ETC F-193U

P OWER TRANSFORMER
Chassis Mount: Single Secondary
F-193U
Electrical Specifications (@25C)
1. Maximum Power: 96.0 VA
2. Primary: 115V 50/60 Hz
3. Secondary: 24.0VCT @ 4.0 Amps
4. Voltage Regulation: 10 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-193U is part of a series which has a long history of reliable service in the
field, made from a proven design and constructed with UL recognized materials.
Construction:
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
RED
BLK
Safety:
RED/YEL
These products are 100% hipot tested with an insulation of 1500V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
Dimensions:
BLK
RED
Units: In inches
A
B
C
D
E
2.812
3.125
2.812
2.50
2.125
D
Lead length: 7.0 inches + 1 inch
Weight: 4.0 lbs
.203 X .375
MTG SLOTS
4 PLACES
C
Schematic:
BLK
RED
RED/YEL
E
RED
BLK
Primary: Black to Black
Secondary: Red to Red
A
RoHS Compliance: As of manufacturing date February 2005, all standard
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
22520B Temescal Canyon Road
Corona, California
92883
B
Publish Date: August 27, 2006