SP25F SP50F SP75F SP100F 2,500 V - 10,000 V Rectifier Stacks 0.5 A Forward Current 150 ns Recovery Time ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS Part Number Working Reverse Voltage Average Rectified Current (in oil) (Io) (Vrwm) SP25F SP50F SP75F SP100F 55°C 100°C Volts Amps Amps 2500 5000 7500 10000 0.5 0.5 0.5 0.5 0.33 0.33 0.33 0.33 Reverse Current @ Vrwm Forward Voltage (Ir) (Vf) 25°C 1 Cycle Surge Current tp=8.3ms (Ifsm) Repetitive Surge Current (Ifrm) Reverse Recovery Time (1) (Trr) 25°C 25°C 25°C Case Length (L) 100°C 25°C µA µA Volts Amps Amps Amps ns in. 1.0 1.0 1.0 1.0 25 25 25 25 6.0 8.0 16.0 16.0 1.5 1.0 1.0 1.0 60 40 40 40 10 8 8 8 150 150 150 150 1.125 2.000 2.750 3.500 (1)Trr Testing: If=0.5A, Ir=1.0A, Irr=0.25A *Op. Temp.= -55°C to +150°C Stg. Temp.= -55°C to +150°C 2.00(50.80) MIN. .500 ±.020 (12.70 ±.50) L ±.020 0.51 ±.003 (1.30 ±.08) .250 ±.020 (6.35 ±.50) Dimensions: In. (mm) • All temperatures are ambient unless otherwise noted. • Data subject to change without notice. VOLTAGE MULTIPLIERS INC. 8711 W. Roosevelt Ave. Visalia, CA 93291 183 TEL 559-651-1402 FAX 559-651-0740 www.voltagemultipliers.com 8 SP25F SP50F SP75F SP100F MAXIMUM FORWARD CURRENT VS. TEMPERATURE 0.6 8 7 0.5 SP25F 6 Forward Voltage (V) Maximum Current (I) TYPICAL FORWARD VOLTAGE VS. FORWARD CURRENT AT 25°C 0.4 0.3 0.2 0.1 5 4 3 2 1 0 0 25 50 75 100 125 Ambient Temperature Temperature (°C) (C) 0 150 REVERSE CURRENT VS. TEMPERATURE AT Vrwm 1000 2 4 6 Forward Current (A) 8 10 TYPICAL FORWARD VOLTAGE VS. FORWARD CURRENT AT 25°C 20 18 SP75F SP100F Forward Voltage (V) Reverse Current (uA) 16 100 10 14 12 10 SP50F 8 6 4 2 1 0 25 50 75 100 Temperature (°C) Temperature (C) 125 0 150 184 1 2 3 Forward Current (A) 4 5