ETC ER14505

R
LITHIUM BATTERY
Primary lithium batteries
ER14505
3.6V Primary lithium-thionyl chloride
(Li-SOCl 2 ) Energy type
AA-size bobbin cell
For low drain / long time
applications requesting superior
voltage response in -55 ~+85
environments.
Cell size references
(AA )
Electrical characteristics
(typical values relative to cells stored for one year or less at +30 max.)
Nominal capacity
(at 1 mA +20 2.0V cut off. The capacity restored by the cell varies
according to current drain, temperature and cut off).
2.4Ah
Open circuit voltage (at +20 )
3.66V
Nominal voltage
3.6V
(at 1mA +20 )
Pulse capability: Typically up to 200 mA (200 mA/0.1 second pulse
s,
drained every 2 mn at +20 from undischarged cells with 10 A base
current, yield voltage readings above 3.0V. The readings may vary according
to the pulse characteristics, the temperature, and the cell s previous history.
Fitting the cell with a capacito r may be recommended in severe conditions.
Consult pbq)
Max. Continuous current
Max. Pulse current
Storage
100mA
200mA
(recommended)
(for more severe conditions, consult pbq)
+30
Operating temperature range
(Operation above ambient T may lead to reduced capacity and
lower voltage readings at the beginning of pulses. Consult pbq)
-55
max
/ +85
Physical characteristics
Diameter (max)
14.5mm(0.55 in)
Height (max)
50.5mm(2 in)
Typical weight
19g(0.622oz)
Available termination suffix
radial tabs, radial pins, axial leads, flying leads
R
www.pbq-batteries.com
R
LITHIUM BATTERY
Characteristic curves
Discharge performance
ER14505
10
0.2
6
0.1
V
0.05
3.5
3.0
4.0
Voltage
1
25
2.5
2.5
3.5
(+)
3.0
2.0
0 1 2 3 4 5 6 7 8 9 10
(Second)
2.0
33
100
330
100mA 33mA 10mA
0.8Ah
1.3Ah 1.9Ah
1.5
1.0
0.1
51Max
1
2
10
3.5k
18k
1mA
200 A
2.4Ah 2.3Ah
3
10
4
10
5
10
10
Hours
0.4
Capacity VS Current
11 0.2
Unit:mm
2.4
20
2.2
.
14.5Max
0
Storage
The storage area should be clean,
cool (not exceeding +30 ), dry
and ventilated.
72
1.6
1.4
1.2
1.0
0.8
-30
0.6
0.4
0.01
0.1
1
Current
10
100
mA
Voltage VS Temperature
3.8
3.6
10 A
0.2mA
V
Main applications
Radiocommunication and other
military applications
Alarms and security systems
Beacons and emergency location
transmitters
GPS
Metering systems
Sonobuoys
LED lighting applications
Others
55
1.8
Voltage
Key features
High and stable operating voltage
Superior drain capability
Low self-discharge rate
(less than 1% after 1year of storage
at +20 )
Hermetic glass-to-metal sealing
Notch technology for safety vent is
recommended
Non-flammable electrolyte
Capacity Ah
2.0
3.4
1mA
3.2
3.0
5mA
Warning
Do not use if the battery casing was
mangled.
Don t use different models of battery
in series.
Do not try to recharge.
2.8
-60
-40 -20
0
20
40
60
80
Temperature
www.pbq-batteries.com