MITSUMI PST93XX

System Reset PST93XX
MITSUMI
System Reset
Monolithic IC PST93XX Series
Outline
These low reset type ICs function in a variety of CPU systems and other logic systems, to detect power
supply voltage and reset the system accurately when power is turned on or interrupted.
They are ideal for use in battery check circuits for products using batteries, as they have ultra-low current
consumption and a high precision voltage detection function.
Features
1.
2.
3.
4.
5.
6.
High precision voltage detection
VS±2% max.
Ultra-low current consumption
ICCH=2.0µA typ.
ICCL=2.0µA typ.
Low operating limit voltage
0.65V typ.
Hysteresis voltage provided in detection voltage
50mV typ.
Output current high for ON
5mA min.
Detection voltage can be selected as desired within a range of 1.9V ~ 4.6V
in 0.1V steps, as indicated below.
PST93XX
detection voltage value
.......
(Example: for 4.2V
PST9342)
Package
SC-82ABA (PST93
U)
Applications
1.
2.
3.
4.
5.
Reset circuits in microcomputers, CPUs and MPUs.
Logic circuit reset circuits.
Battery voltage check circuits.
Back-up power supply switching circuits.
Level detection circuits.
Pin Assignment
4
3
1
2
SC-82ABA
1
NC
2
GND
3
VOUT
4
VCC
System Reset PST93XX
MITSUMI
Block Diagram
Pin Description
Pin no.
Pin name
1
NC
2
GND
GND pin
3
VOUT
Reset signal output pin
4
VCC
Power supply pin/voltage detection pin
Absolute Maximum Ratings
Function
(Ta=25°C)
Item
Symbol
Rating
Units
Storage temperature
TSTG
-40~+125
°C
Operating temperature
TOPR
-20~+75
°C
Power supply voltage
VCC max.
-0.3~10
V
Allowable loss
Pd
150
mW
Recommended Operating Conditions
Item
Symbol
Rating
Units
Operating temperature
TOPR
-20~+75
°C
Power supply voltage
VCC
+0.85~+10
V
System Reset PST93XX
MITSUMI
Electrical Characteristics
Item
Detection voltage
Hysteresis voltage
Detection voltage
temperature coefficient
Low-level output voltage
Output leakage current
Circuit current while on
Circuit current while off
"H"transport delay time
"L"transport delay time
Operation limit voltage
Output current while on 1
Output current while on 2
*1 : t
*2 : t
(Ta=25°C)
Symbol
Measurement
circuit
Measurement conditions
Min. Typ. Max. Units
1
PST9346
PST9345
PST9344
PST9343
PST9342
PST9341
PST9340
PST9339
PST9338
PST9337
PST9336
PST9335
PST9334
VCC=H L
RL=4.7kΩ
PST9333
VOL <= 0.4V
PST9332
PST9331
PST9330
PST9329
PST9328
PST9327
PST9326
PST9325
PST9324
PST9323
PST9322
PST9321
PST9320
PST9319
VCC=L H L, RL=4.7kΩ
4.508
4.410
4.312
4.214
4.116
4.018
3.920
3.822
3.724
3.626
3.528
3.430
3.332
3.234
3.136
3.038
2.940
2.842
2.744
2.646
2.548
2.450
2.352
2.254
2.156
2.058
1.960
1.862
30
Vs / T
1
VOL
IOH
ICCL
ICCH
TPLH
TPHL
VOPL
IOL1
IOL2
1
1
1
1
2
2
1
1
1
VS
Vs
: VCC= (VS typ.-0.4v) (VS typ.+0.4v)
PHL : VCC= (VS typ.+0.4v)
(VS typ.-0.4v)
PLH
1
4.600
4.500
4.400
4.300
4.200
4.100
4.000
3.900
3.800
3.700
3.600
3.500
3.400
3.300
3.200
3.100
3.000
2.900
2.800
2.700
2.600
2.500
2.400
2.300
2.200
2.100
2.000
1.900
50
4.692
4.590
4.488
4.386
4.284
4.182
4.080
3.978
3.876
3.774
3.672
3.570
3.468
3.366 V
3.264
3.162
3.060
2.958
2.856
2.754
2.652
2.550
2.448
2.346
2.244
2.142
2.040
1.938
100 mV
RL=4.7kΩ, Ta=-20~+75°C
±0.01
%/°C
VCC=Vs min.-0.05V, RL=4.7kΩ
VCC=Vo=10V
VCC=Vs min.-0.05V, RL=∞
VCC=Vs typ./0.85, RL=∞
RL=4.7kΩ, CL=100pF
1
RL=4.7kΩ, CL=100pF
2
RL=4.7kΩ, VOL <= 0.4V
VCC=Vs min.-0.05V, Vo=0.4V
VCC=Vs min.-0.05V, Ta=-20~+75°C
0.2
2.0
2.0
20
20
0.65
*
*
5
3
0.4
±0.1
4.0
4.0
60
60
0.85
V
µA
µA
µA
µS
µS
V
mA
mA
System Reset PST93XX
MITSUMI
Measuring Circuit
(1)
S1=ON, S2=OFF : when measuring IOH, IOL1, IOL2
S1=OFF, S2=ON : for measuring other than the above
(2)
A : DC ammeter
V : DC voltmeter
CRT : Oscilloscope
INPUT PULSE
Vs typ.+0.4V
Vs typ.-0.4V
0V
System Reset PST93XX
MITSUMI
Application circuits
[CL setting]
Several tens of mV of oscillation may appear in VOUT
when VCC is near operating limit (approx. 0.7V)~1.0V, if RL
is set at more than RL.=.500kΩ in the above application
circuit. If this presents a problem, set the CL value
slightly higher (1000pF or more recommended).
*
*: Varies slightly depending on V
Characteristics
VOUT
Vs
Vs
VCC
S
rank.