New Product Digital Fiber Sensors E3X-DA-S An Extensive of Standard Functions to Support the World's Highest Level of Stable Detection. • "GIGA RAY" Giga Power Lighting Element to create a wide variety of value. • Power turning to easily set the optimum light level. • Active Thereshold Control (ATC) reduces incorrect operation due to dust, oil, or other influences. • Automatic Power Control (APC) is always enabled to stabilize emitter power with high accuracy. Ordering Information Amplifier Units [Dimensions➜page 23] Type Appearance Pre-wired (2 m) Applicable wire-saving connector (sold separately) Model Connecting method NPN output E3X-DA21-S 2M PNP output E3X-DA51-S 2M Standard models Wire-saving connector ✽ Pre-wired (2 m) E3X-DA7-S E3X-DA21R-S 2M Pre-wired (2 m) E3X-DA7R-S E3X-DA21F-S 2M E3X-DA51R-S 2M E3X-DA7F-S --- --- Master connector E3X-CN21 Slave connector E3X-CN22 --- --- Master connector E3X-CN21 Slave connector E3X-CN22 E3X-DA9R-S E3X-DA51F-S 2M High-speed response models Wire-saving connector ✽ Model E3X-DA9-S Ultra-long-term APC models Wire-saving connector ✽ Type --- --- Master connector E3X-CN11 Slave connector E3X-CN12 E3X-DA9F-S ✽ An Wire-saving connector sold separately is required. 1 E3X-DA-S Wire-saving connector (sold separately) Type Appearance Protection stickers attached [Dimensions➜page 25] Cable length No. of conductors Model Master connector 4 E3X-CN21 Slave connector 2 E3X-CN22 Master connector 3 E3X-CN11 Slave connector 1 E3X-CN12 2m Note: The E3X-CN11/12 can also be used to connect to the E3X-DA@-S (@: 7/9) or the E3X-DA@R-S (@: 7/9), but the output lines will support only 1 channel. Output function for channel 2 or APC alarm output function will be disabled. Accessories (sold separately) Mounting Brackets [Dimensions➜page 26] Appearance End Plate [Dimensions➜page 26] Model Quantity E39-L143 1 Appearance Model Quantity PFP-M 1 Product Overview }: Strong point of the model Types Connecting method Models Item Input/output Performance External input Output 2 Pre-wired Wire-saving connector E3X-DA21-S E3X-DA51-S E3X-DA7-S E3X-DA9-S 1 input --- Ultra-long-term APC models ---: Not provided High-speed response models Pre-wired Wire-saving connector Pre-wired Wire-saving connector E3X-DA21R-S E3X-DA51R-S E3X-DA7R-S E3X-DA9R-S E3X-DA21F-S E3X-DA51F-S E3X-DA7F-S E3X-DA9F-S 1 input --- --- 2 outputs 1 output and 1 APC alarm output 1 output Sensing distance with E32-T11R 280 to 2,000 mm (Depends on response time) 140 to 1,000 mm (Depends on response time) 280 mm (Only Super-high-speed Mode) Sensing distance with E32-D11R 100 to 840 mm (Depends on response time) 50 to 420 mm (Depends on response time) 100 mm (Only Super-high-speed Mode) Giga Power (GIGA RAY) } (Margin: × 160) { { High-speed response { (80 μs) { (80 μs) } (46 μs) { { { Automatic power control (APC) { } (Ultra-long-term APC) { Timer { { { ATC { { { Key lock { { { Easy key lock (switchable) --- { { APC margin display --- { --- Slow-motion display --- --- { Power tuning Function Standard models {: Provided E3X-DA-S Ratings and Specifications Amplifier Units Item Type Standard models Ultra-long-term APC models High-speed response models Model E3X-DA@-S (@: 21/51/7/9) E3X-DA@R-S (@: 21/51/7/9) E3X-DA@F-S (@: 21/51/7/9) Light source (wavelength) Red,4-element LED (625 nm) Power supply voltage 12 to 24 VDC ±10%, ripple (p-p) 10% max. Power consumption Normal mode : 960 mW max. (Current consumption: 40 mA max. at 24 VDC, 80 mA max. at 12 VDC) Power saving ECO1: 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC) Power saving ECO2: 600 mW max. (Current consumption: 25 mA max. at 24 VDC, 50 mA max. at 12 VDC) Control output / APC alarm output Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector; load current: 50 mA max.; residual voltage: 2 V max. External input ✽1 No-voltage input (contact / transistor) ✽2 Protection circuits Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection Super-highspeed Mode ✽3 High-speed ReMode sponse Standard Mode time High-resolution Mode Tough Mode Sensitivity setting --NPN output: Operate: 46 μs, Reset: 48 μs PNP output: Operate: 51 μs, Reset: 53 μs Operate or reset: 80 μs Operate or reset: 250 μs Operate or reset: 1 ms --- Operate or reset: 4 ms Operate or reset: 16 ms Teaching or manual method Power tuning Light emission power and reception gain, digital control method Differential detection Switchable between Single-edge and Double-edge Detection Modes. Single edge: Set to 250 μs, 500 μs, 1 ms, 10 ms, or 100 ms. Double edge: Set to 500 μs, 1 ms, 2 ms, 20 ms, or 200 ms Automatic power control (APC) Always enabled. High-speed control of emission current Wide-range APC for the E3X-DA@R-S --- Select from timer disabled, OFF-delay, ON-delay, One-shot, or ON-delay + OFF-delay timer Functions Timer 1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1-s increments) ATC Provided APC margin display --- Slow-motion display --- Zero reset Negative values can be displayed. (Threshold value is shifted.) Resetting settings Select from initial reset (factory defaults) or user reset (saved settings). Mutual interference prevention Possible for up to 10 units ✽4 ECO Mode ✽5 Select from OFF (digital display lit), ECO1 (digital display dimmed), and ECO2 (digital display OFF). External input setting ✽1 Select from teaching operations, power tuning, zero reset, emitter OFF, or ATC start. Output setting Select from output for each channel, area output, or self-diagnosis. Operation indicator for channel 1(orange) Operation indicator for channel 2(orange) ✽1. Only for Pre-wired models. ✽2. The following details apply to inputs. Indicator Contact input (relay or switch) Provided --Provided --- --- --Operation indicator for channel 1(orange) APC alarm output indicator (orange) Operation indicator for channel 1(orange) Power tuning indicator (orange) Non-contact input (transistor) NPN ON: Shorted to 0 V (sourcing current: 1 mA max.). OFF: Open or shorted to Vcc. ON: 1.5 V max. (sourcing current: 1 mA max.) OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.) PNP ON: Shorted to Vcc (sinking current: 3 mA max.). OFF: Open or shorted to 0 V. ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.) OFF: 1.5 V max. (leakage current: 0.1 mA max.) ✽3. The communications function and mutual interference prevention function are disabled if detection is set to Super-high-speed mode. ✽4. Mutual interference prevention is enabled if Amplifier Units are connected together. It is also enabled in the same way if E3X-DA-S-series Units and E3C-LDA-series Units are used together. If power tuning is enabled, mutual interference prevention can be used for up to six units. ✽5. For the E3X-DA@-S (@: 21/51/7/9), the rated sensing distance is approximately 1/2 and the incident level is approximately 1/3 of the normal levels when ECO mode is enabled. 3 E3X-DA-S Item Model E3X-DA@-S (@: 21/51/7/9) E3X-DA@R-S (@: 21/51/7/9) E3X-DA@F-S (@: 21/51/7/9) Digital display Select from incident level + threshold or other 6 patterns (Refer to 6. Display switch on page 17.) Display orientation Switching between normal / reversed display is possible. Key lock Key lock Ambient illumination (Receiver side) Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. Maximum connectable Units 16 (The ambient temperature specification depends on the number of connected units.) Key lock / Easy key lock. Ambient temperature range Operating: Groups of 1 to 2 Amplifiers: −25 to 55°C Groups of 3 to 10 Amplifiers: −25 to 50°C Groups of 11 to 16 Amplifiers: −25 to 45°C Ambient humidity range Operating and storage: 35% to 85% (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute Vibration resistance Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y and Z directions Degree of protection IEC 60529 IP50 (with Protective Cover attached) Connection method Pre-wired (standard length 2 m) or Wire-saving connector Storage: −30 to 70°C (with no icing or condensation) Weight (packed state) Materials Pre-wired models: Approx. 100 g, Wire-saving connector models: Approx. 55 g Case Polybutylene terephthalate (PBT) Cover Polycarbonate (PC) Accessories Instruction Manual Wire-saving connectors Item Model E3X-CN12 2.5 A Rated voltage 50 V Contact resistance 20 mΩ max. (20 mVDC max., 100 mA max.) (The figure is for connection to the Amplifier Unit and the adjacent connector. It does not include the conductor resistance of the cable.) No. of insertions Destruction: 50 times (The figure for the number of insertions is for connection to the Amplifier Unit and the adjacent connector.) Materials Housing Polybutylene terephthalate (PBT) Contacts Phosphor bronze / gold-plated nickel Weight (packed state) 4 E3X-CN21/22/11 Rated current Approx. 55 g Approx. 25 g E3X-DA-S Sensing Distance E3X-DA@-S (@: 21/51/7/9) E3X-DA@F-S(@: 21/51/7/9) Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S. Fiber Unit Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Screw-shaped model Sensing method Size M3 Throughbeam models M4 Sensing distance (unit: mm) Sensing direction Model High-resolution mode Standard mode High-speed mode Super-highspeed mode Straight E32-T21R 2M 450 300 250 150 60 Right angle E32-T11N 2M 2,000 1,400 1,000 700 280 E32-T11R 2M 2,000 1,400 1,000 700 280 E32-TC200 2M 2,800 2,000 1,550 1,000 400 4,000 ✽ 3,400 2,700 1,740 700 Straight E32-T11L 2M Right angle M3 Straight M4 Reflective models Tough mode Right angle E32-C31N 2M 110 80 50 46 14 E32-D21R 2M 140 100 60 40 16 E32-C31 2M 330 240 150 100 44 E32-D211R 2M 140 100 60 40 16 E32-D11N 2M 840 600 350 240 100 E32-C11N 2M 780 560 350 320 100 E32-D11R 2M M6 Straight E32-DC200 2M 840 600 350 240 100 1,400 1,000 600 400 180 E32-CC200 2M 1,400 1,000 600 400 180 E32-D11L 2M 1,820 1,300 800 520 220 High-speed mode Super-highspeed mode 280 ✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Fiber Unit Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Flat model Sensing method Sensing distance (unit: mm) Sensing direction Top view Throughbeam models Side view Flat view Top view Reflective models Side view Flat view Size Model Tough mode High-resolution mode Standard E32-T15XR 2M 2,000 1,400 1,000 700 Small E32-T25XR 2M 450 300 250 150 60 Standard E32-T15YR 2M 750 550 450 260 100 Small E32-T25YR 2M 170 120 100 50 20 Standard E32-T15ZR 2M 750 550 450 260 100 Small E32-T25ZR 2M 170 120 100 50 20 Standard E32-D15XR 2M 840 600 350 240 100 Small E32-D25XR 2M 140 100 60 40 16 Standard E32-D15YR 2M 200 140 100 52 24 Small E32-D25YR 2M 40 28 16 10 4 Standard E32-D15ZR 2M 200 140 100 52 24 Small E32-D25ZR 2M 40 28 16 10 4 High-speed mode Super-highspeed mode Fiber Unit Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Cylindrical model Sensing method Sensing direction Throughbeam models Top view Side view Sensing distance (unit: mm) Size Top view E32-T223R 2M φ3 E32-T12R 2M Tough mode 450 300 250 150 60 2,000 1,400 1,000 700 280 E32-T24R 2M 170 120 100 50 20 E32-T14LR 2M 750 550 450 260 100 φ2 E32-D22B 2M 140 100 60 40 16 E32-D32 2M 330 240 150 100 44 E32-D22R 2M 140 100 60 40 16 E32-D32L 2M 700 500 300 200 90 φ2 E32-D24R 2M 70 52 30 20 8 φ6 E32-D14LR 2M 220 160 100 60 28 High-speed mode Super-highspeed mode Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Model equipped with sleeve Sleeve size φ0.25 × 5 Throughbeam models Reflective models φ0.5 × 40 Standard mode φ3 Fiber Unit Sensing method High-resolution mode φ1 φ3 Side view Model φ1 φ1.5 Reflective models Standard mode Sensing distance (unit: mm) Mounting size φ3 Model E32-T333-S5 1M E32-T33 1M φ0.9 × 40 M3 E32-TC200F4R 2M φ1.2 × 90 M4 E32-TC200BR 2M Tough mode High-resolution mode Standard mode 35 25 20 12 8 150 110 90 50 20 450 300 250 150 60 2,000 1,400 1,000 700 280 φ0.5 × 15 φ2 E32-D331 2M 14 10 6 4 2 φ0.8 × 15 φ3 E32-D33 2M 70 50 30 20 8 φ1.2 × 40 M3 E32-DC200F4R 2M 140 100 60 40 16 φ2.5 × 90 M6 E32-DC200BR 2M 840 600 350 240 100 For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 5 E3X-DA-S E3X-DA@-S (@: 21/51/7/9) E3X-DA@F-S(@: 21/51/7/9) Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S. Fiber Unit Movable section (Flexibility) Sensing Type method Screw-shaped model Throughbeam models Cylindrical model Flat model Screw-shaped model Reflective models Cylindrical model Flat model Fiber Unit Heat-resistance model Sensing Operating method temperature 100°C Throughbeam models 150°C Amplifier Unit Size M3 M4 φ1.5 φ3 Standard Small M3 M4 M6 φ1.5 φ3 Standard Small Lens --Lens High-power lens --Lens High-power lens --- 350°C Reflective models E32-T21 2M E32-T11 2M E32-T22B 2M E32-T12B 2M E32-T15XB 2M E32-T25XB 2M E32-D21 2M E32-D21B 2M E32-D11 2M E32-D22B 2M E32-D221B 2M E32-D15XB 2M E32-D25XB 2M Tough mode 680 2,500 680 2,500 2,500 500 140 300 840 140 300 840 240 Amplifier Unit 200°C 100°C 150°C 200°C 350°C 400°C Model Lens --High-power lens --- Model E32-T51R 2M E32-T51R 2M + E39-F1 E32-T51R 2M + E39-F16 E32-T51 2M E32-T51 2M + E39-F1-33 E32-T51 2M + E39-F16 E32-T54 2M E32-T81R-S 2M E32-T61-S 2M E32-T61-S 2M + E39-F1 E32-T61-S 2M E32-T61-S 2M + E39-F16 E32-D51R 2M E32-D51 2M E32-D81R 2M E32-D61 2M E32-D73 2M Tough mode 1,600 4,000 ✽ 4,000 ✽ 2,800 4,000 ✽ 4,000 ✽ 840 1,000 1,680 4,000 ✽ 1,680 4,000 ✽ 670 1,120 420 420 280 E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highmode mode mode speed mode 480 400 220 90 1,800 1,350 900 360 480 400 220 90 1,800 1,350 900 360 1,800 1,350 900 360 360 300 170 70 100 60 40 16 220 140 90 40 600 350 240 100 100 60 40 16 220 140 90 40 600 350 240 100 170 100 60 30 E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highmode mode mode speed mode 1,100 800 560 225 4,000 ✽ 4,000 ✽ 3,900 1,500 4,000 ✽ 4,000 ✽ 4,000 ✽ 4,000 ✽ 2,000 1,500 1,000 400 4,000 ✽ 4,000 ✽ 2,300 1,400 4,000 ✽ 4,000 ✽ 4,000 ✽ 4,000 ✽ 600 450 300 120 720 550 360 140 1,200 900 600 240 4,000 ✽ 4,000 ✽ 4,000 ✽ 1,800 1,200 900 600 240 4,000 ✽ 4,000 ✽ 4,000 ✽ 3,100 480 280 190 80 800 450 320 144 300 180 120 54 300 180 120 54 200 120 80 36 ✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Fiber Unit Chemical-resistance / Oil-resistance model Sensing Type method φ5 φ7.2 φ5 Heat-resistance model Throughφ5 beam Side view models M4 Chemical-resistance cable M4 Right angle Chemical-resistance cable φ6 φ7 Reflective Side view models M6 Chemical-resistance cable Amplifier Unit Model E32-T12F 2M E32-T11F 2M E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highTough mode mode mode mode speed mode 4,000 ✽1 4,000 ✽1 4,000 ✽1 1,600 4,000 ✽1 4,000 ✽1 4,000 ✽1 4,000 ✽1 2,600 1,000 E32-T51F 2M 4,000 ✽1 3,600 2,800 1,800 700 E32-T14F 2M 1,400 1,000 800 500 200 E32-T11U 2M 2,500 1,800 1,350 900 360 E32-T11NU 2M 1,440 1,040 800 520 200 E32-D12F 2M --- ✽2 320 190 130 60 E32-D14F 2M --- ✽2 140 80 60 20 E32-D11U 2M 840 600 350 240 100 ✽1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. ✽2. Even if there is no sensing object, the sensor will detect light that is reflected by the fluororesin. Fiber Unit Vacuum-resistance model Sensing Operating ambient method temperature Throughbeam models 120°C 200°C Amplifier Unit Sensing direction Top view Right angle Model E32-T51V 1M E32-T51V 1M + E39-F1V E32-T54V 1M E32-T84SV 1M Tough mode 720 3,780 580 1,760 E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highmode mode mode speed mode 520 400 260 100 2,700 2,000 1,360 520 420 250 200 70 1,250 950 640 260 For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 6 E3X-DA-S E3X-DA@-S (@: 21/51/7/9) E3X-DA@F-S(@: 21/51/7/9) Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S. Fiber Unit Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Long distance / Dust resistance (High-power), Detection through gaps (Narrow vision field) Sensing method Type High-power (integrated unit) Throughbeam models High-power (with lens unit) Sensing direction / Lens type Model Tough mode High-resolution mode Standard mode High-speed mode Super-highspeed mode Top view E32-T17L 10M 20,000 ✽1 20,000 ✽1 20,000 ✽1 20,000 ✽1 8,000 Side view E32-T14 2M 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 1,800 High-power E32-T11N 2M + E39-F1 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 2,000 Ultrahigh-power E32-T11N 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 3,600 High-power E32-T11R 2M + E39-F1 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 2,000 Ultrahigh-power E32-T11R 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 3,600 Side view E32-T11R 2M + E39-F2 1,450 1,040 800 500 200 High-power E32-TC200 2M + E39-F1 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 3,000 Ultrahigh-power E32-TC200 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 Side view E32-TC200 2M + E39-F2 2,350 1,680 1,400 900 320 High-power E32-T11 2M + E39-F1 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 1,860 Ultrahigh-power E32-T11 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 Side view E32-T11 2M + E39-F2 2,300 1,640 1,320 860 320 High-power E32-T11U 2M + E39-F1 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 1,860 Ultrahigh-power E32-T11U 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 Side view Reflective models Sensing distance (unit: mm) 2,300 1,640 1,320 860 320 High-power E32-T11NU 2M + E39-F1 E32-T11U 2M + E39-F2 4,000 ✽2 4,000 ✽2 4,000 ✽2 2,600 1,000 Ultrahigh-power E32-T11NU 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 2,800 High-power E32-T81R-S 2M + E39-F1 4,000 ✽2 4,000 ✽2 4,000 ✽2 2,700 1,000 Ultrahigh-power E32-T81R-S 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 1,800 Side view E32-T81R-S 2M + E39-F2 1,000 720 550 360 140 High-power E32-T61-S 2M + E39-F1 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 1,800 Ultrahigh-power E32-T61-S 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 3,100 Side view E32-T61-S 2M + E39-F2 1,680 1,200 900 600 240 4,000 ✽2 3,800 2,500 1,000 Narrow vision field (aperture angle: 4°) Top view E32-T22S 2M 4,000 ✽2 Side view E32-T24S 2M 4,000 ✽2 3,500 2,600 1,740 700 High-power Top view E32-D16 2M 40 to 2,800 40 to 2,000 40 to 1,400 40 to 900 40 to 480 ✽1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm. ✽2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Fiber Unit Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Minute object detection (Small-spot model) Sensing method Reflective models Sensing distance (unit: mm) Spot diameter (mm) Focal length (mm) φ0.1 to 0.6 (Variable) 6 to 15 E32-C42 1M + E39-F3A Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm φ0.3 to 1.6 (Variable) 10 to 30 E32-C42 1M + E39-F17 Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm Model Tough mode Reflective models High-speed mode φ0.1 E32-C42S 1M 7 E32-C41 1M + E39-F3A-5 Spot diameter of 0.1 mm at 7 mm φ0.2 17 E32-C41 1M + E39-F3B Spot diameter of 0.2 mm at 17 mm 7 E32-C31 2M + E39-F3A-5 Spot diameter of 0.5 mm at 7 mm 17 E32-C31 2M + E39-F3B Spot diameter of 0.5 mm at 17 mm φ6 50 E32-L15 2M φ4 Parallel light 0 to 20 φ3 50 φ0.5 Spot diameter of 6 mm at 50 mm Sensing distance in all mode (40 to 100 mm) E32-C31 2M + E39-F3C Spot diameter of 4 mm max. at 0 to 20 mm E32-C11N 2M + E39-F18 Spot diameter of 3 mm at 50 mm E32-CC200 2M + E39-F18 Spot diameter of 3 mm at 50 mm Amplifier Unit Area range 11 mm E3X-DA@-S (@: 21/51/7/9) Sensing distance (unit: mm) Sensing direction Model Tough mode High-resolution mode Standard mode High-speed mode Super-highspeed mode 440 Side view E32-T16PR 2M 3,100 2,200 1,700 1,120 Flat view E32-T16JR 2M 2,750 2,000 1,500 960 380 4,000 ✽ 3,400 2,600 1,700 680 700 500 300 200 90 30 mm 11 mm Super-highspeed mode Spot diameter of 0.1 mm at 5 mm Area-sensing (Area beam) Throughbeam models Standard mode 5 Fiber Unit Sensing method High-resolution mode E32-T16WR 2M Side view E32-D36P1 2M ✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 7 E3X-DA-S E3X-DA@-S (@: 21/51/7/9) E3X-DA@F-S(@: 21/51/7/9) Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S. Fiber Unit Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Detection without background interference (Convergent-reflective) Sensing method Sensing direction Size Flat view Reflective models Top view Tough mode High-resolution mode Standard mode High-speed mode Standard E32-L16-N 2M ✽ Small E32-L24S 2M ✽ 0 to 4 E32-L25L 2M ✽ 5.4 to 9 (center 7.2) E32-L24L 2M ✽ 2 to 6 (center 4) --- Flat view Model Sensing distance (unit: mm) Super-highspeed mode 0 to 15 0 to 12 ✽ If operation is affected by the background, perform power tuning or set operation to ECO mode to reduce the amount of light that is received. Fiber Unit Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Detection of transparent objects (Retro-reflective) Sensing method Retroreflective models Type Sensing distance (unit: mm) Model Tough mode Square E32-R16 5M + E39-R1 (attached) ✽1 Small E32-R21 2M + E39-R3 (attached) ✽1 Film detection ✽2 High-resolution mode Standard mode High-speed mode Super-highspeed mode 150 to 1,500 10 to 250 E32-C31 2M + E39-F3R+E39-RP37 ✽1 250 200 E32-C31 2M + E39-F3R+E39-RSP1 ✽1 450 300 --100 ✽1. When using a highly reflective object, light reflected from the object may affect the sensor. ✽2. The effect may be small due to the film. Also, stable detection may not be possible when there is a sensing object directly in front of the Lens Unit. Be sure to check operation in advance. Fiber Unit Amplifier Unit E3X-DA@-S (@: 21/51/7/9) FPD / Semiconductor / Solar battery industry Sensing method Application Operating temperature Throughbeam models Wafer mapping High-resolution mode Standard mode High-speed mode Super-highspeed mode 0 to 15 0 to 12 0 to 15 0 to 12 E32-A08 2M ✽ 10 to 20 --- 300°C E32-A08H2 3M ✽ 10 to 20 --- 70°C E32-A09 2M 15 to 38 --- 150°C E32-A09H 2M 15 to 38 --- 300°C E32-A09H2 2M 20 to 30 --- 60°C E32-L11FP 5M 8 to 20 mm from end of lens (recommended: 11 mm) 70°C E32-L12FS 5M 8 to 20 mm from end of lens (recommended: 11 mm) 85°C E32-L11FS 5M Glass substrate alignment WET process Tough mode E32-L16-N 2M ✽ 70°C Glass substrate mapping Model E32-L16-N 2M ✽ Glass detection Reflective models Sensing distance (unit: mm) 70°C 8 to 20 mm from end of lens (recommended: 11 mm) E32-A03 2M 3,220 2,300 1,780 1,200 500 E32-A03-1 2M 3,220 2,300 1,780 1,200 500 E32-A04 2M 1,280 920 680 450 200 E32-A04-1 2M 1,280 920 680 450 200 ✽ If operation is affected by the background, perform power tuning or set operation to ECO mode to reduce the amount of light that is received. Fiber Unit Amplifier Unit E3X-DA@-S (@: 21/51/7/9) Liquid-level detection model Sensing method Sensing direction Sensing distance (unit: mm) Pipe diameter No limit Reflective Mounted to pipe models Wet φ8 to 10 mm --- Model E32-D36T 5M ✽1, ✽2 E32-L25T 2M Tough mode High-resolution mode Standard mode High-speed mode Super-highspeed mode Applicable pipe: Transparent (no restriction on diameter) Applicable pipe: Transparent pipe with diameter of 8 to 10 mm, recommended pipe wall thickness: 1 mm E32-D82F1 4M ✽1 Wet model ✽1. If a high level of light is received, perform power tuning or set operation to ECO mode to reduce the amount of light that is received. ✽2. In Tough mode, detection may not be possible depending on the pipe diameter. Check operation with the pipe that will be used. For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 8 E3X-DA-S E3X-DA@R-S (@: 21/51/7/9) Fiber Unit Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Screw-shaped model Sensing method Size M3 Throughbeam models M4 Sensing distance (unit: mm) Sensing direction Tough mode High-resolution mode E32-T21R 2M 220 160 130 75 30 1,000 700 500 350 140 E32-T11R 2M 1,000 700 530 350 140 E32-TC200 2M 1,400 1,000 760 500 200 E32-T11L 2M 2,000 1,700 1,350 870 350 E32-C31N 2M 55 40 25 23 7 E32-D21R 2M 70 50 30 20 8 22 Straight Straight Right angle M6 Straight 165 120 75 50 E32-D211R 2M E32-C31 2M 70 50 30 20 8 E32-D11N 2M 420 300 175 120 50 E32-C11N 2M 390 280 175 160 50 E32-D11R 2M 420 300 170 120 50 E32-DC200 2M 700 500 300 200 90 E32-CC200 2M 700 500 300 200 90 E32-D11L 2M 910 650 400 260 110 High-speed mode Super-highspeed mode 140 Fiber Unit Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Flat model Sensing distance (unit: mm) Sensing direction Top view Side view Flat view Top view Reflective models Side view Flat view Size Model Tough mode E32-T15XR 2M 1,000 700 530 350 E32-T25XR 2M 220 160 130 75 30 Standard E32-T15YR 2M 370 270 210 130 50 Small E32-T25YR 2M 85 60 50 25 10 Standard E32-T15ZR 2M 370 270 210 130 50 Small E32-T25ZR 2M 85 60 50 25 10 Standard E32-D15XR 2M 420 300 170 120 50 Small E32-D25XR 2M 70 50 30 20 8 Standard E32-D15YR 2M 100 70 40 26 12 Small E32-D25YR 2M 20 14 8 5 2 Standard E32-D15ZR 2M 100 70 40 26 12 Small E32-D25ZR 2M 20 14 8 5 2 High-speed mode Super-highspeed mode Amplifier Unit Sensing direction Throughbeam models Top view Side view Top view Reflective models E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) Size Model φ1 E32-T223R 2M φ3 E32-T12R 2M Tough mode High-resolution mode 220 160 130 75 30 1,000 700 530 350 140 E32-T24R 2M 85 60 50 25 10 φ3 E32-T14LR 2M 370 270 210 130 50 φ1.5 E32-D22B 2M φ2 E32-D32 2M 70 50 30 20 8 160 120 75 50 22 E32-D22R 2M 70 50 30 20 8 E32-D32L 2M 350 250 150 100 45 φ2 E32-D24R 2M 35 26 15 10 4 φ6 E32-D14LR 2M 110 80 45 30 14 High-speed mode Super-highspeed mode Fiber Unit Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Model equipped with sleeve Sleeve size φ0.25 × 5 Throughbeam models Reflective models φ0.5 × 40 Standard mode φ1 φ3 Side view Standard mode Small Cylindrical model Sensing method High-resolution mode Standard Fiber Unit Sensing method Super-highspeed mode E32-T11N 2M M4 Throughbeam models High-speed mode Straight M3 Sensing method Standard mode Right angle Right angle Reflective models Model Sensing distance (unit: mm) Mounting size φ3 Model Tough mode High-resolution mode Standard mode E32-T333-S5 1M 17 12 10 6 4 E32-T33 1M 75 55 45 25 10 220 160 130 75 30 1,000 700 530 350 140 φ0.9 × 40 M3 E32-TC200F4R 2M φ1.2 × 90 M4 E32-TC200BR 2M φ0.5 × 15 φ2 E32-D331 2M 7 5 3 2 0.8 φ0.8 × 15 φ3 E32-D33 2M 35 25 16 10 4 φ1.2 × 40 M3 E32-DC200F4R 2M 70 50 30 20 8 φ2.5 × 90 M6 E32-DC200BR 2M 420 300 170 120 50 For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 9 E3X-DA-S E3X-DA@R-S (@: 21/51/7/9) Fiber Unit Movable section (Flexibility) Sensing Type method Screw-shaped model Throughbeam models Cylindrical model Flat model Screw-shaped model Reflective models Cylindrical model Flat model Fiber Unit Heat-resistance model Sensing Operating method temperature 100°C Throughbeam models 150°C Amplifier Unit Size M3 M4 φ1.5 φ3 Standard Small M3 M4 M6 φ1.5 φ3 Standard Small Lens --Lens High-power lens --Lens High-power lens --- Reflective models 100°C 150°C 200°C 350°C 400°C E32-T21 2M E32-T11 2M E32-T22B 2M E32-T12B 2M E32-T15XB 2M E32-T25XB 2M E32-D21 2M E32-D21B 2M E32-D11 2M E32-D22B 2M E32-D221B 2M E32-D15XB 2M E32-D25XB 2M Tough mode 340 1,250 340 1,250 1,250 250 70 150 420 70 150 420 120 Amplifier Unit 200°C 350°C Model Lens --High-power lens --- Model E32-T51R 2M E32-T51R 2M + E39-F1 E32-T51R 2M + E39-F16 E32-T51 2M E32-T51 2M + E39-F1-33 E32-T51 2M + E39-F16 E32-T54 2M E32-T81R-S 2M E32-T61-S 2M E32-T61-S 2M + E39-F1 E32-T61-S 2M E32-T61-S 2M + E39-F16 E32-D51R 2M E32-D51 2M E32-D81R 2M E32-D61 2M E32-D73 2M Tough mode 800 4,000 ✽ 4,000 ✽ 1,400 4,000 ✽ 4,000 ✽ 420 500 840 4,000 ✽ 840 4,000 ✽ 330 560 210 210 140 E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highmode mode mode speed mode 240 200 110 45 900 680 450 180 240 200 110 45 900 680 450 180 900 680 450 180 180 150 85 35 50 30 20 8 110 70 45 20 300 170 120 50 50 30 20 8 110 70 45 20 300 170 120 50 85 50 30 15 E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highmode mode mode speed mode 560 425 280 110 3,900 2,900 1,900 760 4,000 ✽ 4,000 ✽ 3,600 1,400 1,000 760 500 200 3,400 2,660 1,150 700 4,000 ✽ 4,000 ✽ 4,000 ✽ 2,600 300 230 150 60 360 280 180 70 600 450 300 120 4,000 ✽ 3,400 2,200 900 600 450 300 120 4,000 ✽ 4,000 ✽ 3,900 1,500 240 135 95 40 400 230 160 72 150 90 60 27 150 90 60 27 100 60 40 18 ✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Fiber Unit Chemical-resistance / Oil-resistance model Sensing Type method φ5 φ7.2 φ5 Heat-resistance model Throughφ5 beam Side view models M4 Chemical-resistance cable M4 Right angle Chemical-resistance cable φ6 φ7 Reflective Side view models M6 Chemical-resistance cable Amplifier Unit Model E32-T12F 2M E32-T11F 2M E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highTough mode mode mode mode speed mode 4,000 ✽1 3,000 2,000 800 4,000 ✽1 3,500 2,500 2,000 1,300 520 E32-T51F 2M 2,500 1,800 1,400 900 350 E32-T14F 2M 700 500 400 250 100 E32-T11U 2M 1,250 900 680 450 180 E32-T11NU 2M 720 520 400 260 100 E32-D12F 2M --- ✽2 160 95 65 30 E32-D14F 2M ✽2 70 40 30 10 420 300 170 120 50 --- E32-D11U 2M ✽1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. ✽2. The sensor will detect light even if there is no sensing object, and so Tough Mode cannot be used. Fiber Unit Vacuum-resistance model Sensing Operating ambient method temperature Throughbeam models 120°C 200°C Amplifier Unit Sensing direction Top view Right angle Model E32-T51V 1M E32-T51V 1M + E39-F1V E32-T54V 1M E32-T84SV 1M Tough mode 360 1,890 290 880 E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) High-resolution Standard High-speed Super-highmode mode mode speed mode 260 200 130 50 1,350 1,000 680 260 210 130 100 35 630 480 320 130 For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 10 E3X-DA-S E3X-DA@R-S (@: 21/51/7/9) Fiber Unit Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Long distance / Dust resistance (High-power), Detection through gaps (Narrow vision field) Sensing method Type High-power (integrated unit) Throughbeam models Reflective models High-power (with lens unit) Sensing distance (unit: mm) Sensing direction / Lens type Model Tough mode High-resolution mode Standard mode High-speed mode Super-highspeed mode Top view E32-T17L 10M 20,000 ✽1 20,000 ✽1 20,000 ✽1 10,000 4,000 Side view E32-T14 2M 4,000 ✽2 4,000 ✽2 3,400 2,250 900 High-power E32-T11N 2M + E39-F1 4,000 ✽2 4,000 ✽2 3,700 2,400 970 Ultrahigh-power E32-T11N 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 1,800 High-power E32-T11R 2M + E39-F1 4,000 ✽2 4,000 ✽2 3,700 2,400 970 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 1,800 Ultrahigh-power E32-T11R 2M + E39-F16 4,000 Side view E32-T11R 2M + E39-F2 725 520 400 250 100 High-power E32-TC200 2M + E39-F1 4,000 ✽2 4,000 ✽2 4,000 ✽2 2,600 1,500 Ultrahigh-power E32-TC200 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 Side view E32-TC200 2M + E39-F2 1,170 840 700 450 160 High-power E32-T11 2M + E39-F1 4,000 ✽2 4,000 ✽2 3,600 2,300 930 Ultrahigh-power E32-T11 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 2,300 Side view E32-T11 2M + E39-F2 1,150 820 660 430 160 High-power E32-T11U 2M + E39-F1 4,000 ✽2 4,000 ✽2 3,600 2,300 930 Ultrahigh-power E32-T11U 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 4,000 ✽2 2,300 Side view E32-T11U 2M + E39-F2 1,150 820 660 430 160 High-power E32-T11NU 2M + E39-F1 4,000 ✽2 2,600 2,000 1,300 500 Ultrahigh-power E32-T11NU 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 3,300 1,300 High-power E32-T81R-S 2M + E39-F1 4,000 ✽2 2,650 2,100 1,300 520 Ultrahigh-power E32-T81R-S 2M + E39-F16 4,000 ✽2 4,000 ✽2 3,600 2,300 900 Side view E32-T81R-S 2M + E39-F2 500 360 280 180 70 High-power E32-T61-S 2M + E39-F1 4,000 ✽2 4,000 ✽2 3,400 2,200 900 Ultrahigh-power E32-T61-S 2M + E39-F16 4,000 ✽2 4,000 ✽2 4,000 ✽2 3,900 1,500 Side view E32-T61-S 2M + E39-F2 840 600 450 300 120 Narrow vision field (aperture angle: 4°) Top view E32-T22S 2M 3,500 2,500 1,900 1,250 500 Side view E32-T24S 2M 2,400 1,750 1,300 870 350 High-power Top view E32-D16 2M 40 to 1,400 40 to 1,000 40 to 700 40 to 450 40 to 240 ✽1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm. ✽2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Fiber Unit Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Minute object detection (Small-spot model) Sensing method Reflective models Sensing distance (unit: mm) Spot diameter (mm) Focal length (mm) φ0.1 to 0.6 (Variable) 6 to 15 E32-C42 1M + E39-F3A Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm φ0.3 to 1.6 (Variable) 10 to 30 E32-C42 1M + E39-F17 Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm Model Tough mode Reflective models High-speed mode 5 E32-C42S 1M 7 E32-C41 1M + E39-F3A-5 Spot diameter of 0.1 mm at 7 mm φ0.2 17 E32-C41 1M + E39-F3B Spot diameter of 0.2 mm at 17 mm 7 E32-C31 2M + E39-F3A-5 Spot diameter of 0.5 mm at 7 mm 17 E32-C31 2M + E39-F3B Spot diameter of 0.5 mm at 17 mm φ6 50 E32-L15 2M φ4 Parallel light 0 to 20 φ3 50 φ0.5 Spot diameter of 6 mm at 50 mm Sensing distance in all mode (40 to 100 mm) E32-C31 2M + E39-F3C Spot diameter of 4 mm max. at 0 to 20 mm E32-C11N 2M + E39-F18 Spot diameter of 3 mm at 50 mm E32-CC200 2M + E39-F18 Spot diameter of 3 mm at 50 mm Amplifier Unit Area range 11mm E3X-DA@R-S (@: 21/51/7/9) Sensing distance (unit: mm) Sensing direction Model Tough mode High-resolution mode Standard mode High-speed mode Super-highspeed mode 220 Side view E32-T16PR 2M 1,550 1,100 840 560 Flat view E32-T16JR 2M 1,370 980 750 480 190 E32-T16WR 2M 2,000 1,700 1,300 850 340 350 250 150 100 45 30mm 11mm Super-highspeed mode Spot diameter of 0.1 mm at 5 mm Area-sensing (Area beam) Throughbeam models Standard mode φ0.1 Fiber Unit Sensing method High-resolution mode Side view E32-D36P1 2M For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 11 E3X-DA-S E3X-DA@R-S (@: 21/51/7/9) Fiber Unit Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Detection without background interference (Convergent-reflective) Sensing method Sensing direction Size Flat view Reflective models Top view Tough mode High-resolution mode Standard mode High-speed mode Standard E32-L16-N 2M ✽ Small E32-L24S 2M ✽ 0 to 4 E32-L25L 2M ✽ 5.4 to 9 (center 7.2) E32-L24L 2M ✽ 2 to 6 (center 4) --- Flat view Model Sensing distance (unit: mm) Super-highspeed mode 0 to 15 0 to 12 ✽ If operation is affected by the background, perform power tuning to reduce the amount of light that is received. Fiber Unit Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Detection of transparent objects (Retro-reflective) Sensing method Retroreflective models Type Sensing distance (unit: mm) Model Tough mode Square E32-R16 5M + E39-R1 (attached) ✽1 Small E32-R21 2M + E39-R3 (attached) ✽1 Film detection ✽2 High-resolution mode Standard mode High-speed mode Super-highspeed mode 150 to 1,500 10 to 250 E32-C31 2M + E39-F3R+E39-RP37 ✽1 250 200 150 100 50 E32-C31 2M + E39-F3R+E39-RSP1 ✽1 600 300 225 150 75 ✽1. When using a highly reflective object, light reflected from the object may affect the sensor. ✽2. The effect may be small due to the film. Also, stable detection may not be possible when there is a sensing object directly in front of the Lens Unit. Be sure to check operation in advance. Fiber Unit Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) FPD / Semiconductor / Solar battery industry Sensing method Application Operating temperature Glass detection 70°C Glass substrate alignment Reflective models Glass substrate mapping WET process Throughbeam models Wafer mapping Sensing distance (unit: mm) Model Tough mode High-resolution mode Standard mode E32-L16-N 2M ✽ 0 to 15 E32-L16-N 2M ✽ 0 to 15 High-speed mode Super-highspeed mode 0 to 12 0 to 12 E32-A08 2M ✽ 10 to 20 300°C E32-A08H2 3M ✽ 10 to 20 70°C E32-A09 2M 15 to 38 150°C E32-A09H 2M 15 to 38 300°C E32-A09H2 2M 20 to 30 60°C E32-L11FP 5M 8 to 20 mm from end of lens (recommended: 11 mm) 70°C E32-L12FS 5M 8 to 20 mm from end of lens (recommended: 11 mm) 85°C E32-L11FS 5M 70°C 8 to 20 mm from end of lens (recommended: 11 mm) E32-A03 2M 1,610 1,150 890 600 250 E32-A03-1 2M 1,610 1,150 890 600 250 E32-A04 2M 640 460 340 225 100 E32-A04-1 2M 640 460 340 225 100 ✽ If operation is affected by the background, perform power tuning to reduce the amount of light that is received. Fiber Unit Amplifier Unit E3X-DA@R-S (@: 21/51/7/9) Liquid-level detection model Sensing method Sensing direction Sensing distance (unit: mm) Pipe diameter No limit Reflective Mounted to pipe models Wet φ8 to 10mm --- Model E32-D36T 5M ✽ E32-L25T 2M Tough mode High-resolution mode High-speed mode Super-highspeed mode Applicable pipe: Transparent (no restriction on diameter) Applicable pipe: Transparent pipe with diameter of 8 to 10 mm, recommended pipe wall thickness: 1 mm E32-D82F1 4M ✽ ✽ If a high level of light is received, perform power tuning to reduce the amount of light that is received. For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 12 Standard mode Wet model E3X-DA-S I/O Circuit Diagrams NPN Output Model Operation mode Timing charts Light-ON ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) E3X-DA21-S E3X-DA21R-S E3X-DA21F-S Operation selector ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) Dark-ON E3X-DA21-S ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) DARK ON (D-ON) Operation mode Timing charts Operation selector Light-ON ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black (orange) leads) Dark-ON Operation indicator (orange) ch1 Brown Load Black Control output Load Orange ch1 Photoelectric Sensor main circuit Control output ch2 ✽1 Pink 12 to 24 VDC External input ✽2 Blue DARK ON (D-ON) LIGHT ON (L-ON) E3X-DA7-S E3X-DA7R-S E3X-DA7F-S Operation indicator (orange) ch2 Display LIGHT ON (L-ON) ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) Light-ON Output circuit ✽1. For the E3X-DA21R-S, this is the APC alarm output. This output does not exist on the E3X-DA21F-S. ✽2. This input does not exist the E3X-DA21F-S. E3X-DA7-S Operation indicator (orange) ch2 Display Operation indicator (orange) ch1 Brown Load Black Control output Load Orange ch1 Control output ch2 ✽ Photoelectric Sensor main circuit 12 to 24 VDC Blue ✽ For the E3X-DA7R-S, this is the APC alarm output. This output does not exist on the E3X-DA7F-S. PNP Output Model E3X-DA51-S E3X-DA51R-S E3X-DA51F-S Dark-ON Light-ON E3X-DA9-S E3X-DA9R-S E3X-DA9F-S Dark-ON ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black (orange) leads) ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black (orange) leads) ch1/ Incident light ch2 No incident light Operation indicator ON (orange) OFF ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black (orange) leads) Output circuit E3X-DA51-S Operation indicator (orange) ch2 Display LIGHT ON (L-ON) Brown Operation indicator (orange) ch1 External input ✽2 Pink Control output ch1 Black Photoelectric Sensor main circuit Control output Blue DARK ON (D-ON) 12 to 24 VDC Orange ch2 ✽1 Load Load ✽1. For the E3X-DA51R-S, this is the APC alarm output. This output does not exist on the E3X-DA51F-S. ✽2. This input does not exist the E3X-DA51F-S. E3X-DA9-S Operation indicator (orange) ch2 Display LIGHT ON (L-ON) Operation indicator (orange) ch1 Brown Photoelectric Sensor main circuit Control output ch1 Black Control output Orange ch2 ✽ Load Blue 12 to 24 VDC Load DARK ON (D-ON) ✽ For the E3X-DA9R-S, this is the APC alarm output. This output does not exist on the E3X-DA9F-S. Note: 1. Operation with area settings is as follows: LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2. DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2. 2. Timing Charts for Timer Settings (T: Set Time) ON delay OFF delay One-shot ON delay and OFF delay Incident light Incident light Incident light Incident light No incident light No incident light No incident light No incident light L-ON OFF D-ON T ON ON OFF L-ON OFF T D-ON T ON ON OFF L-ON OFF T D-ON T ON ON OFF L-ON OFF T D-ON T1 T2 T2 T1 ON T1: ON-delay set time T2: OFF-delay set time T1 and T2 can be set separately. ON OFF 13 E3X-DA-S Nomenclature Amplifier Units E3X-DA@-S (@: 21/51/7/9) Main Display (Red) Sub-Display (Green) Incident level, function, etc. Threshold, function settings, etc. Operation Keys Function setting operations Lock lever Locks the fiber. Operation Indicator (ch1) (orange) Operation Indicator (ch2) (orange) ON when output is ON. ON when output is ON. OFF when output is OFF. OFF when output is OFF. UP DOWN MODE Channel Selector Note: Nomenclature and operating procedures for the E3XDA@R-S and E3X-DA@F-S (@: 21/51/7/9) are given on pages 19 and 20. Use to select the channel to display and set. Mode Selector Use to select SET or RUN Mode. Operating Procedure 1 Setting the Operation Mode To restore the default power setting: The operation mode is set in SET Mode. ➜Refer to 5. Setting Functions on page 16. MODE ✽ Press the DOWN Key right after pressing the MODE Key. Set the Channel Selector Switch to the desired channel before making any adjustments or settings. 2 DOWN PTUN OFF Incident level Threshold Press both for 3 s. "OFF" will flash twice. Adjusting the Power (RUN Mode) The current incident light level can be adjusted near the power tuning target value (default: 2,000). This restores the default setting. ✽ Confirm that the MODE Key setting is PTUN (power tuning). The default setting is PTUN. ➜Refer to 5. Setting Functions on page 16. ✽ Setting Errors An error has occurred if one of the following displays appears after the progress bar is displayed. ✽ If power tuning is executed while SHS is selected for the detection function, the minimum power will be set. Display Flashes twice Set the SET/RUN Mode Selector Switch to RUN. Incident level Threshold (default) PTUN RUN OVER (Factory-set to RUN) Flashes twice MODE 3s PTUN 3 Display changes after specific time. Incident level BOTM Action The power will not be tuned. The power can be increased up to approximately 5 times the incident light value. Bottom Error The incident light level is too high for the power tuning target value. The power will be turned to the minimum level. The power can be decreased down to approximately 1/20th the incident light value. Setting Thresholds Manually (RUN Mode) A threshold can be set manually. A threshold can also be adjusted manually after teaching to fine-tune it. Power tuning target value This completes the adjustment. PTUN Error Over Error The incident light level is too low for the power tuning target value. Progress bar Release the key after the progress bar is displayed. Set the Mode Selector Switch to RUN. Threshold Light level Threshold (default) RUN (Factory-set to RUN) UP Increases threshold. DOWN Decreases threshold. ✽ Even if the display method is changed, the threshold will appear on the sub-display when the key is pressed. 14 ✽ E3X-DA-S 4 Teaching the Threshold (SET Mode) ✽ There are five methods that can be used for teaching, as described below. Use the method most suitable for the application. ✽ Two-point teaching, positioning teaching, and automatic teaching can be performed in RUN Mode. For operating procedures, refer to the Instruction Manual provided with the product. ✽ An error has occurred if OVER or LO is displayed on the sub-display. If that occurs, repeat the operation from the beginning. 4-1. Setting the Threshold at Maximum Sensitivity The threshold can be set to the maximum sensitivity. This is useful when the longest detection distance is required. Set the SET/RUN Mode Selector Switch to SET. Incident level ➜Refer to 5. Setting Functions on page 16. Set the SET/RUN Mode Selector Switch to SET. Incident level Threshold SET UP DOWN With no workpiece: TECH Press either for 1 s. ---- "----" will be displayed. UP Press either for 3 s. DOWN With no workpiece: FULL UP DOWN Press either for 3 s. Threshold The threshold that was set will flash twice. RFCT Threshold Incident level Threshold The threshold that was set will flash twice. Incident level Set the SET/RUN Mode Selector Switch to RUN to complete the setting procedure. Threshold 4-2. Teaching a Through-beam Fiber Unit without a Workpiece You can set the threshold to below the incident light level without a workpiece by the percentage set for the teaching level. ➜Refer to 5. Setting Functions on page 16. Set the SET/RUN Mode Selector Switch to SET. You can set the threshold to above the incident light level without a workpiece by the percentage set for the teaching level. Threshold SET Set the SET/RUN Mode Selector Switch to RUN to complete the setting procedure. 4-3. Teaching a Reflective Fiber Unit without a Workpiece Incident level 4-4. Two-point Teaching 4-5. Positioning Teaching Two points in the following figures are detected, and the intermediate point of the light levels for the two points is set as the threshold. Set the SET/RUN Mode Selector Switch to SET. Threshold Incident level Threshold SET SET UP Press either for 1 s. DOWN With no workpiece: TECH ---- "----" will be displayed. With a workpiece: For positioning teaching, place the workpiece where you want to position it. UP DOWN Press either for 1 s. Workpiece TECH ---- "----" will be displayed. RUN To RUN THRU Threshold The threshold that was set will flash twice. Incident level This completes the setting procedure. Threshold With no workpiece: For positioning teaching, place the workpiece where you want to position it. UP DOWN 2PNT Threshold Incident level Threshold Press either for 1 s. The threshold that was set will flash twice. Set the SET/RUN Mode Selector Switch to RUN to complete the setting procedure. 15 E3X-DA-S 5 Setting Functions (SET Mode) Moving between Functions ➜Refer to 4. Teaching the Threshold on page 15. 0. Operation mode Teaching Set the SET/RUN Mode Selector Switch to SET. ✽ The function transition boxes show the default settings. ✽ More functions may be displayed depending on the detailed settings. 1. Detection (To change response speed and detection precision) (To set the operation mode) 2. Timer (To use the timer setting) 3. Teaching level (To change the teaching level) SET 4. ATC setting 11. External input memory MODE (Refer to the Instruction Manual provided with the sensor.) 10. External input (To change functions controlled using the external input) When the settings have been completed 9. Output setting 8. ECO Mode (To change outputs for channel 2) (To set the ECO Mode) (To change the ATC setting) 7. Display orientation (To reverse the orientation of the display.) 6. Display switch 5. MODE Key (To change the display method) (To change the function of the MODE Key during operation) Set the SET/RUN Mode Selector Switch to RUN. RUN Functions UP DOWN Use the UP and DOWN Keys to change the settings. Function ✽ Setting (display) 0. Operation mode Light ON: 1. Detection ✽ Super-high-speed: High-resolution: Description ➜Refer to 1. Setting the Operation Mode on page 14. , Dark ON: , High-speed: , Standard: , , Tough: , Differential operation: Used to change the response speed or detection precision. Differential edge (differential operation selected) Single edge: Differential time Single edge···250 µs: , 500 µs: , 1 ms: , 10 ms: , 100 ms: , Double edge···500 µs: , 1 ms: , 2 ms: , 20 ms: , 200 ms: Used to set the differential response time. Timer disabled: , OFF-delay timer: ON-delay timer: , One-shot timer: ON-delay + OFF-delay timer: Used to enable or disable timers. 2. Timer Time (timer enabled) Setting range: 4. ATC setting ATC enabled: 5. MODE Key ✽ Power tuning target value (performing power tuning) Used to set the edge to be detected. , 1 to 20 ms: 1-ms increments, 20 to 200 ms: 10-ms increments, Used to change timer settings when timers are enabled. 200 ms to 1 s: 100-ms increments, 1 to 5 s: 1-s increments The timer can be set from 1 to 5,000 ms. 3. Teaching level Setting at Power-ON (ATC ON) , Double edge: Used to change the threshold setting when teaching a Through-beam Fiber Unit without a workpiece or teaching a Reflective Fiber Unit without a workpiece. to Used to enable or disable the ATC function. , ATC disabled: No setting: , ATC start processing: Power tuning and ATC start processing: Executes power tuning: Executes a zero reset: Automatic teaching: Used to set the processing to be performed when the power is turned ON. , , , Two-point teaching: , ATC start: Setting range: 100 to 3,900 (increments of 100) Maximum power : , Used to change the function of the MODE Key during RUN operation. Used to set target values during power tuning. ➜Refer to 2. Adjusting the Power on page 14. ✽ The detection settings and MODE Key settings are the same for channel 1 and channel 2. Other functions can be set separately for each channel. 16 E3X-DA-S Function 6. Display switch Setting (display) Description Incident level Threshold Used to display the incident light level and the threshold. % incident level Threshold Used to display the incident light level as a percentage of the threshold and the threshold. PEAK BOTM L-PE D-BT Used to display the peak and bottom levels of incident light within a set time. (Updated every 2 s.) Fixed interval Use to display the incident light peak level and no incident light bottom level. (Refreshed when output turns ON or OFF.) Analog bar display. The current detection status is displayed as an analog bar. The bar will lengthen from the right as ON status is reached. (ON: Red, OFF: Green) Detection status Current incident level PEAK Fixed interval Current incident Peak incident level level Used to display the incident light level and the channel (unit number). Incident level Channel (unit number) 7. Display orientation Normal display: , Up/down reversed display: 8. ECO Mode Lit degital display: OFF: , Dimmed degital display: 9. Output setting Each channel: , Output when the incident light level is between two thresholds: Self-diagnosis output: 10. External input Through-beam, no-workpiece teaching: , Reflective, no-workpiece teaching: , Two-point teaching: , Automatic teaching: Power tuning: , Zero reset: , Light OFF: , ATC start: 11. External input memory Write results to EEPROM: , Do not write results to EEPROM: Used to display the current incident light level and the peak incident light level. Display changes at a fixed interval. Used to reverse the orientation of the display. , Used to enable or disable the ECO mode. , , Used to change the output details for channel 2. This setting will be disabled if the detection function is set to DIFF (i.e., differential operation) and the output will be used for an alarm output. Used to change the functions to be controlled using the external input. (Refer to the Instruction Manual provided with the sensor.) Used to set writing the results. (Refer to Instruction Manual provided with the product.) 17 E3X-DA-S 6 Convenient Functions 6-1. Setting the Digital Display to Zero (Zero Reset) 6-3. Resetting Settings (Initial Reset or User Reset) The incident light level on the main display can be set to 0. The incident light level and the threshold will both be shifted. This is useful when you want to set the reference display to zero. All settings can be returned to the factory defaults or to user-saved settings. Set the SET/RUN Mode Selector Switch to SET. DOWN SET ✽ Change the function to 0RST (zero reset) with the MODE Key. The default setting is PTUN. ➜Refer to 5. Setting Functions on page 16. RST Set the SET/RUN Mode Selector Switch to RUN. UP INIT RST MODE UP Press both for 5 s. USER DOWN 3s RUN MODE MODE Factory setting To return to original value for incident light level: Set the SET/RUN Mode Selector Switch to RUN. DOWN MODE RUN USER YES? USER NO? ✽1 Press both for 3 s. UP MODE DOWN MODE Factory setting Perform user reset. 6-2. Locking the Keys (Key Lock) (The steps within the dotted lines can be used if settings have been saved by the user.) All key operations can be disabled. Set the SET/RUN Mode Selector Switch to RUN. Operation canceled. UP MODE RUN ✽2 Press both for 3 s. INIT NO? INIT YES? Factory setting LOC ON UP MODE “LOC ON” will flash twice and key operations will be disabled. DOWN Operation canceled. MODE Settings initialized. To release the lock: Set the SET/RUN Mode Selector Switch to RUN. UP MODE RUN ✽2 Press both for 3 s. Saving User Settings The current settings can be saved. Set the SET/RUN Mode Selector Switch to SET. Factory setting UP SET LOC Press both for 5 s. OFF “LOC OFF” will flash twice and key operations will be enabled. ✽ If a key is pressed while key operations are locked, “LOC ON” will flash twice on the display to indicate that key operations have been disabled. ✽1. Press the DOWN Key right after pressing the MODE Key. ✽2. Press the UP Key right after pressing the MODE Key. 18 MODE SAVE YES? MODE SAVE UP DOWN The current settings are saved. NO? MODE Operation canceled. E3X-DA-S Nomenclature Amplifier Units E3X-DA@R-S (@: 21/51/7/9) Main Display (Red) Sub-Display (Green) Incident level, function, etc. Threshold, function settings, etc. Operation Keys Lock lever Function setting operations Locks the fiber. Operation Indicator (orange) APC alarm output indicator (orange) ON when output is ON. OFF when output is OFF. ON when output is ON. OFF when output is OFF. UP DOWN MODE Easy key lock Selector Select to lock or unlock settings. Mode Selector Use to select SET or RUN Mode. Operating Procedure Basic operating procedures are as given on pages 14 to 18. For details, refer to the Instruction Manual provided with the product. This section shows functions specific to the E3X-DA@R-S. 1 Locking the Keys (Easy Key Lock) Before shipment, all key operation except for the MODE Keys can be disabled. Set the SET/RUN Mode Selector Switch to RUN. Margin APC Margin APC Margin APC Initial status Set the Easy Key Lock Selector Switch to Locked . Locked APC margin displayed in decrements of 10% RUN (Factory-set to RUN) Note: Do not switch the lock while in SET Mode. Doing so will disable changing settings. If the lock is switched to in SET Mode, return to the unlock state, and then make the setting again. Unlocking Set the SET/RUN Mode Selector Switch to RUN. Set the Easy Key Lock Selector Switch to Unlocked . APC margin of less than 10% Unlocked The display switches every second. ALAT APC Margin APC RUN (Factory-set to RUN) 2 Displaying the APC Margin Displaying the APC margin can be useful for planning maintenance. When the APC margin is 0%, APC alarm output will turn ON, and the APC alarm output indicator will light regardless of the operation of the APC margin display. Set the SET/RUN Mode Selector Switch to RUN. The display switches every 0.5 s. END APC Set the Easy Key Lock Selector Switch to Locked . Locked RUN Press the MODE Key or press nothing for 10 s. (Factory-set to RUN) Press the MODE Key to display the following for 10 s. APC margin is 0%. MODE MODE The display will return to the normal display. Incident level Threshold 19 E3X-DA-S Nomenclature Amplifier Units E3X-DA@F-S (@: 21/51/7/9) Main Display (Red) Sub-Display (Green) Incident level, function, etc. Threshold, function settings, etc. Operation Keys Lock lever Function setting operations Locks the fiber Operation Indicator (orange) UP DOWN MODE Easy key lock Selector Power tuning indicator (orange) Select to lock or unlock settings. ON when setting is ON. ON when output is ON. OFF when output is OFF. OFF when setting is OFF. Mode Selector Use to select SET or RUN Mode. Operating Procedure Basic operating procedures are as given on pages 14 to 18. For details, refer to the Instruction Manual provided with the product. This section shows functions specific to the E3X-DA@F-S. 1 Locking the Keys (Easy Key Lock) Before shipment, all key operation except for the MODE Keys can be disabled. A STAT "STAT" will be displayed and the slow-motion display will start. Set the Easy Key Lock Selector Switch to Locked . Set the SET/RUN Mode Selector Switch to RUN. "A" is displayed when the output is ON or until approximately 10 s has elapsed. (Key operations will not be accepted in the status.) Locked RUN (Factory-set to RUN) Note: Do not switch the lock while in SET Mode. Doing so will disable changing settings. If the lock is switched to in SET Mode, return to the unlock state, and then make the setting again. Unlocking Set the Easy Key Lock Selector Switch to Unlocked . Set the SET/RUN Mode Selector Switch to RUN. The incident level in intervals of 17 µs will be displayed for approximately 20 s every 160 ms (between 0.5 ms before ON to 1.5 ms after ON). Incident level Threshold Incident level Threshold Incident level Threshold Unlocked RUN (Factory-set to RUN) 2 Displaying the Change of the incident level Press the MODE Key, or wait for the slow-motion display to end. Changes of the incident level for high-speed workpiece detection can be displayed. This enables checking the margin level of light received and the workpiece ON time in slow motion. Set the Easy Key Lock Selector Switch to Locked . Set the SET/RUN Mode Selector Switch to RUN. The output ON time will be displayed. MODE Output ON time Unit: µs Locked RUN (Factory-set to RUN) END Incident level END will be displayed. Threshold Turn OFF the output or convey the workpieces. Incident level Press the MODE key. Error Display 20 The following will be displayed if the ON time exceeds 1,500 µs. OVER US Threshold The display will return to the normal display. MODE The following will be displayed if the change in the light amount is low. ✽ NON DETC ✽ This may also be displayed when detecting a workpiece with a small change in light amount or a slow workpiece of 1,500 µs or longer. E3X-DA-S Safety Precautions To ensure safe operation, be sure to read and follow the Instruction Manual provided with the sensor. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. CAUTION Do not use the sensor with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. Never use the sensor with an AC power supply. Otherwise, explosion may result. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Amplifier Unit Designing Operation after Turning Power ON The sensor is ready to detect within 200 ms after the power supply is turned ON. If the sensor and load are connected to separate power supplies, be sure to turn ON the sensor first. Time may be required for the incident level to stabilize after the power supply is turned ON. Operation at Power OFF A pulse may be output when the power supply is turned OFF. Turn OFF the power supply to the load or the load line before turning OFF the power supply to the sensor. Precautions for Safe Use The following precautions must be observed to ensure safe operation of the sensor. 1. Do not use the sensor in an environment where explosive or flammable gas is present. 2. Do not use the sensor in a location subject to splattering with water, streams, oils, or chemicals. 3. Do not attempt to disassemble, repair, or modify the sensor. 4. Do not apply voltages or currents that exceed the rated range to the sensor. 5. Do not use the sensor in an ambient atmosphere or environment that exceeds the ratings. 6. Wire the power supply correctly, including the polarity. 7. Connect the load correctly. 8. Do not short-circuit the load at both ends. 9. Do not use the sensor if the case is damaged. 10.Dispose of the sensor as industrial waste. 11.Do not use the sensor in locations subject to direct sunlight. Mutual Interference Protection Function Mutual interference prevention is enabled if Amplifier Units are connected together. It is also enabled in the same way if E3X-DA-Sseries Units and E3C-LDA-series Units are used together. Mounting Connecting and Disconnecting Connectors Mounting Connectors 1. Insert the Master or Slave connector into the Amplifier Unit until it clicks into place. Insert 2. Attach the protective seals (provided as accessories) to the sides of master and slave connectors that are not connected. Seal Note: Attach the seals to the sides with grooves. Removing Connectors 1. Slide the slave Amplifier Unit away from the other unit. 2. After the Amplifier Unit has been separated, press down on the lever on the connector and remove it. (Do not attempt to remove a connector without first separating the Amplifier Unit from the other Units.) Press down Lever Remove 21 E3X-DA-S Adding and Removing Amplifier Units Fibers with E39-F9 Attachment Adding Amplifier Units 1. Mount the Amplifier Units one at a time onto the DIN track. Fiber Unit 9 mm 13 mm Fibers That Cannot Be Free-Cut (with Sleeves) 2. Slide the Amplifier Units together, line up the clips, and press the Amplifier Units together until they click into place. Click into place 9 mm 13 mm Removing Amplifier Units Slide Amplifier Units away from each other, and remove from the DIN track one at a time. (Do not attempt to remove Amplifier Units from the DIN track without separating them first.) 2. Disconnecting Fibers Remove the protective cover and raise the lock lever to pull out the fibers. Note: 1. The specifications for ambient temperature will vary according to the number of Amplifier Units used together. For details, ➜refer to Ambient temperature range on page 4. 2. Always turn OFF the power supply before joining or separating Amplifier Units. Protective cover Locked Unlocked Mounting the End Plate (PFP-M) Use an End Plate if the Amplifier Unit might move due to vibration. Note: 1. To maintain the fiber properties, confirm that the lock is released before removing the fibers. 2. Be sure to lock or unlock the lock lever within an ambient temperature range between −10°C and 40°C. Adjusting Mutual Interference Protection Function The values that appear on the digital display may fluctuate somewhat due to light from other sensors. If this occurs, you can stabilize detection by setting a threshold that is close to half way between the incident levels with and without a sensing object. End Plate Fiber Connection The E3X Amplifier Unit has a lock lever for easy connection of the Fiber Unit. Connect or disconnect the fibers using the following procedures: 1. Connecting Fibers Open the protective cover, insert the fibers according to the fiber insertion marks on the side of the Amplifier Unit, and lower the lock lever. Protective cover Lock lever Locked Unlocked Insertion position Output Short-circuits OVER/CUR will flash on the display if the output short-circuit protection function operates due to a load short-circuit in a control output. If this occurs, check the load connections. EEPROM Writing Error If the data is not written to the EEPROM correctly due to a power failure or static-electric noise, initialize the settings with the keys on the Amplifier Unit. ERR/EEP will flash on the display when a writing error has occurred. Optical Communications Several Amplifier Units can be slid together and used in groups. Do not, however, slide the Amplifier Units or attempt to remove any of the Amplifier Units during operation. Others Protective Cover Fiber insertion mark Always keep the protective cover in place when using the Amplifier Unit. Fiber 9 mm Note: Do not pull on the fiber, apply pressure on it, or otherwise subject it to excessive force when it is attached to the Amplifier Unit. (Use a force of 0.3 N·m max.) Mobile Console The E3X-MC11-SV2 Mobile Console does not currently support the new Tough Mode and ON-delay + OFF-delay timer. You also cannot use the E3X-MC-S. Communications Unit Use an E3X-DRT21-S Version 3 Communications Unit. This is not supported for the E3X-DA@R-S and E3X-DA@F-S (@: 21/51/7/9). 22 E3X-DA-S (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Amplifier Units Pre-wired Models E3X-DA21-S E3X-DA51-S E3X-DA21R-S E3X-DA51R-S E3X-DA21F-S E3X-DA51F-S Digital Display Area ✽1. The indicators are as follows: Indicator ✽1 15.6 35.25 10 6.3 Operation indicator (1ch) Main display Sub-display E3X-DA21-S E3X-DA51-S Operation indicator (2 ch) E3X-DA21R-S E3X-DA51R-S APC alarm output indicator E3X-DA21F-S E3X-DA51F-S Power tuning indicator DIN track mounting 4.3 141.1 180° 101.45 Vinyl-insulated round cable Standard length: 2 m ✽2 32 (9) 4.5 Multiple connection diagram 12.5 5.65 3.4 End Plate (sold separately) PFP-M L Two, 2.4 dia. Hole for optical communications 18.7 (36.2) (21.3) 70 Center of DIN track DIN track (sold separately) PFP-@N 10 The number of expansion 1 2 3 4 5 6 7 8 9 10 Fiber Attachment mounted (E39-F9) 10 With Mounting Bracket Attached 4.3 10 L (mm) 10 20 30 40 50 60 70 80 90 100 141.1 180° 101.45 Vinyl-insulated round cable Standard length: 2 m ✽2 32 (9) 4.5 12.5 5.65 3.4 Two, 2.4 dia. 10.3 Two, 3.2 dia. Holes 18.7 Hole for optical communications 4.3 (9.4) 16 70 Mounting Bracket (E39-L143) SUS304 stainless steel (sold separately) Mounting Holes 3.4 2-M3 4.4 16 28.1 16 Fiber Attachment mounted (E39-F9) Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier Units if they are mounted side by side. ✽2. The cable specifications are as follows: E3X-DA21-S E3X-DA51-S E3X-DA21R-S E3X-DA51R-S 4 dia. cable / 5 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm) E3X-DA21F-S E3X-DA51F-S 4 dia. cable / 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm) 23 E3X-DA-S Wire-saving connector Models E3X-DA7-S E3X-DA9-S E3X-DA7R-S E3X-DA9R-S 10 E3X-DA7F-S E3X-DA9F-S ✽1. The indicators are as follows: Digital Display Area Indicator ✽1 15.6 35.25 6.3 Operation indicator (1ch) Main display Sub-display E3X-DA7-S E3X-DA9-S Operation indicator (2 ch) E3X-DA7R-S E3X-DA9R-S APC alarm output indicator E3X-DA7F-S E3X-DA9F-S Power tuning indicator DIN track mounting 4.3 141.1 8.1 180° 101.45 Dia. A ✽2 32 (9) 4.5 12.95 5.65 3.4 Two, 2.4 dia. Hole for optical communications 18.7 (36.2) Multiple connection diagram (21.3) 70 End Plate (sold separately) PFP-M L Center of DIN track DIN track (sold separately) PFP-@N 10 10 The number of expansion 1 2 3 4 5 6 7 8 9 10 Fiber Attachment mounted (E39-F9) 10 With Mounting Bracket Attached L (mm) 10 20 30 40 50 60 70 80 90 100 4.3 141.1 8.1 180° 101.45 Dia. A ✽2 32 (9) 4.5 12.95 5.65 3.4 Two, 2.4 dia. 10.3 Two, 3.2 dia. Holes 18.7 Hole for optical communications (9.4) 16 4.3 70 Mounting Bracket (E39-L143) SUS304 stainless steel (sold separately) Mounting Holes 3.4 4.4 2-M3 ✽2. The cable diameters are as follows: 16 28.1 16 Fiber Attachment mounted (E39-F9) Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier Units if they are mounted side by side. 24 E3X-CN21 (4 conductors) E3X-CN22 (2 conductors) 4.0 dia. E3X-CN11 (3 conductors) E3X-CN12 (1 conductor) 2.6 dia. E3X-DA-S Wire-saving connector Master connector E3X-CN21 2,000+50 0 Edge of amplifier (7) ✽ ✽ E3X-CN21: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm) Slave connector E3X-CN22 2,000+50 0 Edge of amplifier (7) ✽ ✽ E3X-CN22: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm) Master connector E3X-CN11 2,000+50 0 Edge of amplifier (7) ✽ ✽ Cable 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm) Slave connector E3X-CN12 2,000+50 0 Edge of amplifier (7) ✽ ✽ Cable 2.6-dia. vinyl-insulated round cable with 1 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm) 25 E3X-DA-S Accessories (sold separately) Mounting Brackets E39-L143 34.8 22 16 2.5 (10.3) 3 Mounting Holes 7.3 5.3 2-M3 26.8 Two, 3.2 dia. 3 16 7 16±0.1 3 Four, R1.7 3.4 10.3 10 max. 7 Material: Stainless steel (SUS304) 1 3.4 End Plate PFP-M 11.5 1 50 M4×8 panhead screw 10 M4 spring washer 4.8 6.2 10 1 1.3 1.8 35.5 1.8 35.3 For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). 26 READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit Carl-Benz-Str. 4, D-71154 Nufringen, Germany Tel: (49) 7032-811-0/Fax: (49) 7032-811-199 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2010 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan CSM_1_1_0510 Cat. No. E396-E1-02 (0510)