HUMIREL HPP804B130

TECHNICAL
1 DATA
TEMPERATURE AND RELATIVE HUMIDITY SENSOR HTS2030SMD
Meets RoHS regulations
Based on a unique capacitive cell for humidity measurement and a Negative
Temperature Coefficient (NTC) thermistor for temperature measurement, this dual purpose
relative humidity / temperature miniaturized sensor is designed for high volume, cost
sensitive applications with tight space constraints. It is useful in all applications where
dew point, absolute humidity measurements or humidity compensation are required.
MAIN FEATURES
● Miniature Surface mount SMD package.
● Lead free components.
● Full interchangeability with no calibration required in standard conditions.
● Instantaneous desaturation after long periods in saturation phase.
● Compatible with automatized assembly processes, including Pb free
wave soldering and reflow processes (1)
● High reliability and long term stability.
● Patented solid polymer structure.
● Suitable for linear voltage or frequency output circuitry.
● Fast response time and very low temperature coefficient.
● Part may be washed with distilled water.
● Individual marking for compliance to stringent traceability requirements.
(1)
soldering temperature profiles available on request / contact us at [email protected]
MAXIMUM RATINGS
Ratings
Operating Range
100
Symbol
Value
Unit
Ta
-60 to 140
°C
Storage Temperature
Tstg
-60 to 140
°C
Supply Voltage (Peak)
Vs
10
Vac
Humidity Operating Range
RH
0 to 100
% RH
90
80
70
Relative Humidity in % RH
Operating Temperature
60
50
40
30
20
10
0
-60
-40
-20
0
20
40
60
80
100
120
140
Temperature in °C
CHARACTERISTICS
Humidity sensor (Ta = 25°C, measurement frequency @ 10kHz unless otherwise noted)
Characteristics
Symbol
Min.
Humidity measuring range
RH
1
Supply voltage
Vs
Nominal capacitance @ 55% RH*
C
Temperature coefficient
Averaged Sensitivity from 33% to 75% RH
177
Typ.
180
Tcc
∆C /% RH
Leakage current (Vcc = 5 Volts)
I
Recovery time after 150 hours of condensation
tr
Unit.
99
%RH
10
V
183
pF
0.01
pF/°C
0.31
pF/% RH
1
nA
10
Humidity Hysteresis
s
+/-1
Long term stability
τ
+/-0.5
Time constant (33 to 80 % RH, still air @ 63%)
ta
3
Deviation to typical response curve (10% to 90%) RH)
Max.
+/-2
%RH
%RH/yr
5
s
%RH
*tighter specification available on request
HUMIREL HPC055 Rev0 June 2004
HTS2030SMD
160
TECHNICAL
2 DATA
TYPICAL RESPONSE IN HUMIDITY
•
Polynomial response of HTS2030SMD:
C (pF)=C@55 %*( 3.903 10-8 *RH3-8.294 10-6 *RH2+2.188 10-3 *RH+0.898)
Typical response look-up table (Polynomial Reference curve) “10kHz/1V”
0
5
10
15
20
25
30
35
40
45
50
Cp (pF)
161.6
163.6
165.4
167.2
169.0
170.7
172.3
173.9
175.5
177.0
178.5
RH (%)
55
60
65
70
75
80
85
90
95
100
Cp (pF)
180
181.4
182.9
184.3
185.7
187.2
188.6
190.1
191.6
193.1
10
20
30
40
60
70
80
90
Capacitance (pF)
RH (%)
195
190
185
180
175
170
165
160
0
•
50
100
%RH
Reversed Polynomial response of HTS2030SMD:
RH (%) = -3.4656 10+3 *X3+1.0732 10+4 *X2-1.0457 10+4 *X+3.2459 10+3
With X=C(read) / C@55%RH
CHARACTERISTICS
Temperature sensor
Symbol
Min.
Typ
10
Max.
Beta value : B25/100
B
3600
3730
3800
Temperature measuring range
Ta
-60
Nominal Resistance Toleranceat 25°C
Rn
2
B value tolerance
B
3
%
Response Time
τ
10
s
Characteristics
Nominal resistance @ 25°C
Unit.
kΩ
140
°C
3
%
TYPICAL TEMPERATURE OUTPUT
HUMIREL HPC055 Rev0 June 2004
HTS2030SMD
TECHNICAL
3 DATA
Temperature look-up table
Temp °C
Resistance
(Ohm)
Max.
deviation
Temp °C
Resistance (Ohm)
Max.
deviation
Temp °C
Resistance (Ohm)
Max.
deviation
Temp °C
Resistance (Ohm)
Max.
deviation
-40
262960
35403
-5
38279
2756
30
8178
296
65
2304
171
-39
247217
32777
-4
36455
2568
31
7866
294
66
2229
168
-38
232539
30358
-3
34731
2393
32
7568
292
67
2158
165
-37
218845
28130
-2
33100
2230
33
7283
290
68
2089
161
-36
206064
26075
-1
31557
2078
34
7011
287
69
2022
158
-35
194110
24178
0
30029
1932
35
6734
284
70
1960
155
-34
182852
22416
1
28627
1799
36
6484
281
71
1898
152
-33
172332
20791
2
27299
1675
37
6244
278
72
1839
149
-32
162498
19290
3
26042
1560
38
6015
275
73
1782
146
-31
153299
17905
4
24852
1452
39
5796
271
74
1727
143
-30
144790
16636
5
23773
1355
40
5575
267
75
1673
140
-29
136664
15444
6
22708
1261
41
5373
264
76
1622
138
-28
129054
14343
7
21698
1174
42
5180
260
77
1573
135
-27
121925
13325
8
20739
1093
43
4995
257
78
1526
132
-26
115243
12383
9
19829
1017
44
4817
253
79
1480
130
-25
109030
11516
10
18959
946
45
4636
248
80
1432
127
-24
103115
10705
11
18128
879
46
4473
245
81
1390
124
-23
97565
9953
12
17338
817
47
4316
241
82
1349
122
-22
92354
9257
13
16588
759
48
4166
237
83
1310
119
-21
87460
8612
14
15876
705
49
4021
233
84
1272
117
-20
82923
8020
15
15207
654
50
3874
229
85
1235
115
-19
78581
7463
16
14569
607
51
3737
225
86
1199
112
-18
74497
6947
17
13962
563
52
3606
221
87
1163
110
-17
70655
6468
18
13384
522
53
3481
217
88
1130
108
-16
67039
6023
19
12834
484
54
3360
213
89
1097
106
-15
63591
5606
20
12280
447
55
3237
208
90
1067
104
-14
60381
5222
21
11777
413
56
3126
204
91
1038
102
-13
57356
4865
22
11297
382
57
3019
200
92
1009
100
-12
54503
4533
23
10840
353
58
2917
197
93
982
98
-11
51813
4225
24
10404
325
59
2819
193
94
955
96
-10
49204
3932
25
10000
300
60
2720
189
95
927
94
-9
46767
3662
26
9600
300
61
2629
185
96
901
92
-8
44467
3411
27
9218
300
62
2542
182
97
877
90
-7
42296
3177
28
8853
299
63
2458
178
98
853
89
-6
40247
2960
29
8506
297
64
2378
175
99
830
87
SUGGESTED FREQUENCY OUTPUT CIRCUITS
Note: R22=499kΩ /
R4=49.9kΩ / R1=1 kΩ /
RV1=50 kΩ potentiometer /
C1=10nF / C2=2.2nF / C3=100nF
Typical response look-up table (Humidity output)
RH (%)
0
5
Fout (Hz)
RH (%)
Fout (Hz)
10
15
20
25
30
35
40
45
50
7155
7080
7010
6945
6880
6820
6760
6705
6650
100
55
60
65
70
75
80
85
90
95
6600
6550
6500
6450
6400
6355
6305
6260
6210
HUMIREL HPC055 Rev0 June 2004
HTS2030SMD
TECHNICAL
4 DATA
QUALIFICATION PROCESS
HTS2030SMD sensors have been qualified through a complete qualification process taking in account
many of the requirements of the JEDEC standard including:
•
•
•
•
•
•
•
•
Solder heat and solderability including
lead free process.
Pb free wave soldering and reflow
soldering process(260°C) + DI water
clean at 45°C
Mechanical shock JESD-22-B104-A
Vibration - Variable frequency(20 to
2000Hz) JESD-22-B103-A
Marking permanency
ESD - Electrostatic Discharge –Air Gun
+-15kV(IEC 1000)
Salt Atmosphere JESD22-A107-A
Temperature Cycling - 40°C / +125°C
•
•
•
•
•
High Temperature / Humidity Operating
Life - 93%RH / 60°C for 1000 hours
Low Humidity storage life - RH <
10%/23°C - 1000 hours
Resistance to immersion in water at
ambient temperature and 80°C
High temperature storage 140°C for 168
hours.
Resistance to many chemicals linked to
home appliances/automotive or
consumer applications.
ENVIRONMENTAL AND RECYCLING
HTS2030SMD sensors are lead free components and are compatible with Pb Free soldering
processes.HTS2030SMD sensors are free from Cr (6+), Cd and Hg.
SOLDERING INSTRUCTIONS
See Application Note. To get it, please contact: [email protected]
PACKAGE OUTLINE HTS2030SMD GULL WING (JLEAD option also available)
Dimensions in millimeters
FOOTPRINT
ORDERING INFORMATION of HTS2030SMD:
• HPP804B130: TUBE M.P.Q. OF 78 PIECES.
• HPP804B131: TAPE AND REEL M.P.Q. OF 1500 PIECES.
TEMPERATURE AND RELATIVE HUMIDITY SENSORS.
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsability is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent
rights to the manufacturer. Humirel reserves the right to make changes without further notice to any product herein. Humirel makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Humirel
assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. « Typical » parameters can and do vary in different applications.
All operating parameters, including « Typical » must be validated for each customer applications by customer’s technical experts. Humirel does not convey any license under its patent rights nor the rights of others. Humirel products are not designed,
intended, or authorized for use as components in systems intended for surgical implant into the body, or other application intended to support or sustain life, or for any application in which the failure of the Humirel product could create a situation where
personal injury or death may occur. Should buyer purchase or use Humirel products for any such unintended or unauthorized application, Buyer shall indemnify and hold Humirel and its officers, employees, subsidaries, affiliates and distributors
harmless against all claims, costs, damages and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of presonal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Humirel
was negligent regarding the design or manufacture of the part.Humirel is a registred trade mark of Humirel.
HUMIREL HPC055 Rev0 June 2004
HTS2030SMD