ETC AAM3203Q10

aAM3202 / aAM3203
ULTRA LOW POWER, DUAL-SPDT
CMOS ANALOG SWITCHES
The aAM3202 and aAM3203 are precision CMOS
analog dual-SPDT switches or 2:1 multiplexers offering
low on-resistance of less than 4Ω, with better than 0.4Ω
matching between channels and on-resistance flatness
of less than 1.2Ω over the specified analog input voltage
range. The aAM3202 and aAM3203 have very fast turnon switching speed of less than 16nS over the full
operating temperature range of -40°C to 85°C. The
aAM3202 and aAM3203 also consume a minimal
amount of power, making them ideal for portable
equipment.
Pin Configuration
The aAM3202 and aAM3203 connect 1-of-2 inputs to a
common output by control of a select pin in a dual
configuration. The aAM3202 has an inverted switch logic
compared to the aAM3203. The parts are available in a
10-contact leadless QFN package and operate over the
range from 1.8V to 5.5V.
Features (at 5V VDD)
•
Low On-Resistance: 4Ω Max
•
Guaranteed On-Resistance Match Between
Channels, < 0.4Ω
IN1
1
10 COM1
NO1
2
9
NC1
GND
3
8
VDD
7
NC2
COM2
aAM3202
NO2
4
IN2
5
6
IN1
1
10 COM1
NC1
2
9
NO1
GND
3
8
VDD
NC2
4
7
NO2
IN2
5
6
COM2
aAM3203
Functional Diagrams
•
Guaranteed Flat On-Resistance Over Specified
Signal Range, < 1.2Ω.
•
Turn-On Time: 12nS at 25°C
IN1
•
Turn-Off Time: 5nS at 25°C
NO1
•
Break Before Make Interval: 7nS typ
•
Temperature Range: -40°C to 85°C
•
Uses a Single Supply, 3V to 5V Nominal
GND
COM1
NC1
aAM3202
VDD
NC2
NO2
IN2
COM2
IN1
COM1
Applications
•
Mobile Communications
•
Computers and Peripherals
•
Battery Management
•
FAX Machines/Printers/Copiers
•
Portable Medical Instruments
NC1
GND
NC2
NO1
aAM3203
VDD
NO2
IN2
COM2
Part Marking
aAM3202
aAM3203
How Supplied
3000 units on T&R
3000 units on T&R
Ordering Information
Part Number
aAM3202Q10
aAM3203Q10
Package
10-Lead QFN
10-Lead QFN
© Andigilog, Inc. 2004
Temperature Range
-40˚C to +85˚C
-40˚C to +85˚C
www.andigilog.com
February 2004 – 70A04013_001
Preliminary Specification
- Subject to change without notice
Preliminary Specification
General Description
- Subject to change without notice
PRODUCT SPECIFICATION
Preliminary Specification
aAM3202 / aAM3203
NOTES:
Rating
+7V
-0.5V to VDD + 0.5V
-0.5V to +7V
50mA
-60°C to +150°C
260°C
2000V
250V
TBD
260°C
1.
Absolute maximum ratings are limits beyond
which operation may cause permanent
damage to the device. These are stress
ratings only; functional operations at or above
these limits is not implied.
2.
Human Body Model: 100pF capacitor
discharged through a 1.5kΩ resistor into each
pin. Machine Model: 200pF capacitor
discharged directly into each pin.
3.
These specifications are guaranteed only for
the test conditions listed.
Recommended Operating Ratings
Symbol
VDD
VNO, VNC, VCOM
TA
Parameter
Supply Voltage
Analog Signal Level
Operating Temperature Range
Min
+1.8
0
-40
Max
+6
VDD
+85
Units
V
V
°C
DC Electrical Characteristics (Digital section)3
Limits apply for -40°C ≤ T A ≤ +85°C and V D D = + 5.0V unless otherwise noted.
Parameter
Min Hi-Level Input
Voltage
Max Low-Level
Input Voltage
Digital Input
Leakage
Digital Input Power
OFF Leakage
Symbol
Conditions
VIH
-40°C≤TA≤+85°C
VIL
-40°C≤TA≤+85°C
IIN
IOFF
VADD & VEN = 0V or +5.5V
VDD = +5.5V
VADD & VEN = 0V or +5.5V
VDD = 0V
VDD=+2.7V
VDD=+4.5V
VDD=+2.7V
VDD=+4.5V
TA=+25°C
TA=-40°C to+85°C
TA=+25°C
TA=-40°C to+85°C
Min
2.0V
2.4V
Max
Units
V
0.4V
0.8V
0.1
1.0
0.1
1.0
-0.1
-1.0
-0.1
-1.0
V
μA
μA
DC Electrical Characteristics (Analog Section)3
Limits apply for -40°C ≤ T A ≤ +85°C and V D D = + 5.0V unless otherwise noted.
Parameter
Symbol
ON-Resistance
RON
ON-Resistance
channel matching
ON-Resistance
Flatness
Supply Current
∆RON
RFLAT
IDD
Conditions
TA=+25°C
INO = -10mA
VCOM = 0V to +5V
TA=-40°C to+85°C
TA=+25°C
INO = -10mA
VCOM = 0V to +3V
TA=-40°C to+85°C
INO = -10MA, VDD=+4.5V
TA=+25°C
TA=-40°C to+85°C
VCOM = 0 to VDD
INO = -10MA, VDD=+2.7V
TA=+25°C
VCOM = 0 to VDD
TA=-40°C to+85°C
TA=+25°C
INO = -10mA, VDD=+5V
VCOM = +1V, +2.5V, +4V
TA=-40°C to+85°C
TA=+25°C
INO = -10mA, VDD=3V
VCOM = +.6V, +1.5V, +2.4V
TA=-40°C to+85°C
TA=+25°C
VDD=+3.3V or +5.5V,
VADD & VEN = 0V
TA=-40°C to+85°C
Min
Typ
2
Max
4
4
7
0.1
0.4
0.1
0.4
0.5
1.2
1.5
2.5
0.1
1
Units
Ω
Ω
Ω
Ω
Ω
Ω
μA
-2© Andigilog, Inc. 2004
www.andigilog.com
April 2004 – 70A04011
- Subject to change without notice
Parameter
Supply Voltage
Analog Input/Output Voltage
IN1/IN2 Input Voltage
Continuous Current, any terminal
Storage Temperature Range
Lead Soldering Temperature
Human Body Model
ESD2
Machine Model
Thermal Resistance - θJA
Lead Temperature
Preliminary Specification
Preliminary Specification
- Subject to change without notice
Absolute Maximum Ratings1
aAM3202 / aAM3203
Dynamic Electrical Characteristics3
Symbol
Turn-On Time
tON(EN)
Turn-Off Time
tOFF(EN)
Break-BeforeMake Interval
Logic Input Cap.
NO-off, NC-off-ch
Cap.
COM-On-ch Cap
Conditions
TA=+25°C
VDD = +5V, VNO = 3V
CL=35pF, RL=300Ω
TA=-40°C to+85°C
TA=+25°C
VDD = +3V, VNO = 2V
CL=35pF, RL=300Ω
TA=-40°C to+85°C
TA=+25°C
VDD = +5V, VNO = 3V
CL=35pF, RL=300Ω
TA=-40°C to+85°C
TA=+25°C
VDD = +3V, VNO = 2V
CL=35pF, RL=300Ω
TA=-40°C to+85°C
TA=+25°C
VDD = +5V, VNO = 3V
CL=35pF, RL=300Ω
TA=-40°C to+85°C
TA=+25°C
VDD = +3V, VNO = 2V
CL=35pF, RL=300Ω
TA=-40°C to+85°C
f = 1MHz
TA=+25°C, f = 1MHz
tOPEN
CIN
Min
Typ
12
Max
16
14
20
5
Units
ns
ns
ns
8
6
10
7
ns
ns
1
7
ns
1
8
pF
CNO(OFF)
f = 1MHz; VEN=VNO=0V
TA=+25°C, f = 1MHz
8
pF
CCOM(ON)
VEN = +2.4V; VCOM = 0V
TA=+25°C, f = 1MHz
32
pF
Test Circuits / Timing Diagrams
Figure 1. Switching Time
VDD
LOGIC
INPUT
VDD
VIN
VIN
IN
VNO
VCOM
NC
GND
300
SWITCH
OUTPUT VCOM
50%
50%
0V
VNO
aAM3202/03
NO
COM
50
tR = tF <5nS
VIH
90%
90%
0V
35pF
tON
tOFF
Figure 2. Break-Before-Make Interval
VDD
LOGIC
INPUT
VDD
VNO
VIN
VIH
VIN
NO, NC
IN
VDD
aAM3202/03
COM
50
GND
0V
VCOM
300
MUX
OUTPUT VCOM
35pF
0V
tR = tF <5nS
50%
90%
90%
tOPEN
-3© Andigilog, Inc. 2004
www.andigilog.com
April 2004 – 70A04011
- Subject to change without notice
Parameter
Preliminary Specification
Preliminary Specification
- Subject to change without notice
Limits apply for -40°C ≤ T A ≤ +85°C and V D D = + 5.0V unless otherwise noted.
aAM3202 / aAM3203
COM1 Connection
IN2
COM2 Connection
0
NC1
0
NC2
1
NO1
1
NO2
Packaging Information
This QFN package is lead-free.
0.900 ± 0.050
Pin 1 Dot
Marking
3.000 ± 0.050
3.000
± 0.050
SLP / QFN 10L
0.250 ± 0.050
Pin 1 Identification
R 0.200 TYP
0.250 ± 0.050
2.000
REF
(3mm x 3mm)
2.400 ± 0.050
Exposed Pad
0.500 bsc
0.000 - 0.050
1.700 ± 0.050
Exposed Pad
Top View
0.203 ± 0.025
Bottom View
Side View
Tape & Reel Dimensions
8.00 ± 0.10
2.00 ± 0.05 (Note 2.)
Ø 1.50 + 0.10
A
4.00 (Note 1.)
1.75 ± 0.10
0.3 ± 0.05
Ø 1.50 MIN
5.50 ± 0.05
12.00 ± 0.30
3.30
3.3 ± 0.10
3.30
1.1
A
SEC - AA
Notes:
1. 10 hole cumulative tol. ± 0.2
2. Measured to the true position of the pocket
Part
Orientation
-4© Andigilog, Inc. 2004
www.andigilog.com
February 2004 – 70A04011
- Subject to change without notice
IN1
Preliminary Specification
Preliminary Specification
- Subject to change without notice
Truth Table - aAM3202 or aAM3203
aAM3202 / aAM3203
Data Sheet Classifications
New Release Specification
This classification is shown on the heading of the first page only of a specification for products that are either
under the later stages of development (characterization and qualification), or in the early weeks of release to
production. Andigilog reserves the right to change the specification and information for these products without
notice.
Fully Released Specification
Fully released datasheets do not contain any classification in the first page header. These documents contain
specification on products that are in full production. Andigilog will not change any guaranteed limits without
written notice to the customers. Obsolete datasheets that were written prior to January 1, 2001 without any
header classification information should be considered as obsolete and non-active specifications, or in the best
case as Preliminary Specifications.
LIFE SUPPORT POLICY
ANDIGILOG'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES
OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF
ANDIGILOG, INC. As used herein:
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b)
support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in the
labeling, can be reasonably expected to result in a significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected
to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Andigilog, Inc.
8380 S. Kyrene Rd., Suite 101
Tempe, Arizona 85284-2120
Tel: (480) 940-6200
Fax: (480) 940-4255
-5© Andigilog, Inc. 2004
www.andigilog.com
February 2004 – 70A04013
- Subject to change without notice
This classification is shown on the heading of each page of a specification for products that are either under
development (design and qualification), or in the formative planning stages. Andigilog reserves the right to
change or discontinue these products without notice.
Preliminary Specification
Preliminary Specification
- Subject to change without notice
Preliminary Specification