ETC HSA-X-2-40

Datasheet
HSA-X-2-40
2 GHz High-Speed Amplifier
Features
Bandwidth 10 kHz ... 2 GHz
Rise Time 180 ps
Gain 40 dB
Input VSWR 1 : 1.1
Integrated Bias Circuit
Applications
Preamplifier for ultra-fast Detectors (Microchannel-Plates, Photomultipliers,
Avalanche-Photodiodes and PIN-Photodiodes)
Oscilloscope and Transient-Recorder Preamplifier
Time-Resolved Pulse and Transient Measurements
Block Diagram
INPUT
OUTPUT
BIAS
DC-Path
50 Ohm
Ultra Wideband
Amplifier
Test Conditions
Vs = + 15 V, Ta = 25°C, System Impedance = 50 Ω
Gain
Gain
Gain Accuracy
Gain Flatness (overall)
40 dB
± 1 dB
± 0.3 dB
Frequency Response
Lower Cut-Off Frequency
Upper Cut-Off Frequency
10 kHz
2 GHz
Time Response
Rise / Fall Time (10% - 90%)
180 ps
Input
DC Input Impedance
RF Input Impedance
50 Ω Noise Figure
Equivalent Input Voltage Noise
Input VSWR
Maximum Input VSWR
50 Ω
50 Ω
5.1 dB
670 pV/√Hz
1 : 1.1
1 : 1.3
Output Impedance
Output Power P1dB
Output Peak-Peak Voltage
50 Ω
+ 10.5 dBm (@ f < 1 GHz)
1.9 Vpp
(@ f < 500 MHz, for linear Amplification)
Specifications
Output
(@ f < 1 GHz)
(@ f < 1 GHz)
(@ f < 1 GHz)
(@ f < 3 GHz)
SOPHISTICATED TOOLS FOR SIGNAL RECOVERY
DB-E-0602-10 / R 64 / SG / Date: 01.09.03 / 2 Pages
Datasheet
HSA-X-2-40
2 GHz High-Speed Amplifier
Power Supply
Supply Voltage
Supply Current
+ 15 V
+ 125 mA
Case
Weight
Material
100 gr. (0.23 lbs)
AlMg4.5Mn, nickel-plated
Temperature Range
Storage Temperature
- 40 ... + 100 °C
Operating Ambient Temperature 0 ... + 60 °C
Operating Case Temperature
40 °C
Absolute Maximum Ratings
Power Supply Voltage
DC and LF Input Voltage
RF Input Power
+ 20 V
±4V
+ 13 dBm
Connectors
Input
SMA
Output
SMA
Power Supply
LEMO Series 1S, 3-pin fixed Socket
Pin 1:
+ 15 V
Pin 2:
n.c.
Pin 3:
GND
PIN 2
PIN 1
+Vs
PIN 3
GND
Dimensions
OUT
43 mm
IN
POWER
22 mm
54 mm
M4
UNC 8-32
DZ01-0601-10
FEMTO Messtechnik GmbH
Paul-Lincke-Ufer 34
D-10999 Berlin Germany
Tel.: +49 (0)30 – 4 46 93 86
Fax: +49 (0)30 – 4 46 93 88
e-mail: [email protected]
http://www.femto.de
Specifications are subject to change without notice. Information furnished herin is believed to
be accurate and reliable. However, no responsibility is assumed by FEMTO Messtechnik
GmbH for its use, nor for any infringement of patents or other rights granted by implication
or otherwise under any patent rights of FEMTO Messtechnik GmbH. Product names
mentioned may also be trademarks used here for identification purposes only.
 by FEMTO Messtechnik GmbH
Printed in Germany
SOPHISTICATED TOOLS FOR SIGNAL RECOVERY
Page 2