FILTRAN TEW4087

LAN
TEW4087
Matching Transformer
SCOPE
The TEW4087 transformer was
designed to provide matching
between a coax cable and a
twisted pair.
It is based on the Ethernet data
link protocol which uses baseband signaling at 10Mbps.
MECHANICAL
0.40
2
0.40
ALL DIMENSIONS
ARE IN INCHES
0.10
1
5
6
3
4
DIA O.025
0.30
6 5 4
DRILL O.O40
6 PLACES
1 2 3
GRID 0.10 x 0.10
WHITE DOT
93/02/05
TEW4087
ELECTRICAL
Inductance
each winding
500 µH min
Leakage Inductance
1-6 with 2,3,4,5 shorted
0.5 µH max
Winding Resistance
each winding
0.7 Ω max
Issue:B
Interwinding Capacitance
Turns Ratio
Dielectric Strength
Filtran Limited
90 pf max
1:1:1
500V rms
229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3
Tel : (613) 226 1626 Fax : (613) 226 7124
5-3