NAIS AMP1109

AMP series
2002.10.23 7:57 PM
Page 10
Motion-Detecting Sensor (AMP)
MOTION-DETECTING
SENSOR
(PASSIVE INFRARED TYPE)
AMP Series
Highly sensitive type
24×24 mm .945×.945 inch
• High detection ability
This sensor is a stable, sensitive sensor
that detects 2°C 3.6°F temperature
changes regardless of the location or
speed of the subject. In other words,
this sensor ensures detection whether a
person is at the edge of the detection
area or in the middle, regardless of how
fast they are moving.
• Low current consumption
The standard model consumes 260 µA
(during stand-by), while the low consumption current type consumes 30 µA
(during stand-by). This makes battery
operation possible.
• Wide operation voltage range (2.6 to
5.5 V DC)
The usable range extends from a
standard 5 V DC for microcomputers to
3 V DC and 4.5 V DC for battery operation.
FEATURES
• Detects even slight motion of a person (e.g. a 20 cm 7.87 inch movement of the hand)
With our unique motion detector—highly sensitive type, even slight motions
made by people will be detected easily.
• Compact lens
We have decreased the exposed portion of the lens, and at the same time
maintained a detection ability that is as
good or better than other motion sensors on the market.
Lens dimensions:
Standard sensitive type
16×20 mm .630×.787 inch
ORDERING INFORMATION
Detection performance
1: Standard sensitive type: 0.3 to 2.0 m/s
2: Highly sensitive type: 0.3 to 1.0 m/s
Ex. AMP
0
Current consumption
0: Standard type
1: Low current consumption type
• Varied operation in accordance with
the surrouding brightness
If used together with a brightness
sensor (CdS), you can make the sensor
operate only during bright hours or dark
hours.
• Output time can easily be changed
By simply changing the resistor
attached to the outside of the sensor,
the output time can be changed from
approximately 10 seconds to 6 minutes.
TYPICAL APPLICATIONS
• Lighting and ventilation control of conference rooms
• Control of illumination and exhaust fans
in toilets
• Lighting control of halls
• Nighttime lighting control of vending
machines
• Lightning control around cash dispensing machines (ATMs)
9
Lead wire
0: No lead wire type
Operating voltage
9: 2.6 to 5.5 V DC
TYPES
Detection
performance
Current consumption
Standard
sensitive type
Standard type
Highly
sensitive type
Standard type
Rated operating voltage
Part No.
Packing quantity
Inner
Outer
20 pcs.
200 pcs.
AMP1009
Low current consumption type
AMP1109
2.6 to 5.5 V DC
AMP2009
AMP2109
Low current consumption type
PERFORMANCE
1. Detection performance (Measuring conditions: ambient temp.: 25°C 77°F; operating voltage: 5V DC)
Items
Rated detection distance
Detection
range
Standard sensitive type
Highly sensitive type
Conditions of objects to be detected
1. To have more than 2°C 36°F of temperature
1. difference from background
2. Movement speed
• Standard sensitive type: 0.3 to 2.0 m/s
• Highly sensitive type: 0.3 to 1.0 m/s
3. Detection object = human body
5 m min.
2 m min.
Horizontal
95°
73°
Vertical
55°
73°
34 zones
64 zones
Detection zone
2. Absolute maximum rating (Measuring condition: ambient temp.: 25°C 77°F)
Items
Specified value
Power supply voltage
Output
(Open collector)
Voltage
Current
7V
30 V
50 mA
Usable ambient temperature
–20 to +55°C –4 to +131°F
Storage temperature
–30 to +80°C –22 to +176°F
10
Remarks
No freezing and condensing at low temperature.
AMP series
2002.10.23 7:57 PM
Page 11
Motion-Detecting Sensor (AMP)
3. Electrical characteristics (Measuring conditions: ambient temp.: 25°C 77°F; operating voltage: 5V)
Items
Symbol
Specified value
2.6 V DC
—
5.5 V DC
Measured conditions
Rated operating voltage
Minimum
Typical
Maximum
Vdd
Standby
Minimum
Typical
Maximum
Iw
Standard type: 200 µA; Low consumption current type: 12 µA
Standard type: 260 µA; Low consumption current type: 30 µA
Standard type: 560 µA; Low consumption current type: 96 µA
ON
Minimum
Typical
Maximum
Ia
Standard type: 1,000 µA; Low consumption current type: 1,000 µA
Standard type: 1,250 µA; Low consumption current type: 1,200 µA
Standard type: 1,600 µA; Low consumption current type: 1,400 µA
Mask time*
Minimum
Typical
Maximum
Tm
0.8 s
1.3 s
1.8 s
Circuit stability time
Minimum
Typical
Maximum
Twu
15 s
30 s
45 s
When power is ON.
Timer time
Minimum
Typical
Maximum
Td
5s
10 s
15 s
Externally mounted
resistor R set to 0 kΩ
Rated
consumption
current
[Timing chart]
DETECTION PERFORMANCE
1. Standard sensitive type
TOP
TopVIEW
view
5m
16.404ft
SIDE
SideVIEW
view
5m
16.404ft
X
47°
Y
3m
9.843ft
Y
2
6.562
25.4°
2.5m
8.202ft
2.5m
8.202ft
1
3.281
28.7°
X-Y crross section
–4m
–3
–2
–1
–13.123ft –9.843 –6.562 –3.281
0
–1
–3.281
0°
0°
X
1
2
3
4m
3.281 6.562 9.843 13.123ft
–2
–6.562
–3m
–9.843ft
2.5m
8.202ft
5m
16.404ft
25.4°
47°
2.5m
8.202ft
–28.7°
5m
16.404ft
11
AMP series
2002.10.23 7:57 PM
Page 12
Motion-Detecting Sensor (AMP)
2. Highly sensitive type
Top view
Side view
X
Y
31.2°
1.5m
4.921ft
Y
31.2°
1.5m
4.921ft
1
3.281
1.5m
4.921ft
1
3.281
0.5
1.640
0.5
1.640
11.1°
0
1m
3.281ft
–0.5
–1.640
0°
2m
6.562ft
X-Y cross section
0
1m
3.281ft
–0.5
–1.640
–11.1°
–1
–3.281
0.5
1.640
11.1°
0°
2m
6.562ft
–1.5m –1
–0.5
0
–4.921ft –3.281 –1.640 –0.5
–1.640
–11.1°
0.5
1.640
1
1.5m
3.281 4.921ft
X
–1
–3.281
–1.5m
–4.921ft
–1.5m
–4.921ft
–31.2°
1m
3.281ft
–1.5m
–4.921ft
–31.2°
2m
6.562ft
1m
3.281ft
2m
6.562ft
HOW TO USE
1. Wiring diagram
Sensor module
Load power
source
2. Time setting
3. Installation
Standard sensitive type/Highly sensitive type
Timer time and external mounted resistor
Install the sensor so that people will be entering from the X or Y direction shown below. If
persons approch the sensor from the Z direction, detection distance will be shortened.
Timer time (Td)
R-value
10 sec.
30 sec.
1 min.
2 min.
3 min.
4 min.
5 min.
6 min.
8.86 KΩ
66.6 KΩ
153.2 KΩ
326.3 KΩ
499.5 KΩ
672.6 KΩ
845.8 KΩ
1,019 KΩ
Sensor power
source
External mounted
resistor
Short
68 KΩ
160 KΩ
330 KΩ
510 KΩ
680 KΩ
820 KΩ
1 MΩ
Note Timer time, 1 sec. is available as a custom
ordered product.
Time calculation:
Td = 0.3465×(20+R)
R: External mounted resistor (KΩ)
DIMENSIONS
mm inch
1. Standard sensitive type
2. Highly sensitive type
43.5
1.713 15.3
.602
43.5
1.713 18.3
.720
4-2.5 dia.
4-.098 dia.
22.5
.886
22.5
.886
20
.787
±0.3
18.4
.724
1.6
.063
26.8
1.055
3.4±0.3
.134±.012
35.8
1.409
28
1.102
49
1.929
24
.945
24
.945
16
.630
14.0 1.6 ±.012
.551 .063
35.8
1.409
4-2.5 dia.
4-.098 dia.
±0.3
3.4
.134±.012
28
1.102
49
1.929
General tolerance: ±0.4 ±.016
General tolerance: ±0.4 ±.016
18.3
25.6 .720
1.008
15.3
21.6.602
.850
43.5
1.713
4-2.5 dia.
4-.098 dia.
17.6
.693
11.25
.443
8.5
.335
12
43.5
1.713
R11.3
.445
22.5
.886
DataSheet4U.com
26.8
1.055
Note 1: In order to ensure proper detection, install it with
the lens exposed at least 8.5 mm .335 inch.
22.5
.886
4-2.5 dia.
4-.098 dia.
25.6
1.008
11.25
.443
R14.1
.555
7.0
.276
Note 2: In order to ensure proper detection, install it with
the lens exposed at least 7.0 mm .276 inch.
AMP series
2002.10.23 7:57 PM
Page 13
Motion-Detecting Sensor (AMP)
CAUTIONS WHEN USING
This product is mainly designed for use
indoors with general electronic devices.
If it is to be used outdoors, take suitable
precautions to protect it from water, dust,
dew condensation, and freezing.
Example:
1. Safety devices
2. Security equipment
3. Traffic signal equipment
4. Miscellaneous safety devices and
control equipment for trains,
automobiles.
1. Operation environment
1) Shown below are ambient temperature, humidity and air pressure conditions for operation, transportation, and
storage of the sensor.
a Usable ambient temperature:
–20 to 55°C –4 to +131°F
a Storage temperature:
–30 to 80°C –22 to +176°F
b Humidity: 15 to 85% R.H.
(with no freezing and condensation)
c Air pressure: 86 to 106 kPa
• Condensation
Condensation may occur if the relay
is exposed to sudden temperature
change in a high-temperature, highhumidity environment. This may
result in problems such as sensing
performance deterioration, nonoperation or insulation failure.
• Freezing
At temperature below 0°C 32°F, condensation and moisture may freeze
onto the sensor and cause problems
such as sensing performance
deterioration, non-operation or insulation failure.
12/1/2002
• Low-temperature, low-humidity
atmosphere
If the relay is exposed to a lowtemperature, low-humidity environment for an extended period of time,
the plastic components may become
brittle and fragile.
2) Be sure to use a stable power source
for the sensor. The sensor may operate
incorrectly if it receives voltage ripples of
more than 40 mV P-P.
3) Be sure to employ an absorber element to prevent the internal circuit from
being destroyed if an external voltage
surge of more than 500 V occurs (monopolarized all-wave voltage of ±1.2×50
µsec).
4) Static electricity or lightning may
cause the sensor to operate incorrectly.
5) Avoid using the sensor in the following
locations:
a Locations exposed to direct sunlight
or other bright light sources.
b Locations where a heater lies within
the detection range.
c Locations subject to direct air from an
air conditioner.
d Locations with high humidity (e.g.,
bathrooms, etc.).
e Locations subject to sudden, extreme
temperature changes.
f Locations subject to strong vibrations
or shocks.
g Locations containing objects that
block infra-red rays such as glass.
h Locations where blinds or curtains are
located near the detection range.
i Locations near to a heat source or
switching device.
j Locations containing dust or corrosive
gases.
k Outdoors.
2. Detection characteristics
1) Since this sensor works by detecting
fluctuations in infrared rays, it will also
detect non-human heat sources (e.g.,
small animals, etc.) if they enter the
detection range.
2) Since this sensor works by detecting
fluctuations in infra-red rays, it will not
detect a person that is motionless, even
if within the detection range.
3. Drop damage
If the sensor is dropped, damage can
occur resulting in incorrect operation. If
dropped, be sure to do a visual check of
the exterior for noticeable damage and
check the operation characteristics for
faulty operation.
4. Other handling cautions
1) When installing the sensor, be sure
not to apply stress to the printed circuit
board.
2) Be careful not to allow dust or dirt to
accumulate on the lens as this will adversely affect the detection sensitivity.
3) When soldering the lead wire, perform
the operation within 3 seconds at 350°C
662°F.
4) In order to avoid adverse effects from
noise, we recommend the use of
shielded wire when wiring.
5) In order to protect the internal circuitry, keep wire to a length of 1 m 3.3 ft
maximum from the sphere.
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog