. Whenever the Receive E1 Framer block no longer detects the
Received Sa7 equals to the 0.
0 = Disables the “Change in Sa7 Equals 0” interrupt within the E1
Receive Framer Block.
1 = Enables the “Change in Sa7 Equals 0” interrupt within the E1
Receive Framer Block.
0
EXZ_ENB
R/W
0
Change in Excessive Zero Condition Interrupt Enable
This bit enables or disables the “Change in Excessive Zero Condition” interrupt within the E1 Receive Framer.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block detects the
Excessive Zero Condition.
2. Whenever the Receive E1 Framer block clears the Excessive
Zero Condition
0 = Disables the “Change in Excessive Zero Condition” interrupt
within the Receive E1 Framer Block
1 - Enables the “Change in Excessive Zero Condition” interrupt
within the Receive E1 Framer Block
TABLE 111: SS7 STATUS REGISTER FOR LAPD1 (SS7SR1)
BIT
0
HEX ADDRESS: 0XnB10
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
SS7_1_STATUS
RUR/
WC
0
SS7 Interrupt Status for LAPD Controller 1
This Reset-Upon-Read bit field indicates whether or not the “SS7”
interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt when the Received LAPD message is more
than 276 Bytes in length.
0 = Indicates that the “SS7” interrupt has not occurred since the last
read of this register
1 = Indicates that the “SS7” interrupt has occurred since the last
read of this register
136
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 112: SS7 ENABLE REGISTER FOR LAPD1 (SS7ER1)
BIT
0
FUNCTION
SS7_1_ENB
TYPE
DEFAULT
R/W
0
FUNCTION
4
AIS16
3
RxLOSINT
HEX ADDRESS: 0XnB11
DESCRIPTION-OPERATION
SS7 Interrupt Enable for LAPD Controller 1
This bit enables or disables the “SS7” interrupt within the LAPD
Controller 1.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt when the Received LAPD message is more
than 276 Bytes in length.
0 - Disables the “SS7” interrupt within the LAPD Controller 1.
1 - Enables the “SS7” interrupt within the LAPD Controller 1.
TABLE 113: RXLOS/CRC INTERRUPT STATUS REGISTER (RLCISR)
BIT
REV. V1.2.1
HEX ADDRESS: 0XNB12
TYPE
DEFAULT
DESCRIPTION-OPERATION
RO
0
AIS 16 State
This bit indicates whether or not the Receive E1 Framer is declaring
AIS 16 (Time slot 16 = All Ones Signal) alarm condition.
0 - Indicates the Receive E1 Framer is currently NOT declaring the
AIS16 alarm condition.
1 - Indicates the Receive E1 Framer is currently declaring the AIS16
alarm condition.
RUR/
WC
0
Change in Receive LOS condition Interrupt Status
This bit indicates whether or not the “Change in Receive LOS condition” interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block declares the Receive
LOS condition.
2. Whenever the Receive E1 Framer block clears the Receive
LOS condition.
0 = Indicates that the “Change in Receive LOS Condition” interrupt
has not occurred since the last read of this register.
1 = Indicates that the “Change in Receive LOS Condition” interrupt
has occurred since the last read of this register.
137
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 113: RXLOS/CRC INTERRUPT STATUS REGISTER (RLCISR)
BIT
2
FUNCTION
CRCLOCK_INT
HEX ADDRESS: 0XNB12
TYPE
DEFAULT
DESCRIPTION-OPERATION
RUR/
WC
0
Change in CRC Multiframe Alignment In-Frame Interrupt Status
This bit indicates whether or not the E1 Receive Framer block has
lost or gained CRC Multiframe Alignment since the last read of this
register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block declares CRC
Multiframe Alignment LOCK.
2. Whenever the Receive E1 Framer block declares Loss of
CRC Multiframe Alignment.
0 = Indicates that the “Change in CRC Multiframe Alignment InFrame” interrupt has not occurred since the last read of this register.
1 = Indicates that the “Change in CRC Multiframe Alignment InFrame” interrupt has occurred since the last read of this register.
1
CASLOCK_INT
RUR/
WC
0
Change in CAS Multiframe Alignment In-Frame Interrupt Status
This bit indicates whether or not the E1 Receive Framer block has
lost or gained CAS Multiframe Alignments since the last read of this
register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block declares CAS
Multiframe Alignment LOCK.
2. Whenever the Receive E1 Framer block declares Loss of
CAS Multiframe Alignment.
0 = Indicates that the “Change in CAS Multiframe Alignment InFrame” interrupt has not occurred since the last read of this register.
1 = Indicates that the “Change in CAS Multiframe Alignment InFrame” interrupt has occurred since the last read of this register.
0
AIS16_INT
RUR/
WC
0
Change in AIS16 Alarm Condition Interrupt Status
This bit indicates whether or not the “Change in AIS16 Alarm Condition” interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1. Whenever the Receive E1 Framer block declares AIS16
(TimeSlot 16 = All Ones) condition.
2. Whenever the Receive E1 Framer block clears AIS16
(TimeSlot 16 = All Ones) condition.
0 = Indicates that the “Change in AIS16 Condition” interrupt has not
occurred since the last read of this register.
1 = Indicates that the “Change in AIS16 Condition” interrupt has
occurred since the last read of this register.
138
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 114: RXLOS/CRC INTERRUPT ENABLE REGISTER (RLCIER)
BIT
FUNCTION
TYPE
DEFAULT
REV. V1.2.1
HEX ADDRESS: 0XNB13
DESCRIPTION-OPERATION
3
RxLOS_ENB
R/W
0
Change in Receive LOS Condition Interrupt Enable
This bit enables the “Change in Receive LOS Condition” interrupt.
0 = Enables “Change in Receive LOS Condition” Interrupt.
1 = Disables “Change in Receive LOS Condition” Interrupt.
2
CRCLOCK_ENB
R/W
0
Change in CRC Multiframe Alignment In-Frame Interrupt Enable
This bit enables the “Change in CRC Multiframe Alignment In-Frame”
interrupt.
0 = Enables “Change in CRC Multiframe Alignment In-Frame” Interrupt.
1 = Disables “Change in CRC Multiframe Alignment In-Frame” Interrupt.
1
CASLOCK_ENB
R/W
0
Change in CAS Multiframe Alignment In-Frame Interrupt Enable
This bit enables the “Change in CAS Multiframe Alignment In-Frame”
interrupt.
0 = Enables “Change in CAS Multiframe Alignment In-Frame” Interrupt.
1 = Disables “Change in CAS Multiframe Alignment In-Frame” Interrupt.
0
AIS16_ENB
R/W
0
Change in AIS16 Condition Interrupt Enable
This bit enables the “Change in AIS16 (Time Slot 16 = All Ones) Condition” interrupt.
0 = Enables “Change in AIS 16 Condition” Interrupt.
1 = Disables “Change in AIS 16 Condition” Interrupt.
139
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 115: DATA LINK STATUS REGISTER 2 (DLSR2)
BIT
FUNCTION
HEX ADDRESS: 0XnB16
TYPE
DEFAULT
DESCRIPTION-OPERATION
RO
0
HDLC2 Message Type Identifier
This READ ONLY bit indicates the type of data link message
received by Receive HDLC 2 Controller. Two types of data link messages are supported within the XRT86VL38 device: Message Oriented Signaling (MOS) or Bit-Oriented Signalling (BOS).
0 = Indicates Bit-Oriented Signaling (BOS) type data link message is
received
1 = Indicates Message Oriented Signaling (MOS) type data link
message is received
7
MSG TYPE
6
TxSOT
RUR/
WC
0
Transmit HDLC2 Controller Start of Transmission (TxSOT)
Interrupt Status
This Reset-Upon-Read bit indicates whether or not the “Transmit
HDLC2 Controller Start of Transmission (TxSOT) “Interrupt has
occurred since the last read of this register. Transmit HDLC2 Controller will declare this interrupt when it has started to transmit a data
link message. For sending large HDLC messages, start loading the
next available buffer once this interrupt is detected.
0 = Transmit HDLC2 Controller Start of Transmission (TxSOT) interrupt has not occurred since the last read of this register
1 = Transmit HDLC2 Controller Start of Transmission interrupt
(TxSOT) has occurred since the last read of this register.
5
RxSOT
RUR/
WC
0
Receive HDLC2 Controller Start of Reception (RxSOT) Interrupt
Status
This Reset-Upon-Read bit indicates whether or not the Receive
HDLC2 Controller Start of Reception (RxSOT) interrupt has
occurred since the last read of this register. Receive HDLC2 Controller will declare this interrupt when it has started to receive a data
link message.
0 = Receive HDLC2 Controller Start of Reception (RxSOT) interrupt
has not occurred since the last read of this register
1 = Receive HDLC2 Controller Start of Reception (RxSOT) interrupt
has occurred since the last read of this register
4
TxEOT
RUR/
WC
0
Transmit HDLC2 Controller End of Transmission (TxEOT) Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Transmit
HDLC2 Controller End of Transmission (TxEOT) Interrupt has
occurred since the last read of this register. Transmit HDLC2 Controller will declare this interrupt when it has completed its transmission of a data link message. For sending large HDLC messages, it
is critical to load the next available buffer before this interrupt
occurs.
0 = Transmit HDLC2 Controller End of Transmission (TxEOT) interrupt has not occurred since the last read of this register
1 = Transmit HDLC2 Controller End of Transmission (TxEOT) interrupt has occurred since the last read of this register
140
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 115: DATA LINK STATUS REGISTER 2 (DLSR2)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0XnB16
TYPE
DEFAULT
DESCRIPTION-OPERATION
3
RxEOT
RUR/
WC
0
Receive HDLC2 Controller End of Reception (RxEOT) Interrupt
Status
This Reset-Upon-Read bit indicates whether or not the Receive
HDLC2 Controller End of Reception (RxEOT) Interrupt has occurred
since the last read of this register. Receive HDLC2 Controller will
declare this interrupt once it has completely received a full data link
message, or once the buffer is full.
0 = Receive HDLC2 Controller End of Reception (RxEOT) interrupt
has not occurred since the last read of this register
1 = Receive HDLC2 Controller End of Reception (RxEOT) Interrupt
has occurred since the last read of this register
2
FCS Error
RUR/
WC
0
FCS Error Interrupt Status
This Reset-Upon-Read bit indicates whether or not the FCS Error
Interrupt has occurred since the last read of this register. Receive
HDLC2 Controller will declare this interrupt when it has detected the
FCS error in the most recently received data link message.
0 = FCS Error interrupt has not occurred since the last read of this
register
1 = FCS Error interrupt has occurred since the last read of this register
1
Rx ABORT
RUR/
WC
0
Receipt of Abort Sequence Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Receipt of
Abort Sequence interrupt has occurred since last read of this register. Receive HDLC2 Controller will declare this interrupt if it detects
the Abort Sequence (i.e. a string of seven (7) consecutive 1’s) in the
incoming data link channel.
0 = Receipt of Abort Sequence interrupt has not occurred since last
read of this register
1 = Receipt of Abort Sequence interrupt has occurred since last
read of this register
0
RxIDLE
RUR/
WC
0
Receipt of Idle Sequence Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Receipt of
Idle Sequence interrupt has occurred since the last read of this register. The Receive HDLC2 Controller will declare this interrupt if it
detects the flag sequence octet (0x7E) in the incoming data link
channel. If RxIDLE "AND" RxEOT occur together, then the entire
HDLC message has been received.
0 = Receipt of Idle Sequence interrupt has not occurred since last
read of this register
1 = Receipt of Idle Sequence interrupt has occurred since last read
of this register.
141
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 116: DATA LINK INTERRUPT ENABLE REGISTER 2 (DLIER2)
BIT
FUNCTION
TYPE
DEFAULT
-
-
Reserved
HEX ADDRESS: 0XnB17
DESCRIPTION-OPERATION
7
Reserved
6
TxSOT ENB
R/W
0
Transmit HDLC2 Controller Start of Transmission (TxSOT)
Interrupt Enable
This bit enables or disables the “Transmit HDLC2
Controller Start of Transmission (TxSOT) “Interrupt within the
XRT86VL38 device. Once this interrupt is enabled, the Transmit
HDLC2 Controller will generate an interrupt when it has started to
transmit a data link message.
0 = Disables the Transmit HDLC2 Controller Start of Transmission
(TxSOT) interrupt.
1 = Enables the Transmit HDLC2 Controller Start of Transmission
(TxSOT) interrupt.
5
RxSOT ENB
R/W
0
Receive HDLC2 Controller Start of Reception (RxSOT) Interrupt
Enable
This bit enables or disables the “Receive HDLC2
Controller Start of Reception (RxSOT) “Interrupt within the
XRT86VL38 device. Once this interrupt is enabled, the Receive
HDLC2 Controller will generate an interrupt when it has started to
receive a data link message.
0 = Disables the Receive HDLC2 Controller Start of Reception
(RxSOT) interrupt.
1 = Enables the Receive HDLC2 Controller Start of Reception
(RxSOT) interrupt.
4
TxEOT ENB
R/W
0
Transmit HDLC2 Controller End of Transmission (TxEOT) Interrupt Enable
This bit enables or disables the “Transmit HDLC2
Controller End of Transmission (TxEOT) “Interrupt within the
XRT86VL38 device. Once this interrupt is enabled, the Transmit
HDLC2 Controller will generate an interrupt when it has finished
transmitting a data link message.
0 = Disables the Transmit HDLC2 Controller End of Transmission
(TxEOT) interrupt.
1 = Enables the Transmit HDLC2 Controller End of Transmission
(TxEOT) interrupt.
3
RxEOT ENB
R/W
0
Receive HDLC2 Controller End of Reception (RxEOT) Interrupt
Enable
This bit enables or disables the “Receive HDLC2
Controller End of Reception (RxEOT) “Interrupt within the
XRT86VL38 device. Once this interrupt is enabled, the Receive
HDLC2 Controller will generate an interrupt when it has finished
receiving a complete data link message.
0 = Disables the Receive HDLC2 Controller End of Reception
(RxEOT) interrupt.
1 = Enables the Receive HDLC2 Controller End of Reception
(RxEOT) interrupt.
142
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 116: DATA LINK INTERRUPT ENABLE REGISTER 2 (DLIER2)
BIT
FUNCTION
TYPE
DEFAULT
REV. V1.2.1
HEX ADDRESS: 0XnB17
DESCRIPTION-OPERATION
2
FCS ERR ENB
R/W
0
FCS Error Interrupt Enable
This bit enables or disables the “Received FCS Error “Interrupt
within the XRT86VL38 device. Once this interrupt is enabled, the
Receive HDLC2 Controller will generate an interrupt when it has
detected the FCS error within the incoming data link message.
0 = Disables the “Receive FCS Error” interrupt.
1 = Enables the “Receive FCS Error” interrupt.
1
RxABORT ENB
R/W
0
Receipt of Abort Sequence Interrupt Enable
This bit enables or disables the “Receipt of Abort Sequence“ Interrupt within the XRT86VL38 device. Once this interrupt is enabled,
the Receive HDLC2 Controller will generate an interrupt when it has
detected the Abort Sequence (i.e. a string of seven (7) consecutive
1’s) within the incoming data link channel.
0 = Disables the “Receipt of Abort Sequence” interrupt.
1 = Enables the “Receipt of Abort Sequence” interrupt.
0
RxIDLE ENB
R/W
0
Receipt of Idle Sequence Interrupt Enable
This bit enables or disables the “Receipt of Idle Sequence“ Interrupt
within the XRT86VL38 device. Once this interrupt is enabled, the
Receive HDLC2 Controller will generate an interrupt when it has
detected the Idle Sequence Octet (i.e. 0x7E) within the incoming
data link channel.
0 = Disables the “Receipt of Idle Sequence” interrupt.
1 = Enables the “Receipt of Idle Sequence” interrupt.
143
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 117: SS7 STATUS REGISTER FOR LAPD2 (SS7SR2)
BIT
0
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
SS7_2_STATUS
RUR/
WC
0
SS7 Interrupt Status for LAPD Controller 2
This Reset-Upon-Read bit field indicates whether or not the “SS7”
interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt when the Received LAPD message is more
than 276 Bytes in length.
0 = Indicates that the “SS7” interrupt has not occurred since the last
read of this register
1 = Indicates that the “SS7” interrupt has occurred since the last
read of this register
TABLE 118: SS7 ENABLE REGISTER FOR LAPD2 (SS7ER2)
BIT
0
HEX ADDRESS: 0XnB18
FUNCTION
SS7_2_ENB
TYPE
DEFAULT
R/W
0
HEX ADDRESS: 0XnB19
DESCRIPTION-OPERATION
SS7 Interrupt Enable for LAPD Controller 2
This bit enables or disables the “SS7” interrupt within the LAPD
Controller 2.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt when the Received LAPD message is more
than 276 Bytes in length.
0 - Disables the “SS7” interrupt within the LAPD Controller 2.
1 - Enables the “SS7” interrupt within the LAPD Controller 2.
144
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 119: DATA LINK STATUS REGISTER 3 (DLSR3)
BIT
FUNCTION
REV. V1.2.1
HEX ADDRESS: 0XNB26
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
MSG TYPE
RUR/
WC
0
HDLC3 Message Type Identifier
This READ ONLY bit indicates the type of data link message received
by Receive HDLC 3 Controller. Two types of data link messages are
supported within the XRT86VL38 device: Message Oriented Signaling
(MOS) or Bit-Oriented Signalling (BOS).
0 = Indicates Bit-Oriented Signaling (BOS) type data link message is
received
1 = Indicates Message Oriented Signaling (MOS) type data link message is received
6
TxSOT
RUR/
WC
0
Transmit HDLC3 Controller Start of Transmission (TxSOT) Interrupt Status
This Reset-Upon-Read bit indicates whether or not the “Transmit
HDLC3 Controller Start of Transmission (TxSOT) “Interrupt has
occurred since the last read of this register. Transmit HDLC3 Controller
will declare this interrupt when it has started to transmit a data link message. For sending large HDLC messages, start loading the next available buffer once this interrupt is detected.
0 = Transmit HDLC3 Controller Start of Transmission (TxSOT) interrupt
has not occurred since the last read of this register
1 = Transmit HDLC3 Controller Start of Transmission interrupt (TxSOT)
has occurred since the last read of this register.
5
RxSOT
RUR/
WC
0
Receive HDLC3 Controller Start of Reception (RxSOT) Interrupt
Status
This Reset-Upon-Read bit indicates whether or not the Receive
HDLC3 Controller Start of Reception (RxSOT) interrupt has occurred
since the last read of this register. Receive HDLC3 Controller will
declare this interrupt when it has started to receive a data link message.
0 = Receive HDLC3 Controller Start of Reception (RxSOT) interrupt
has not occurred since the last read of this register
1 = Receive HDLC3 Controller Start of Reception (RxSOT) interrupt
has occurred since the last read of this register
4
TxEOT
RUR/
WC
0
Transmit HDLC3 Controller End of Transmission (TxEOT) Interrupt
Status
This Reset-Upon-Read bit indicates whether or not the Transmit
HDLC3 Controller End of Transmission (TxEOT) Interrupt has occurred
since the last read of this register. Transmit HDLC3 Controller will
declare this interrupt when it has completed its transmission of a data
link message. For sending large HDLC messages, it is critical to load
the next available buffer before this interrupt occurs.
0 = Transmit HDLC3 Controller End of Transmission (TxEOT) interrupt
has not occurred since the last read of this register
1 = Transmit HDLC3 Controller End of Transmission (TxEOT) interrupt
has occurred since the last read of this register
145
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 119: DATA LINK STATUS REGISTER 3 (DLSR3)
BIT
FUNCTION
HEX ADDRESS: 0XNB26
TYPE
DEFAULT
DESCRIPTION-OPERATION
3
RxEOT
RUR/
WC
0
Receive HDLC3 Controller End of Reception (RxEOT) Interrupt
Status
This Reset-Upon-Read bit indicates whether or not the Receive
HDLC3 Controller End of Reception (RxEOT) Interrupt has occurred
since the last read of this register. Receive HDLC3 Controller will
declare this interrupt once it has completely received a full data link
message, or once the buffer is full.
0 = Receive HDLC3 Controller End of Reception (RxEOT) interrupt has
not occurred since the last read of this register
1 = Receive HDLC3 Controller End of Reception (RxEOT) Interrupt has
occurred since the last read of this register
2
FCS Error
RUR/
WC
0
FCS Error Interrupt Status
This Reset-Upon-Read bit indicates whether or not the FCS Error Interrupt has occurred since the last read of this register. Receive HDLC3
Controller will declare this interrupt when it has detected the FCS error
in the most recently received data link message.
0 = FCS Error interrupt has not occurred since the last read of this register
1 = FCS Error interrupt has occurred since the last read of this register
1
Rx ABORT
RUR/
WC
0
Receipt of Abort Sequence Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Receipt of Abort
Sequence interrupt has occurred since last read of this register.
Receive HDLC3 Controller will declare this interrupt if it detects the
Abort Sequence (i.e. a string of seven (7) consecutive 1’s) in the
incoming data link channel.
0 = Receipt of Abort Sequence interrupt has not occurred since last
read of this register
1 = Receipt of Abort Sequence interrupt has occurred since last read of
this register
0
RxIDLE
RUR/
WC
0
Receipt of Idle Sequence Interrupt Status
This Reset-Upon-Read bit indicates whether or not the Receipt of Idle
Sequence interrupt has occurred since the last read of this register.
The Receive HDLC3 Controller will declare this interrupt if it detects the
flag sequence octet (0x7E) in the incoming data link channel. If RxIDLE "AND" RxEOT occur together, then the entire HDLC message has
been received.
0 = Receipt of Idle Sequence interrupt has not occurred since last read
of this register
1 = Receipt of Idle Sequence interrupt has occurred since last read of
this register.
146
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 120: DATA LINK INTERRUPT ENABLE REGISTER 3 (DLIER3)
BIT
FUNCTION
TYPE
DEFAULT
-
-
Reserved
REV. V1.2.1
HEX ADDRESS: 0XnB27
DESCRIPTION-OPERATION
7
Reserved
6
TxSOT ENB
R/W
0
Transmit HDLC3 Controller Start of Transmission (TxSOT)
Interrupt Enable
This bit enables or disables the “Transmit HDLC3
Controller Start of Transmission (TxSOT) “Interrupt within the
XRT86VL38 device. Once this interrupt is enabled, the Transmit
HDLC3 Controller will generate an interrupt when it has started to
transmit a data link message.
0 = Disables the Transmit HDLC3 Controller Start of Transmission
(TxSOT) interrupt.
1 = Enables the Transmit HDLC3 Controller Start of Transmission
(TxSOT) interrupt.
5
RxSOT ENB
R/W
0
Receive HDLC3 Controller Start of Reception (RxSOT) Interrupt
Enable
This bit enables or disables the “Receive HDLC3
Controller Start of Reception (RxSOT) “Interrupt within the
XRT86VL38 device. Once this interrupt is enabled, the Receive
HDLC3 Controller will generate an interrupt when it has started to
receive a data link message.
0 = Disables the Receive HDLC3 Controller Start of Reception
(RxSOT) interrupt.
1 = Enables the Receive HDLC3 Controller Start of Reception
(RxSOT) interrupt.
4
TxEOT ENB
R/W
0
Transmit HDLC3 Controller End of Transmission (TxEOT) Interrupt Enable
This bit enables or disables the “Transmit HDLC3
Controller End of Transmission (TxEOT) “Interrupt within the
XRT86VL38 device. Once this interrupt is enabled, the Transmit
HDLC3 Controller will generate an interrupt when it has finished
transmitting a data link message.
0 = Disables the Transmit HDLC3 Controller End of Transmission
(TxEOT) interrupt.
1 = Enables the Transmit HDLC3 Controller End of Transmission
(TxEOT) interrupt.
3
RxEOT ENB
R/W
0
Receive HDLC3 Controller End of Reception (RxEOT) Interrupt
Enable
This bit enables or disables the “Receive HDLC3
Controller End of Reception (RxEOT) “Interrupt within the
XRT86VL38 device. Once this interrupt is enabled, the Receive
HDLC3 Controller will generate an interrupt when it has finished
receiving a complete data link message.
0 = Disables the Receive HDLC3 Controller End of Reception
(RxEOT) interrupt.
1 = Enables the Receive HDLC3 Controller End of Reception
(RxEOT) interrupt.
147
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 120: DATA LINK INTERRUPT ENABLE REGISTER 3 (DLIER3)
BIT
FUNCTION
TYPE
DEFAULT
HEX ADDRESS: 0XnB27
DESCRIPTION-OPERATION
2
FCS ERR ENB
R/W
0
FCS Error Interrupt Enable
This bit enables or disables the “Received FCS Error “Interrupt
within the XRT86VL38 device. Once this interrupt is enabled, the
Receive HDLC3 Controller will generate an interrupt when it has
detected the FCS error within the incoming data link message.
0 = Disables the “Receive FCS Error” interrupt.
1 = Enables the “Receive FCS Error” interrupt.
1
RxABORT ENB
R/W
0
Receipt of Abort Sequence Interrupt Enable
This bit enables or disables the “Receipt of Abort Sequence“ Interrupt within the XRT86VL38 device. Once this interrupt is enabled,
the Receive HDLC3 Controller will generate an interrupt when it has
detected the Abort Sequence (i.e. a string of seven (7) consecutive
1’s) within the incoming data link channel.
0 = Disables the “Receipt of Abort Sequence” interrupt.
1 = Enables the “Receipt of Abort Sequence” interrupt.
0
RxIDLE ENB
R/W
0
Receipt of Idle Sequence Interrupt Enable
This bit enables or disables the “Receipt of Idle Sequence“ Interrupt
within the XRT86VL38 device. Once this interrupt is enabled, the
Receive HDLC3 Controller will generate an interrupt when it has
detected the Idle Sequence Octet (i.e. 0x7E) within the incoming
data link channel.
0 = Disables the “Receipt of Idle Sequence” interrupt.
1 = Enables the “Receipt of Idle Sequence” interrupt.
148
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 121: SS7 STATUS REGISTER FOR LAPD3 (SS7SR3)
BIT
0
0
HEX ADDRESS: 0XnB28
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
SS7_3_STATUS
RUR/
WC
0
SS7 Interrupt Status for LAPD Controller 3
This Reset-Upon-Read bit field indicates whether or not the “SS7”
interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt when the Received LAPD message is more
than 276 Bytes in length.
0 = Indicates that the “SS7” interrupt has not occurred since the last
read of this register
1 = Indicates that the “SS7” interrupt has occurred since the last
read of this register
TABLE 122: SS7 ENABLE REGISTER FOR LAPD3 (SS7ER3)
BIT
REV. V1.2.1
FUNCTION
SS7_3_ENB
TYPE
DEFAULT
R/W
0
HEX ADDRESS: 0XNB29
DESCRIPTION-OPERATION
SS7 Interrupt Enable for LAPD Controller 3
This bit enables or disables the “SS7” interrupt within the LAPD
Controller 3.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt when the Received LAPD message is more
than 276 Bytes in length.
0 - Disables the “SS7” interrupt within the LAPD Controller 3.
1 - Enables the “SS7” interrupt within the LAPD Controller 3.
149
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
2.0 LINE INTERFACE UNIT (LIU SECTION) REGISTERS
TABLE 123: LIU CHANNEL CONTROL REGISTER 0 (LIUCCR0)
BIT
FUNCTION
TYPE
DEFAULT
7
QRSS_n/
PRBS_n
R/W
0
HEX ADDRESS: 0X0FN0
DESCRIPTION-OPERATION
QRSS/PRBS Select Bits
These bits are used to select between QRSS and PRBS.
0 = PRBS_n (215 - 1)
1 = QRSS_n (220 - 1)
6
PRBS_Rx_n/
PRBS_Tx_n
R/W
0
PRBS Receive/Transmit Select:
This bit is used select where the output of the PRBS Generator is
directed.
0 = PRBS Generator is output on TTIP and TRING
1 = PRBS Generator is output on RPOS and RCLK
NOTE: When this bit is set "High" the customer must ground RNEG.
Bit D6 = "0"
+
PBRS
Generator
Clock
TTIP
Tx
TRING
Bit D6 = "1"
+
PBRS
Generator
Clock
TTIP
Tx
TRING
RPOS
RNEG
RCLK
150
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 123: LIU CHANNEL CONTROL REGISTER 0 (LIUCCR0)
REV. V1.2.1
HEX ADDRESS: 0X0FN0
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
5
RXON_n
R/W
0
Receiver ON:
This bit permits the user to either turn on or turn off the Receive Section of XRT86VL38. If the user turns on the Receive Section, then
XRT86VL38 will begin to receive the incoming data-stream via the
RTIP and RRING input pins.
Conversely, if the user turns off the Receive Section, then the entire
Receive Section except the MCLKIN Phase Locked Loop (PLL) will
be powered down.
0 = Shuts off the Receive Section of XRT86VL38.
1 = Turns on the Receive Section of XRT86VL38.
4-0
EQC[4:0]
R/W
00000
Equalizer Control [4:0]:
These bits are used to control the transmit pulse shaping, transmit
line build-out (LBO) and receive sensitivity level.
The Transmit Pulse Shape can be controlled by adjusting the Transmit Line Build-Out Settings for different cable length in E1 mode.
Transmit pulse shape can also be controlled by using the Arbitrary
mode, where users can specify the amplitude of the pulse shape by
using the 8 Arbitrary Pulse Segments provided in the LIU registers
(0x0Fn8-0xnFnF), where n is the channel number.
The XRT86VL38 device supports both long haul and short haul
applications which can also be selected using the EQC[4:0] bits.
Table 124 presents the corresponding Transmit Line Build Out and
Receive Sensitivity settings using different combinations of these
five EQC[4:0] bits.
151
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 124: EQUALIZER CONTROL AND TRANSMIT LINE BUILD OUT
EQC[4:0]
T1 MODE/RECEIVE SENSITIVITY
TRANSMIT LBO
CABLE
0x00h
T1 Long Haul/36dB
0dB
100Ω TP
0x01h
T1 Long Haul/36dB
-7.5dB
100Ω TP
0x02h
T1 Long Haul/36dB
-15dB
100Ω TP
0x03h
T1 Long Haul/36dB
-22.5dB
100Ω TP
0x04h
T1 Long Haul/45dB
0dB
100Ω TP
0x05h
T1 Long Haul/45dB
-7.5dB
100Ω TP
0x06h
T1 Long Haul/45dB
-15dB
100Ω TP
0x07h
T1 Long Haul/45dB
-22.5dB
100Ω TP
0x08h
T1 Short Haul/15dB
0 to 133 feet (0.6dB)
100Ω TP
0x09h
T1 Short Haul/15dB
133 to 266 feet (1.2dB)
100Ω TP
0x0Ah
T1 Short Haul/15dB
266 to 399 feet (1.8dB)
100Ω TP
0x0Bh
T1 Short Haul/15dB
399 to 533 feet (2.4dB)
100Ω TP
0x0Ch
T1 Short Haul/15dB
533 to 655 feet (3.0dB)
100Ω TP
0x0Dh
T1 Short Haul/15dB
Arbitrary Pulse
100Ω TP
0x0Eh
T1 Gain Mode/29dB
0 to 133 feet (0.6dB)
100Ω TP
0x0Fh
T1 Gain Mode/29dB
133 to 266 feet (1.2dB)
100Ω TP
0x10h
T1 Gain Mode/29dB
266 to 399 feet (1.8dB)
100Ω TP
0x11h
T1 Gain Mode/29dB
399 to 533 feet (2.4dB)
100Ω TP
0x12h
T1 Gain Mode/29dB
533 to 655 feet (3.0dB)
100Ω TP
0x13h
T1 Gain Mode/29dB
Arbitrary Pulse
100Ω TP
0x14h
T1 Gain Mode/29dB
0dB
100Ω TP
0x15h
T1 Gain Mode/29dB
-7.5dB
100Ω TP
0x16h
T1 Gain Mode/29dB
-15dB
100Ω TP
0x17h
T1 Gain Mode/29dB
-22.5dB
100Ω TP
0x18h
E1 Long Haul/36dB
ITU G.703
75Ω Coax
0x19h
E1 Long Haul/36dB
ITU G.703
120Ω TP
0x1Ah
E1 Long Haul/45dB
ITU G.703
75Ω Coax
0x1Bh
E1 Long Haul/45dB
ITU G.703
120Ω TP
0x1Ch
E1 Short Haul/15dB
ITU G.703
75Ω Coax
0x1Dh
E1 Short Haul/15dB
ITU G.703
120Ω TP
0x1Eh
E1 Gain Mode/29dB
ITU G.703
75Ω Coax
0x1Fh
E1 Gain Mode/29dB
ITU G.703
120Ω TP
152
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 125: LIU CHANNEL CONTROL REGISTER 1 (LIUCCR1)
HEX ADDRESS: 0X0FN1
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
RXTSEL_n
R/W
0
Receiver Termination Select:
Upon power up, the receivers are in “High” impedance. The LIU provides an option for user to have either software or hardware control
over receive termination. If RxTCNTL (bit 6 in Register 0x0FE2) is
set to’0’, receive termination can be selected by programming this
register bit. To switch control to the hardware pin (RxTSEL pin),
RxTCNTL must be programmed to “1”. Once control has been
granted to the hardware pin, RxTSEL must be pulled “High” to
switch to internal termination.
If RxTCNTL is set to’0’, receive termination can be selected by setting this bit according to the following table:
RXTSEL
6
5-4
TXTSEL_n
TERSEL[1:0]
R/W
R/W
0
00
RX Termination
0
"High" Impedance
1
Internal
Transmit Termination Select:
This bit is used to select between internal termination or “High”
impedance modes for the E1 transmitter according to the following
table:
TXTSEL
TX Termination
0
"High" Impedance
1
Internal
Termination Impedance Select [1:0]:
These bits are used to control the transmit and receive termination
impedance when the LIU block is configured in Internal Termination
Mode.
In internal termination mode, (i.e., TXTSEL = “1” and RXTSEL =
“1”), internal transmit and receive termination can be selected
according to the following table:
NOTE:
TERSEL1
TERSEL0
Internal Transmit
and Receive
Termination
0
0
100Ω
0
1
110Ω
1
0
75Ω
1
1
120Ω
In the internal termination mode, the transmitter output
should be AC coupled to the transformer.
153
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 125: LIU CHANNEL CONTROL REGISTER 1 (LIUCCR1)
HEX ADDRESS: 0X0FN1
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
3
RxJASEL_n
R/W
0
Receive Jitter Attenuator Enable
This bit permits the user to enable or disable the Jitter Attenuator in
the Receive Path within the XRT86VL38 device.
0 = Disables the Jitter Attenuator to operate in the Receive Path
within the Receive E1 LIU Block.
1 = Enables the Jitter Attenuator to operate in the Receive Path
within the Receive E1 LIU Block.
2
TxJASEL_n
R/W
0
Transmit Jitter Attenuator Enable
This bit permits the user to enable or disable the Jitter Attenuator in
the Transmit Path within the XRT86VL38 device.
0 = Disables the Jitter Attenuator to operate in the Transmit Path
within the Transmit E1 LIU Block.
1 = Enables the Jitter Attenuator to operate in the Transmit Path
within the Transmit E1 LIU Block.
1
JABW_n
R/W
0
Jitter Attenuator Bandwidth Select:
In E1 mode, this bit is used to select the Jitter Attenuator Bandwidth
as well as the FIFO size.
1 = Selects a 1.5Hz Bandwidth for the Jitter Attenuator. The FIFO
length will be automatically set to 64 bits.
0 = Setting this bit to “0” will select 10Hz Bandwidth for the Jitter
Attenuator. The FIFOS (bit D0 of this register) will be used to select
the FIFO size.
The table below presents the Jitter Attenuator and FIFO settings
corresponding to the combinations of this JABW and FIFOS bits in
both T1 and E1 mode.
0
FIFOS_n
R/W
0
Mode
JABW
bit D1
FIFOS_n
bit D0
JA B-W
Hz
FIFO
Size
T1
0
0
3
32
T1
0
1
3
64
T1
1
0
3
32
T1
1
1
3
64
E1
0
0
10
32
E1
0
1
10
64
E1
1
0
1.5
64
E1
1
1
1.5
64
FIFO Size Select: See table of bit D1 above for the function of this
bit.
154
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 126: LIU CHANNEL CONTROL REGISTER 2 (LIUCCR2)
BIT
FUNCTION
TYPE
DEFAULT
7
INVQRSS_n
R/W
0
6-4
TXTEST[2:0]
R/W
000
HEX ADDRESS: 0X0FN2
DESCRIPTION-OPERATION
Invert QRSS Pattern:
This bit inverts the output PRBS/QRSS pattern if the LIU Block is
configured to transmit a PRBS/QRSS pattern.
0 = Inverts PRBS, NOT Inverts QRSS
1 = NOT Inverts PRBS, Inverts QRSS
Transmit Test Pattern [2:0]:
These bits are used to configure the Transmit E1 LIU Block to generate and transmit test patterns according to the following table.
Use of these bits automatically places the LIU section in Single Rail
mode. When this happens, the Framer section must be placed in
Single Rail mode in Reg 0xn101.
TXTEST2
TXTEST1
TXTEST0
Test Pattern
0
X
X
No Pattern
1
0
0
TDQRSS
1
0
1
TAOS
1
1
0
TLUC
1
1
1
TLDC
TDQRSS (Transmit/Detect Quasi-Random Signal):
QRSS pattern is a 215-1 pseudo-random bit sequence (PRBS) pattern.
TAOS (Transmit All Ones):
Whenever the user implements this configuration setting, the Transmit E1 LIU Block will ignore the data that it is accepting from the
Transmit E1 Framer block (as well as the upstream system-side terminal equipment) and overwrite this data with the All Ones Pattern.
TLUC (Transmit Network Loop-Up Code):
The Transmit E1 LIU Block will generate and transmit the Network
Loop-Up Code of “00001” to the line for the selected channel number n.
When Network Loop-Up code is being transmitted, the XRT86VL38
will ignore the “Automatic Loop-Code detection and Remote LoopBack activation” (NLCDE1 =“1”, NLCDE0 =“1” of register 0x0Fn3) in
order to avoid activating Remote Digital Loop-Back automatically
when the remote terminal responds to the Loop-Back request.
TLDC (Transmit Network Loop-Down Code):
The Transmit E1 LIU Block will generate and transmit the Network
Loop-Down Code of “001” to the line for the selected channel number n.
155
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 126: LIU CHANNEL CONTROL REGISTER 2 (LIUCCR2)
HEX ADDRESS: 0X0FN2
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
3
TXON_n
R/W
0
Transmitter ON:
This bit permits the user to either turn on or turn off the Transmit
Driver of XRT86VL38. If the user turns on the Transmit Driver, then
XRT86VL38 will begin to transmit DS1 data (on the line) via the
TTIP and TRING output pins.
Conversely, if the user turns off the Transmit Driver, then the TTIP
and TRING output pins will be tri-stated.
0 = Shuts off the Transmit Driver associated with the XRT86VL38
device and tri-states the TTIP and TRING output pins.
1 = Turns on the Transmit Driver associated with the XRT86VL38
device.
NOTE: If the user wishes to exercise software control over the state
of the Transmit Driver of the XRT86VL38, then it is
imperative that the user pull the TxON pin to a logic “HIGH”
level.
2-0
LOOP2_n
R/W
000
Loop-Back control [2:0]:
These bits control the Loop-Back Modes of the LIU section, according to the table below.
LOOP2
LOOP1
LOOP0
0
X
X
No Loop-Back
1
0
0
Dual Loop-Back
1
0
1
Analog Loop-Back
1
1
0
Remote Loop-Back
1
1
1
Digital Loop-Back
156
Loop-Back Mode
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 127: LIU CHANNEL CONTROL REGISTER 3 (LIUCCR3)
BIT
FUNCTION
TYPE
DEFAULT
7-6
NLCDE[1:0]
R/W
00
REV. V1.2.1
HEX ADDRESS: 0X0FN3
DESCRIPTION-OPERATION
Network Loop Code Detection Enable [1:0]:
These bits are used to control the Loop-Code detection on the
receive path of each channel, according to the table below. This
part must be in Single Rail mode to detect.
NETWORK LOOP CODE DETECTION
ENABLE
NLCDE[1:0]
00
Disables Loop Code Detection
01
Enables Loop-Up Code Detection on
the Receive Path.
10
Enables Loop-Down Code Detection
on the Receive Path.
11
Enables Automatic Loop-Up Code
Detection on the Receive Path and
Remote Loop-Back Activation upon
detecting Loop-Up Code.
Loop-Up Code Detection Enable:
The XRT86VL38 is configured to monitor the receive data for the
Loop-Up code Pattern (i.e. a string of four ‘0’s followed by one ‘1’
pattern). When the presence of the “00001” pattern is detected for
more than 5 seconds, the status of the NLCD bit (bit 3 of register
0x0Fn5) is set to “1” and if the NLCD interrupt is enabled (bit 3 of
register 0x0Fn4), an interrupt will be generated.
Loop-Down Code Detection Enable:
The XRT86VL38 is configured to monitor the receive data for the
Loop-Down code Pattern (i.e. a string of two ‘0’s followed by one ‘1’
pattern). When the presence of the “001” pattern is detected for
more than 5 seconds, the status of the NLCD bit (bit 3 of register
0x0Fn5) is set to “1” and if the NLCD interrupt is enabled (bit 3 of
register 0x0Fn4), an interrupt will be generated.
Automatic Loop-Up Code Detection and Remote Loop Back
Activation Enable:
When this mode is enabled, the state of the NLCD bit (bit 3 of register 0x0Fn5) is reset to “0” and the XRT86VL38 is configured to monitor the receive data for the Loop-Up code. If the “00001” pattern is
detected for longer than 5 seconds, then the NLCD bit (bit 3 of register 0x0Fn5) is set “1”, and Remote Loop-Back is activated. Once the
remote loop-back is activated, the XRT86VL38 is automatically programmed to monitor the receive data for the Loop-Down code. The
NLCD bit stays set even after the chip stops receiving the Loop-Up
code.
The Remote Loop-Back condition is removed only when the
XRT86VL38 receives the Loop-Down code for more than 5 seconds
or if the Automatic Loop-Code detection mode is terminated.
5-2
Reserved
R/W
0
This Bit Is Not Used
157
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 127: LIU CHANNEL CONTROL REGISTER 3 (LIUCCR3)
HEX ADDRESS: 0X0FN3
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
1
INSBER_n
R/W
0
Insert Bit Error:
This bit is used to insert a single bit error on the transmitter of the E1
LIU Block.
When the E1 LIU Block is configured to transmit and detect the
QRSS pattern, (i.e., TxTEST[2:0] bits set to ‘b100’), a “0” to “1” transition of this bit will insert a bit error in the transmitted QRSS pattern
of the selected channel number n.
The state of this bit is sampled on the rising edge of the respective
TCLK_n.
NOTE: To ensure the insertion of bit error, a “0” should be written in
this bit location before writing a “1”.
0
Reserved
R/W
0
This Bit Is Not Used
158
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 128: LIU CHANNEL CONTROL INTERRUPT ENABLE REGISTER (LIUCCIER)
REV. V1.2.1
HEX ADDRESS: 0X0FN4
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
Reserved
RO
0
This Bit Is Not Used
6
DMOIE_n
R/W
0
Change of Transmit DMO (Drive Monitor Output) Condition Interrupt Enable:
This bit permits the user to either enable or disable the “Change of
Transmit DMO Condition” Interrupt. If the user enables this interrupt,
then the XRT86VL38 device will generate an interrupt any time when
either one of the following events occur.
1. Whenever the Transmit Section toggles the DMO Status bit (Bit 6
or Register 0x0Fn5) to “1”.
2. Whenever the Transmit Section toggles the DMO Status bit (Bit 6
or Register 0x0Fn5) to “0”.
0 – Disables the “Change in the DMO Condition” Interrupt.
1 – Enables the “Change in the DMO Condition” Interrupt.
5
FLSIE_n
R/W
0
FIFO Limit Status Interrupt Enable:
This bit permits the user to either enable or disable the “FIFO Limit Status” Interrupt. If the user enables this interrupt, then the XRT86VL38
device will generate an interrupt when the jitter attenuator Read/Write
FIFO pointers are within +/- 3 bits.
0 = Disables the “FIFO Limit Status” Interrupt
1 = Enables the “FIFO Limit Status” Interrupt
4
Reserved
-
-
This bit is not used.
3
NLCDIE_n
R/W
0
Change in Network Loop-Code Detection Interrupt Enable:
This bit permits the user to either enable or disable the “Change in Network Loop-Code Detection” Interrupt. If the user enables this interrupt,
then the XRT86VL38 device will generate an interrupt any time when
either one of the following events occur.
1. Whenever the Receive Section (within XRT86VL38) detects the
Network Loop-Code (Loop-Up or Loop-Down depending on which
Loop-Code the Receive LIU is configured to detect).
2. Whenever the Receive Section (within XRT86VL38) no longer
detects the Network Loop-Code (Loop-Up or Loop-Down
depending on which Loop-Code the Receive LIU is configured to
detect).
0 – Disables the “Change in Network Loop-Code Detection” Interrupt.
1 – Enables the “Change in Network Loop-Code Detection” Interrupt.
2
Reserved
-
-
This bit is not used
159
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 128: LIU CHANNEL CONTROL INTERRUPT ENABLE REGISTER (LIUCCIER)
HEX ADDRESS: 0X0FN4
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
1
RLOSIE_n
R/W
0
Change of the Receive LOS (Loss of Signal) Defect Condition Interrupt Enable:
This bit permits the user to either enable or disable the “Change of the
Receive LOS Defect Condition” Interrupt. If the user enables this interrupt, then the XRT86VL38 device will generate an interrupt any time
when either one of the following events occur.
1. Whenever the Receive Section (within XRT86VL38) declares the
LOS Defect Condition.
2. Whenever the Receive Section (within XRT86VL38) clears the
LOS Defect condition.
0 – Disables the “Change in the LOS Defect Condition” Interrupt.
1 – Enables the “Change in the LOS Defect Condition” Interrupt.
0
QRPDIE_n
R/W
0
Change in QRSS Pattern Detection Interrupt Enable:
This bit permits the user to either enable or disable the “Change in
QRSS Pattern Detection” Interrupt. If the user enables this interrupt,
then the XRT86VL38 device will generate an interrupt any time when
either one of the following events occur.
1. Whenever the Receive Section (within XRT86VL38) detects the
QRSS Pattern.
2. Whenever the Receive Section (within XRT86VL38) no longer
detects the QRSS Pattern.
0 – Disables the “Change in QRSS Pattern Detection” Interrupt.
1 – Enables the “Change in QRSS Pattern Detection” Interrupt.
NOTE: Register 0x0FN4, 0x0FN5 and 0x0FN6 only work if the LIU is placed in Single Rail mode. If done so, the Framer
block must also be placed in Single Rail mode in Register 0xn101.
160
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 129: LIU CHANNEL CONTROL STATUS REGISTER (LIUCCSR)
BIT
FUNCTION
TYPE
DEFAULT
7
Reserved
RO
0
6
DMO_n
RO
0
REV. V1.2.1
HEX ADDRESS: 0X0FN5
DESCRIPTION-OPERATION
Driver Monitor Output (DMO) Status:
This READ-ONLY bit indicates whether or not the Transmit Section
is currently declaring the DMO Alarm condition.
The Transmit Section will check the Transmit Output E1 Line signal
for bipolar pulses via the TTIP and TRING output signals. If the
Transmit Section were to detect no bipolar signal for 128 consecutive bit-periods, then it will declare the Transmit DMO Alarm condition. This particular alarm can be used to check for fault conditions
on the Transmit Output Line Signal path.
The Transmit Section will clear the Transmit DMO Alarm condition
the instant that it detects some bipolar activity on the Transmit Output Line signal.
0 = Indicates that the Transmit Section of XRT86VL38 is NOT currently declaring the Transmit DMO Alarm condition.
1 = Indicates that the Transmit Section of XRT86VL38 is currently
declaring the Transmit DMO Alarm condition.
NOTE: If the DMO interrupt is enabled (DMOIE - bit D6 of register
0x0Fn4), any transition on this bit will generate an Interrupt.
5
FLS_n
RO
0
FIFO Limit Status:
This READ-ONLY bit indicates whether or not the XRT86VL38 is
currently declaring the FIFO Limit Status.
This bit is set to a “1” to indicate that the jitter attenuator Read/Write
FIFO pointers are within +/- 3 bits.
0 = Indicates that the XRT86VL38 is NOT currently declaring the
FIFO Limit Status.
1 = Indicates that the XRT86VL38 is currently declaring the FIFO
Limit Status.
NOTE: If the FIFO Limit Status Interrupt is enabled, (FLSIE bit - bit
D5 of register 0x0Fn4), any transition on this bit will
generate an Interrupt.
4
Reserved
-
0
This Bit Is Not Used
161
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 129: LIU CHANNEL CONTROL STATUS REGISTER (LIUCCSR)
HEX ADDRESS: 0X0FN5
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
3
NLCD_n
RO
0
Network Loop-Code Detection Status Bit:
This bit operates differently in the Manual or the Automatic Network
Loop-Code detection modes.
Manual Loop-Up Code detection mode
(.i.e If NLCDE1 = “0” and NLCDE0 = “1”), this bit gets set to “1” as
soon as the Loop-Up Code (“00001”) is detected in the receive data
for longer than 5 seconds.
This bit stays high as long as the Receive E1 LIU Block detects the
presence of the Loop-Up code in the receive data and it is reset to
“0” as soon as it stops receiving the Loop-Up Code.
If the NLCD interrupt is enabled, the XRT86VL38 will initiate an
interrupt on every transition of the NLCD status bit.
Manual Loop-Down Code detection mode
(i.e., If NLCDE1 = “1” and NLCDE0 = “0”), this bit gets set to “1” as
soon as the Loop-Down Code (“001”) is detected in the receive data
for longer than 5 seconds.
This bit stays high as long as the Receive E1 LIU Block detects the
presence of the Loop-Down code in the receive data and it is reset
to “0” as soon as it stops receiving the Loop-Down Code.
If the NLCD interrupt is enabled, the XRT86VL38 will initiate an
interrupt on every transition of the NLCD status bit.
Automatic Loop-code detection mode
(i.e., If NLCDE1 = “1” and NLCDE0 =”1”), the state of the NLCD status bit is reset to “0” and the XRT86VL38 is programmed to monitor
the receive input data for the Loop-Up code.
This bit is set to a “1” to indicate that the Network Loop Code is
detected for more than 5 seconds. Simultaneously the Remote
Loop-Back condition is automatically activated and the XRT86VL38
is programmed to monitor the receive data for the Network Loop
Down code. The NLCD bit stays ‘high’ as long as the Remote LoopBack condition is in effect even if the chip stops receiving the LoopUp code. Remote Loop-Back is removed only if the XRT86VL38
detects the Loop-Down Code “001” pattern for longer than 5 seconds in the receive data. Upon detecting the Loop-Down Code “001”
pattern, the XRT86VL38 will reset the NLCD status bit and an interrupt will be generated if the NLCD interrupt enable bit is enabled.
Users can monitor the state of this bit to determine if the Remote
Loop-Back is activated.
2
Reserved
-
0
This Bit Is Not Used
162
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 129: LIU CHANNEL CONTROL STATUS REGISTER (LIUCCSR)
REV. V1.2.1
HEX ADDRESS: 0X0FN5
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
1
RLOS_n
RO
0
Receive Loss of Signal Defect Condition Status:
This READ-ONLY bit indicates whether or not the Receive LIU Block
is currently declaring the LOS defect condition.
0 = Indicates that the Receive Section is NOT currently declaring
the LOS Defect Condition.
1 = Indicates that the Receive Section is currently declaring the LOS
Defect condition.
NOTE: If the RLOSIE bit (bit D1 of Register 0x0Fn4) is enabled, any
transition on this bit will generate an Interrupt.
0
QRPD_n
RO
0
Quasi-random Pattern Detection Status:
This READ-ONLY bit indicates whether or not the Receive LIU Block
is currently declaring the QRSS Pattern LOCK status.
0 = Indicates that the XRT86VL38 is NOT currently declaring the
QRSS Pattern LOCK.
1 = Indicates that the XRT86VL38 is currently declaring the QRSS
Pattern LOCK.
NOTE: If the QRPDIE bit (bit D0 of register 0x0Fn4) is enabled, any
transition on this bit will generate an Interrupt.
NOTE: Register 0x0FN4, 0x0FN5 and 0x0FN6 only work if the LIU is placed in Single Rail mode. If done so, the Framer
block must also be placed in Single Rail mode in Register 0xn101.
163
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 130: LIU CHANNEL CONTROL INTERRUPT STATUS REGISTER (LIUCCISR)
BIT
FUNCTION
TYPE
DEFAULT
7
Reserved
RO
0
6
DMOIS_n
RUR/
WC
0
HEX ADDRESS: 0X0FN6
DESCRIPTION-OPERATION
Change of Transmit DMO (Drive Monitor Output) Condition
Interrupt Status:
This RESET-upon-READ bit indicates whether or not the “Change of
the Transmit DMO Condition” Interrupt has occurred since the last
read of this register.
0 = Indicates that the “Change of the Transmit DMO Condition”
Interrupt has NOT occurred since the last read of this register.
1 = Indicates that the “Change of the Transmit DMO Condition”
Interrupt has occurred since the last read of this register.
This bit is set to a “1” every time when DMO_n status bit (bit 6
of Register 0x0Fn5) has changed since the last read of this
register.
NOTE: Users can determine the current state of the “Transmit DMO
Condition” by reading out the content of bit 6 within Register
0x0Fn5
5
FLSIS_n
RUR/
WC
0
FIFO Limit Interrupt Status:
This RESET-upon-READ bit indicates whether or not the “FIFO
Limit” Interrupt has occurred since the last read of this register.
0 = Indicates that the “FIFO Limit Status” Interrupt has NOT
occurred since the last read of this register.
1 = Indicates that the “FIFO Limit Status” Interrupt has occurred
since the last read of this register.
This bit is set to a “1” every time when FIFO Limit Status bit
(bit 5 of Register 0x0Fn5) has changed since the last read of
this register.
NOTE: Users can determine the current state of the “FIFO Limit” by
reading out the content of bit 5 within Register 0x0Fn5
4
Reserved
-
-
This bit is not used
3
NLCDIS_n
RUR/
WC
0
Change in Network Loop-Code Detection Interrupt Status:
This RESET-upon-READ bit indicates whether or not the “Change in
Network Loop-Code Detection” Interrupt has occurred since the last
read of this register.
0 = Indicates that the “Change in Network Loop-Code Detection”
Interrupt has NOT occurred since the last read of this register.
1 = Indicates that the “Change in Network Loop-Code Detection”
Interrupt has occurred since the last read of this register.
This bit is set to a “1” every time when NLCD status bit (bit 3 of Register 0x0Fn5) has changed since the last read of this register.
NOTE: Users can determine the current state of the “Network LoopCode Detection” by reading out the content of bit 3 within
Register 0x0Fn5
2
Reserved
-
-
This bit is not used
164
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 130: LIU CHANNEL CONTROL INTERRUPT STATUS REGISTER (LIUCCISR)
REV. V1.2.1
HEX ADDRESS: 0X0FN6
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
1
RLOSIS_n
RUR/
WC
0
Change of Receive LOS (Loss of Signal) Defect Condition Interrupt Status:
This RESET-upon-READ bit indicates whether or not the “Change of
the Receive LOS Defect Condition” Interrupt has occurred since the
last read of this register.
0 = Indicates that the “Change of the Receive LOS Defect Condition” Interrupt has NOT occurred since the last read of this register.
1 - Indicates that the “Change of the Receive LOS Defect Condition”
Interrupt has occurred since the last read of this register.
NOTE: The user can determine the current state of the “Receive
LOS Defect condition” by reading out the contents of Bit 1
(Receive LOS Defect Condition Status) within Register
0xnFn5.
0
QRPDIS_n
RUR/
WC
0
Change in Quasi-Random Pattern Detection Interrupt Status:
This RESET-upon-READ bit indicates whether or not the “Change in
QRSS Pattern Detection” Interrupt has occurred since the last read
of this register.
0 = Indicates that the “Change in QRSS Pattern Detection” Interrupt
has NOT occurred since the last read of this register.
1 = Indicates that the “Change in QRSS Pattern Detection” Interrupt
has occurred since the last read of this register.
This bit is set to a “1” every time when QRPD status bit (bit 0 of Register 0x0Fn5) has changed since the last read of this register.
NOTE: Users can determine the current state of the “QRSS Pattern
Detection” by reading out the content of bit 0 within Register
0x0Fn5
NOTE: Register 0x0FN4, 0x0FN5 and 0x0FN6 only work if the LIU is placed in Single Rail mode. If done so, the Framer
block must also be placed in Single Rail mode in Register 0xn101.
165
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 131: LIU CHANNEL CONTROL CABLE LOSS REGISTER (LIUCCCCR)
BIT
FUNCTION
TYPE
DEFAULT
7
Reserved
RO
0
6
Reserved
RO
0
5-0
CLOS[5:0]
RO
0
DESCRIPTION-OPERATION
Cable Loss [5:0]:
These bits represent the six bit receive selective equalizer setting
which is also a binary word that represents the cable attenuation
indication within ±1dB.
CLOS5_n is the most significant bit (MSB) and CLOS0_n is the
least significant bit (LSB).
TABLE 132: LIU CHANNEL CONTROL ARBITRARY REGISTER 1 (LIUCCAR1)
BIT
FUNCTION
TYPE
DEFAULT
7
Reserved
R/W
0
6-0
Arb_Seg1
R/W
0
HEX ADDRESS: 0X0FN7
HEX ADDRESS: 0X0FN8
DESCRIPTION-OPERATION
Arbitrary Transmit Pulse Shape, Segment 1:
These seven bits form the first of the eight segments of the transmit
shape pulse when the XRT86VL38 is configured in “Arbitrary Mode”.
These seven bits represent the amplitude of the nth channel's arbitrary pulse in signed magnitude format with Bit 6 as the sign bit and
Bit 0 as the least significant bit (LSB).
NOTE: Arbitrary mode is enabled by writing to the EQC[4:0] bits in
register 0x0Fn0.
TABLE 133: LIU CHANNEL CONTROL ARBITRARY REGISTER 2 (LIUCCAR2)
BIT
FUNCTION
TYPE
DEFAULT
7
Reserved
R/W
0
6-0
Arb_Seg2
R/W
0
HEX ADDRESS: 0X0FN9
DESCRIPTION-OPERATION
Arbitrary Transmit Pulse Shape, Segment 2
These seven bits form the second of the eight segments of the
transmit shape pulse when the XRT86VL38 is configured in “Arbitrary Mode”.
These seven bits represent the amplitude of the nth channel's arbitrary pulse in signed magnitude format with Bit 6 as the sign bit and
Bit 0 as the least significant bit (LSB).
NOTE: Arbitrary mode is enabled by writing to the EQC[4:0] bits in
register 0x0Fn0.
166
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 134: LIU CHANNEL CONTROL ARBITRARY REGISTER 3 (LIUCCAR3)
BIT
FUNCTION
TYPE
DEFAULT
7
Reserved
R/W
0
6-0
Arb_seg3
R/W
0
REV. V1.2.1
HEX ADDRESS: 0X0FNA
DESCRIPTION-OPERATION
Arbitrary Transmit Pulse Shape, Segment 3
These seven bits form the third of the eight segments of the transmit
shape pulse when the XRT86VL38 is configured in “Arbitrary Mode”.
These seven bits represent the amplitude of the nth channel's arbitrary pulse in signed magnitude format with Bit 6 as the sign bit and
Bit 0 as the least significant bit (LSB).
NOTE: Arbitrary mode is enabled by writing to the EQC[4:0] bits in
register 0x0Fn0.
TABLE 135: LIU CHANNEL CONTROL ARBITRARY REGISTER 4 (LIUCCAR4)
BIT
FUNCTION
TYPE
DEFAULT
7
Reserved
R/W
0
6-0
Arb_seg4
R/W
0
DESCRIPTION-OPERATION
Arbitrary Transmit Pulse Shape, Segment 4
These seven bits form the forth of the eight segments of the transmit
shape pulse when the XRT86VL38 is configured in “Arbitrary Mode”.
These seven bits represent the amplitude of the nth channel's arbitrary pulse in signed magnitude format with Bit 6 as the sign bit and
Bit 0 as the least significant bit (LSB).
Arbitrary mode is enabled by writing to the EQC[4:0] bits in register
0x0Fn0.
TABLE 136: LIU CHANNEL CONTROL ARBITRARY REGISTER 5 (LIUCCAR5)
BIT
FUNCTION
TYPE
DEFAULT
7
Reserved
R/W
0
6-0
Arb_seg5
R/W
0
HEX ADDRESS: 0X0FNB
HEX ADDRESS: 0X0FNC
DESCRIPTION-OPERATION
Arbitrary Transmit Pulse Shape, Segment 5
These seven bits form the fifth of the eight segments of the transmit
shape pulse when the XRT86VL38 is configured in “Arbitrary Mode”.
These seven bits represent the amplitude of the nth channel's arbitrary pulse in signed magnitude format with Bit 6 as the sign bit and
Bit 0 as the least significant bit (LSB).
Arbitrary mode is enabled by writing to the EQC[4:0] bits in register
0x0Fn0.
167
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 137: LIU CHANNEL CONTROL ARBITRARY REGISTER 6 (LIUCCAR6)
BIT
FUNCTION
TYPE
DEFAULT
7
Reserved
R/W
0
6-0
Arb_seg6
R/W
0
DESCRIPTION-OPERATION
Arbitrary Transmit Pulse Shape, Segment 6
These seven bits form the sixth of the eight segments of the transmit
shape pulse when the XRT86VL38 is configured in “Arbitrary Mode”.
These seven bits represent the amplitude of the nth channel's arbitrary pulse in signed magnitude format with Bit 6 as the sign bit and
Bit 0 as the least significant bit (LSB).
Arbitrary mode is enabled by writing to the EQC[4:0] bits in register
0x0Fn0.
TABLE 138: LIU CHANNEL CONTROL ARBITRARY REGISTER 7 (LIUCCAR7)
BIT
FUNCTION
TYPE
DEFAULT
7
Reserved
R/W
0
6
Arb_seg7
R/W
0
FUNCTION
TYPE
DEFAULT
7
Reserved
R/W
0
6
Arb_seg8
R/W
0
HEX ADDRESS: 0X0FNE
DESCRIPTION-OPERATION
Arbitrary Transmit Pulse Shape, Segment 7
These seven bits form the seventh of the eight segments of the
transmit shape pulse when the XRT86VL38 is configured in “Arbitrary Mode”.
These seven bits represent the amplitude of the nth channel's arbitrary pulse in signed magnitude format with Bit 6 as the sign bit and
Bit 0 as the least significant bit (LSB).
Arbitrary mode is enabled by writing to the EQC[4:0] bits in register
0x0Fn0.
TABLE 139: LIU CHANNEL CONTROL ARBITRARY REGISTER 8 (LIUCCAR8)
BIT
HEX ADDRESS: 0X0FND
HEX ADDRESS: 0X0FNF
DESCRIPTION-OPERATION
Arbitrary Transmit Pulse Shape, Segment 8
These seven bits form the eight of the eight segments of the transmit shape pulse when the XRT86VL38 is configured in “Arbitrary
Mode”.
These seven bits represent the amplitude of the nth channel's arbitrary pulse in signed magnitude format with Bit 6 as the sign bit and
Bit 0 as the least significant bit (LSB).
Arbitrary mode is enabled by writing to the EQC[4:0] bits in register
0x0Fn0.
168
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 140: LIU GLOBAL CONTROL REGISTER 0 (LIUGCR0)
REV. V1.2.1
HEX ADDRESS: 0X0FE0
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
SR
R/W
0
Single Rail mode
This bit must set to "1" for Single Rail mode to use LIU diagnotic features. The Framer section must be programmed as well in Register
0xn101.
0 - Dual Rail
1 - Single Rail
6
ATAOS
R/W
0
Automatic Transmit All Ones Upon RLOS:
This bit enables automatic transmission of All Ones Pattern upon
detecting the Receive Loss of Signal (RLOS) condition.
Once this bit is enabled, the Transmit E1 Framer Block will automatically transmit an All “Ones” data to the line for the channel that
detects an RLOS condition.
0 = Disables the “Automatic Transmit All Ones” feature upon detecting RLOS
1 = Enables the “Automatic Transmit All Ones” feature upon detecting RLOS
5
RCLKE
R/W
0
Receive Clock Data (Framer Bypass mode)
0 = RPOS/RNEG data is updated on the rising edge of RCLK
1 = RPOS/RNEG data is updated on the falling edge of RCLK
4
TCLKE
R/W
0
Transmit Clock Data (Framer Bypass mode)
0 = TPOS/TNEG data is sampled on the falling edge of TCLK
1 = TPOS/TNEG data is sampled on the rising edge of TCLK
3
DATAP
R/W
0
Data Polarity
0 = Transmit input and receive output data is active “High”
1 = Transmit input and receive output data is active “Low”
2
Reserved
This Bit Is Not Used
169
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 140: LIU GLOBAL CONTROL REGISTER 0 (LIUGCR0)
HEX ADDRESS: 0X0FE0
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
1
GIE
R/W
0
Global Interrupt Enable:
This bit allows users to enable or disable the global interrupt generation for all channels within the E1 LIU Block. Once this global interrupt is disabled, no interrupt will be generated to the Microprocessor
Interrupt Pin even when the individual “source” interrupt status bit
pulses ‘high’.
If this global interrupt is enabled, users still need to enable the individual “source” interrupt in order for the E1 LIU Block to generate an
interrupt to the Microprocessor pin.
0 - Disables the global interrupt generation for all channels within
the E1 LIU Block.
1 - Enables the global interrupt generation for all channels within the
E1 LIU Block.
0
SRESET
R/W
0
Software Reset µP Registers:
This bit allows users to reset the XRT86VL38 device. Writing a “1” to
this bit and keeping it at ’1’ for longer than 10µs initiates a device
reset through the microprocessor interface. Once the XRT86VL38 is
reset, all internal circuits are placed in the reset state except the
microprocessor register bits.
0 = Disables software reset to the XRT86VL38 device.
1 = Enables software reset to the XRT86VL38 device.
TABLE 141: LIU GLOBAL CONTROL REGISTER 1 (LIUGCR1)
BIT
FUNCTION
TYPE
DEFAULT
7
Reserved
R/W
0
6
Reserved
R/W
0
5-4
Gauge [1:0]
R/W
00
HEX ADDRESS: 0X0FE1
DESCRIPTION-OPERATION
Wire Gauge Selector [1:0]:
This bit together with Guage0 bit (bit 4 within this register) are used
to select the wire gauge size as shown in the table below.
GAUGE1
GAUGE0
Wire Size
0
0
22 and 24 Gauge
0
1
22 Gauge
1
0
24 Gauge
1
1
26 Gauge
170
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 141: LIU GLOBAL CONTROL REGISTER 1 (LIUGCR1)
BIT
FUNCTION
3
E1 Arbitrary Enable
2
RXMUTE
TYPE
DEFAULT
REV. V1.2.1
HEX ADDRESS: 0X0FE1
DESCRIPTION-OPERATION
E1 Arbitrary Mode Enable
This bit is used to enable the Arbitrary Pulse Generators for shaping
the transmit pulse shape for E1 mode. If this bit is set to “1”, all 8
channels will be configured for the Arbitrary Mode. However, each
channel’s pulse shape is individually controlled by programming the
8 transmit pulse shape segments (channel registers 0x0Fn8 through
0x0FnF)
“0” = Disabled (Normal E1 Pulse Shape ITU G.703)
“1” = Arbitrary Pulse Enabled
R/W
0
Receive Output Mute:
This bit permits the user to configure the Receive E1 Block to automatically pull its Recovered Data Output pins to GND anytime (and
for the duration that) the Receive E1 LIU Block declares the LOS
defect condition.
In other words, if this feature is enabled, the Receive E1 LIU Block
will automatically “mute” the Recovered data that is being routed to
the Receive E1 Framer block anytime (and for the duration that) the
Receive E1 LIU Block declares the LOS defect condition.
0 – Disables the “Muting upon LOS” feature.
1 – Enables the “Muting upon LOS” feature.
NOTE: The receive clock is not muted when this feature is enabled.
1
EXLOS
0
ICT
Extended LOS Enable:
This bit allows users to extend the number of zeros at the receive
input of each channel before RLOS is declared.
When Extended LOS is enabled, the Receive E1 LIU Block will
declare RLOS condition when it receives 4096 number of consecutive zeros at the receive input.
When Extended LOS is disabled, the Receive E1 LIU Block will
declare RLOS condition when it receives 175 number of consecutive zeros at the receive input.
0 = Disables the Extended LOS Feature.
1 = Enables the Extended LOS Feature.
R/W
0
In-Circuit-Testing Enable:
This bit allows users to tristate the output pins of all channels for incircuit testing purposes.
When In-Circuit-Testing is enabled, all output pins of the
XRT86VL38 are “Tri-stated”. When In-Circuit-Testing is disabled, all
output pins will resume to normal condition.
0 = Disables the In-Circuit-Testing Feature.
1 = Enables the In-Circuit-Testing Feature.
171
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 142: LIU GLOBAL CONTROL REGISTER 2 (LIUGCR2)
HEX ADDRESS: 0X0FE2
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
Force to "0"
R/W
0
Set to "0"
6
RxTCNTL
R/W
0
Receive Termination Select Control
This bit sets the LIU to control the RxTSEL function with either the
individual channel register bit or the global hardware pin.
0 = Control of the receive termination is set to the register bits
1 = Control of the receive termination is set to the hardware pin
5-0
Reserved
R/W
0
This Bit Is Not Used
TABLE 143: LIU GLOBAL CONTROL REGISTER 3 (LIUGCR3)
HEX ADDRESS: 0X0FE4
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
7-6
MCLKnT1[1:0]
R/W
00
Master T1 Output Clock Reference [1:0]
These two bits allow users to select the programmable output clock
rates for the T1MCLKnOUT pin, according to the table below.
5-4
3-0
MCLKnE1[1:0]
Reserved
R/W
R/W
00
0
MCLKNT1[1:0]
CLOCK RATE OF THE T1MCLKNOUT
OUTPUT PIN
00
1.544MHz
01
3.088MHz
10
6.176MHz
11
12.352MHz
Master E1 Output Clock Reference [1:0]:
These two bits allow users to select the programmable output clock
rates for the E1MCLKnOUT pin, according to the table below:
MCLKNE1[1:0]
CLOCK RATE OF THE E1MCLKNOUT
OUTPUT PIN
00
2.048MHz
01
4.096MHz
10
8.192MHz
11
16.384MHz
This Bit Is Not Used.
172
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 144: LIU GLOBAL CONTROL REGISTER 4 (LIUGCR4)
BIT
FUNCTION
TYPE
DEFAULT
7-4
Reserved
R/W
0
3-0
CLKSEL[3:0]
R/W
1100
HEX ADDRESS: 0X0FE9
DESCRIPTION-OPERATION
Clock Select Input [3:0]
These four bits allow users to select the programmable input clock
rates for the MCLKIN input pin, according to the table below.
CLKSEL[3:0]
CLOCK RATE OF THE MCLKIN
INPUT PIN
0000
2.048MHz
0001
1.544MHz
0010
8kHz
0011
16kHz
0100
56kHz
0101
64kHz
0110
128kHz
0111
256kHz
1000
4.096MHz
1001
3.088MHz
1010
8.192MHz
1011
6.176MHz
1100
16.384MHz
1101
12.352MH
1110
2.048MHz
1111
1.544MHz
NOTE: User must provide any one of the above clock frequencies to
the MCLKIN input pin for the device to be functional.
173
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
TABLE 145: LIU GLOBAL CONTROL REGISTER 5 (LIUGCR5)
HEX ADDRESS: 0X0FEA
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
7
GCHIS7
RUR/
WC
0
Global Channel 7 Interrupt Status Indicator
This Reset-Upon-Read bit field indicates whether or not an interrupt
has occurred on Channel 7 within the XRT86VL38 device since the
last read of this register.
0 = Indicates that No interrupt has occurred on Channel 7 within the
XRT86VL38 device since the last read of this register.
1 = Indicates that an interrupt has occurred on Channel 7 within the
XRT86VL38 device since the last read of this register.
6
GCHIS6
RUR/
WC
0
Global Channel 6 Interrupt Status Indicator
This Reset-Upon-Read bit field indicates whether or not an interrupt
has occurred on Channel 6 within the XRT86VL38 device since the
last read of this register.
0 = Indicates that No interrupt has occurred on Channel 6 within the
XRT86VL38 device since the last read of this register.
1 = Indicates that an interrupt has occurred on Channel 6 within the
XRT86VL38 device since the last read of this register.
5
GCHIS5
RUR/
WC
0
Global Channel 5 Interrupt Status Indicator
This Reset-Upon-Read bit field indicates whether or not an interrupt
has occurred on Channel 5 within the XRT86VL38 device since the
last read of this register.
0 = Indicates that No interrupt has occurred on Channel 5 within the
XRT86VL38 device since the last read of this register.
1 = Indicates that an interrupt has occurred on Channel 5 within the
XRT86VL38 device since the last read of this register.
4
GCHIS4
RUR/
WC
0
Global Channel 4 Interrupt Status Indicator
This Reset-Upon-Read bit field indicates whether or not an interrupt
has occurred on Channel 4 within the XRT86VL38 device since the
last read of this register.
0 = Indicates that No interrupt has occurred on Channel 4 within the
XRT86VL38 device since the last read of this register.
1 = Indicates that an interrupt has occurred on Channel 4 within the
XRT86VL38 device since the last read of this register.
3
GCHIS3
RUR/
WC
0
Global Channel 3 Interrupt Status Indicator
This Reset-Upon-Read bit field indicates whether or not an interrupt
has occurred on Channel 3 within the XRT86VL38 device since the
last read of this register.
0 = Indicates that No interrupt has occurred on Channel 3 within the
XRT86VL38 device since the last read of this register.
1 = Indicates that an interrupt has occurred on Channel 3 within the
XRT86VL38 device since the last read of this register.
174
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
TABLE 145: LIU GLOBAL CONTROL REGISTER 5 (LIUGCR5)
REV. V1.2.1
HEX ADDRESS: 0X0FEA
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
2
GCHIS2
RUR/
WC
0
Global Channel 2 Interrupt Status Indicator
This Reset-Upon-Read bit field indicates whether or not an interrupt
has occurred on Channel 2 within the XRT86VL38 device since the
last read of this register.
0 = Indicates that No interrupt has occurred on Channel 2 within the
XRT86VL38 device since the last read of this register.
1 = Indicates that an interrupt has occurred on Channel 2 within the
XRT86VL38 device since the last read of this register.
1
GCHIS1
RUR/
WC
0
Global Channel 1 Interrupt Status Indicator
This Reset-Upon-Read bit field indicates whether or not an interrupt
has occurred on Channel 1 within the XRT86VL38 device since the
last read of this register.
0 = Indicates that No interrupt has occurred on Channel 1 within the
XRT86VL38 device since the last read of this register.
1 = Indicates that an interrupt has occurred on Channel 1 within the
XRT86VL38 device since the last read of this register.
0
GCHIS0
RUR/
WC
0
Global Channel 0 Interrupt Status Indicator
This Reset-Upon-Read bit field indicates whether or not an interrupt
has occurred on Channel 0 within the XRT86VL38 device since the
last read of this register.
0 = Indicates that No interrupt has occurred on Channel 0 within the
XRT86VL38 device since the last read of this register.
1 = Indicates that an interrupt has occurred on Channel 0 within the
XRT86VL38 device since the last read of this register.
175
XRT86VL38
REV. V1.2.1
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
ORDERING INFORMATION
PRODUCT NUMBER
PACKAGE
OPERATING TEMPERATURE RANGE
XRT86VL38IB
420 Plastic Ball Grid Array
-40°C to +85°C
XRT86VL38IB484
484 Shrink Thin Ball Grid Array
-40°C to +85°C
PACKAGE DIMENSIONS FOR 420 PLASTIC BALL GRID ARRAY
E
420 Plastic Ball Grid Array
(35.0 mm x 35.0 mm, PBGA)
Rev. 1.00
Note: The control dimension is in millimeter.
SYMBOL
A
A1
A2
A3
D
D1
E
E1
b
e
INCHES
MIN
MAX
0.085
0.098
0.020
0.028
0.020
0.024
0.045
0.047
1.370
1.386
1.2500 BSC
1.370
1.386
1.2500 BSC
0.024
0.035
0.0500 BSC
176
MILLIMETERS
MIN
MAX
2.16
2.50
0.50
0.70
0.51
0.61
1.15
1.19
34.80
35.20
31.75 BSC
34.80
35.20
31.75 BSC
0.60
0.90
1.27 TYP.
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
PACKAGE DIMENSIONS FOR 484 SHRINK THIN BALL GRID ARRAY
4
E
484 Shrink Thin Ball Grid Array
(23.0 mm x 23.0 mm, STBGA)
Rev. 1.00
Note: The control dimension is in millimeter.
SYMBOL
A
A1
A2
A3
D
D1
E
E1
b
e
INCHES
MIN
MAX
0.071
0.082
0.019
0.022
0.019
0.022
0.033
0.037
0.898
0.913
0.8268 BSC
0.898
0.913
0.8268 BSC
0.024
0.028
0.0394 BSC
177
MILLIMETERS
MIN
MAX
1.80
2.08
0.47
0.57
0.48
0.56
0.85
0.95
22.80
23.20
21.00 BSC
22.80
23.20
21.00 BSC
0.60
0.70
1.00 BSC
REV. V1.2.1
XRT86VL38
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
P4.
REVISION HISTORY
REVISION #
V1.2.0
V1.2.1
DATE
DESCRIPTION
January 25, 2007 Released to Production.
April 2007
Added registers 0xnB10, B11, B18, B19, B28 & B29
NOTICE
EXAR Corporation reserves the right to make changes to the products contained in this publication in order to
improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any
circuits described herein, conveys no license under any patent or other right, and makes no representation that
the circuits are free of patent infringement. Charts and schedules contained here in are only for illustration
purposes and may vary depending upon a user’s specific application. While the information in this publication
has been carefully checked; no responsibility, however, is assumed for inaccuracies.
EXAR Corporation does not recommend the use of any of its products in life support applications where the
failure or malfunction of the product can reasonably be expected to cause failure of the life support system or
to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless
EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has
been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR Corporation is adequately
protected under the circumstances.
Copyright 2007 EXAR Corporation
Datasheet April 2007.
Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited.
178