FILTRAN 7325

LAN
Isolation Transformers for 10 Base-T
7325-7329
• Available with common mode chokes for EMI suppression
• Exceeds IEEE 802.3, 10 Base-T specifications
• Isolation voltage 2000 Vrms
MECHANICAL AND SCHEMATIC
(All dimensions in inches)
SUGGESTED PAD LAYOUT
SCHEMATIC 1
SCHEMATIC 2
UNLESS OTHERWISE SPECIFIED, ALL TOLERANCES ARE ±0.005
ISSUE: B
06/05/02
7325-7329
ELECTRICAL SPECIFICATION @ 25˚C
Part
Number
Turns Ratio
(±5%)
Primary
Pins
Common
Mode
Choke
Sine Wave
CW/W1
OCL1
(pF MAX)
(µH MIN)
L L1
(µH MAX)
DCR
(Ω MAX)
Schem.
Transmit
Receive
7325
1CT:1CT
1CT:1CT
1-3 / 6-8
200
12
0.3
0.3
7326
1CT: √2CT
1CT:1CT
6-8 / 1-3
200
15
0.5
0.4
1
7327
2CT:1CT
1CT:1CT
1-3 / 6-8
100
10
0.4
0.5
1
7328
1CT: √2CT
1CT:1CT
6-8 / 1-3
X
200
12
0.5
0.6
2
7329
1CT:2CT
1CT:1CT
6-8 / 1-3
X
140
12
0.2
0.6
2
1. OCL, CW/W and LL are measured at 20 mVrms, 100 kHz.
229 Colonnade Road, Ottawa, Ontario, Canada K2E 7K3
Tel: (613) 226-1626 Fax: (613) 226-7124 www.filtran.com
An ISO 9001 Registered Company
1