ETC WR12D15/1000U

WR-U SERIES
Single and dual output
•
•
•
•
•
30 Watts output power
UL approved (48V input models)
2:1 input range
Efficiency to 86%
Isolated outputs
The WR-U series DC/DC converters accept a wide input voltage range of 9 to
18VDC, 18 to 36VDC, and 36 to 72VDC. A 100kHz switching regulator produces
operating efficiencies as high as 86% with output loads as light as 25% of full
load. These 30 Watt models provide for remote sensing, input/output isolation of
500VDC minimum, and short circuit protection. The WRU Series incorporates
six sided continuous EMI/RFI shielding. The “U” package measures 2.56 x 4.56
x 0.83 inches and is PCB mountable. Other pertinent specifications include:
overvoltage protection on all outputs, operating temperature range of –25°C to
71°C with no derating required and all models are free-air convection cooled.
[ 2 YEAR WARRANTY ]
SPECIFICATION
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
INPUT SPECIFICATIONS CONTINUED
Voltage accuracy
±1.0%
Voltage adjustability
Singles
±10%, max.
Remote sense
Singles
Yes
Line regulation
LL-HL, all outputs
±0.2%, max.
Load regulation
FL-NL
FL-0.25%FL
±5.0%, max.
±1.0%, max.
Voltage balance
Duals
Ripple and noise
5Hz to 20MHz
75mV pk-pk
10mV rms, max.
Transient response
25% step load
change
±1.0% error band
500µs rec.
Remote ON/OFF
Logic compatibility
Ec-ON
Ec-OFF
Shutdown idle current
Input resistance
Control common
CMOS or open collector TTL
+5.5VDC min. or open-circuit
max. 1.8VDC
5mA
0VDC <Ein< 9VDC; 100kΩ
Referenced to input minus
GENERAL SPECIFICATIONS
Efficiency
Typical
Temperature coefficient
Isolation voltage
See Note 5
Input/Output
Input/Case
Switching frequency
Fixed
100kHz
Approvals and
standards
Safety
UL1950
500VDC
250VDC
±0.02%/°C, max.
Case material
Overvoltage protection
75% to 86%
±2.0%
Single +5V output
Single +12 and+15V
Duals
Short circuit protection
6.8V ±10%
18.0V ±10%
No
Continuous
automatic recovery
Black coated copper with
non-conductive base
Material flammability
UL94V-0
Weight
MTBF
390g (13.77oz)
See Note 6
840,000 hours
INPUT SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Input voltage range
12VDC
24VDC
48VDC
9 to 18VDC
18 to 36VDC
36 to 72VDC
No load input current
12VDC
24VDC
48VDC
30mA
25mA
20mA
Input filter
See Note 7
Single outputs
Dual outputs
Reverse voltage
protection
Pi filter
Low ESR cap
Internal shunt diode
(Use external fuse)
Thermal performance
Operating ambient
-25°C to +71°C
Non-operating amb. -55°C to +105°C
Case, temp. rise
+30°C at FL max.
Derating
None required
Cooling
Free-air convection cooled
Relative humidity
Non-condensing
Altitude
Operating
Non operating
10,000 feet max.
40,000 feet max.
Vibration, Pressure
5Hz to 500Hz
2.5G rms (approx.)
5% to 95% RH
Data Sheet © Artesyn Technologies® 2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
PAGE 1
DC/DC CONVERTERS
|
30W DC
30 Watt
Wide input DC/DC converters
INPUT
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
CURRENT
9-18VDC
5VDC
5.0A
2.8A
75%
±0.2%
±1.0%
WR12S05/5000U
9-18VDC
12VDC
2.5A
3.2A
78%
±0.2%
±1.0%
WR12S12/2500U
9-18VDC
15VDC
2.0A
3.2A
78%
±0.2%
±1.0%
WR12S15/2000U
18-36VDC
5VDC
5.0A
1.35A
77%
±0.2%
±1.0%
WR24S05/5000U
18-36VDC
12VDC
2.5A
1.55A
80%
±0.2%
±1.0%
WR24S12/2500U
18-36VDC
15VDC
2.0A
1.55A
80%
±0.2%
±1.0%
WR24S15/2000U
36-72VDC
5VDC
5.0A
0.68A
77%
±0.2%
±1.0%
WR48S05/5000U
36-72VDC
12VDC
2.5A
0.78A
80%
±0.2%
±1.0%
WR48S12/2500U
36-72VDC
15VDC
2.0A
0.78A
80%
±0.2%
±1.0%
WR48S15/2000U
9-18VDC
±12VDC
±1.25A
3.05A
82%
±0.2%
±1.0%
WR12D12/1250U
9-18VDC
±15VDC
±1.0A
3.05A
82%
±0.2%
±1.0%
WR12D15/1000U
18-36VDC
±12VDC
±1.25A
1.5A
84%
±0.2%
±1.0%
WR24D12/1250U
18-36VDC
±15VDC
±1.0A
1.5A
84%
±0.2%
±1.0%
WR24D15/1000U
36-72VDC
±12VDC
±1.25A
0.73A
86%
±0.2%
±1.0%
WR48D12/1250U
36-72VDC
±15VDC
±1.0A
0.73A
86%
±0.2%
±1.0%
WR48D15/1000U
(1)
INPUT
CURRENT
(2)
TYPICAL
EFFICIENCY
REGULATION
LINE (3)
LOAD
MODEL
NUMBER
(4)
Notes
1
2
3
4
5
6
7
8
Nominal input 12, 24 and 48VDC.
Maximum at full load.
Measured from high line to low line.
Measured from full load to 0.25% full load.
In many cases, the isolation specification may be upgraded. Consult
factory for details.
MTBF figures are based on actual product performance. Consult factory
for details.
Fixed frequency design provides for easier input filtering and better noise
performance.
Standard specifications are conservative and can be optimised for specific
applications. In particular, converter start-up at lower than specified
temperature, wider input voltage range and output voltage adjustment are
all relatively simple modifications to the standard product. Consult factory
for details.
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed
by ±10% using either method shown below.
5
5
TRIM
UP
4
4
10KΩ
TRIMPOT
TRIM
DOWN
3
3
0.800
(20.300)
0.70
(17.80)
0.300
(7.600)
PIN CONNECTIONS
PIN NUMBER
SINGLE OUTPUT
DUAL OUTPUT
1
+ Input
+ Input
2
– Input
– Input
3
+ Sense/Trim Down
+ Output
4
Trim
Common
5
– Sense/Trim Up
– Output
6
+ Output
No Pin
7
– Output
No Pin
8
Remote On/Off Control
0.200
(5.100)
0.040 Dia.
(1.000)
0.400
(10.200)
4.56
(115.80)
7 6
2.50
(63.50)
2
0.30
(7.60)
International Safety Standard Approvals
0.22 Min.
(5.60)
0.83
(21.10)
1
8
0.400
(10.200)
0.600
(15.200)
1.50
(38.10)
DS_WRU_19980401.PDF
UL1950 File Numbers E136005 and E131987
5 4 3
BOTTOM
VIEW
2.56
(66.00)
ALL DIMENSIONS IN INCHES (mm)
http://www.artesyn.com
PAGE 2