GENNUM EB9035

GENLINX™ II
EB9035 Evaluation Board
PRELIMINARY
INTRODUCTION
360Mb/s, and 540Mb/s. LED indicators are used to indicate
when the device is LOCKed and the detected data rate as
shown below.
The EB9035 is an evaluation and reference design platform
for the GENLINX™ II GS9035 Reclocker and the GS9028
Cable Driver.
143Mb/s
177Mb/s
270Mb/s
360Mb/s
540Mb/s
CIRCUIT DESCRIPTION
A functional block diagram is shown below and illustrates
the primary circuit functions. These include reclocking and
driving 75Ω co-axial cables. A complete schematic is also
included.
SS1
0
0
1
1
0
SS0
0
1
0
1
0
The GS9035 can also be configured for manual mode by
first putting the AUTO/MANUAL jumper (JMP1) into the 23 position. Then jumpers JMP[7:5] are set accordingly.
The EB9035 accepts differential serial digital data input
signals which go into the GS9035 reclocker. The reclocker
then generates clock and retimed data signals. In
addition, the complementary serial clock output signals
are available at BNC connectors J2 and J3. The GS9035
also drives data rate indication LEDs and a LOCK LED
which is provided to visually indicate when the reclocker
has locked to the incoming video signal.
Note that whenever the AUTO/MANUAL input of the GS9035
is HIGH (auto mode), jumpers JMP[7:5] should be left
floating to avoid bus contention.
To verify operation of the EB9035, a differential source of
serial digital video should be applied to the input BNC
connectors using 75Ω co-axial cable. A convenient differential source is available from the EB9024 evaluation
board. The output data stream is available at the serial
output and can be supplied to a D to A converter for
verification via a monitor. Note that the jumpers should be
set as shown below for an output to be present:
The reclocked data signals are then supplied to the
GS9028 cable driver which provides two complementary
data outputs at BNC connectors J4 and J5. The GS9028
is configured to drive 75Ω co-axial cables with SMPTE
defined 800mV levels.
BOARD SET-UP AND TEST
JMP1: 1-2 (reclocker configured for AUTO mode)
JMP2: 1-2 (reclocker configured for SMPTE mode)
The board is configured in SMPTE, auto-tune mode and
supports five data rates: 143Mb/s, 177Mb/s, 270Mb/s,
DIFFERENTIAL
SERIAL DATA
INPUTS
SS2
0
0
0
0
1
GS9028
CABLE
DRIVER
GS9035
RECLOCKER
SERIAL
DATA
OUTPUTS
SERIAL
CLOCK
OUTPUTS
EB9035 BLOCK DIAGRAM
Document No. VB2931 -1
1
The power supply requirement for the EB9035 is +5V for
VCC at a current rating of 170mA (nominally).
PCB DETAILS
The EB9035 is a four layer printed circuit board constructed
of standard FR-4 material and measures approximately 4.5"
by 4.5". Ground and power plane layers are internal to the
board with signal layers on the top and bottom of the board.
Components are mounted both on the top and bottom sides.
The silkscreen (top and bottom) and all four layers are shown
on the following pages. Note the following special artwork
features used to optimize performance:
- A continuous ground plane is provided underneath all high
speed traces avoiding impedance discontinuities and ensuring maximum signal integrity
- Copper on the power and ground planes has been removed from the area surrounding the center pin of the output
BNC connectors and from underneath the output components of the GS9028 cable driver. The purpose of these
cutouts is to reduce the effect of the capacitance added by
the connector and the pads of the components.
- Copper on the power and ground planes has been removed from underneath the loop filter and RVCO components of the GS9035. The purpose of these cutouts is to avoid
any noise coupling from the planes into the GS9035.
APPLICATIONS
The EB9035 evaluation board is designed to show the
characteristics of the GS9035 Reclocker and the GS9028
Cable Driver.
CAUTION
ELECTROSTATIC
SENSITIVE DEVICES
DO NOT OPEN PACKAGES OR HANDLE
EXCEPT AT A STATIC-FREE
Gennum Corporation assumes no responsibility for the use of any circuits described herein and makes no representations that they are free from patent infringement.
Please be advised that this preliminary document does not conform to Gennum's ISO9001 standards.
© Copyright March 1998 Gennum Corporation. All rights reserved. Printed in Canada.
VB2931 - 1
2
3
VB2931 - 1
VB2931 - 1
4
5
VB2931 - 1
VB2931 - 1
6
7
VB2931 - 1
VB2931 - 1
8
9
VB2931 - 1