VMI 3110F

3102 - 3110
3102F - 3110F
3102UF - 3110UF
200 V - 1,000 V Three Phase Bridge
2.0 A Forward Current
70 ns - 3000 ns Recovery Time
ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS
Part Number
Working
Reverse
Voltage
Average
Rectified
Current
@TC
(Io)
(Vrwm)
55°C
100°C
Volts
Amps
Amps
3102
3106
3110
200
600
1000
2.0
2.0
2.0
1.2
1.2
1.2
3102F
3106F
3110F
200
600
1000
2.0
2.0
2.0
1.2
1.2
1.2
3102UF
3106UF
3110UF
200
600
1000
2.0
2.0
2.0
1.2
1.2
1.2
Reverse
Current
@ Vrwm
Forward
Voltage
(Ir)
(Vf)
25°C
1 Cycle
Surge
Current
tp=8.3ms
(Ifsm)
Repetitive
Surge
Current
(Ifrm)
Reverse
Recovery
Time
(1)
(Trr)
25°C
25°C
25°C
Thermal
Impd.
uJ-C
100°C
25°C
µA
µA
Volts
Amps
Amps
Amps
ns
°C / W
1.0
1.0
1.0
25
25
25
1.1
1.1
1.1
1.0
1.0
1.0
30
30
30
10
10
10
3000
3000
3000
22.0
22.0
22.0
1.0
1.0
1.0
25
25
25
1.3
1.3
1.3
1.0
1.0
1.0
25
25
25
6
6
6
150
150
150
22.0
22.0
22.0
1.0
1.0
1.0
25
25
25
1.7
1.7
1.7
1.0
1.0
1.0
25
25
25
5
5
5
70
70
70
22.0
22.0
22.0
(1)Trr Testing: If=0.5A, Ir=1.0A, Irr=0.25A *Op. Temp.= -55°C to +150°C Stg. Temp.= -55°C to +150°C
.42(10.67)
.18(4.57)
11
.09(2.29)
AC
AC
AC
AC
+
AC
.62
(15.75)
+
AC
_
22 AWG Tinned
Copper Wire
_
.19
(4.83)
.25(6.35)
1.00(25.4)
.87(22.10)
MIN.
Dimensions: In. (mm) • All temperatures are ambient unless otherwise noted. • Data subject to change without notice.
VOLTAGE MULTIPLIERS INC.
8711 W. Roosevelt Ave.
Visalia, CA 93291
251
TEL
559-651-1402
FAX
559-651-0740
www.voltagemultipliers.com
3102 - 3110 • 3102F - 3110F • 3102UF - 3110UF
MAXIMUM FORWARD CURRENT
VS. TEMPERATURE
2.5
2.5
2.0
Forward Voltage (V)
Maximum Current (I)
2
1.5
1
0.5
3100UF
3100F
1.5
3100
1.0
0.5
0
0.0
25
50
75
100
125
Temperature (°C)
(C)
Ambient Temperature
0
150
REVERSE CURRENT
VS. TEMPERATURE AT Vrwm
1000
Reverse Current (uA)
TYPICAL FORWARD VOLTAGE
VS. FORWARD CURRENT AT 25°C
100
10
1
25
50
75
100
Temperature (°C)
Temperature
(C)
125
150
252
1
2
3
4
5
6
Forward Current (A)
7
8
9