MITSUMI PST70XX

IC for System Reset PST70XX
MITSUMI
IC for System Reset
Monolithic IC PST70XX Series
May 21, 2002
Outline
This IC is a low-reset type system reset IC and in a variety of CPU systems and other logic systems, to detect
supply voltage and reset the system accurately when the power is turned on or interrupted.
It includes a high-precision voltage detection function with ultra-low current consumption and is ideal for
voltage check circuits for products using a battery.
Features
1.
2.
3.
4.
5.
6.
High-precision voltage detection
Vs±2% max.
Ultra-low current consumption
ICCH=2µA typ. ICCL=3µA typ.
Low operating limit voltage
0.65V typ.
Hysteresis voltage provided for detection voltage
50mV typ.
Large output current during power-on
30mA typ.
Detection voltage can be selected as desired within a range of 1.9 to 4.6V
by 0.1V step, as indicated below.
PST70XX
Detection voltage value
(Example: for 4.6V ....... PST7046)
Packages
MMP-3A (PST70
M)
TO-92A (PST70
)
The box represents a rank of detection voltage.
*
Applications
1.
2.
3.
4.
5.
Reset circuits for microcomputers, CPUs and MPUs
Reset circuits for logic circuits
Battery voltage check circuits
Back-up power supply switching circuits
Level detection circuits
Pin Assignment
1
2
3
TO-92A
1
VCC
2
GND
3
VOUT
1
3
2
MMP-3A
(TOP VIEW)
1
VCC
2
GND
3
VOUT
IC for System Reset PST70XX
MITSUMI
Equivalent Circuit Diagram
Absolute Maximum Ratings
(Ta=25°C)
Item
Symbol
Rating
Units
Storage temperature
TSTG
-40~+125
°C
Operating temperature
TOPR
-20~+75
°C
Power supply voltage
VCC max.
-0.3~+10
V
Allowable loss
Pd
mW
300 (TO-92A)
(Ta=25°C) (Except where noted otherwise, resistance unit is Ω)
Electrical Characteristics
Item
200 (MMP-3A)
Symbol Measurement conditions Measurement circuit Min. Typ. Max. Units
4.6~
Detection voltage
RL=470 VCC=H
VS
L
1
VS typ. 1.9 VS typ.
-2% (0.1V +2%
V
Step)
VS
Hysteresis voltage
Detection voltage
temperature coefficient
V S/
T
Low-level output voltage
VOL
Output leakage current
IOH
Circuit current while on
ICCL
Circuit current while off
ICCH
"H"transport delay time
tPLH
"L"transport delay time
tPHL
Operation limit voltage
VOPL
Output current while on 1
IOL1
Output current while on 2
IOL2
RL=470 VCC=L
H
L
1
RL=470 Ta=-20~+75°C
1
±0.01
1
0.2
VCC=VS min. -0.05V
RL=470
VCC=10.0V
VCC=VS min. -0.05V
RL=∞
VCC=VS typ. /0.85V
RL=∞
30
50
1
100
%/°C
0.4
V
0.1
µA
1
3.0
6.0
µA
1
2.0
4.0
µA
RL=4.7k
7046~24
2
5
30
CL=100pF
7023~19
2
10
30
RL=4.7k
7046~24
2
30
70
CL=100pF
7023~19
2
70
150
1
0.65
0.85
RL=4.7k VOL <= 0.4V
VCC=VS min. -0.05V
RL=0
VCC=Vs min. -0.05V RL=0
Ta=-20°C~+75°C
mV
1
8
1
5
30
µs
µs
V
mA
mA
IC for System Reset PST70XX
MITSUMI
Measuring Circuit
[1]
[2]
*1
*2
0V
*1
VS+0.4V
*2
VS-0.4V