FILTRAN TEW5039

ISDN
TEW5039
U-BUS/DNIC Input/Output Transformer
TEW5039 is designed to interface with the subscribers premises (NT) and the 2- wire line
side of the Central Office Equipment (LT) in the ISDN Network.
Applications:
•
Up to 50 mA line current.
•
TEW5039 meets the
requirements of BS6301 for
reinforced insulation,
clearance and creepage
distances between the line
and the device side.
•
TEW5039-1 meets the
requirements for pollution
class 2.
TEW5039 meets the electrical requirements for the
Mitel MT8972 & MT8971B/72B
devices.
Certified to EN60950 and
EN41003.
MECHANICAL
1
6
2
LINE
DEVICE
7
3
4
DOT AT
PIN #1
DIMENSIONS, Inches (mm)
P/N
Issue; B
94/12/14
TEW5039.chp
TEW5039
ELECTRICAL
Line Impedance
Inductance
Leakage Inductance
Winding Resistance
(6-7)
(6-7)
(1-2) & (3-4)
(6-7)
Turns Ratio
(6-7) : (1-2) : (3-4)
DC Capability (Line Side)
(1-4)
Dielectric Strength
Filtran Limited
L
W
H
A
B
C
S
0.87 0.83 0.63 0.60 0.20 0.12
0.025
(22.0) (21.0) (16.0)(15.3) (5.1) (3.0)
(0.64)
TEW5039
TEW5039-1
135 Ω
> 30mH
< 95 µH
1.5 Ω ea
5.5 Ω
4:1:1
50 mA
4000 V rms
135 Ω
> 30 mH
< 95 µH
3.4 Ω ea
6.7 Ω
4:1:1
50 mA
4000V rms
229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3
Tel : (613) 226-1626 Fax : (613) 226-7124