ETC USC-DINLSXSXR4HTX

Digital Panel Meters
Modular signal conditioner
Type USC-DIN
•
•
•
•
•
•
•
Multi-input modular signal’s conditioner
0.1% RDG basic accuracy
TRMS AC current and voltage measurements
AC/DC current measurements; selectable full scales
(200µA to 5A)
AC/DC voltage measurements; selectable full scales
(200mV to 500V)
°C or °F temperature measurements
(Pt100-250-500-1000, Ni100, TC J-K-S-T-E)
Resistance measurements; selectable full scales
(20Ω to 20kΩ)
Up to 4 independent alarm set-points (optional)
20mA/10VDC analog output (optional)
Serial port RS485 or RS232 (optional)
MODBUS, JBUS communication protocol
Front protection degree: IP 20
• Linearization of V and A inputs up to 16 points
•
•
•
•
•
Product Description
How to order
µp-based signal’s conditioner, for current, voltage, temperature and resistance
measurements. Measuring
ranges and functions easily
programmable from the PC
by means of optional UscSoft software available on
Model
Slot A
Slot B
Slot C
Slot D
Slot E
Options
request. UscSoft includes
programming, display and
min-max functions. Conditioner’s housing for DINRAIL mounting with front
protection degree: IP 20. All
displaying and programming
data are referred to UscSoft.
How to order
USC XXX XX XX XX X XX
UscSoft-kit
UscSoft-kit: software plus “UCOM1” communication cable for
programming USC by means of PC.
Type Selection
Slot A (measuring inputs)
Slot B (communication)
Slot C (communication and alarm)
Slot D (communication)
LSX: single channel input:
0.2-2-20mA DC/AC,
0.2-2-20V DC/AC
LSE/
LSF: single + AUX input :
0.2-2-20mA DC/AC;
0.2-2-20V DC/AC
HSX: single channel input:
0.2-2-5A DC/AC;
20-200-500V DC/AC
TRX: signal input: TC temperature probes: J-K-ST-E, Pt100-250-5001000 and resistance
0.02-0.2-2-20kΩ
XX:
SX:
SY:
XX:
R1:
XX:
None
AV(*): Single analogue output,
0 to 20mA DC and
0 to 10V DC
None
Serial port RS485
Serial port RS232
Options
XX:
TX:
None
Tropicalization
Specifications are subject to change without notice
USCDS040706
None
Single relay output,
(AC1-8AAC, 250VAC)
R2:
Dual relay output,
(AC1-8AAC, 250VAC)
R4:
Dual relay output,
(AC1-8AAC, 250VAC) +
dual open collector output (NPN, 100mA)
R5:
4 Relay outputs (AC15AAC, 250VAC)
AV(*): Single analogue output:
0 to 20mA DC and
0 to 10V DC
(*):
The two analogue
outputs cannot be
used at the same
time. It is possible to
plug in only one
module by signal
conditioner.
Slot E (power supply)
H:
L:
90 to 260V AC/DC
18 to 60V AC/DC
1
USC
USC architecture
AUXILIARY DIGITAL INPUTS
(FUTURE FUNCTION)
Remote programming by
means of PC
Measuring inputs:
l DC/AC: mA-mV-V
l DC/AC: A-V
l °C/°F: TC-Pt-Ni-Ω
Digital input:
l Alarm reset
Auxiliary power supply:
l 13V / 50mA DC
25V / 25mA CC
l 1 alarm
l 2 alarms l 4 alarms
ALARM OUTPUTS
COMMUNICATION
Analogue outputs:
l 1 x 20mA/10V DC
POWER SUPPLY
Serial ports:
l RS485
l RS232
INTERNAL BUS
MEASURING INPUTS +
DIGITAL INPUTS +
AUXILIARY POWER SUPPLY
90 to 260V AC/DC
18 to 60V AC/DC
Input Specifications
Analogue inputs
BQ LSX module
BQ LSE/LSF module
BQ HSX module
BQ TRX module
BQ TRX module
Digital inputs (CMD)
Number of inputs
Use
Contact reading signal
Close contact resistance
Open contact resistance
Insulation
Accuracy (RS485)
Additional errors
Humidity
Input frequency
Magnetic field
Temperature drift
Sampling rate
BQ LSX module
BQ LSE/LSF module
BQ HSX module
BQ TRX module
Measurement updating
Resolution of measurements
Max. and min. indications
2
Measuring module
1, mA and V DC/AC
1, mA and V DC/AC + AUX
1, A and V DC/AC
1, temperature
1, resistance
Incl. in the measuring module
1 (voltage-free)
Reset of latch alarms
BQ xxx: <0.1mA, <3.5V DC
BQ LSE/LSF: <2.5mA,
<14V DC
Max 1kΩ
Min 500kΩ
Non-insulated
See table “Measuring
accuracy”, temperature drifts
and minimum-maximum
indications”
0.3% RDG, 60% to 90% R.H.
0.4% RDG, 62 to 440 Hz
0.5% RDG @ 400 A/m
See table “Measuring
accuracy, temperature drifts and
maximum minimum indications”
500 samples/s @ 50Hz
500 samples/s @ 50Hz
500 samples/s @ 50Hz
500 samples/s @ 50Hz
200 msec @ 50 Hz
10.000 points (4-dgt)
See table “Measurement
accuracy, temperature drifts
Measurements
Coupling
Crest factor
Input impedance
Frequency
Overload
Compensation
RTD
TC
and max min indications”
Current, voltage, temperature and resistance. For the
current and voltage measurements: TRMS measurement of distorted sine
waves.
Direct.
≤3; APmax=1,7In; VPmax=1,7Un
See table “input
impedances and overloads”
40 to 440 Hz
See table “input
impedances and overloads”
Only temperature
measurement module.
- For Pt 100-250-500-1000,
3-wire connection: up to 10Ω
- For resistance measur. with
20Ω range: up to max 0.1Ω
- For resistance measurements
with ≥200Ωrange: up to max 10Ω
Internal cold junction, within
temperature range from
0 to +50°C.
Automatic or manual
compensation from 0 to 50°C.
Specifications are subject to change without notice
USCDS0407063
USC
Measurement accuracy, temp. drifts, max and min indications
All accuracies and min/max indications are referred to an ambient temp. range of 25°C ±5°C, rel. humidity ≤60% and scale ratio (electrical/displayed scale) equal to 1. The conversion into °F is obtained acting on the electrical/displayed scale ratio.
Min. indication (<)
Max. indicat. (<)
BQ LSX/
BQ LSE/
BQ LSF
DC: ±(0.1%RDG+3DGT)
0%to 25% FS;
-200µA to +200µA
±(0.1%RDG+2DGT)
-2mA to +2mA
25% to 110% FS.
-20mA to +20mA
DC/AC TRMS (45 to 65Hz)*:
±150 ppm/°C
-200mV to +200mV
±(0.3%RDG+3DGT)
-2V to +2V
0% to 25% FS;
-20V to +20V
±(0.3%RDG+2DGT)
25% to 110% FS.
- 200.0
- 2.000
- 20.00
- 200.0
- 2.000
- 20.00
+ 200.0
+ 2.000
+ 20.00
+ 200.0
+ 2,000
+ 20.00
BQ HSX
DC: ±(0.1%RDG+3DGT)
0% to 25% FS;
-200mA to +200mA
±(0.1%RDG+2DGT)
-2A to +2A
25% to 110% FS.
-5A to +5A
DC/AC TRMS ( 45 to 65Hz)*:
±150 ppm/°C
-20V to +20V
±(0.3%RDG+3DGT)
-200V to +200V
0% to 25% FS;
-500V to +500V
±(0.3%RDG+2DGT)
25% to 110% FS.
- 200.0
- 2.000
- 5.000
- 20.00
- 200.0
- 500.0
+ 200.0
+ 2.000
+ 5.000
+ 20.00
+ 200.0
+ 500.0
BQ TRX
Thermocouple
-50°C to +760°C
-58 °F to +1400 °F
-200°C to +1260°C
-328 °F to +2300°F
-200°C to +1000°C
-328°F to +1832°F
-50°C to +1750°C
-58°F to +3182°F
-200°C to +400°C
-328°F to +752°F
±150 ppm/°C
- 50°C
- 58°F
- 200°C
- 328°F
- 200°C
- 328°F
- 50°C
- 58°F
- 200°C
- 328°F
+ 760°C
+ 1400°F
+ 1260°C
+ 2300°F
+ 100°C
+ 1832°F
+ 1750°C
+ 3182°F
+ 400°C
+ 752°F
BQ TRX
Thermoresistance
-200°C to +850°C Pt100
-328°F to +1562°F Pt100
-200.0°C to +200.0°C Pt100
-328°F to +392°F
Pt100
-200.0°C to +200.0°C Pt250
-328°F to +392°F
Pt250
-200.0°C to +200.0°C Pt500
-328°F to +392°F
Pt500
-200.0°C to +200.0°C Pt1000
-328°F to +392°F Pt1000
-60°C to +180°C
Ni100
-76°F to +356°F
Ni100
±150 ppm/°C
- 200
- 328
- 200.0
- 328
- 200.0
- 328
- 200.0
- 328
- 200.0
- 328
- 60
- 76
+ 850
+ 1562
+ 200.0
+ 392
+ 200.0
+ 392
+ 200.0
+ 392
+ 200.0
+ 392
+ 180
+ 356
±150 ppm/°C
0
0
0
0
20.00 (<)
200.0 (<)
2000 (<)
20.00 (<)
Module
BQ TRX
Resistance
Inputs
0 to 20Ω
0 to 200Ω
0 to 2000Ω
0 to 20.00kΩ
Type
J
J
K
K
E
E
S
S
T
T
Ω
Accuracy
±(0.2%RDG+1DGT)
±(0.2%RDG+2DGT)
±(0.2%RDG+2DGT)
±(0.2%RDG+4DGT)
±(0.2%RDG+2DGT)
±(0.2%RDG+4DGT)
±(0.2%RDG+2DGT)
±(0.2%RDG+4DGT)
±(0.2%RDG+2DGT)
±(0.2%RDG+4DGT)
±(0.2%RDG +2DGT)
±(0.2%RDG +4DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +5DGT)
±(0.5%RDG +1DGT)
±(0.5%RDG +2DGT)
±(0.2%RDG+2DGT)
25% to 110% FS
±(0.2%RDG+3DGT)
0% to 25% FS
Temp. drift
(*) <45Hz, >65Hz: ±(0.5%RDG+3DGT) 0% to 25% FS; ±(0.5%RDG+2DGT) 25% to 110% FS.
(<) The min. indication for TRMS measurement (AC or DC) is 0; it is possible to modify the decimal point position.
Specifications are subject to change without notice
USCDS040706
3
USC
Input impedances and overloads
Module
Inputs
Type
Impedance
Overload (continuous)
Overload (1s)
BQ LSX/
BQ LSE/
BQ LSF
-200µA to +200µA
-2mA to +2mA
-20mA to +20mA
-200mV to +200mV
-2V to +2V
-20V to +20V
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
≤2.2kΩ
≤22Ω
≤22Ω
≥2.2kΩ
≥200kΩ
≥200kΩ
5mA
50mA
50mA
10V
50V
50V
10mA
150mA
150mA
20V
100V
100V
BQ HSX
-200mA to +200mA
-2A to +2A
-5A to +5A
-20V to +20V
-200V to +200V
-500V to +500V
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
≤1Ω
≤0.012Ω
≤0.012Ω
≥2MΩ
≥2MΩ
≥2MΩ
0.8A
7.5A
7.5A
750V
750V
750V
1A
100A
100A
1000V
1000V
1000V
-50°C to +760°C
-58 °F to +1400 °F
-200°C to +1260°C
-328 °F to +2300°F
-200°C to +1000°C
-328°F to +1832°F
-50°C to +1750°C
-58°F to +3182°F
-200°C to +400°C
-328°F to +752°F
J
J
K
K
E
E
S
S
T
T
ILK <0.5µA
Max 5V
Max 10V
-200°C to +850°C
-328°F to +1562°F
-200,0°C to +200,0°C
-328°F to +392°F
-200,0°C to +200.0°C
-328°F to +392°F
-60°C to +180°C
-76°F to +356°F
Pt100
Pt100
Pt250/Pt100
Pt250/Pt100
Pt1000/Pt500
Pt1000/Pt500
Ni100
Ni100
800µA (*)
800µA (*)
90µA (*)
90µA (*)
800µA (*)
800µA (*)
800µA (*)
800µA (*)
Max 5V
Max 10V
Ω
800µA (*)
90µA (*)
800µA (*)
90µA (*)
Max 5V
Max 10V
BQ TRX
Thermocouple
BQ TRX
Thermoresistance
BQ TRX
Resistance
0 to 20Ω
0 to 200Ω
0 to 2000Ω
0 to 20.00kΩ
Output specifications
RS422/RS485
Serial output
LED
Connections
Distance
Terminalization
Addresses
Protocol
Data (bidirectional)
Dynamic (reading only)
Static (reading/writing)
(on request)
Module: BR SX
Bidirectional (static and
dynamic variables).
Display of data
reception/transmission
Multidrop, 2 or 4 wires,
1000m
Directly on the module
by means of jumper
1 to 255, selectable
by means of software
MODBUS RTU/JBUS
Data format
Baud rate
Insulation
8 data bit, no parity,
1 stop bit
selectable 4800, 9600,19200
and 38400 bit/s
By means of opto-couplers
4000 V output to
measuring inputs
4000 V output to
power supply input
(on request)
Module: BR SY
Bidirectional (static and
dynamic variables)
3 wires,
max. 15m
1 start bit, 8 data bit,
no parity, 1 stop bit
selectable 4800, 9600,
19200 and 38400 bit/s
As per RS422/485
rms
rms
RS232
Serial output
Connections
Distance
Data format
Measurement, min value
max value
alarm status
All programming parameters,
min max reset
Baud rate
Other characteristics
(*) Max. generated measuring current for resistance equal to 0Ω
4
Specifications are subject to change without notice
USCDS0407063
USC
Output characteristics (continuous)
Alarm output
Alarm type
Alarm set-point
Hysteresis
On-time delay
Off-time delay
Output status
Min response time
Output channels
BO R1, R2, R4 relay outputs
BO R5 relay output
Insulation
(on request)
Over-range alarm,
up alarm,
down alarm,
down alarm with
start-up deactivation
up alarm with latch,
down alarm with latch
Adjustable from 0 to 100%
of displayed electric range
0 to 100% of displayed range
0 to 255 s
0 to 255 s
Selectable: normally energized
/de-energized
500 ms, with filter excluded,
without alarm activation delay
1 with module BO R1
(relay output).
2, independent with module
BO R2 (2 relay outputs).
4, independent with module
BO R4 (2 relay outputs +
2 open collector outputs).
BO R5 (4 relay outputs).
Type SPDT
AC 1: 8A, 250VAC
DC 12: 5A, 24VDC
AC 15: 2.5A, 250VAC
DC 13: 2.5A, 24VDC
Type SPST (NO)
AC 1: 5A, 250VAC
DC 12: 3A, 24VDC
AC 15: 1.5A, 250VAC
DC 13: 1.5A, 24VDC
4000 VRMS output to
measuring input,
4000 VRMS output to
power supply input.
Open collector output
Insulation
Single analogue output
Range
Scaling factor
Accuracy
Response time
Termperature drift
Load: 20 mA output
10 V output
Insulation
NPN transistor type
VON 1.2 VDC/ max. 100 mA
VOFF 30 VDC max.
By means of opto-couplers
4000 VRMS output to
measuring input
4000 VRMS output to
power supply input
(on request)
Module: BO AV
0 to 20 mADC, 0 to 10 VDC
Programmable within the
entire retransmission range;
allows to manage the
retransmission of all the
values from
0 to 20 mA / 0 to 10V
± 0.2% FS (@ 25°C ± 5°C)
≤ 10 ms
± 200 ppm/°C
≤ 700 Ω
≥ 10 kΩ
By means of opto-couplers
4000V output to
measuring input
4000V output to
power supply input
The two outputs cannot be
used at the same time.
(on request)
rms
rms
Notes:
Excitation output
BQ LSE Module
Voltage
BQ LSF Module
Voltage
Insulation
13 VDC ±10%
max. 50 mA
25 VDC ±10%
max. 25 mA
25V output to
measuring input
4000 V output to
power supply input
rms
rms
Software functions
Min / Max storage
Measurement selection
Integration time selection
Scaling factors
Operating mode
Automatic storage
(in the EEPROM) of the
minimum and maximum
measured value from the
previous memory reset
Depending on the module:
measuring range and type of
probe (resistance, RTD
thermoresistance, TC
thermocouple) or measuring
type (TRMS or DC).
Automatic or from 100.0 to
999.9 ms only in the current
and voltage measurement.
Electrical scale compression,
Specifications are subject to change without notice
USCDS040706
displayed scale
compression/expansion
(max. 2 without filter, up to
10 with filter)
Programmable within the
Electrical range
whole measuring range
Decimal point position
Programmable within the
display range
Displayed range of the variable Programmable within the
display range
Diagnostics (only with Usc Soft) The display flashes when the
limits of the display range
are exceeded and the data
are updated up to 20%
of the rated display range.
Only temperature inputs
Burn-out:
5
USC
Software functions (continuous)
TC
RTD
Digital filter
Filter operating range
Filtering coefficient
Scaling
Opening of probe’s
connection: EEE indication
Opening of probe’s
connection: EEE indication
probe’s short circuit:
-EEE indication.
Linearization
Points
Input range
Output range
UscSoft
0 to 9999
1 to 32
Selection of min value
of the input range.
Selection of max value of
the input range.
Selection of decimal point
position.
Selection of min
display value.
Selection of max display
value.
Up to 16
Selectable by every
single point
Selectable by every
single point
Software for
programming USC
by means of PC (Windows 95,
98se, ME, XP) by means of
serial port RS485 and
relevant connection cable.
UscSoft includes
programming, displaying,
min-max storage functions.
The software is available in
English, Spanish, Italian,
German and French. See
also “The programming of
USC by means of PC”.
General Specifications
Operating
temperature
Storage
temperature
Insulation reference
voltage
Insulation
Dielectric strength
Rejection
NMRR
CMRR
EMC
0° to 50°C (32° to 122°F)
(H.R. < 90% non-condensing)
-10° to 60°C (14° to 140°F)
(H.R. < 90% non-condensing)
300 VRMS to ground
(500V input)
See table “Insulation between
inputs and outputs”
4000 VRMS for 1 minute
40 dB, 40 to 60 Hz
100 dB, 40 to 60 Hz
Safety Standards
Safety
Connections
Wire section
Housing
Dimensions
Material
Protection degree
Weight
Approvals
EN 61010-1, IEC 61010-1
Screw type
Max 2.5mm2
44 x 113 x 107 mm
PC-ABS,
self-extinguishing: UL 94 V-0
IP20
560 g approx (included all
modules and packing)
CE, UR, CSA
EN61000-6-2, IEC61000-6-2
EN61000-6-3, IEC61000-6-3
Supply Specifications
AC/DC voltage
6
90 to 260V (standard)
18 to 60V (on request)
Energy consumption
≤ 30VA/12W (90 to 260V)
≤ 20VA/12W (18 to 60V)
Specifications are subject to change without notice
USCDS0407063
USC
Excitation output
Insulation between inputs and outputs
Meas.
inputs
V
Relay Static Analogue Serial
AUX 90-260VAC/ 18-60VAC/
output output output
Port p.supply DC p. supply DC p.supply
Meas.
inputs
-
4kV
4kV
4kV
4kV
25V
4kV
4kV
Relay Output
4kV
-
2kV
4kV
4kV
4kV
4kV
4kV
Static Output
4kV
2kV
-
4kV
4kV
4kV
4kV
4kV
Analogue
Output
4kV
4kV
4kV
-
4kV
4kV
4kV
4kV
10
Serial Port
4kV
4kV
4kV
4kV
-
4kV
4kV
4kV
5
AUX
p.supply
25V
4kV
4kV
4kV
4kV
-
4kV
4kV
90/260VAC/
DC p. supply
4kV
4kV
4kV
4kV
4kV
4kV
-
-
18-60VAC/
DC p. supply
4kV
4kV
4kV
4kV
4kV
4kV
-
-
max. 30 s.
Continuous
30
25
BQ
LS
F
20
15
BQ LSE
0
10
20
30
40
50
60
mA
Available modules
Type
Possible module combinations
N. of
channels
USC main unit
DC/AC input: 200µA , 2mA, 20mA,
200mV, 2V, 20V
DC/AC input: 200µA , 2mA, 20mA,
200mV, 2V, 20V + excitation output
DC/AC input: 200mA, 2A, 5A,
20V, 200V, 500V
Input: 20Ω, 200Ω, 2kΩ, 20kΩ
TC: J-K-S-T-E, Pt100-250-500-1000, Ni100
Analogue output 0 to 20mA, 0 to 10V
Relay output
Relay output
Outputs: 2 relays + 2 open collectors
Relay output
RS485 Serial Port
RS232 Serial Port
Power supply 18 to 60V AC/DC
Power supply 90 to 260V AC/DC
Ordering
code
BD XX
1
BQ LSX
1
BQ LSE/
BQ LSF
1
BQ HSX
1
1
1
1
2
4
4
1
1
BQ TRX
BQ TRX
BO AV
BO R1
BO R2
BO R4
BO R5
BR SX
BR SY
BP L
BP H
Basic Unit
A
B
Slot
C
D
E
Measuring inputs:
LSX, LSE, LSF, HSX, TRX
RS485 serial port: SX
RS232 serial port: SY
Analogue output: AV (*)
Relay outputs and/or open
collector: R1, R2, R4, R5
Power supply: H, L
(*) Up to 1 module max.
Used calculation formulas
Only for TRMS Measurements
Instantaneous effective
voltage (TRMS)
V1 =
1
×
n
n
å
Specifications are subject to change without notice
1
( V 1 ) i2
USCDS040706
Instantaneous effective
current (TRMS)
A1 =
n
1
× å ( A 1 ) i2
n
1
7
USC
Wiring diagrams
Process signal wiring diagrams
BQ LSE/LSF
Fig. 3
+
+ Vdc
-
+
+ Vdc
-
Voltage measurements
3-wire connection to probe
Probe power supply Probe Signal output
Probe
Fig. 4
Voltage measurements
4-wire connection to probe
˜
BQ LSE/LSF
Fig. 5
+
+ Vdc
-
Current measurements
4-wire connection to probe
BQ LSE/LSF
Fig. 6
Probe Signal output
BQ LSE/LSF
+
Probe power supply
˜
Probe
˜
Voltage measurements
+
Probe
˜
Current measurements
Probe power supply Probe Signal output
Fig. 2
+
+ Vdc
-
Current measurements
3-wire connection to probe
Probe Signal output
BQ LSX/LSE/LSF
Probe
Fig. 1
Probe power supply
BQ LSX/LSE/LSF
Wirings for high-level signals
BQ LSE/LSF
Current measurements
2-wire connection to probe
8
+
+ Vdc
Probe power supply Probe Signal output
Probe
Fig. 7
BQ HSX
Fig. 8
+
Current measurements ˜
˜
BQ HSX
+
Voltage measurements ˜
Specifications are subject to change without notice
Fig. 9
˜
USCDS0407063
USC
Wiring diagrams (cont.)
Wiring diagrams for temperature measurements
BQ TRX
Fig. 10
BQ TRX
Fig. 11
Temp. measur. from thermoresistance
Temp. measur. from thermocouple
BQ TRX
Fig. 12
Resistance measurements
Wiring diagrams for power supply
BP H: power supply
BP L: power supply
F1= 630mA T
250V 5x20mm
F1= 3.15A T
250V 5x20mm
Wiring diagrams of optional modules
BO AV: single analogue
output (10V, 20mA)
BO R1: 1 relay output
Specifications are subject to change without notice
USCDS040706
BO R2: 2 relay outputs
BO R5: 4 relay outputs
9
USC
Wiring diagrams of optional modules (cont.)
BO SY: RS232 direct
connection to PC by
means of COM port.
RS232 has no terminalization.
TX
Vdc
RX
SY
LED
GND
5
RX
3
2
TX
1
3
2
5
9
1
6
BO R4: dual relay output +dual open collector output:
the load resistances (Rc) must be designed so that the close contact current is lower than 100mA; the VDC voltage must
be lower than or equal to 30VDC.
VDC: power supply output
Vo+: positive output (open collector transistor).
GND: ground collector (open collector transistor).
RS1,2,3...N
NON terminalized network.
Terminalized network
BR SX: RS485 4-wire connection: additional devices provided with RS485 port (indicated as RS1,2,3...N) are connected
in parallel. The termination of the serial port is carried out only on the last instrument of the network. The serial module is
provided with a jumper for the termination of the RS485 network as shown in the figure above.
Note: particular types of cables or plants may require an external termination. For the network connections use twisted
cable type AWG26.
Programming USC by means of PC
To USC
1
1m
USC is programmable by PC by means of the UscSoft software (available on
request). The user can program all parameters of USC that will be subsequently
uploaded and set in the instrument by the RS485 network (BR SX).
Should USC be without the RS485 serial module, all programming parameters
will be uploaded and set in the instrument by the RS232 auxiliary serial connection (1) located on the side of the measuring input module using the special connection cable (2) available on request, as shown in the figures on the left. It is
also possible to program the instrument using the connector (1) by means of the
HyperTerminal Windows functions of a PC.
2
Note: the RS232 auxiliary port IS NOT insulated from the measuring inputs.
Ordering code of the cable (2): UCOM1
To PC
10
Specifications are subject to change without notice
USCDS0407063
USC
Dimensions
113 mm
44 mm
44 mm
107 mm
Dimensions of optional module in scale 1:1
Specifications are subject to change without notice
USCDS040706
11
USC
Modules
Input modules
Output modules
BQ LSX, BQ LSE,
BQ LSF, BQ HSX,
BQ TRX
Measuring inputs
BO AV
Single analogue
output 10V, 20mA
Output modules
BO R1
Single relay output
BO R2
Dual relay output
Serial port modules
BR SX
RS485 Serial port
12
BO R4
Dual relay output +
Dual open collector
BO R5
4-relay output
Power supply modules
BR SY
RS232 Serial port
BP H
Power supply:
60 to 260V AC/DC
Specifications are subject to change without notice
BP L
Power supply:
18 to 60V AC/DC
USCDS0407063