ETC FFD1680120

Transmitter for Numerical Counter Signals
Type FFD 1680
•
•
•
•
•
•
•
•
Product Description
Dupline ® transmitters with
pulse input and 4-digit totalizing up-counter. Reset and
disable inputs. Detection, up-
Fieldbus
Installationbus
Transmitter with counter input
4-digit totalizing up-counter
Overflow indication
Reset input
D-housing
Plug-in type module
LED-indication for supply
AC or DC power supply
Ordering Key
counting and transmission of
low-frequency events for
readout, control, logging etc.
Du line
®
FFD 1680 024
Type: Dupline®
Input signal
Supply
Type Selection
Supply
Ordering no.
4-digit
counter
24 VAC
120 VAC
220 VAC
FFD 1680 024
FFD 1680 120
FFD 1680 220
10 to 30 VDC*
Code module
FMK A-B to O-P
* All AC types may be supplied with 10 to 30 VDC at pins 3 & 9
Input Specifications
Count input
Open loop voltage
Short-circuit current
Counting range
Counting direction
Input frequency
Contact resistance
Dielectric voltage
Input - Dupline®
Reset input
Open loop voltage
Short-circuit current
Operating time for signal "1"
Operating time for signal "0"
Contract resistance
Cable length
Dielectric voltage
Input - Dupline®
1 contact or NPN transistor
8 VDC
2 mA
0 to 9999
Up
≤ 25 Hz
≤ 100 Ω
None
1 contact or NPN transistor
8 VDC
2 mA
≤ 1 pulse train + 20 ms
≤ 1 pulse train + 20 ms
≤ 100 Ω
≤3m
Transmission disable input
Open loop voltage
Short-circuit current
Operating time for signal "1"
Operating time for signal "0"
Contact resistance
Cable length
Dielectric voltage
Input - Dupline®
1 contact or NPN transistor
8 VDC
2 mA
≤ 1 pulse train + 10 ms
≤ 1 pulse train + 10 ms
≤ 100 Ω
≤3m
None
None
Specifications are subject to change without notice (28.09.99)
Dupline® is a registered trademark. A product of the CARLO GAVAZZI Group
1
Du line
FFD 1680
®
Fieldbus
Supply Specifications
General Specifications
Power supply AC types
Rated operational voltage
through pins A1 & A2 220
120
024
Frequency
Voltage interruption
Rated operational power
Rated operational
withstand voltage
220
120
024
Dielectric voltage
Supply - Dupline®
Supply - Count input
Supply - Reset/Disable input
Alternative DC supply
Supply voltage (VDD in)
through pins 3 & 9
Ripple
Reverse polarity protection
Rated operational current
Inrush current
Rated operational withstand
voltage
Dielectric voltage
Supply - Dupline®
Supply - Count input
Supply - Reset/Disable input
Power ON delay
Indication for
Supply ON
Environment
Degree of protection
Pollution degree
Operating temperature
Storage temperature
Humidity (non-condensing)
Mechanical resistance
Shock
Vibration
Dimensions
Material
(see "Technical Information")
Weight
Approvals
Overvoltage cat. III (IEC 60664)
230 VAC +6%, -15% (IEC 60038)
120 VAC ± 10% (IEC 60038)
24 VAC ± 10%
45 to 65 Hz
≤ 40 ms
Typ. 2.5 VA
4 kV
2.5 kV
800 V
≥ 2 kVAC (rms)
≥ 2 kVAC (rms)
≥ 2 kVAC (rms)
Overvoltage cat. III (IEC 60664)
10 to 30 VDC (ripple included)
≤3V
Yes
≤ 20 mA
≤1A
Installationbus
Undefined, ≤ 1 s
LED, green
IP 20 B
3 (IEC 60664)
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to +185°F)
20 to 80%
15 G (11 ms)
2 G (6 to 55 Hz)
D-Housing
200 g
CSA
800 V
None
None
None
Mode of Operation
Transmitters with 4-digit
pulse counting function. The
module features reset and
transmission disable inputs.
For every digit the most significant bit of the BCD equivalent influences the lowest of
the 4 allocated channels.
The accumulated counting
value is transmitted in BCD
representation on the Dupline.
This implies that every digit
uses 4 channels. The-digitto-channel allocation is as
follows (example with FFD
1680 and FMK C-D plugged
in):
Activation of the reset function (pin 3 connected to pin 1)
always resets the internal
counter to 0, irrespective of
the disable and counting inputs.
100 on highest 4 selected
channels (e.g. D5-8).
101 on lower 4 channels of
higher group (e.g. D1-4).
102 on higher 4 channels of
lower group (e.g. C5-8).
103 on lowest 4 selected channels (e.g. C1-4).
2
When the transmission disable function is activated (pin
3 connected to pin 5), the
transmitter does not transmit
its value via the Dupline®
whereas the internal counter
can still operate.
A Dupline® system can have
several FFD 1x80s coded to
the same channel groups. In
this case the counting values
may only be emitted from
one transmitter at a time, the
other transmitters must be
disabled in the meantime. This
feature is best obtained by
using Dupline® receivers with
demultiplex output type D
1230 5111 connected to the
transmission disable inputs.
FK3C 7640 and FL3C 7640
or D 6369 6475 can be used
for display of FFD 1680 values. FK3C 7760 and FL3C
7760 can be used for display
of FFD 1780 values.
Note: If DC-supplied FFD ....
transmitters are used, the
length of the supply bus must
not exceed 3 m in order to
avoid disturbances unbalancing the Dupline®.
Note: Transmitters for numerical signals must not be
used in systems where channel generators with 2 or 3 sequences are installed.
Overflow: When the counter
reaches 9999 (999999), the
transmitter activates all coded
channels, thereby causing
Dupline® displays to become
dark.
Specifications are subject to change without notice (28.09.99)
Dupline® is a registered trademark. A product of the CARLO GAVAZZI Group
Du line
FFD 1680
®
Fieldbus
Installationbus
Operation Diagram
Power supply
Counter input
Reset input
Transmission Disable input
Transmission value
Wiring Diagram
Accessories
No conn.
Count input
Reset
Transmission Disable
VDD in
S: signal wire.
Socket◊
Socket cover
Hold down spring◊
Front mounting bezel
DIN-rail for D 411
D 411
BB 5
HF
FRS 2
FMD 411
For further information refer to "Accessories".
Power
Supply
Specifications are subject to change without notice (28.09.99)
Dupline® is a registered trademark. A product of the CARLO GAVAZZI Group