IXYS LDA200S

LDA200
Dual Optocouplers, Bidirectional Input
Single-Transistor Output
INTEGRATED CIRCUITS DIVISION
Parameter
Breakdown Voltage - BVCEO
Current Transfer Ratio - CTR (Typ)
Saturation Voltage - VCE(sat)
Input Control Current - IF
Rating
30
300
0.5
1
Units
VP
%
V
mA
Description
LDA200 is a dual optocoupler with bidirectional
inputs and single-transistor outputs. Current transfer
ratios range from 33% to 1000% with a typical value
of 300%.
Approvals
Features
•
•
•
•
•
•
100mA Continuous Load Rating
3750Vrms Input/Output Isolation
Bidirectional Input
8-Pin Package
Machine Insertable, Wave Solderable
Surface Mount Tape & Reel Packaging Available
Applications
•
•
•
•
•
•
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
Loop Detect
Ringing Detect
Current Sensing
• UL Recognized Component: File E76270
• CSA Certified Component: Certificate 1175739
• EN/IEC 60950-1 Certified Component:
TUV Certificate B 09 07 49410 006
Ordering Information
Part Number
LDA200
LDA200S
LDA200STR
Description
8-Pin DIP (50/tube)
8-Pin Surface Mount (50/tube)
8-Pin Surface Mount (1000/Reel)
Pin Configuration
A/K
A/K
1
8
2
7
3
6
4
5
Pb
DS-LDA200-R05
C
C
A/K
A/K
E
E
e3
www.ixysic.com
1
INTEGRATED CIRCUITS DIVISION
LDA200
Absolute Maximum Ratings @ 25ºC
Parameter
Breakdown Voltage
Input Control Current
Peak (10ms)
Power Dissipation
Input 1
Phototransistor 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1
Derate linearly 1.33mW / ºC
2
Derate linearly 2mW / ºC
Ratings
30
100
1
Units
VP
mA
A
150
150
3750
-40 to +85
-40 to +125
mW
mW
Vrms
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25ºC
Parameter
Output Characteristics
Phototransistor Breakdown Voltage
Phototransistor Dark Current
Saturation Voltage
Current Transfer Ratio
Output Capacitance
Input Characteristics
Input Control Current
Input Voltage Drop
Common Characteristics
Capacitance, Input to Output
Conditions
Symbol
Min
Typ
Max
Units
IC = 10µA
VCEO = 5V, IF = 0mA
IC = 2mA, IF = 1mA
IF = 1mA, VCE = 0.5V
25V, f =1MHz
BVCEO
ICEO
VCE(sat)
CTR
COUT
30
33
-
90
10
0.3
300
6
500
0.5
1000
-
V
nA
V
%
pF
IC = 0.33mA, VCE = 0.5V
IF = 5mA
IF
VF
0.9
1.2
1
1.4
mA
V
-
CI/O
-
3
-
pF
Switching Characteristics @ 25ºC
Characteristic
Turn-On Time
Turn-Off Time
Symbol
ton
toff
Test Condition
Typ
7
20
VCC=5V, IF=2mA, RL=1K
Units
s
Switching Time Test Circuit
VCC
Pulse Width=5ms
Duty Cycle=1%
IF
IF
RL
VCE
VCE
90%
10%
t on
2
www.ixysic.com
t off
R05
INTEGRATED CIRCUITS DIVISION
LDA200
PERFORMANCE DATA @25ºC (Unless Otherwise Noted)*
LED Voltage vs. Current (Linear)
20
10
0
1
1.2
1.3
1.4
1.5
LED Forward Voltage (V)
1.6
Typical CTR vs. LED Forward Current
(VCE=5V)
600
-40ºC
25ºC
55ºC
85ºC
500
400
1.0
300
200
1.1
1.2
1.3
1.4
1.5
LED Forward Voltage (V)
100
80
IF=20mA
60
IF=10mA
40
IF=5mA
20
60
0.14
0.12
0.10
1
2
3
4
Collector Voltage (V)
-20
0
20
40
60
Temperature (ºC)
80
100
5
80
IF=20mA
IF=15mA
60
IF=10mA
40
IF=5mA
IF=2mA
IF=1mA
20
0
6
-40
-20
0
20
40
60
80
Temperature (ºC)
100
120
Collector Leakage Current
vs. Temperature
500
96
95
94
93
92
91
90
89
400
VCE=10V
VCE=5V
VCE=3V
300
200
100
88
87
-20
0
20
40
60
Temperature (ºC)
14
80
100
-40
-20
20
40
60
Temperature (ºC)
Turn-On Time vs. Load Resistance
(VCC=5V)
IF=1mA
10
8
IF=2mA
6
4
IF=5mA
2
0
100
80
100
0
-40
-20
0
20
40
60
Temperature (ºC)
80
100
Turn-Off Time vs. Load Resistance
(VCC=5V)
10
12
Turn-On Time (Ps)
0
Turn-Off Time (ms)
0.08
-40
IF=5mA
IF=2mA
IF=1mA
Blocking Voltage vs. Temperature
Blocking Voltage (VP)
0.16
1.1
100
IF=2mA
IF=1mA
0
Saturation Voltage vs. Temperature
(IF=2mA, IC=1mA)
0.18
1.2
ICE Current vs. Temperature
(VCE=5V)
Leakage Current (nA)
20
30
40
50
LED Forward Current (mA)
1.3
1.0
-40
1.6
IF=50mA
0
10
1.4
Typical Collector Current vs.
Collector Voltage
100
0
IF=50mA
IF=20mA
IF=10mA
1.5
ICE Current (mA)
1.1
Collector Current (mA)
Current Transfer Ratio (%)
10
0.1
1.0
Saturation Voltage (V)
LED Forward Voltage (V)
LED Forward Current (mA)
LED Forward Current (mA)
30
0.20
1.6
100
40
700
LED Forward Voltage vs. Temperature
LED Voltage vs. Current (Log)
50
IF=2mA
IF=5mA
IF=1mA
8
6
4
2
0
1k
10k
100k
Load Resistance (:)
1M
0
100
200
300
400
Load Resistance (k:)
500
600
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please
contact our application department.
R05
www.ixysic.com
3
INTEGRATED CIRCUITS DIVISION
LDA200
Manufacturing Information
Moisture Sensitivity
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated
Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to
the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product
evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper
operation of our devices when handled according to the limitations and information in that standard as well as to any
limitations set forth in the information or standards referenced below.
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced
product performance, reduction of operable life, and/or reduction of overall reliability.
This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according
to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.
Device
Moisture Sensitivity Level (MSL) Rating
LDA200 / LDA200S
MSL 1
ESD Sensitivity
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.
Reflow Profile
This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020
must be observed.
Device
Maximum Temperature x Time
LDA200 / LDA200S
250ºC for 30 seconds
Board Wash
IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to
remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as
an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary
if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used.
Cleaning methods that employ ultrasonic energy should not be used.
Pb
4
e3
www.ixysic.com
R05
INTEGRATED CIRCUITS DIVISION
LDA200
Mechanical Dimensions
LDA200
2.540 ± 0.127
(0.100 ± 0.005)
9.652 ± 0.381
(0.380 ± 0.015)
8-0.800 DIA.
(8-0.031 DIA.)
2.540 ± 0.127
(0.100 ± 0.005)
9.144 ± 0.508
(0.360 ± 0.020)
6.350 ± 0.127
(0.250 ± 0.005)
Pin 1
PCB Hole Pattern
7.620 ± 0.254
(0.300 ± 0.010)
6.350 ± 0.127
(0.250 ± 0.005)
0.457 ± 0.076
(0.018 ± 0.003)
3.302 ± 0.051
(0.130 ± 0.002)
7.620 ± 0.127
(0.300 ± 0.005)
7.239 TYP.
(0.285)
4.064 TYP
(0.160)
0.254 ± 0.0127
(0.010 ± 0.0005)
7.620 ± 0.127
(0.300 ± 0.005)
Dimensions
mm
(inches)
0.813 ± 0.102
(0.032 ± 0.004)
LDA200S
9.652 ± 0.381
(0.380 ± 0.015)
2.540 ± 0.127
(0.100 ± 0.005)
6.350 ± 0.127
(0.250 ± 0.005)
Pin 1
0.635 ± 0.127
(0.025 ± 0.005)
3.302 ± 0.051
(0.130 ± 0.002)
9.525 ± 0.254
(0.375 ± 0.010)
0.457 ± 0.076
(0.018 ± 0.003)
PCB Land Pattern
2.54
(0.10)
8.90
(0.3503)
1.65
(0.0649)
7.620 ± 0.254
(0.300 ± 0.010)
0.254 ± 0.0127
(0.010 ± 0.0005)
0.65
(0.0255)
4.445 ± 0.127
(0.175 ± 0.005)
Dimensions
mm
(inches)
0.813 ± 0.102
(0.032 ± 0.004)
R05
www.ixysic.com
5
INTEGRATED CIRCUITS DIVISION
LDA200
LDA200STR Tape & Reel
330.2 DIA.
(13.00 DIA.)
Top Cover
Tape Thickness
0.102 MAX.
(0.004 MAX.)
K0 =4.90
(0.193)
K1 =4.20
(0.165)
Embossed Carrier
Embossment
W=16.00
(0.63)
Bo=10.30
(0.406)
Ao=10.30
(0.406)
P=12.00
(0.472)
User Direction of Feed
Dimensions
mm
(inches)
NOTES:
1. Dimensions carry tolerances of EIA Standard 481-2
2. Tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2
For additional information please visit our website at: www.ixysic.com
IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make
changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated
Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to
its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other
applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe
property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice.
6
Specification: DS-LDA200-R05
©Copyright 2012, IXYS Integrated Circuits Division
All rights reserved. Printed in USA.
12/22/2012