ETC MS4128-5

Automation and Network Solutions
MS4128-5
Industrial Networking:Industrial Ethernet:MICE:Switches
Product description
Description
Port type and quantity
Type
Order No.
More Interfaces
Power supply/signaling contact
V.24 interface
Network size - cascadibility
Line - / star topology
Ring structure (HIPER-Ring)
Power requirements
Operating voltage
Current consumption at 24 V DC
Power consumption
Service
Management
Diagnostics
Configuration
Security
Other services
Prepared for
Redundancy
Redundancy functions
Ambient conditions
Operating temperature
Storage/transport temperature
Relative humidity (non-condensing)
MTBF
Mechanical construction
Dimensions (W x H x D)
Mounting
Weight
MICE, modular, managed Industrial EHTERNET Switch,
store and forward switching mode,
Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) and
Gigabit-Ethernet (1000 Mbit/s)
up to 28 ports possible via media modules,
4 x 1000BASE-SX with SFP modules or 4 x 10/100/1000BASE-TX and
24Fast-Ethernet (100 Mbit/s) ports
MS4128-5
943 746-001
2 plug-in terminal block, 4-pin
1 x RJ11 socket
any
50 (reconfiguration time < 50 ms)
24 V DC (-25% to +30%)
630 mA (not including media modules)
15 W (not including media modules)
serial interface, web interface SNMP v1/v2/v3, HiVision
LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, error,
redundancy manager, ring port, LED test),
cable tester,
2 x signal contact / fault relais (24 V DC / 1 A),
RMON (statistics, history, alarms, events),
port mirroring.
Comand Line Interface (CLI), TELNET, BootP, DHCP, DHCP option 82,
HIDiscovery, auto-configuration adapter (ACA21-USB)
SNMP V3 (SSH, SSL), port security, ACL, Authentication (802.1x)
QoS 4 classes, prioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP
snooping/querier, GMRP), broadcastlimiter, SNTP (simple network time protocol),
flow control IEEE 802.3x
TOS (Type of Service) Diff.-Serv, TOS-Prio-Mapping, protocol based VLANs,
Routing RIP and OSPF HIRRP / VRRP, Proxy ARP
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol),
redundant network/ring coupling, dual homing,
redundant 24 V power supply, redundant signal contact,
link aggregation dynamic and static (max. 7 trunks, 8 ports/trunk, LACP)
0 °C to +60 °C
-25 °C to +70 °C
10% to 95%
24.2 years; MIL-HDBK 217F: Gb 25 °C
315 mm x 134 mm x 140 mm
DIN Rail 35 mm
2,2 kg
1/2
Protection class
Mechanical stability
IEC 60068-2-27 shock
IEC 60068-2-6 vibration
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)
EN 61000-4-3 electromagnetic field
EN 61000-4-4 fast transients (burst)
EN 61000-4-5 surge voltage
EN 61000-4-6 conducted immunity
EMC emitted immunity
FCC CFR47 Part 15
EN 55022
Approvals
Safety of industrial control equipment
Hazardous locations
Safety of information technology equipment
Germanischer Lloyd
Scope of delivery and accessories
Scope of delivery
Accessories to order separately
IP 20
15 g, 11 ms duration, 18 shocks
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.;
3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1
octave/min.
6 kV contact discharge, 8 kV air discharge
10 V/m (80 - 1000 MHz)
2 kV power line, 1 kV data line
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
FCC CFR47 Part 15 Class A
EN 55022 Class A
cUL 508 (E175531) in preparation
cUL 1604 Class 1 Div 2 (E203960) in preparation
cUL 60950 (E168643) in preparation
Germanischer Lloyd in preparation
Device, terminal block, operating manual
ML-MS3 labels, MB-2T expansion backplane, auto-configuration adapter (ACA 21USB),
HiVision network management, 19" installation, terminal cable,
rail power supply RPS 30, RPS 60 or RPS 120
2/2