HONEYWELL-ACC SS49E-F

DESCRIPTION
The SS39ET/SS49E/SS59ET Series Low-cost Linear Halleffect sensors are small, versatile devices that are operated by
the magnetic field from a permanent magnet or an
electromagnet.
The linear sourcing output voltage is set by the supply voltage
and varies in proportion to the strength of the magnetic field.
Low voltage capability as low as 2.7 Vdc and reduced current
consumption of only 6 mA typically at 5 Vdc help make this
product energy efficient.
VALUE PROPOSITION

Designed and manufactured for cost competitiveness

All packages can be supplied on tape for automated,
lower-cost assembly

SS39ET’s small footprint takes up less space on the PC
board, typically allowing for more components
FEATURES AND BENEFITS
Miniature and subminiature construction: Designed for
compact designs with tight space requirements
Energy efficient: Low current consumption of 6 mA at
5 Vdc
Easy PC board interface: Single current sourcing output
for common electronic circuits
Circuit design flexibility: Voltage range of 2.7 Vdc to
6.5 Vdc
Low noise output: Virtually eliminates the need for filtering
Stable output: Thin film resistors improve accuracy
Wide range of environments: Temperature range of
-40 °C to 100 °C [-40 °F to 212 °F]
Application flexibility: Responds to either positive or
negative Gauss
The integrated circuitry features low noise output, which makes
it unnecessary to use external filtering. It also includes thin film
resistors to provide increased temperature stability and
accuracy. These linear Hall-effect sensors have an operating
temperature range of -40 C to 100 C [-40 F to 212 F],
appropriate for commercial, consumer, and industrial
environments.


Interfaces with many electrical components without
buffering
Thermally balanced integrated circuit for stable operation
over a full temperature range
POTENTIAL APPLICATIONS
Industrial:

Basic current sensing for motor load monitoring, detection

Anti-tampering magnetic field sensor in smart remote
utility meters

Pump control in heavy-duty equipment and household
appliances

Simple linear or angular displacement sensing

Handlebar/throttle position sensing in e-bikes and scooters

Current sensing in appliances

Speed adjustment trigger in tools and appliances

Magnetic code reading in safes, security and building
access control systems
Medical:

Position sensing in infusion pumps
Table 1. Operating Characteristics (VS = 5.0 V, TA = -40 °C to 85 °C [-40 °F to 185°F], except where noted)
Characteristic
Condition
Min.
Typ.
Max.
Output type
—
linear, sourcing
Magnetics type
—
analog
Supply voltage
—
2.7
—
6.5
Supply current
25 °C [77 °F]
—
6
10
Output voltage
—
1.0
1.4
1.75
Output current
Vs > 3.0 V
1.0
1.5
—
Null
0 Gauss, 25 °C
2.25
2.50
2.75
Output voltage span
—
1.05 to (Vs - 1.05)
0.95 to (Vs - 0.95)
—
Magnetic range
—
±650
±1000
—
Sensitivity
25 °C
1.0
1.4
1.75
Operating temperature
—
-40 [-40]
—
100 [212]
Temperature error
Null drift
—
-0.10
—
0.10
Sensitivity drift
≥25 °C
-0.15
—
0.05
<25 °C
-0.04
—
0.185
Linearity
—
—
-0.7
—
Response time
—
—
3
—
Table 2. Absolute Maximum Ratings
Characteristic
Supply voltage (Vs)
Output current
Storage temperature
Figure 1. Current Sourcing Output Block Diagram
Unit
—
—
Vdc
mA
mV/Gauss
mA
Vdc
Vdc
Gauss
mV/Gauss
°C [°F]
%/°C
% of span
µs
Parameter
-0.5 Vdc to 8.0 Vdc
10 mA
-55 C to 165 C [-67 F to 329 F]
Figure 2. Transfer Characteristics (VS = 5.0 Vdc)
NOTICE
Absolute maximum ratings are the extreme limits that the device will withstand without
damage to the device. However, the electrical and mechanical characteristics are not
guaranteed as the maximum limits (above recommended operating conditions) are
approached, nor will the device necessarily operate at absolute maximum ratings.
Figure 3. Null Shift versus Temperature
Figure 4. Sensitivity Shift versus Temperature
Figure 5. Typical Frequency Response
Figure 6. Supply Current versus Temperature
2,90
[0.114]
3
GND
(-)
2, 80
[0. 110]
NOMINAL
IC CENTER
1, 60
[0. 063]
1
VCC
(+)
2
OUTPUT
3X 0,50
[0.20]
0,95
[0.037]
1,90
[0.075]
NOMINAL
TO IC
SENSING
SURFACE
0,413
[0.016]
0,77
[0.030]
1,20
1,45 [0.047]
[0.057]
0,787
[0.031]
0,60
[0.024]
N
S
4,1
[0.16]
2,5
[0.10]
HALL
ELEMENT
CENTER
XXX
1,7
[0.07]
4,1
[0.16]
1,6
[0.06]
3,0
[0.12]
NS
2,5
[0.10]
HALL
1,7
ELEMENT [0.07]
CENTER
XXX
1,6
[0.06]
3,0
[0.12]
0,64
[0.025]
0,64
[0.025]
0,3
[0.015]
0,76
[0.03]
0,76
[0.03]
14,99
[0.59]
18,669
[0.735]
0,38
[0.015]
0,38
[0.015]
1,3 +
[0.05]
NS
–
0
1,3 +
[0.05]
4,1
[0.16]
2,5
[0.10]
HALL
ELEMENT
CENTER
1,6
[0.06]
XXX
3,0
[0.12]
1,7
[0.07]
NS
0,64
[0.025]
0,38
[0.015]
0,76
[0.03]
14,99
[0.59]
+
2,54
[0.10]
–
0
0,3
[0.015]
–
0
0,3
[0.015]
ADHESIVE TAPE
ADHESIVE TAPE
22,3
[0.88]
22,3
[0.88]
6,0
[0.23]
6,3
[0.25]
Ø 3,99
[0.16]
12,7
[0.50]
6,3
[0.25]
2,5
[0.10]
2,4
[0.09]
1,7
[0.07]
CATALOG
LISTING
DATE CODE
4,2
[0.16]
+
2X 1,5
[0.06]
1,3
[0.05]
0
4,5
[0.18]
3X 0,4
[0.02]
4,0
[0.16]
2,0
[0.08]
Ø 1,5
[0.06]
0,4 MAX
[0.02]
TOP COVER TAPE
0,7
[0.004]
5,5
[0.22] 12,0
[0.47]
2,0
[0.08]
8,0
[0.315]
Ø 13,0
[0.51]
N
S
0,13 MAX GATE VESTAGE
[0.005]
8,0
[0.31]
5,8
[0.230]
4,4
[0.17]
0,13 MAX FLASH
[0.005]
10 ° TYP
2,4 MAX
[0.9]
Ø 3,99
[0.16]
12,7
[0.50]
R 0,25 MAX
[0.01]
2,5
[0.10]
6,0
[0.23]
18,0
[0.71]
0,96 TYP TO HALL EFFECT
[0.38] SENSING SURFACE
0,1
[0.01]
0,05
[0.002]
9,0
[0.35]
3X 1,5
[0.06]
18,4
[0.72]
4,6
[0.18]
12,2
[0.48]
Ø 33,0
[1.30]
50,0
[1.97]
Ø 178,0
[7.01]
5,0
[0.20]
1,3
[0.05]
9,0
[0.35]
18,0
[0.71]
WARNING
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result
in death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result
in death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: [email protected]
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America
+1-305-805-8188
+1-305-883-8257 Fax
USA/Canada
+1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com/sensing
005850-2-EN
February 2012
© 2012 Honeywell International Inc. All rights reserved.