FILTRAN 7088

Power
500 kHz Current Sense Transformers
7086-7088
• Frequency range from 200 to 500 kHz
• 20 Amp peak sense current
• 1500 Vrms isolation
MECHANICAL AND SCHEMATIC
(All dimensions in inches)
.380 Max
SCHEMATIC
3
.595 Max
1
1 Turn
708X
FD/C
N T Turns
4
2
.120 - .155
4
.150
.150
3
2
1
.325 Max
.100
.400
.550 Max
UNLESS OTHERWISE SPECIFIED, ALL TOLERANCES ARE ±0.010
ISSUE: A
09/04/03
7086-88
ELECTRICAL SPECIFICATION @ 25˚C
Secondary
Turns 2
NT
Secondary
Inductance3
(µH Min)
DCR
Secondary
(Ω Max)
DCR
Pri mary
(Ω)
VS
(mV)
1.50
10
150
.055
.006
30
3.00
20
600
.097
.006
60
7.50
50
4000
.240
.006
160
Part
Number
RT 1
(Ω)
7086
7087
7088
1. Terminating resistance for .15 Volt/Amp
2. ± 1 turn
3. Measured @ 100 kHz, @ VS
229 Colonnade Road, Ottawa, Ontario, Canada K2E 7K3
Tel: (613) 226-1626 Fax: (613) 226-7124 www.filtran.com
An ISO 9001 Registered Company