ETC CP800

CP800 Series
Single Phase Bridge Rectifiers
Features:
• High surge current capability.
• PCB mounted/screw fixing.
• Surge overload rating: 200 Amperes peak.
• Low forward voltage drop and reverse leakage.
• Small size, simple installation.
• Reliable low cost construction utilizing moulded plastic technique.
Mechanical Data:
Mounting position
: Any.
Terminals
: Leads solderable per MILSTD-202, Method 208.
Mounting
: Through hole for a number 6
screw.
Dimensions : Inches (Millimetres)
Maximum Ratings and Electrical Characteristics
At 25°C ambient temperature unless otherwise noted; resistive or inductive load at 60Hz.
Parameter
CP802
CP806
CP808
Maximum recurrent peak reverse voltage
200
600
800
Maximum bridge input voltage RMS
140
420
560
Maximum average rectified output at
see Figure 2
TC = 50°C
TA = 40°C
Unit
V
8.0
3.0
A
Peak one cycle surge overload current
200
A
Maximum forward voltage drop per element at 4.0A dc and 25°C
see Figure 3
1.1
V
Maximum reverse leakage at rated DC blocking voltage per element at 25°C
See Figure 4
at 100°C
10.0
1.0
µA
mA
I2t Rating for fusing ( t<8.3ms)
166
A2 seconds
Typical junction capacitance per leg (Note 4) CJ
200
pF
Typical thermal resistance per leg (Note 3) RθJA
Typical thermal resistance per leg (Note 2) RθJL
21
6
°C/W
Operating temperature range
-55 to +125
Storage temperature range
-55 to +150
°C
Notes:
1. Bolt down on to a heat-sink with silicon thermal compound between bridge and mounting surface for maximum heat transfer with a
number 6 screw.
2. Units Mounted on a 8.6” x 8.6” x 24” thick (22 x 22 x 0.6cm) Aluminium plate heatsink.
3. Units Mounted on PCB at 0.375” (9.5mm) lead length with 0.5” x 0.5” (12 x 12mm) copper pads.
4. Measured at 1.0MHz and applied reverse voltage.
Page 1
31/05/05 V1.0
CP800 Series
Single Phase Bridge Rectifiers
Output Current Amperes
Forward Surge Current,
Amperes pk (Hale Sine Wave)
Rating and Characteristic Curves
Number of Cycles at 60Hz
Ambient Temperature, °C
Instantaneous Reverse Current, µ A
Instantaneous Forward Current, Amperes
Figure 2 - Derating Curve for Output Rectified
Current
Instantaneous Forward Voltage, Volts
Percent of Rated Peak Reverse Voltage
Figure 3 - Typical Forward Characteristics (25°C)
Figure 4 - Reverse Characteristics
Specifications
VRRM
(V)
Maximum
Input Voltage
(V ac)
200
600
600
420
800
560
IO
(A)
TA
(°C)
IFSM
(A)
Body
Part Number
Height
8
50
Lead
Width/Depth
Length
Spacing
Diameter
12.7
1.3
Typical
CP802
200
7.6
19.1
40
19.1
CP806
CP808
Dimensions : Millimetres
Page 2
31/05/05 V1.0
CP800 Series
Single Phase Bridge Rectifiers
Notes:
International Sales Offices:
AUSTRALIA – Farnell InOne
FINLAND – Farnell InOne
NETHERLANDS – Farnell InOne
SWITZERLAND – Farnell InOne
Tel No:
Tel No:
Tel No:
++ 61 2 9645 8888
Fax No: ++ 61 2 9644 7898
Fax No: ++ 358 9 345 5411
Fax No: ++ 31 30 241 7333
Tel No: ++ 41 1 204 64 64
Fax No: ++ 41 1 204 64 54
AUSTRIA – Farnell InOne
FRANCE – Farnell InOne
NEW ZEALAND – Farnell InOne
UK – Farnell InOne
Tel No:
Tel No:
Tel No:
Tel No:
++ 43 662 2180 680
++ 358 9 560 7780
++ 33 474 68 99 99
++ 31 30 241 7373
++ 64 9 357 0646
++ 44 8701 200 200
Fax No: ++ 43 662 2180 670
Fax No: ++ 33 474 68 99 90
Fax No: ++ 64 9 357 0656
Fax No: ++ 44 8701 200 201
BELGIUM – Farnell InOne
GERMANY – Farnell InOne
NORWAY – Farnell InOne
UK – BuckHickman InOne
Tel No:
Tel No:
Tel No:
++ 45 44 53 66 66
++ 44 8450 510 150
++ 32 3 475 2810
++ 49 89 61 39 39 39
Fax No: ++ 32 3 227 3648
Fax No: ++ 49 89 613 59 01
Fax No: ++ 45 44 53 66 02
++ 44 8450 510 130
BRAZIL – Farnell-Newark InOne
HONG KONG –
Farnell-Newark InOne
Tel No: ++ 852 2268 9888
PORTUGAL – Farnell InOne
UK – CPC
++ 55 11 4066 9400
Tel No:
++ 34 93 475 8804
++ 44 8701 202 530
Fax No: ++ 55 11 4066 9410
Fax No: ++ 852 2268 9899
Fax No: ++ 34 93 474 5288
++ 44 8701 202 531
CHINA – Farnell-Newark InOne
IRELAND – Farnell InOne
SINGAPORE –
Tel No:
Tel No:
Tel No:
++86 10 6238 5152
Fax No: ++86 10 6238 5022
Farnell-Newark InOne
Tel No: ++ 65 6788 0200
++ 353 1 830 9277
Fax No: ++ 353 1 830 9016
Fax No: ++ 65 6788 0300
export
EXPORT – Farnell InOne
Tel No:
++ 44 8701 200 208
Fax No: ++ 44 8701 200 209
For enquiries from all other markets
DENMARK – Farnell InOne
ITALY – Farnell InOne
SPAIN – Farnell InOne
Tel No:
Tel No:
Tel No:
++ 45 44 53 66 44
++ 39 02 93 995 200
++ 34 93 475 8805
Fax No: ++ 45 44 53 66 06
Fax No: ++ 39 02 93 995 300
Fax No: ++ 34 93 474 5107
ESTONIA – Farnell InOne
MALAYSIA –
SWEDEN – Farnell InOne
http://www.farnellinone.com
Tel No:
++ 358 9 560 7780
Fax No: ++ 358 9 345 5411
Farnell-Newark InOne
Tel No: ++ 60 3 7873 8000
Fax No: ++ 60 3 7873 7000
Tel No:
++ 46 8 730 50 00
Fax No: ++ 46 8 83 52 62
http://www.buckhickmaninone.com
http://www.cpc.co.uk
Disclaimer This data sheet and its contents (the "Information") belong to the Premier Farnell Group (the "Group") or are licensed to it. No licence is granted for the use of it other than for information purposes
in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied.
The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data
sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage
resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded.
This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Multicomp is the registered trademark of the Group. © Premier Farnell plc 2004.
Page 3
31/05/05 V1.0