ETC ATS50

aTS50
LOW-VOLTAGE SOT-23 TEMPERATURE SENSOR
PRODUCT SPECIFICATION
New Release Specification
General Description
Pin Configuration
The aTS50 is a high-precision CMOS temperature
sensor that provides a cost-effective solution for
applications requiring high-accuracy low-power
temperature monitoring. The aTS50 output voltage
ramp is extremely linear and has a slope of 10mV/°C.
With a supply voltage of 2.7V to 6V, the aTS50 is
accurate to ±1°C over a temperature range of −40°C to
125°C and has a typical room temperature accuracy of
±0.5°C. Reducing the supply voltage to 2.7V does not
change the negative and positive temperature
extremes. As well, the aTS50 does not require
external calibration. Calibration of each device is
performed at the factory.
SOT- 23 3-lead
1
VDD
aTS50
VOUT
3
GND
2
actual part marking below
Features
•
Precision Calibrated to ±1°C at 25°C
•
Temperature Range: -40°C to 125°C
•
Extremely Linear Output Ramp: 10mV/°C
•
Output Ramp is Calibrated to Degrees Celsius
•
Low Operating Current: ≤ 130μA
•
Low Self Heating: 0.2°C Typical in Still Air
•
Operating Voltage Range: +2.7V to +6V
•
Uses a Single Positive Supply
•
Non-linearity: ≤ 0.8°C
Applications
•
Accuracy vs Temperature
VDD =+5V
Accuracy (°C)
4
3
2
upper spec limit
1
0
-1
-2
-3
Mobile Phones
•
Mobile Communications Terminals
•
Computers
•
Battery Management
•
FAX Machines/Printers/Copiers
•
Portable Medical Instruments
•
HVAC
•
Power Supply Modules
•
Disk Drives
•
Automotive Control Circuits
-4
-50
lower spec limit
-40
25
0
50
100
125
Temperature (°C)
Ordering Information
Part Number
Package
Temperature Range
Part Marking
How Supplied
aTS50S3
3-Pin SOT-23
-40˚C to +125˚C
AAyw
3000 units on T&R
y – year, w - week
© Andigilog, Inc. 2003
www.andigilog.com
70A03202-003
aTS50
Absolute Maximum Ratings1
Parameter
Rating
Supply Voltage
+7V
Output Voltage
VDD + 0.5V
Continuous Current, any terminal
Storage Temperature Range
ESD2
10mA
-60°C to +150°C
Human Body Model
2000V
Machine Model
250V
Thermal Resistance - θJA
Lead
Temp
336°C/W
Vapor Phase (60 sec)
215°C
Infrared (15 sec)
220°C
Notes:
1. Absolute maximum ratings are limits beyond
which operation may cause permanent damage to
the device. These are stress ratings only;
functional operation at or above these limits is not
implied.
2. Human Body Model: 100pF capacitor discharged
through a 1.5kΩ resistor into each pin. Machine
Model: 200pF capacitor discharged directly into
each pin.
3. These specifications are guaranteed only for the
test conditions listed.
Recommended Operating Ratings
Symbol
Parameter
Min
Max
Units
VDD
Supply Voltage
+2.7
+6
V
VOUT
Output Voltage
0
VDD
V
-40
+125
°C
TA
Operating Temperature Range
Electrical Characteristics3
Limits apply for -40°C ≤ T A ≤ +125°C and V D D = + 5.0V unless otherwise noted.
Parameter
Symbol
4
Accuracy
Conditions
Min
Typ
Max
Units
TA=+25°C
TA=-40°C (TMIN)
TA=+125°C (TMAX)
-1
±0.5
+1
°C
-3
±1
+3
°C
±1
+3
°C
Non-linearity5
-3
±0.8
Supply Current – Output floating
°C
TA=+25°C
Output Sink Capability
IOL
+2.7V < VDD < +6V
50
μA
Output Source Capability6
IOH
+2.7V < VDD < +6V
50
μA
10
mV/°C
TA=+25°C
750
mV
SOT-23
0.21840
°C
Average Output Slope
AOUT
130
μA
IDD
6
(Sensor Gain)
Room Temperature Output
Voltage
Self Heating7
VOUT25
Notes:
4. Accuracy (expressed in °C) = Difference between calculated output voltage and measured output voltage.
Calculated output voltage = 10mV/°C multiplied by device’s case temperature at specified conditions of
temperature, voltage and power supply.
5. Non-linearity is defined as the deviation of the output-voltage-versus-temperature curve from the best-fit straight
line, over the device’s rated temperature range.
6. Lowest output current should be targeted; higher currents result in more self-heating of the device.
7. Max Self Heating = θJA x (VDD x IDD). Assumes a capacitive load.
© Andigilog, Inc. 2003
-2www.andigilog.com
70A03202-004
aTS50
VOUT (mV)
1750
1500
750
500
100
-50 -40
-25
0
25
50
75
100
125
Temperature (ºC)
Temp (ºC) = (VOUT – 500mV) / 10mV/ºC
Figure 1. aTS50 Output Voltage vs. Temperature
Mounting
The aTS50 can be easily mounted by gluing or
cementing it to a surface. In this case, its temperature
will be within about 0.2°C of the temperature of the
surface it is attached to if the ambient air temperature
is almost the same as the surface temperature. If the
air temperature is much higher or lower than the
surface temperature, the actual temperature of the
aTS50 die will be at an intermediate temperature
between the surface temperature and the air
temperature.
To ensure good thermal conductivity, the backside of
the aTS50 die is directly attached to the GND pin. The
lands and traces to the aTS50 will, of course, be part of
the printed circuit board, which is the object whose
© Andigilog, Inc. 2003
temperature is being measured. These printed circuit
board lands and traces will not cause the aTS50’s
temperature to deviate from the desired temperature.
Alternatively, the aTS50 can be mounted inside a
sealed-end metal tube, and can then be dipped into a
bath or screwed into a threaded hole in a tank. As
with any IC, the aTS50 and accompanying wiring and
circuits must be kept insulated and dry to avoid
leakage and corrosion. This is especially true if the
circuit may operate at cold temperatures where
condensation can occur. Printed-circuit coatings and
varnishes such as Humiseal and epoxy paint or dips
can be used to ensure that moisture cannot corrode
the aTS50 or its connections.
-3www.andigilog.com
70A03202-004
aTS50
Typical Performance Characteristics
VDD =+5V
Accuracy (°C)
4
3
2
upper spec limit
1
0
-1
-2
-3
lower spec limit
-4
-50
-40
25
0
50
125
100
Temperature (°C)
Figure 2. aTS50 Accuracy Range vs Temperature
130
VDD = +5V
120
110
100
90
IDD ( mA)
IDD (µA)
80
70
60
50
40
30
20
10
0
-50
-25
0
25
50
75
100
125
Temperature (°C)
Figure 3. aTS50 Current vs Temperature
© Andigilog, Inc. 2003
-4www.andigilog.com
70A03202-004
aTS50
Typical Applications
5V
3.9K
VTemp
aTS50
IN
Serial
REF Analog-to-Digital
Converter
1.75V
U1
U3
+
100K
FB
SERIAL
DATA OUT
Adjustable
Shunt Voltage
Reference
CLOCK
1μF
U2
10K
ENABLE
Figure 4. Serial Output Temperature to Digital Converter (Full Scale = +125˚C)
5V
30K
VTemp
aTS50
8
IN
U1
Parallel Output
Analog-to-Digital
Converter
_
U2
5K
+
PARALLEL
DATA
OUTPUT
1.75V
VREF
INTR
U3
1μF
CS
15K
RD
WR
Figure 5. Parallel Output Temperature to Digital Converter (Full Scale = +125˚C)
© Andigilog, Inc. 2003
-5www.andigilog.com
70A03202-004
aTS50
Typical Applications (cont.)
V+
R3
R4
R1
4.1V
Shunt
Voltage
Reference
VT
+
U1
U3
0.1μF
VOUT
–
R2
V+
aTS50
VTemp
U2
Figure 6. Thermostat/Fan Controller
© Andigilog, Inc. 2003
-6www.andigilog.com
70A03202-004
aTS50
SOT-23 Package Dimensions
0.370 mm (min)
0.510 mm (max)
2.100 mm (min)
2.640 mm (max)
1.200 mm (min)
1.400 mm (max)
0.450 mm (min)
0.600 mm (max)
2.800 mm (min)
3.040 mm (max)
0.890 mm (min)
1.120 mm (max)
0.013 mm (min)
0.100 mm (max)
0.085 mm (min)
0.180 mm (max)
1.780 mm (min)
2.050 mm (max)
0.55ref mm
Reel Data
W
A0
B0
K0
P0
P1
P2
T
F
B
© Andigilog, Inc. 2003
8.00 + 0.30 / -0.10 mm
3.15 ± 0.10 mm
2.77 ± 0.10 mm
1.22 ± 0.10 mm
4.00 ± 0.10 mm
4.00 ± 0.10 mm
2.00 ± 0.05 mm
0.29 ± 0.13 mm
3.50 ± 0.05 mm
-7www.andigilog.com
70A03202-004
aTS50
Data Sheet Classifications
Preliminary Specification
This classification is shown on the heading of each page of a specification for products that are either under
development(design and qualification), or in the formative planning stages. Andigilog reserves the right to
change or discontinue these products without notice.
New Release Specification
This classification is shown on the heading of the first page only of a specification for products that are either
under the later stages of development(characterization and qualification), or in the early weeks of release
to production. Andigilog reserves the right to change the specification and information for these products
without notice.
Fully Released Specification
Fully released datasheets do not contain any classification in the first page header. These documents contain
specification on products that are in full production. Andigilog will not change any guaranteed limits without
written notice to the customers. Obsolete datasheets that were written prior to January 1, 2001 without
any header classification information should be considered as obsolete and non-active specifications, or in
the best case as Preliminary Specifications.
Andigilog, Inc.
7404 W. Detroit St., Suite 100
Chandler, Arizona 85226-2422
Tel: (480) 940-6200
Fax: (480) 940-4255
© Andigilog, Inc. 2003
-8www.andigilog.com
70A03202-004
aTS50
Notes:
Andigilog, Inc.
7404 W. Detroit St., Suite 100
Chandler, Arizona 85226-2422
Tel: (480) 940-6200
Fax: (480) 940-4255
© Andigilog, Inc. 2003
-9www.andigilog.com
70A03202-004