HUMIREL HPP808G031

TECHNICAL
TEMPERATURE AND HUMIDITY MODULE
1 DATA
HTF3226LF
Meets RoHS regulations
Based on the rugged HS1101LF humidity sensor, HTF3226LF is a dedicated humidity and
temperature transducer designed for OEM applications where a reliable and accurate measurement is
needed. It features a miniature connector for easy, cost-effective mechanical mounting. Direct interface
with a micro-controller is made possible with the module’s linear frequency output.
MAIN FEATURES
●
●
●
●
●
●
The best combination of cost effectiveness and performance
Stable, linear proportional frequency output from 10 to 95% RH.
Calibrated within +/- 5% RH @ 55% RH.
10 kohm +/- 3% NTC temperature sensor (1% optional)
Stable and reproducible characteristics with temperature.
High reliability and long term stability.
HUMIDITY SENSOR SPECIFIC FEATURES
●
●
●
●
●
Instantaneous de-saturation after long periods in saturation phase.
Fast response time.
High resistance to chemicals.
Not affected by water immersion.
Patented solid polymer structure.
TEMPERATURE SENSOR SPECIFIC FEATURES
● High quality thermistor
● Stable
● High sensitivity
MAXIMUM RATINGS
Ratings
Symbol
Value
Unit
Tstg
-40 to 85
°C
RHstg
0 to 100
% RH
Supply Voltage (Peak)
Vs
7
Vdc
Humidity Operating Range
RH
0 to 99
% RH
Storage Temperature
Storage Humidity Range
Temperature Operating Range Ta
-30 to 85
°C
CHARACTERISTICS
Humidity sensor
(Ta = 25°C, Vs = 5.0 Vdc +/- 5%, RL > 100 KΩ unless otherwise stated)
Characteristics
Symbol
Min.
Humidity metrology range
RH
1
Relative Humidity accuracy (10 to 95 % RH)
RH
Voltage supply
Vs
Fout
Nominal output @ RH = 55 %
Current consumption
Ic
Temperature coefficient (0 to 60 °C )
Tcc
Averaged Sensitivity from 33 % to 75 % RH
Condensing conditions output (100% RH)
Recovery time after 150 hours of condensation
∆Fout /∆ RH
Fout
t
Typ.
% RH
+/- 5
+/- 10
% RH
4.75
5.0
5.25
VdC
8670
8750
8830
Hz
0.1
mA
- 0.2
-13
- 14
8000
% RH/°C
-16
Hz/% RH
8300
Hz
10
s
+/-1
Long term stability
Unit.
99
Humidity Hysteresis
Time constant (33 to 76% RH, static, @63 %)
Max.
% RH
% RH/yr
+/-0.5
τ
10
s
Humirel Sensor Device Data / HPC053 RevD June 2005
TECHNICAL
2 DATA
Maximum error in % RH
Relative Humidity Accuracy of HTF 3226LF
Relative Humidity in %
Modeled Signal output (Linear Reference curve) : Fout = 9595 - 14.8*RH with Fout in Hz and RH in %
Modeled Signal output (Second order curve) : Fout = 9659 - 18.79*RH + 0.0404*RH 2
Typical response look-up table
RH (%)
0
5
Fout (Hz)
10
15
20
25
30
35
40
45
50
9490
9390
9295
9205
9125
9040
8965
8890
8820
100
RH (%)
55
60
65
70
75
80
85
90
95
Fout (Hz)
8750
8680
8615
8550
8485
8420
8355
8290
8225
Fout in Hz
Typical , Minimum and Maximum Frequency Values for HTF3226LF
Relative Humidity in %
Calibration data are traceable to NIST standards through CETIAT laboratory.
Humirel Sensor Device Data / HPC053 RevD June 2005
TECHNICAL
3 DATA
CHARACTERISTICS
Temperature sensor
(Ta = 25°C)
Characteristics
Symbol
Min.
Typ.
Nominal resistance @ 25°C
Max.
Unit.
10
kΩ
Beta value : B25/100
B
3600
3730
3800
Temperature measuring range
Ta
- 30
Nominal Resistance Tolerance
Rn
B value tolerance
B
3
%
Response Time
τ
10
s
2
80
°C
3
%
Typical temperature output
Depending on the needed temperature measurement range
and associated accuracy, we suggest two methods to access to
the NTC resistance values.
1
The actual characteristic of an NTC thermistor can, however, only
be roughly described by the exponential relation,as the material
parame ter B in reality also depends on temperature. So this
approach is only suitable for describing a restricted range around
the rated temperature or resistance with sufficient accuracy.
NTC resistance in Ωat temperature T in K
NTC resistance in Ωat rated temperature in K
Temperature in K
B value,material-specific constant of the NTC thermistor
Base of natural logarithm (e =2.71828)
Temperature
°C
-30
-29
-28
-27
-26
-25
-24
-23
-22
-21
-20
-19
-18
-17
-16
-15
-14
-13
-12
-11
-10
-9
-8
-7
-6
-5
-4
-3
Resistance
(ohm)
144790
136664
129054
121925
115243
109030
103115
97565
92354
87460
82923
78581
74497
70655
67039
63591
60381
57356
54503
51813
49204
46767
44467
42296
40247
38279
36455
34731
Max.
Deviation
16636
15444
14343
13325
12383
11516
10705
9953
9257
8612
8020
7463
6947
6468
6023
5606
5222
4865
4533
4225
3932
3662
3411
3177
2960
2756
2568
2393
2 For practical applications a more precise description of the real
R/T curve may be required. Either more complicated approaches (e.g
the Steinhart-Hart equation) are used or the resistance/
temperature relation as given in tabulated form. The below table
has been experimentally determined with utmost accuracy for
temperature increments of 1 degree.
Temperature
°C
Resistance
(ohm)
Max.
Deviation
Temperature
°C
-2
-1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
33100
31557
30029
28627
27299
26042
24852
23773
22708
21698
20739
19829
18959
18128
17338
16588
15876
15207
14569
13962
13384
12834
12280
11777
11297
10840
10404
10000
2230
2078
1932
1799
1675
1560
1452
1355
1261
1174
1093
1017
946
879
817
759
705
654
607
563
522
484
447
413
382
353
325
300
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
Resistance
(ohm)
9600
9218
8853
8506
8178
7866
7568
7283
7011
6734
6484
6244
6015
5796
5575
5373
5180
4995
4817
4636
4473
4316
4166
4021
3874
3737
3606
3481
Max.
Deviation
Temperature
°C
Resistance
(ohm)
Max.
Deviation
300
300
299
297
296
294
292
290
287
284
281
278
275
271
267
264
260
257
253
248
245
241
237
233
229
225
221
217
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
3360
3237
3126
3019
2917
2819
2720
2629
2542
2458
2378
2304
2229
2158
2089
2022
1960
1898
1839
1782
1727
1673
1622
1573
1526
1480
1432
213
208
204
200
197
193
189
185
182
178
175
171
168
165
161
158
155
152
149
146
143
140
138
135
132
130
127
Humirel Sensor Device Data / HPC053 RevD June 2005
TECHNICAL
4 DATA
QUALIFICATION PROCESS
Resistance to physical and chemical stresses
● HTF3226LF has passed through qualification processes of HUMIREL including vibration, shock,
storage, high temperature and humidity, ESD.
●
Additional tests under harsh chemical conditions demonstrate good operation in presence of salt
atmosphere, SO2 (0.5%, H2S (0.5%), 03, NOx, NO, CO, CO2, Softener, Soap, Toluene, acids (H2SO4, HNO3,
HCI), HMDS, Insecticide, Cigarette smoke, this is not an exhaustive list.
●
HTF3226LF is not light sensitive.
PACKAGE OUTLINE
HTF3226LF
Dim
A
B
Min 9.7 8.5
Max 10.8 9.5
Dim
H
J
Min
Max
4.8
6.2
7.3
7.7
C
D
E
F
G
28.0 14.5 1.5 3.5 1.45
29.0 15.5 1.7 3.9 1.55
K
L
M
N
Φ
3.0
3.4
Dimensions in millimeters
Connector type : JST model S4B-ZR
to be mated with ZHR or 04ZR type female connectors
ORDERING INFORMATION (Multiple Package Quantity of 50 pieces) :HPP808G031
HTF3226LF : Humidity Frequency output + NTC (Temperature direct output)
SAMPLE KIT OF HTF 3226LF
IS AVAILABLE THROUGH
HUMIREL WEB SITE
www.humirel.com
email : [email protected]
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsability is assumed for inaccuracies. Furthermore, this information does not convey
to the purchaser of such devices any license under the patent rights to the manufacturer. Humirel reserves the right to make changes without further notice to any product herein. Humirel
makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Humirel assume any liability arising out of the application or use
of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. « Typical » parameters can and do vary in different
applications. All operating parameters, including « Typical » must be validated for each customer applications by customer’s technical experts. Humirel does not convey any license under its
patent rights nor the rights of others. Humirel products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other application intended to support or sustain life, or for any application in which the failure of the Humirel product could create a situation where personal injury or death may occur. Should buyer
purchase or use Humirel products for any such unintended or unauthorized application, Buyer shall indemnify and hold Humirel and its officers, employees, subsidaries, affiliates and distributors harmless against all claims, costs, damages and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of presonal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Humirel was negligent regarding the design or manufacture of the part.Humirel is a registred trade mark of Humirel.
Humirel Sensor Device Data / HPC053 RevD June 2005