HUMIREL HM1520LF

RELATIVE HUMIDITY MODULE
HM1520LF
Compliant with RoHS recommendations
Based on the rugged HS1101LF capacitive humidity sensor, HM1520LF is a dedicated humidity transducer
designed for measurements at low humidity. Direct measurement of dew point or water concentration can be
easily obtained in really cost effective conditions. Direct interface with a micro-controller is made possible with the
module’s linear voltage output.
MAIN FEATURES
Tubular form for through wall mounting
Product free from Lead, Cr(6+), Cd and Hg
Not affected by water condensation
Full interchangeability
Typical 1 to 1.6 Volt DC output for 0 to 20% RH at 5 V DC supply
Calibrated, linear voltage for easy electronic interface
Controlled temperature dependency
Ratiometric to voltage supply
HUMIDITY SENSOR SPECIFIC FEATURES
No affected by long period at low humidity values
Patented solid polymer structure
High resistance to chemical
Fast response time
MAXIMUM RATINGS
Ratings
Symbol
Value
Unit
Tstg
-30 to 70
°C
RHstg
0 to 100
% RH
Supply Voltage (Peak)
Vs
10
Vdc
Humidity Operating Range
RH
0 to 100
% RH
Temperature Operating Range
Ta
-40 to 60
°C
Storage Temperature
Storage Humidity Range
Accuracy of HM1520LF when used from 1 to 95%RH
HPC091 Rev A January 2008
TECHNICAL 1 DATA
HM1520LF
CHARACTERISTICS
( Vs=5.0Vdc, RL >1MΩ unless otherwise stated)
Characteristics
Symbol
Min
RH
0
Humidity measuring range / Ta –40 to 60°C
Typ
Relative Humidity Accuracy (1-20%) at 23°C
±2
Relative Humidity Accuracy at 55% RH at 23°C
±5
Max
Unit
100
%RH
±3
%RH
%RH
Voltage Supply (regulated at 5Vdc)*
Vcc
4.75
5
5.25
Vdc
Nominal Output @10%RH /Ta 25°C
Vout
1.17
1.24
1.31
V
Current Consumption
Icc
2.8
4
mA
Temperature coefficient (10 to 50°C and 1 to 20%RH)
Tcc
-0.05
-0.1
%RH/°C
ΔmV/RH
+26
Humidity Average Sensitivity from 5% to 10% RH
Response time ( at 63% of signal) from 5% to 10% RH
τ
Humidity Hysteresis
Output impedance
Z
Sink current capability (RL = 33 kOhms)
Is
Warm up time (electronic)
tw
mV/%RH
10
s
+/-1
%RH
Ω
70
150
µA
150
ms
Humidity Resolution
0.4
%RH
Long Term Stability
0.5
%RH/Yr
*Maximal power supply ramp up time to VCC should be less than 4 ms.
HM1520LF Preliminary Specification when used from 1 to 30%RH
Those equations can be used above 30% RH and allow to obtain an over all accuracy as described
in page one of this document in all the humidity measuring range
Temperature (in the range 0 to 50°C) does not affect HM1520LF measurement when used from 1 to
30% RH. No temperature compensation is required.
HPC091 Rev A January 2008
TECHNICAL 2 DATA
HM1520LF
Signal output from 1 to 20% RH at 23°C :
RH(%)
Vout(mV)
RH(%)
Vout(mV)
1
2
3
4
5
6
7
8
9
10
1013 1038 1064 1089 1115 1141 1166 1192 1217 1243
11
12
13
14
15
16
17
18
19
20
1269 1294 1320 1346 1371 1397 1422 1448 1474 1499
With Vs = 5.0 Volts DC
Calibration data are traceable to NIST standards through CETIAT laboratory.
IMPORTANT NOTICE :
HM1520LF is based on HS1101LF capacitive sensor and thus
is fully useable on a large range of relative humidity ( 1 to 99% RH). In that range,
HM1520LF presents a typical accuracy of +/-5% RH at 55% RH.)
However HM1520LF is a dedicated module for humidity measurements at low Relative Humidity
levels.
Thus, HM1520LF is also well adapted to measure water concentrations (ppm) or low dew
points when associated with an ambient temperature probe.
HM1520LF features an optimized accuracy for water concentration below 6000 ppm water or
0°C dew point at 23°C (equivalent to 20% RH).
TYPICAL OUTPUT of HM1520LF when measuring
water concentration at ambient temperature of 23°C :
ppm
Vout(mV)
ppm
Vout(mV)
275
1013
3025
1269
550
1038
3300
1294
825
1064
3570
1320
1100
1089
3850
1346
1375
1115
4120
1371
1650
1141
4395
1397
1925
1166
4670
1422
2200
1192
4945
1448
2470
1217
5220
1474
2750
1243
5495
1499
ppmwater = 10.75 Vout - -10615 with Vout in mVolts
TYPICAL OUTPUT of HM1520LF when measuring
dew point at ambient temperature of 23°C :
°C
Vout(mV)
°C
Vout(mV)
-36 -29 -24 -21
1013 1038 1064 1089
-9
-7.8 -6.8 -5.8
1269 1294 1320 1346
HPC091 Rev A January 2008
-18.5 -16 -14.5 -13
1115 1141 1166 1192
-4.9 -4.1 -3.2 -2.5
1371 1397 1422 1448
TECHNICAL 3 DATA
-11.5 -10
1217 1243
-1.6 -1.1
1474 1499
HM1520LF
RESISTANCE TO PHYSICAL AND CHEMICAL STRESS
- HM1520LF has passed through qualification processes of HUMIREL including vibration, shock, storage, high
temperature and humidity, ESD.
- Additional tests under harsh chemical conditions demonstrate good operation in presence of salt atmosphere,
SO2(O.5%), H2S (0.5%), O3, NOx, NO, CO, CO2, Softener, Soap, Toluene, acids (H2SO4, HNO3, HCl), HMDS,
Insecticide, Cigarette smoke, a non exhaustive list.
- HM152000LF is not light sensitive.
SPECIFIC PRECAUTIONS
- HM1520LF is protected against reversed polarity.
- If you wish to use HM1520LF in a chemical atmosphere not listed above, consult us.
PACKAGE OUTLINE
* Specific length available on request
Dim
Min (mm)
Max (mm)
A
9.75
10.25
B
4.00
4.50
C
53
55
D
10.9
11.4
E*
200
250
Wire
Color
Function
W1
White
GROUND
W2
Blue
W3
Yellow
SUPPLY
VOLTAGE
OUTPUT
VOLTAGE
ORDERING INFORMATION (MULTIPLE PACKAGE QUANTITY OF 10 PARTS)
HM1520LF: HUMIDITY ANALOG VOLTAGE OUTPUT MODULE
ORDERING REFERENCE: HPP805C031
SAMPLE KIT OF HM1520LF
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsability is assumed for inaccuracies. Furthermore, this information does not
conveyto the purchaser of such devices any license under the patent rights to the manufacturer. Humirel reserves the right to make changes without further notice to any product herein.
Humirelmakes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Humirel assume any liability arising out of the application
or useof any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. « Typical » parameters can and do vary in
differentapplications. All operating parameters, including « Typical » must be validated for each customer applications by customer’s technical experts. Humirel does not convey any license
under itspatent rights nor the rights of others. Humirel products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or
other appli-cation intended to support or sustain life, or for any application in which the failure of the Humirel product could create a situation where personal injury or death may occur.
Should buyerpurchase or use Humirel products for any such unintended or unauthorized application, Buyer shall indemnify and hold Humirel and its officers, employees, subsidaries,
affiliates and distribu-tors harmless against all claims, costs, damages and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of presonal injury or death
associated with such unin-tended or unauthorized use, even if such claim alleges that Humirel was negligent regarding the design or manufacture of the part.Humirel is a registred trade mark
of Humirel.
HPC091 Rev A January 2008
TECHNICAL 4 DATA
HM1520LF