FILTRAN TEP5606

ISDN
TEP5606
DC/DC Converter Transformer
TEP5606 is designed and approved to be used as a power
supply transformer with the
Siliconix SI 9105 device.
Features:
TEP5606 meets the CCITT I.430
requirements with reference to
various modes of operation.
•
Compact size
•
Efficient
•
Reinforced insulation
(TEP5606-1) in accordance
with IEC950, EN60950
MECHANICAL
L
H
4
7
3
5
2
8
1
6
C
B
DOT AT
PIN #1
1
S
2
3
4
DIMENSIONS, Inches (mm)
A
8
7
6
W
5606.chp
96/08/07
Issue: B
Output Voltage
(3 - 4)
(5 - 7) & (6 - 8)
Output Current
Turns Ratio
(3-4) : (1-2) : (5-7) : (6-8)
Inductance
(3 - 4)
Dielectric Strength
Filtran Limited
L
TEP5606
5
ELECTRICAL SPECIFICATIONS
Input Voltage
P/N
W
H
A
B
C
S
0.87 0.83 0.63 0.60 0.20 0.12
0.025
(22.0) (21.0) (16.0) (15.3) (5.1) (3.0)
(0.64)
TEP5606
TEP5606-1
24 - 50 V
24 - 50 V
2x5V
2x5V
3 - 200 mA
3 - 200 mA
4.52 : 1.9 :1 :1
4.52 : 1.9 :1 :1
> 3.3 mH
> 3.3 mH
1500 V
4000 V
229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3
Tel : (613) 226-1626 Fax : (613) 226-7124
3-12