HYNIX HY5V26CF-8

HY5V26C(L/S)F
4 Banks x 2M x 16bits Synchronous DRAM
DESCRIPTION
Preliminary
The Hynix HY5V26C(L/S)F is a 134,217,728bit CMOS Synchronous DRAM, ideally suited for the main memory applications which
require large memory density and high bandwidth. HY5V26C(L/S)F is organized as 4banks of 2,097,152x16
HY5V26C(L/S)F is offering fully synchronous operation referenced to a positive edge of the clock. All inputs and outputs are synchronized with the rising edge of the clock input. The data paths are internally pipelined to achieve very high bandwidth. All input and output
voltage levels are compatible with LVTTL.
Programmable options include the length of pipeline (Read latency of 2 or 3), the number of consecutive read or write cycles initiated
by a single control command (Burst length of 1,2,4,8, or full page), and the burst count sequence(sequential or interleave). A burst of
read or write cycles in progress can be terminated by a burst terminate command or can be interrupted and replaced by a new burst
read or write command on any cycle. (This pipelined design is not restricted by a `2N` rule.)
FEATURES
•
Single 3.3±0.3V power supply
•
Auto refresh and self refresh
•
All device balls are compatible with LVTTL interface
•
4096 refresh cycles / 64ms
•
54Ball FBGA (10.5mm x 8.3mm)
•
Programmable Burst Length and Burst Type
•
All inputs and outputs referenced to positive edge of
system clock
•
Data mask function by UDQM or LDQM
•
Internal four banks operation
- 1, 2, 4, 8 or Full page for Sequential Burst
- 1, 2, 4 or 8 for Interleave Burst
•
Programmable CAS Latency ; 2, 3 Clocks
ORDERING INFORMATION
Part No.
Clock Frequency
HY5V26CF-6
166MHz
HY5V26CF-K
133MHz
HY5V26CF-H
133MHz
HY5V26CF-8
125MHz
HY5V26CF-P
100MHz
HY5V26CF-S
100MHz
HY5V26C(L/S)F-6
166MHz
HY5V26C(L/S)F-K
133MHz
HY5V26C(L/S)F-H
133MHz
HY5V26C(L/S)F-8
125MHz
HY5V26C(L/S)F-P
100MHz
HY5V26C(L/S)F-S
100MHz
Power
Organization
Interface
Package
4Banks x 2Mbits
x16
LVTTL
54ball FBGA
Normal
Low power
This document is a general product description and is subject to change without notice. Hynix does not assume any responsibility for use of circuits described. No patent licenses are implied.
Rev. 0.9/Jul. 02
1
HY5V26C(L/S)F
BALL CONFIGURATION
9
8
7
3
2
1
A
B
C
54 Ball
FBGA
0.8 mm
Ball Pitch
D
E
F
G
H
J
< Bottom View >
7
1
2
3
VSS
DQ15
VSSQ
A
DQ14
DQ13
VDDQ
DQ12
DQ11
DQ10
8
9
VDDQ
DQ0
VDD
B
VSSQ
DQ2
DQ1
VSSQ
C
VDDQ
DQ4
DQ3
DQ9
VDDQ
D
VSSQ
DQ6
DQ5
DQ8
NC
VSS
E
VDD
LDQM
DQ7
UDQM
CLK
CKE
F
/CAS
/RAS
/WE
NC
A11
A9
G
BA0
BA1
/CS
A8
A7
A6
H
A0
A1
A10
VSS
A5
A4
J
A3
A2
VDD
< Top View >
Rev. 0.9/Jul. 02
2
HY5V26C(L/S)F
BALL DESCRIPTION
BALL OUT
SYMBOL
TYPE
DESCRIPTION
F2
CLK
INPUT
Clock : The system clock input. All other inputs are registered to the
SDRAM on the rising edge of CLK
F3
CKE
INPUT
Clock Enable : Controls internal clock signal and when deactivated,
the SDRAM will be one of the states among power down, suspend or
self refresh
G9
CS
INPUT
Chip Select : Enables or disables all inputs except CLK, CKE, UDQM
and LDQM
G7,G8
BA0, BA1
INPUT
Bank Address : Selects bank to be activated during RAS activity
Selects bank to be read/written during CAS activity
H7, H8, J8, J7,
J3, J2, H3, H2,
H1, G3, H9, G2
A0 ~ A11
INPUT
Row Address : RA0 ~ RA11, Column Address : CA0 ~ CA8
Auto-precharge flag : A10
F8, F7, F9
RAS, CAS,
WE
INPUT
Command Inputs : RAS, CAS and WE define the operation
Refer function truth table for details
F1, E8
UDQM,
LDQM
INPUT
Data Mask:Controls output buffers in read mode and masks input
data in write mode
A8, B9, B8, C9,
C8, D9, D8, E9,
E1, D2, D1, C2,
C1, B2, B1, A2
DQ0 ~ DQ15 I/O
Data Input/Output:Multiplexed data input/output ball
A9, E7, J9, A1,
E3, J1
VDD/VSS
Power supply for internal circuits
A7, B3, C7, D3,
A3, B7, C3, D7
VDDQ/VSSQ SUPPLY
Power supply for output buffers
E2, G1
NC
No connection
SUPPLY
-
HY5V26C(L/S)F
FUNCTIONAL BLOCK DIAGRAM
2Mbit x 4banks x 16 I/O Synchronous DRAM
Self refresh logic
& timer
Internal Row
counter
2Mx16 Bank 3
CLK
Row active
Row
Pre
Decoders
2Mx16 Bank 2
CS
Column
Pre
Decoders
UDQM
Y decoders
LDQM
Bank Select
A0
A1
Rev. 0.9/Jul. 02
DQ1
DQ14
DQ15
Column Add
Counter
Address
Registers
Address buffers
A11
BA0
BA1
DQ0
I/O Buffer & Logic
Column
Active
Memory
Cell
Array
Sense AMP & I/O Gate
WE
refresh
2Mx16 Bank 0
X decoders
CAS
State Machine
RAS
2Mx16 Bank 1
X decoders
X decoders
X decoders
CKE
Burst
Counter
Mode Registers
CAS Latency
Data Out Control
Pipe Line Control
4
HY5V26C(L/S)F
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Rating
Unit
Ambient Temperature
TA
0 ~ 70
°C
Storage Temperature
TSTG
-55 ~ 125
°C
Voltage on Any ball relative to VSS
VIN, VOUT
-1.0 ~ 4.6
V
Voltage on VDD relative to VSS
VDD, VDDQ
-1.0 ~ 4.6
V
Short Circuit Output Current
IOS
50
mA
Power Dissipation
PD
1
W
Soldering Temperature ⋅ Time
TSOLDER
260 ⋅ 10
°C ⋅ Sec
Note : Operation at above absolute maximum rating can adversely affect device reliability.
DC OPERATING CONDITION (TA=0 to 70°C)
Parameter
Symbol
Min
Typ
Max
Unit
Note
Power Supply Voltage
VDD, VDDQ
3.0
3.3
3.6
V
1
Input High voltage
VIH
2.0
3.0
VDDQ + 0.3
V
1,2
Input Low voltage
VIL
-0.3
0
0.8
V
1,3
Note
Note :
1.All voltages are referenced to VSS = 0V
2.VIH(max) is acceptable 5.6V AC pulse width with <=3ns of duration.
3.VIL(min) is acceptable -2.0V AC pulse width with <=3ns of duration.
AC OPERATING TEST CONDITION (TA=0 to 70°C, VDD=3.3±0.3V, VSS=0V)
Parameter
Symbol
Value
Unit
VIH / VIL
2.4/0.4
V
Vtrip
1.4
V
Input Rise / Fall Time
tR / tF
1
ns
Output Timing Measurement Reference Level Voltage
Voutref
1.4
V
CL
50
pF
AC Input High / Low Level Voltage
Input Timing Measurement Reference Level Voltage
Output Load Capacitance for Access Time Measurement
1
Note :
1.Output load to measure access times is equivalent to two TTL gates and one capacitor (50pF). For details, refer to AC/DC output
load circuit
Rev. 0.9/Jul. 02
5
HY5V26C(L/S)F
CAPACITANCE (TA=25°C, f=1MHz)
-6/K/H
Parameter
ball
Input capacitance
Data input / output capacitance
-8/P/S
Symbol
Unit
Min
Max
Min
Max
CLK
CI1
2.5
3.5
2.5
4.0
pF
A0 ~ A11, BA0, BA1, CKE, CS, RAS, CAS,
WE, UDQM, LDQM
CI2
2.5
3.8
2.5
5.0
pF
DQ0 ~ DQ15
CI/O
4.0
6.5
4.0
6.5
pF
OUTPUT LOAD CIRCUIT
Vtt=1.4V
RT=250 Ω
Output
Output
50pF
50pF
DC Output Load Circuit
AC Output Load Circuit
DC CHARACTERISTICS I (TA=0 to 70°C, VDD=3.3±0.3V)
Parameter
Symbol
Min.
Max
Unit
Note
Input Leakage Current
ILI
-1
1
uA
1
Output Leakage Current
ILO
-1
1
uA
2
Output High Voltage
VOH
2.4
-
V
IOH = -2mA
Output Low Voltage
VOL
-
0.4
V
IOL = +2mA
Note :
1.VIN = 0 to 3.6V, All other balls are not tested under VIN =0V
2.DOUT is disabled, VOUT=0 to 3.6
Rev. 0.9/Jul. 02
6
HY5V26C(L/S)F
DC CHARACTERISTICS II (TA=0 to 70°C, VDD=3.3±0.3V, VSS=0V)
Speed
Parameter
Symbol
Test Condition
-6
-K
-H
-8
-P
-S
130
120
120
120
110
110
IDD1
Burst length=1, One bank active
tRC ≥ tRC(min), IOL=0mA
IDD2P
CKE ≤ VIL(max), tCK = 15ns
2
IDD2PS
CKE ≤ VIL(max), tCK = ∞
1
IDD2N
CKE ≥ VIH(min), CS ≥ VIH(min), tCK = 15ns
Input signals are changed one time during
30ns. All other balls ≥ VDD-0.2V or ≤ 0.2V
15
IDD2NS
CKE ≥ VIH(min), tCK = ∞
Input signals are stable.
15
IDD3P
CKE ≤ VIL(max), tCK = 15ns
5
IDD3PS
CKE ≤ VIL(max), tCK = ∞
5
IDD3N
CKE ≥ VIH(min), CS ≥ VIH(min), tCK = 15ns
Input signals are changed one time during
30ns. All other balls ≥ VDD-0.2V or ≤ 0.2V
30
IDD3NS
CKE ≥ VIH(min), tCK = ∞
Input signals are stable.
20
Burst Mode Operating
Current
IDD4
tCK ≥ tCK(min), IOL=0mA
All banks active
Auto Refresh Current
IDD5
Operating Current
Precharge Standby Current
in Power Down Mode
Precharge Standby Current
in Non Power Down Mode
Active Standby Current
in Power Down Mode
Active Standby Current
in Non Power Down Mode
Self Refresh Current
IDD6
Note
mA
1
mA
mA
mA
mA
CL=3
150
130
130
130
110
110
CL=2
160
140
140
140
120
120
240
220
220
200
200
200
tRRC ≥ tRRC(min), All banks active
CKE ≤ 0.2V
Unit
mA
1
mA
2
2
mA
3
800
uA
4
500
uA
5
Note :
1.IDD1 and IDD4 depend on output loading and cycle rates. Specified values are measured with the output open
2.Min. of tRRC (Refresh RAS cycle time) is shown at AC CHARACTERISTICS II
3.HY5V26CF-6/K/H/8/P/S
4.HY5V26CLF-6/K/H/8/P/S
5.HY5V26CSF-6/K/H/8/P/S
Rev. 0.9/Jul. 02
7
HY5V26C(L/S)F
AC CHARACTERISTICS I (AC operating conditions unless otherwise noted)
-6
Parameter
CAS Latency = 3
tCK3
Max
6
Min
Max
7.5
1000
-8
-P
-S
Min
Max
7.5
1000
Max
8
1000
10
Min
Max
10
1000
10
Min
10
1000
10
Note
Max
ns
1000
10
Clock High Pulse Width
tCHW
2.5
-
2.5
-
2.5
-
3
-
3
-
3
-
ns
1
Clock Low Pulse Width
tCLW
2.5
-
2.5
-
2.5
-
3
-
3
-
3
-
ns
1
CAS Latency = 3
tAC3
-
5.4
-
5.4
-
5.4
-
6
-
6
-
6
ns
CAS Latency = 2
tAC2
-
6
-
5.4
-
6
-
6
-
6
-
6
ns
Data-Out Hold Time
tOH
2.7
-
2.7
-
2.7
-
3
-
3
-
3
-
ns
Data-Input Setup Time
tDS
1.5
-
1.5
-
1.5
-
2
-
2
-
2
-
ns
1
Data-Input Hold Time
tDH
0.8
-
0.8
-
0.8
-
1
-
1
-
1
-
ns
1
Address Setup Time
tAS
1.5
-
1.5
-
1.5
-
2
-
2
-
2
-
ns
1
Address Hold Time
tAH
0.8
-
0.8
-
0.8
-
1
-
1
-
1
-
ns
1
CKE Setup Time
tCKS
1.5
-
1.5
-
1.5
-
2
-
2
-
2
-
ns
1
CKE Hold Time
tCKH
0.8
-
0.8
-
0.8
-
1
-
1
-
1
-
ns
1
Command Setup Time
tCS
1.5
-
1.5
-
1.5
-
2
-
2
-
2
-
ns
1
Command Hold Time
tCH
0.8
-
0.8
-
0.8
-
1
-
1
-
1
-
ns
1
CLK to Data Output in Low-Z Time
tOLZ
1
-
1
-
1
-
1
-
1
-
1
-
ns
CLK to Data Output
in High-Z Time
7.5
Min
tCK2
Access Time From
Clock
CAS Latency = 2
-H
Unit
Min
System Clock Cycle
Time
-K
Symbol
12
ns
2
CAS Latency = 3
tOHZ3
2.7
5.4
2.7
5.4
2.7
5.4
3
6
3
6
3
6
ns
CAS Latency = 2
tOHZ2
2.7
5.4
2.7
5.4
3
6
3
6
3
6
3
6
ns
Note :
1.Assume tR / tF (input rise and fall time ) is 1ns
If tR & tF > 1ns, then [(tR+tF)/2-1]ns should be added to the parameter
2.Access times to be measured with input signals of 1v/ns edge rate, from 0.8v to 2.0v
If tR > 1ns, then (tR/2-0.5)ns should be added to the parameter
Rev. 0.9/Jul. 02
8
HY5V26C(L/S)F
AC CHARACTERISTICS II
-6
Parameter
-K
-H
-8
-P
-S
Symbol
Unit
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Operation
tRC
60
-
60
-
65
-
68
-
70
-
70
-
ns
Auto Refresh
tRRC
60
-
65
-
65
-
68
-
70
-
70
-
ns
RAS to CAS Delay
tRCD
18
-
15
-
20
-
20
-
20
-
20
-
ns
RAS Active Time
tRAS
42
100K
45
100K
45
100K
48
100K
50
100K
50
100K
ns
RAS Precharge Time
tRP
18
-
15
-
20
-
20
-
20
-
20
-
ns
RAS to RAS Bank Active Delay
tRRD
12
-
15
-
15
-
16
-
20
-
20
-
ns
CAS to CAS Delay
tCCD
1
-
1
-
1
-
1
-
1
-
1
-
CLK
Write Command to Data-In Delay
tWTL
0
-
0
-
0
-
0
-
0
-
0
-
CLK
Data-In to Precharge Command
tDPL
2
-
2
-
2
-
1
-
1
-
1
-
CLK
Data-In to Active Command
tDAL
5
-
4
-
5
-
4
-
3
-
3
-
CLK
DQM to Data-Out Hi-Z
tDQZ
2
-
2
-
2
-
2
-
2
-
2
-
CLK
DQM to Data-In Mask
tDQM
0
-
0
-
0
-
0
-
0
-
0
-
CLK
MRS to New Command
tMRD
2
-
2
-
2
-
2
-
2
-
2
-
CLK
CAS Latency = 3
tPROZ3
3
-
3
-
3
-
3
-
3
-
3
-
CLK
CAS Latency = 2
tPROZ2
2
-
2
-
2
-
2
-
2
-
2
-
CLK
Power Down Exit Time
tPDE
1
-
1
-
1
-
1
-
1
-
1
-
CLK
Self Refresh Exit Time
tSRE
1
-
1
-
1
-
1
-
1
-
1
-
CLK
Refresh Time
tREF
-
64
-
64
-
64
-
64
-
64
-
64
ms
Note
RAS Cycle Time
Precharge to Data
Output Hi-Z
1
Note :
1. A new command can be given tRRC after self refresh exit
Rev. 0.9/Jul. 02
9
HY5V26C(L/S)F
IBIS SPECIFICATION
IOH Characteristics (Pull-up)
Voltage
100MHz
(Min)
100MHz
(Max)
66MHz
(Min)
(V)
I(mA)
I(mA)
I(mA)
-2.4
3.3
-27.3
0
0.5
1
1.5
2
2.5
3
3.5
0
-100
3.0
0
-74.1
-0.7
2.6
-21.1
-129.2
-7.5
2.4
-34.1
-153.3
-13.3
2.0
-58.7
-197
-27.5
1.8
-67.3
-226.2
-35.5
1.65
-73
-248
-41.1
1.5
-77.9
-269.7
-47.9
1.4
-80.8
-284.3
-52.4
1.0
-88.6
-344.5
-72.5
0
-93
-502.4
-93
-200
I (mA)
3.45
66MHz and 100MHz Pull-up
-300
-400
-500
-600
Voltage (V)
IOH Min (100MHz)
IOH Min (66MHz)
IOH Max (66 /100MHz)
IOL Characteristics (Pull-down)
66MHz and 100MHz Pull-down
Voltage
100MHz
(Min)
100MHz
(Max)
66MHz
(Min)
(V)
I(mA)
I(mA)
I(mA)
0
0
0
0
0.4
27.5
70.2
17.7
0.65
41.8
107.5
26.9
0.85
51.6
133.8
33.3
1.0
58.0
151.2
37.6
1.4
70.7
187.7
46.6
1.5
72.9
194.4
48.0
1.65
75.4
202.5
49.5
1.8
77.0
208.6
50.7
Voltage (V)
1.95
77.6
212.0
51.5
IOL Min (100MHz)
3.0
80.3
219.6
54.2
IOL Min (66MHz)
3.45
81.4
222.6
54.9
IOL Max (100MHz)
Rev. 0.9/Jul. 02
250
I (mA)
200
150
100
50
0
0
0.5
1
1.5
2
2.5
3
3.5
10
HY5V26C(L/S)F
VDD Clamp @ CLK, CKE, CS, DQM & DQ
I(mA)
0.0
0.0
0.2
0.0
0.4
0.0
0.6
0.0
0.7
0.0
0.8
0.0
0.9
0.0
1.0
0.23
1.2
1.34
1.4
3.02
1.6
5.06
1.8
7.35
2.0
9.83
2.2
12.48
2.4
15.30
2.6
18.31
20
15
mA
VDD (V)
Minimum VDD clamp current
(Referenced to VDD)
10
5
0
0
-2.6
-57.23
-2.4
-45.77
-2.2
-38.26
-2.0
-31.22
-1.8
-24.58
-1.6
-18.37
-1.4
-12.56
-1.2
-7.57
-1.0
-3.37
-0.9
-1.75
-0.8
-0.58
-0.7
-0.05
-0.6
0.0
-0.4
0.0
-0.2
0.0
0.0
0.0
Rev. 0.9/Jul. 02
3
I (mA)
Minimum VSS clamp current
-3
-2.5
-2
-1.5
-1
-0.5
0
0
-10
-20
mA
I (mA)
2
Voltage
VSS Clamp @ CLK, CKE, CS, DQM & DQ
VSS (V)
1
-30
-40
-50
-60
Voltage
I (mA)
11
HY5V26C(L/S)F
DEVICE OPERATING OPTION TABLE
HY5V26C(L/S)F-6
CAS Latency
tRCD
tRAS
tRC
tRP
tAC
tOH
166MHz(6ns)
3CLKs
3CLKs
7CLKs
10CLKs
3CLKs
5.4ns
2.7ns
143MHz(7ns)
3CLKs
3CLKs
6CLKs
9CLKs
3CLKs
5.4ns
2.7ns
133MHz(7.5ns)
2CLKs
3CLKs
6CLKs
9CLKs
3CLKs
5.4ns
2.7ns
HY5V26C(L/S)F-K
CAS Latency
tRCD
tRAS
tRC
tRP
tAC
tOH
133MHz(7.5ns)
2CLKs
2CLKs
6CLKs
8CLKs
2CLKs
5.4ns
2.7ns
125MHz(8ns)
3CLKs
3CLKs
6CLKs
9CLKs
3CLKs
6ns
3ns
100MHz(10ns)
2CLKs
2CLKs
5CLKs
7CLKs
2CLKs
6ns
3ns
HY5V26C(L/S)F-H
CAS Latency
tRCD
tRAS
tRC
tRP
tAC
tOH
133MHz(7.5ns)
3CLKs
3CLKs
6CLKs
9CLKs
3CLKs
5.4ns
2.7ns
125MHz(8ns)
3CLKs
3CLKs
6CLKs
9CLKs
3CLKs
6ns
3ns
100MHz(10ns)
2CLKs
2CLKs
5CLKs
7CLKs
2CLKs
6ns
3ns
CAS Latency
tRCD
tRAS
tRC
tRP
tAC
tOH
HY5V26C(L/S)F-8
125MHz(8ns)
3CLKs
3CLKs
6CLKs
9CLKs
3CLKs
6ns
3ns
100MHz(10ns)
2CLKs
2CLKs
5CLKs
7CLKs
2CLKs
6ns
3ns
83MHz(12ns)
2CLKs
2CLKs
4CLKs
6CLKs
2CLKs
6ns
3ns
CAS Latency
tRCD
tRAS
tRC
tRP
tAC
tOH
100MHz(10ns)
2CLKs
2CLKs
5CLKs
7CLKs
2CLKs
6ns
3ns
83MHz(12ns)
2CLKs
2CLKs
5CLKs
7CLKs
2CLKs
6ns
3ns
66MHz(15ns)
2CLKs
2CLKs
4CLKs
6CLKs
2CLKs
6ns
3ns
HY5V26C(L/S)F-P
HY5V26C(L/S)F-S
CAS Latency
tRCD
tRAS
tRC
tRP
tAC
tOH
100MHz(10ns)
3CLKs
2CLKs
5CLKs
7CLKs
2CLKs
6ns
3ns
83MHz(12ns)
2CLKs
2CLKs
5CLKs
7CLKs
2CLKs
6ns
3ns
66MHz(15ns)
2CLKs
2CLKs
4CLKs
6CLKs
2CLKs
6ns
3ns
Rev. 0.9/Jul. 02
12
HY5V26C(L/S)F
COMMAND TRUTH TABLE
Command
A10/
AP
CKEn-1
CKEn
CS
RAS
CAS
WE
DQM
Mode Register Set
H
X
L
L
L
L
X
OP code
H
X
X
X
No Operation
H
X
X
X
L
H
H
H
Bank Active
H
X
L
L
H
H
X
H
X
L
H
L
H
X
ADDR
RA
Read
Note
V
L
CA
Read with Autoprecharge
V
H
Write
L
H
X
L
H
L
L
X
CA
Write with Autoprecharge
H
X
L
L
H
L
X
Burst Stop
H
X
DQM
H
Auto Refresh
H
H
L
L
L
Burst-Read-Single-WRITE
H
X
L
L
Entry
H
L
L
H
H
H
Exit
L
H
L
L
V
X
V
X
H
X
X
L
H
X
A9 ball High
(Other balls OP code)
L
L
H
X
X
X
X
X
X
L
H
H
H
H
X
X
X
L
H
H
H
H
X
X
X
L
H
H
H
H
X
X
X
L
V
V
V
L
Precharge power
down
X
X
X
Self Refresh1
H
L
H
X
Precharge selected Bank
Entry
V
H
Precharge All Banks
X
X
Exit
Clock
Suspend
BA
Entry
Exit
L
H
L
H
X
L
H
X
X
X
X
Note :
1. Exiting Self Refresh occurs by asynchronously bringing CKE from low to high
2. X = Don′t care, H = Logic High, L = Logic Low. BA =Bank Address, RA = Row Address, CA = Column Address,
Opcode = Operand Code, NOP = No Operation
Rev. 0.9/Jul. 02
13
HY5V26C(L/S)F
PACKAGE INFORMATION
54 Ball 0.8mm pitch 8.3mm x 10.5mm FBGA
Rev. 0.9/Jul. 02
14