Fiber-Optic Accessories E39 Various Accessories Expand the Usefulness of the Fiber-Optic Cables Lenses extend sensing distances Side-view attachments provide space savings Flexible stainless steel tubes protect plastic fibers from mechanical damage Thin fiber adapters as replacement Splices for 2.2 mm fiber can be used to repair cut fiber Ordering Information ATTACHMENTS Description Part number Focusing lens pair (use with E32-TC50/200/500/1000, E32-T11(L), E32-TC200C, E32-T61) E39-F1 Side-view reflector pair E39-F2 Convergent beam conversion kit (to fit fibers that accept E39-F1 lenses) E39-F3 Pinpoint focusing lens (for E32-D32) E39-F3A Side-view diffuse reflective conversion kit (for through-beam fibers) E39-F5 PROTECTIVE STAINLESS STEEL FLEXIBLE TUBES FOR PLASTIC FIBERS Description Appearance Length (L) Part number 0.5 m E39-F32A5 1m E39-F32A E32-DC200, E32-DC200B(4), E32-CC200, E32-D11 0.5 m E39-F32D5 E32-D11L, E32-D51 1m E39-F32D E32-TC200E, E32-TC200F(4), E32-T21, E32-T12L 0.5 m E39-F32B5 1m E39-F32B E32-TC200, E32-TC200B(4), E32-T11, E32-T11L, 0.5 m E39-F32C5 E32-T51L 1m E39-F32C E32-DC200E, E32-DC200F(4), E32-D21, E32-D21L Single tubes Pairs ADAPTERS/REPAIR PARTS Description Part number Thin fiber adapter (1.0 mm to 2.2 mm dia.) E39-F9 Splice for 2.2 mm dia. fiber (except E32-T51/E32-D51) E39-F10 Fiber cutting tool (supplied with each trimmable plastic fiber optic cable) E39-F4 Fiber probe bending tool E39-F11 Mounting bracket replacement for E32-T16 (order two) E39-L4 E39 E39 Dimensions Unit: mm (inch) ATTACHMENTS E39-F1 Lens kit (pair) E39-F2 Side-view attachment (pair) Note: One set includes two units. Note: One set includes two units. E39-F3 Convergent beam conversion kit M3 toothed washers Two, M3 x 3 Slotted head machine screws Two, 4 dia. 12 6.4 18 3.6 3 Two, 3.2 8.5 +0.2 0 dia. 6.4 8 0.2 6.5 M3 x 6 Angle fixing screw 20.7 E39-F5 Side-view diffuse reflective conversion kit E39-F3A Reflective unit lens (Allen wrench included) PROTECTIVE STAINLESS STEEL TUBES E39-F32A, E39-F32A5 E39-F32B, E39-F32B5 Note: 1. L is as follows: E39-F32A and E39-F32B: 1,000 E39-F32A5, E39-F32B5: 500 2. These are sold as pairs. 2 E39 E39 Unit: mm (inch) E39-F32C, E39-F32C5 Note: 1. L is as follows: E39-F32C: 1,000 E39-F32C5: 500 2. These are sold as single pairs. E39-F32D, E39-F32D5 Note: 1. L is as follows: E39-F32D: 1,000 E39-F32D5: 500 2. These are sold as single tubes. ADAPTERS/REPAIR PARTS E39-F4 Fiber cutter E39-F11 Bending tool E39-F9 Attachment for thin fiber E39-F10 Fiber connector 3 E39 E39 Installation INSTALLING ACCESSORIES E39-F1 Lens Kit This pair of lenses increases the sensing distance of selected fiber-optic cables. To install, screw each lens onto the threaded tip of each sensing head. Amplifer Sensing distance with fiber-optic cables Part number Fiber-optic E32-T11 cable E32-T11L E32-T11R E32-TC50 E32-TC200 E32TC200C E32-TC500 E32TC1000 E32-T61 E3X-A w/ lens 1m (3.3 ft) 1m (3.3 ft) 1m (3.3 ft) 1.5 m (4.9 ft) 1.5 m (4.9 ft) 800 mm (31.5 in) 1.5 m (4.9 ft) 1m (3.3 ft) 1.5 m (4.9 ft) w/o lens 180 mm (7.1 in) 350 mm (13.8 in) 140 mm (5.5 in) 200 mm (7.9 in) 200 mm (7.9 in) 150 mm (5.9 in) 200 mm (7.9 in) 500 mm (19.7 in) 150 mm (5.9 in) w/ lens 4m (13.1 ft) 4m (13.1 ft) 4m (13.1 ft) Contact Omron 4m (13.1 ft) Contact Omron Contact Omron Contact Omron 4m (13.1 ft) w/o lens 850 mm (33.5 in) 1.66 m (5.5 ft) 670 mm (26.4 in) Contact Omron 950 mm (37.4 in) Contact Omron Contact Omron Contact Omron 570 mm (22.4 in) w/ lens 400 mm (15.8 in) 550 mm (21.7 in) Contact Omron — 670 mm (26.4 in) 350 mm (13.8 in) — 1m (3.3 ft) 450 mm (17.7 in) w/o lens 80 mm (3.2 in) 150 mm (5.9 in) Contact Omron — 80 mm (3.1 in) 60 mm (2.4 in) — 500 mm (19.7 in) 60 mm (2.4 in) w/ lens 2m (6.6 ft) 2m (6.6 ft) 2.1 m (6.9 ft) 3m (9.8 ft) 3m (9.8 ft) 1.6 m (5.2 ft) 3m (9.8 ft) 1m (3.3 ft) 3m (9.8 ft) w/o lens 360 mm (14.2 in) 700 mm (27.6 in) 280 mm (11.0 in) 400 mm (15.7 in) 400 mm (15.7 in) 300 mm (11.8 in) 400 mm (15.7 in) 500 mm (19.7 in) 300 mm (11.8 in) w/ lens 2m (6.6 ft) 2m (6.6 ft) 2.1 m (6.9 ft) Contact Omron 3m (9.8 ft) 3.6 m (11.8 ft) Contact Omron Contact Omron 3m (9.8 ft) w/o lens 360 mm (14.2 in) 700 mm (27.6 in) 280 mm (11.0 in) Contact Omron 400 mm (15.7 in) 300 mm (11.8 in) Contact Omron Contact Omron 300 mm (11.8 in) 250 mm (9.8 in) 250 mm (9.8 in) Contact Omron Contact Omron 420 mm (16.5 in) Contact Omron Contact Omron Contact Omron Contact Omron w/o lens 90 mm (3.5 in) 90 mm (3.5 in) Contact Omron Contact Omron 55 mm (2.2 in) Contact Omron Contact Omron Contact Omron Contact Omron w/ lens 1.3 m (4.3 ft) 1.2 m (3.9 ft) 1.3 m (4.3 ft) Contact Omron 2m (6.6 ft) 800 mm (31.5 in) Contact Omron Contact Omron 2m (6.6 ft) w/o lens 240 mm (9.4 in) 500 mm (19.7 in) 180 mm (7.1 in) Contact Omron 270 mm (10.6 in) 200 mm (7.9 in) Contact Omron Contact Omron 180 mm (7.1 in) w/ lens 1.4 m (4.6 ft) 1.28 m (4.2 ft) 1.4 m (4.6 ft) Contact Omron 2.1 m (6.9 ft) 850 mm (33.5 in) Contact Omron Contact Omron 2.1 m (6.9 ft) w/o lens 260 mm (10.2 in) 540 mm (21.3 in) 200 mm (7.9 in) Contact Omron 290 mm (11.4 in) 210 mm (8.3 in) Contact Omron Contact Omron 190 mm (7.5 in) w/ lens 1.4 m (4.6 ft) 1.28 m (4.2 ft) 1.4 m (4.6 ft) Contact Omron 2.1 m (6.9 ft) 850 mm (33.5 in) Contact Omron Contact Omron 2.1 m (6.9 ft) w/o lens 260 mm (10.2 in) 540 mm (21.3 in) 200 mm (7.9 in) Contact Omron 290 mm (11.4 in) 210 mm (8.3 in) Contact Omron Contact Omron 190 mm (7.5 in) 120 mm (4.7 in) 120 mm (4.7 in) Contact Omron Contact Omron 190 mm (7.5 in) 100 mm (3.9 in) Contact Omron Contact Omron 130 mm (5.1 in) w/o lens 10 mm (0.4 in) 40 mm (1.6 in) Contact Omron Contact Omron 28 mm (1.1 in) 18 mm (0.7 in) Contact Omron Contact Omron 18 mm (0.7 in) w/ lens 120 mm (4.7 in) 120 mm (4.7 in) Contact Omron 190 mm (7.5 in) 190 mm (7.5 in) 100 mm (3.9 in) — 1m (3.3 ft) 130 mm (5.1 in) w/o lens 10 mm (0.4 in) 40 mm (1.6 in) Contact Omron 28 mm (1.1 in) 28 mm (1.1 in) 18 mm (0.7 in) — 500 mm (19.7 in) 18 mm (0.7 in) E3X-DA E3X-F E3X-H E3X-NH E3X-NHB w/ lens E3X-NM E3X-NT E3X-NV E3X-NVG w/ lens E3X-VG 4 E39 E39 E39-F2 Side View Attachment These attachments provide 90 angle viewing for through-beam cables. Use then with E32-TC50, E32-TC200 and E32TC200C plastic filament cables and E32T61 glass filament cables. Screw each piece onto the threaded tip of each sensing head. Note: This attachment does not increase sensing distance. E39-F3 Diffuse Reflective Conversion Bracket This bracket converts through-beam fiber cables for diffuse reflective sensing. Use it with E32-TC50, E32-TC200 and E32TC200C plastic filament cables. A set of E39-F1 lenses are supplied with this conversion bracket. To install, first remove the mounting nuts from the fiber-optic sensing heads. Then loosen the two set screws on the bracket. Insert the sensing ends through the bracket, then attach the lenses. Tighten the two set screws to hold the sensing heads in place. Mount the bracket at the detection site, then loosen the large center screw to adjust the angle. When the angle that produces reliable detection has been found, tighten the screw to retain that angle. E39-F3A Reflective Unit Lens (for E32-D32 Fiber) When E39-F3A is attached to an E32-D32 fiber, adjust the focal point so that the amplifier will not detect its own light reflected from inside the E39-F3A. E39-F3A so that the light spot is as small as possible. Then fasten the sensing head using the Allen head wrench supplied with the E39-F3A. Place the object to be detected or while paper at the sensing distance, then adjust the insertion depth of the fiber into the In the example shown, A = The focus is farther than the E39-F3A B = The focus is closer than the E39-F3A. E39-F5 Diffuse Reflective Side View Conversion Block This reflective side view block may be used with E32-TC200A plastic filament fiber-optic cable only. It provides a 2 cm (0.79 in) sensing distance. To install, first remove mounting nuts and washers from fiber-optic sensing head. Then, screw the threaded heads as far as they will go onto the mounting holes on the narrow side of the block. 5 E39 E39 Protective Stainless Steel Tubes Insert the fiber into the protective armor tube from the head connector side (threaded) of the tube. Push the fiber into the armor tube. The tube should be straight so that the fiber is not twisted when inserted. Then turn the end cap of the tube. Secure the tube on a suitable place with the attached nut. position other than at the end cap, apply tape to the tube so that the portion becomes thicker in diameter Use the attached saddle to secure the end cap of the tube. To secure the tube at a Chemical Resistance Do NOT use a fiber-optic cable and amplifier in an atmosphere containing organic solvents such as paint thinner vapors. NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. CEDSAX3 6 10/99 Specifications subject to change without notice. Printed in the U.S.A.