AMP series 2002.10.23 7:57 PM Page 10 Motion-Detecting Sensor (AMP) MOTION-DETECTING SENSOR (PASSIVE INFRARED TYPE) AMP Series Highly sensitive type 24×24 mm .945×.945 inch • High detection ability This sensor is a stable, sensitive sensor that detects 2°C 3.6°F temperature changes regardless of the location or speed of the subject. In other words, this sensor ensures detection whether a person is at the edge of the detection area or in the middle, regardless of how fast they are moving. • Low current consumption The standard model consumes 260 µA (during stand-by), while the low consumption current type consumes 30 µA (during stand-by). This makes battery operation possible. • Wide operation voltage range (2.6 to 5.5 V DC) The usable range extends from a standard 5 V DC for microcomputers to 3 V DC and 4.5 V DC for battery operation. FEATURES • Detects even slight motion of a person (e.g. a 20 cm 7.87 inch movement of the hand) With our unique motion detector—highly sensitive type, even slight motions made by people will be detected easily. • Compact lens We have decreased the exposed portion of the lens, and at the same time maintained a detection ability that is as good or better than other motion sensors on the market. Lens dimensions: Standard sensitive type 16×20 mm .630×.787 inch ORDERING INFORMATION Detection performance 1: Standard sensitive type: 0.3 to 2.0 m/s 2: Highly sensitive type: 0.3 to 1.0 m/s Ex. AMP 0 Current consumption 0: Standard type 1: Low current consumption type • Varied operation in accordance with the surrouding brightness If used together with a brightness sensor (CdS), you can make the sensor operate only during bright hours or dark hours. • Output time can easily be changed By simply changing the resistor attached to the outside of the sensor, the output time can be changed from approximately 10 seconds to 6 minutes. TYPICAL APPLICATIONS • Lighting and ventilation control of conference rooms • Control of illumination and exhaust fans in toilets • Lighting control of halls • Nighttime lighting control of vending machines • Lightning control around cash dispensing machines (ATMs) 9 Lead wire 0: No lead wire type Operating voltage 9: 2.6 to 5.5 V DC TYPES Detection performance Current consumption Standard sensitive type Standard type Highly sensitive type Standard type Rated operating voltage Part No. Packing quantity Inner Outer 20 pcs. 200 pcs. AMP1009 Low current consumption type AMP1109 2.6 to 5.5 V DC AMP2009 AMP2109 Low current consumption type PERFORMANCE 1. Detection performance (Measuring conditions: ambient temp.: 25°C 77°F; operating voltage: 5V DC) Items Rated detection distance Detection range Standard sensitive type Highly sensitive type Conditions of objects to be detected 1. To have more than 2°C 36°F of temperature 1. difference from background 2. Movement speed • Standard sensitive type: 0.3 to 2.0 m/s • Highly sensitive type: 0.3 to 1.0 m/s 3. Detection object = human body 5 m min. 2 m min. Horizontal 95° 73° Vertical 55° 73° 34 zones 64 zones Detection zone 2. Absolute maximum rating (Measuring condition: ambient temp.: 25°C 77°F) Items Specified value Power supply voltage Output (Open collector) Voltage Current 7V 30 V 50 mA Usable ambient temperature –20 to +55°C –4 to +131°F Storage temperature –30 to +80°C –22 to +176°F 10 Remarks No freezing and condensing at low temperature. AMP series 2002.10.23 7:57 PM Page 11 Motion-Detecting Sensor (AMP) 3. Electrical characteristics (Measuring conditions: ambient temp.: 25°C 77°F; operating voltage: 5V) Items Symbol Specified value 2.6 V DC — 5.5 V DC Measured conditions Rated operating voltage Minimum Typical Maximum Vdd Standby Minimum Typical Maximum Iw Standard type: 200 µA; Low consumption current type: 12 µA Standard type: 260 µA; Low consumption current type: 30 µA Standard type: 560 µA; Low consumption current type: 96 µA ON Minimum Typical Maximum Ia Standard type: 1,000 µA; Low consumption current type: 1,000 µA Standard type: 1,250 µA; Low consumption current type: 1,200 µA Standard type: 1,600 µA; Low consumption current type: 1,400 µA Mask time* Minimum Typical Maximum Tm 0.8 s 1.3 s 1.8 s Circuit stability time Minimum Typical Maximum Twu 15 s 30 s 45 s When power is ON. Timer time Minimum Typical Maximum Td 5s 10 s 15 s Externally mounted resistor R set to 0 kΩ Rated consumption current [Timing chart] DETECTION PERFORMANCE 1. Standard sensitive type TOP TopVIEW view 5m 16.404ft SIDE SideVIEW view 5m 16.404ft X 47° Y 3m 9.843ft Y 2 6.562 25.4° 2.5m 8.202ft 2.5m 8.202ft 1 3.281 28.7° X-Y crross section –4m –3 –2 –1 –13.123ft –9.843 –6.562 –3.281 0 –1 –3.281 0° 0° X 1 2 3 4m 3.281 6.562 9.843 13.123ft –2 –6.562 –3m –9.843ft 2.5m 8.202ft 5m 16.404ft 25.4° 47° 2.5m 8.202ft –28.7° 5m 16.404ft 11 AMP series 2002.10.23 7:57 PM Page 12 Motion-Detecting Sensor (AMP) 2. Highly sensitive type Top view Side view X Y 31.2° 1.5m 4.921ft Y 31.2° 1.5m 4.921ft 1 3.281 1.5m 4.921ft 1 3.281 0.5 1.640 0.5 1.640 11.1° 0 1m 3.281ft –0.5 –1.640 0° 2m 6.562ft X-Y cross section 0 1m 3.281ft –0.5 –1.640 –11.1° –1 –3.281 0.5 1.640 11.1° 0° 2m 6.562ft –1.5m –1 –0.5 0 –4.921ft –3.281 –1.640 –0.5 –1.640 –11.1° 0.5 1.640 1 1.5m 3.281 4.921ft X –1 –3.281 –1.5m –4.921ft –1.5m –4.921ft –31.2° 1m 3.281ft –1.5m –4.921ft –31.2° 2m 6.562ft 1m 3.281ft 2m 6.562ft HOW TO USE 1. Wiring diagram Sensor module Load power source 2. Time setting 3. Installation Standard sensitive type/Highly sensitive type Timer time and external mounted resistor Install the sensor so that people will be entering from the X or Y direction shown below. If persons approch the sensor from the Z direction, detection distance will be shortened. Timer time (Td) R-value 10 sec. 30 sec. 1 min. 2 min. 3 min. 4 min. 5 min. 6 min. 8.86 KΩ 66.6 KΩ 153.2 KΩ 326.3 KΩ 499.5 KΩ 672.6 KΩ 845.8 KΩ 1,019 KΩ Sensor power source External mounted resistor Short 68 KΩ 160 KΩ 330 KΩ 510 KΩ 680 KΩ 820 KΩ 1 MΩ Note Timer time, 1 sec. is available as a custom ordered product. Time calculation: Td = 0.3465×(20+R) R: External mounted resistor (KΩ) DIMENSIONS mm inch 1. Standard sensitive type 2. Highly sensitive type 43.5 1.713 15.3 .602 43.5 1.713 18.3 .720 4-2.5 dia. 4-.098 dia. 22.5 .886 22.5 .886 20 .787 ±0.3 18.4 .724 1.6 .063 26.8 1.055 3.4±0.3 .134±.012 35.8 1.409 28 1.102 49 1.929 24 .945 24 .945 16 .630 14.0 1.6 ±.012 .551 .063 35.8 1.409 4-2.5 dia. 4-.098 dia. ±0.3 3.4 .134±.012 28 1.102 49 1.929 General tolerance: ±0.4 ±.016 General tolerance: ±0.4 ±.016 18.3 25.6 .720 1.008 15.3 21.6.602 .850 43.5 1.713 4-2.5 dia. 4-.098 dia. 17.6 .693 11.25 .443 8.5 .335 12 43.5 1.713 R11.3 .445 22.5 .886 DataSheet4U.com 26.8 1.055 Note 1: In order to ensure proper detection, install it with the lens exposed at least 8.5 mm .335 inch. 22.5 .886 4-2.5 dia. 4-.098 dia. 25.6 1.008 11.25 .443 R14.1 .555 7.0 .276 Note 2: In order to ensure proper detection, install it with the lens exposed at least 7.0 mm .276 inch. AMP series 2002.10.23 7:57 PM Page 13 Motion-Detecting Sensor (AMP) CAUTIONS WHEN USING This product is mainly designed for use indoors with general electronic devices. If it is to be used outdoors, take suitable precautions to protect it from water, dust, dew condensation, and freezing. Example: 1. Safety devices 2. Security equipment 3. Traffic signal equipment 4. Miscellaneous safety devices and control equipment for trains, automobiles. 1. Operation environment 1) Shown below are ambient temperature, humidity and air pressure conditions for operation, transportation, and storage of the sensor. a Usable ambient temperature: –20 to 55°C –4 to +131°F a Storage temperature: –30 to 80°C –22 to +176°F b Humidity: 15 to 85% R.H. (with no freezing and condensation) c Air pressure: 86 to 106 kPa • Condensation Condensation may occur if the relay is exposed to sudden temperature change in a high-temperature, highhumidity environment. This may result in problems such as sensing performance deterioration, nonoperation or insulation failure. • Freezing At temperature below 0°C 32°F, condensation and moisture may freeze onto the sensor and cause problems such as sensing performance deterioration, non-operation or insulation failure. 12/1/2002 • Low-temperature, low-humidity atmosphere If the relay is exposed to a lowtemperature, low-humidity environment for an extended period of time, the plastic components may become brittle and fragile. 2) Be sure to use a stable power source for the sensor. The sensor may operate incorrectly if it receives voltage ripples of more than 40 mV P-P. 3) Be sure to employ an absorber element to prevent the internal circuit from being destroyed if an external voltage surge of more than 500 V occurs (monopolarized all-wave voltage of ±1.2×50 µsec). 4) Static electricity or lightning may cause the sensor to operate incorrectly. 5) Avoid using the sensor in the following locations: a Locations exposed to direct sunlight or other bright light sources. b Locations where a heater lies within the detection range. c Locations subject to direct air from an air conditioner. d Locations with high humidity (e.g., bathrooms, etc.). e Locations subject to sudden, extreme temperature changes. f Locations subject to strong vibrations or shocks. g Locations containing objects that block infra-red rays such as glass. h Locations where blinds or curtains are located near the detection range. i Locations near to a heat source or switching device. j Locations containing dust or corrosive gases. k Outdoors. 2. Detection characteristics 1) Since this sensor works by detecting fluctuations in infrared rays, it will also detect non-human heat sources (e.g., small animals, etc.) if they enter the detection range. 2) Since this sensor works by detecting fluctuations in infra-red rays, it will not detect a person that is motionless, even if within the detection range. 3. Drop damage If the sensor is dropped, damage can occur resulting in incorrect operation. If dropped, be sure to do a visual check of the exterior for noticeable damage and check the operation characteristics for faulty operation. 4. Other handling cautions 1) When installing the sensor, be sure not to apply stress to the printed circuit board. 2) Be careful not to allow dust or dirt to accumulate on the lens as this will adversely affect the detection sensitivity. 3) When soldering the lead wire, perform the operation within 3 seconds at 350°C 662°F. 4) In order to avoid adverse effects from noise, we recommend the use of shielded wire when wiring. 5) In order to protect the internal circuitry, keep wire to a length of 1 m 3.3 ft maximum from the sphere. All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog