SAFT LS14250MLB

Meter lithium battery
LS 14250 MLB
3.6 V high energy
primary Li-SOCl2 battery
for utility meters
in demanding environments
Benefits
•Easy integration into utility meters
•High voltage, stable during most of the application’s lifetime
•Wide operating temperature range
•Low self-discharge rate
(less than 1 % per year of
storage at + 20°C)
Key features
1/2
AA lithium-thionyl chloride
LS 14250 component cell
•Battery with ABS plastic enclosure
•Component cell with:
- Stainless steel container
- Hermetic glass-to-metal sealing
- Non-flammable electrolyte
- Underwriters Laboratories (UL)
Component Recognition
•Battery non-restricted for transport
•Manufactured in China
•
Main applications
•Utility metering
•Automatic meter reading
•Alarms and security devices
•Memory back-up
•Professional electronics
September 2011
Electrical characteristics
(typical values relative to batteries stored for one year or less at + 30°C max.)
Nominal capacity
1.20 Ah
(at 1 mA + 20°C 2.0 V cut-off. The capacity restored by the battery varies
according to current drain, temperature and cut-off)
Open circuit voltage (at + 20°C)
3.67 V
Nominal voltage
(at 0.1 mA + 20°C)
3.6 V
Pulse capability: Typically up to 100 mA
(100 mA/0.1 second pulses, drained every 2 mn at + 20°C from undischarged
battery with 10 µA base current, yield voltage readings above 3.0 V. The readings
may vary according to the pulse characteristics, the temperature, and the
battery previous history.)
Maximum recommended continuous current
(Higher currents are possible, consult Saft)
Storage (recommended)
(for more severe conditions, consult Saft)
Operating temperature range
(Operation above ambient T may lead to reduced capacity and lower voltage readings at the beginning of pulses. Consult Saft)
35 mA
+ 30°C (+ 86°F) max
- 60°C/+ 85°C
(- 76°F/+ 185°F)
Physical characteristics
Diameter (max)
16.8 mm (0.66 in)
Height (max)
28.6 mm (1.12 in)
Typical weight
15 g (0.5 oz)
Li metal content
approx. 0.3 g
LS 14250 MLB
battery
Voltage plateau versus Current and Temperature (at mid-discharge)
3.6
+70°C
Cell voltage (V)
3.5
+ 20°C
3.4
3.3
3.2
3.1
3.0
- 20°C
2.9
2.8
2.7
- 40°C
2.6
2.5
0.01
0.1
1
10
100
Current (mA)
Typical discharge profiles at + 20°C
3.7
3.5
3.1
2.3
Dimensions in mm.
2.1
7.5 kOhms/0.5 mA
2.5
3 kOhms/1.2 mA
2.7
400 Ohms/8.5 mA
2.9
56 Ohms/54 mA
Cell voltage (V)
3.3
1.9
1
0.1
10
100
1000
10000
Time (hours)
Storage
Warning
• Fire, explosion and burn hazard.
• Do not recharge, short circuit,
crush, disassemble, heat above
100°C (212°F), incinerate,
or expose contents to water.
Restored Capacity versus Current and Temperature (2.0 V cut-off)
1200
1100
+20°C
1000
Capacity (mAh)
• The storage area should be
clean, cool (preferably not
exceeding + 30°C), dry and
ventilated.
900
800
+70°C
700
600
- 20°C
500
400
300
200
- 40°C
100
0
0.01
0.1
1
Current (mA)
Saft
Specialty Battery Group
12, rue Sadi Carnot
93170 Bagnolet - France
Tel.:+33 (0)1 49 93 19 18
Fax :+33 (0)1 49 93 19 69
313 Crescent Street
Valdese, NC 28690 - USA
Tel.:+1 (828) 874 4111
Fax :+1 (828) 874 3981
www.saftbatteries.com
Doc. Nº 31077-2-0911
Information in this document is subject to change without notice
and becomes contractual only after written confirmation by Saft.
For more details on primary lithium technologies please refer to
Primary Lithium Batteries Selector Guide Doc No 31048-2.
Published by the Communications Department.
Photo credit: Saft
Société anonyme au capital de 31 944 000
RCS Bobigny B 383 703 873
Produced in the UK by Arthur Associates Limited.
10
100