MICRODC WRE-ZD-6W

WRE-ZD-6W&WRF-ZD-6W Series
6W,4:1 WIDE INPUT,ISOLATED&REGULATED SINGLE/DUAL OUTPUT DIP DC/DC CONVERTER
SELECTION GUIDE
Input
Output
Voltage(VDC)
Order code
Voltage
(VDC)
Efficiency
(%,Typ)
Current(mA)
Nominal
Range
Max.*
Max.
Min.
WRE2405ZD-6W
24
9-36
40
±5
±600
±60
80
WRE2412ZD-6W
24
9-36
40
±12
±250
±25
82
WRE2415ZD-6W
24
9-36
40
±15
±200
±20
84
WRE2424ZD-6W
24
9-36
40
±24
±125
±13
87
WRF2403ZD-6W
24
9-36
40
3.3
1500
150
78
WRF2405ZD-6W
24
9-36
40
5
1200
120
80
WRF2412ZD-6W
24
9-36
40
12
500
50
82
WRF2415ZD-6W
24
9-36
40
15
400
40
84
◆Internal SMD construction
WRF2424ZD-6W
24
9-36
40
24
250
25
82
◆No Heat Sink Required
WRE4805ZD-6W
48
18-72
80
±5
±600
±60
80
WRE4812ZD-6W
48
18-72
80
±12
±250
±25
82
WRE4815ZD-6W
48
18-72
80
±15
±200
±20
84
◆MTBF>1,000,000 hours
WRE4824ZD-6W
48
18-72
80
±24
±125
±13
84
◆RoHS Compliance
WRF4803ZD-6W
48
18-72
80
3.3
1500
150
77
WRF4805ZD-6W
48
18-72
80
5
1200
120
80
WRF4812ZD-6W
48
18-72
80
12
500
50
82
WRF4815ZD-6W
48
18-72
80
15
400
40
84
WRF4824ZD-6W
48
18-72
80
24
250
25
84
FEATURES
◆High Efficiency up to 84%
◆Operating Temperature: -40℃ to +85℃
◆3KVDC Input/Output Isolation
◆Short Circuit Protection(Automatic recovery)
◆Industry Standard Pinout
MODEL SELECTION
①
②
③ ④
⑤
⑥
WRE 24 05 Z D -6W
①Product Series
③Output Voltage 1st
⑤Package Style
②Input Voltage
④Wide (4:1) Input Range
⑥Rated Power
Note:
1.*Input voltage can't exceed this value, or will cause the permanent damage.
2. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
3. Operation under 10% load will not damage the converter; However, they may not meet all specification
listed.
APPLICATIONS
The
WRE_ZD-6W&WRF_ZD-6W
Series
are
specially designed for applications where a wide
range input voltage power supplies are isolated from
the input power supply in a distributed power supply
system on a circuit board.
These products apply to:
1) Where the voltage of the input power supply is wide
ISOLATION SPECIFICATIONS
range (voltage range≤4:1);
2) Where isolation is necessary between input and
output (Isolation Voltage≤3000VDC);
Parameter
Test conditions
Min.
Typ.
Max.
Units
Output Power
See below products program
6
W
3) Where the regulation of the output voltage and the
Positive Voltage accuracy
Refer to recommended circuit
0.6
±1
±3
%
output ripple noise are demanded.
Negative Voltage accuracy
Refer to recommended circuit
±3
±5
%
Load Regulation
From 10% to 100% load
±0.5
±2*
%
Line Regulation(at full load)
Input voltage from low to high
±0.2
±0.5
Temperature Drift(Vout)
Refer to recommended circuit
±0.02
Ripple**
20MHz bandwidth
20
50
mVp-p
Noise**
20MHz bandwidth
75
150
mVp-p
Switching Frequency
100% load,nominal Input voltage
300
%
%/℃
KHz
*Dual output models unbalanced load: ±5%
**Test ripple and noise by “Parallel
cable”method. See detailed operation instructions at Testing of Power
Converter section, application notes.
MICRODC reserves the copyright
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 2
WRE-ZD-6W&WRF-ZD-6W Series
OUTPUT SPECIFICATIONS
Parameter
APPLICATION NOTE
Test conditions
Min
Typ.
Max
Unit
95
%
Requirement Output Load
In order to ensure the product operate efficiently and eliably, in addition
Storage Humidity
to a max load (namely full load), a minimum load is specified for this
Operating Temperature
-40
85
℃
Storage Temperature
-55
125
℃
is not exceeded, the minimum output load no less than 10% load. If
℃
the actual load is less than the specified minimum load, the output ripple
℃
may increase sharply while its efficiency and reliability will reduce
Temp. rise at full load
40
300
kind of DC/DC converter. Make sure the specified range of input voltage
Lead Temperature
1.5mm from case for 10 seconds
Isolation voltage
Tested for 1 minute and 1mA max
3000
VDC
greatly. If the actual output power is very small, please add an
Isolation resistance
Test at 500VDC
1000
MΩ
appropriate resistor as extra loading, or contact our company for other
No-load power consumption
500
Cooling
mW
Recommended Circuit
Free air convection
Case Material
All the WRE_ZD-6W & WRF_ZD-6W Series have been tested
Plastic(UL94-V0)
Short Circuit Protection
according to the following recommended
Continuous, automatic recovery
MTBF
1000
Weight
lower output power products.
testing circuit before
leaving factory. (See Figure 1).
K hours
17
g
TYPICAL CHARECTERISTICS
If you want to further decrease the input/output ripple, you can increase
capacitance properly or choose capacitors with low ESR. However, the
capacitance of the output filter capacitor must be proper. If the
capacitance is too big, a startup problem might arise. For every channel
of output, provided the safe and reliable operation is ensured, the
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
greatest capacitance of its filter capacitor sees (Table 1). General:
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT(TOP VIEW)
Cin:
24V&48V
10µF-47µF
Cout: 10µF/100mA
Input Current
When it is used in unregulated power supply, be sure that the fluctuating
range of the power supply and the rippled voltage do not exceed the
TUBE OUTLINE DIMENSIONS
module standard. Input current of power supply should afford the startup
current of this kind of DC/DC module (See figure 2), General:
Note:
Unit:mm[inch]
Pin diameter tolerances:±0.10mm[±0.004inch]
General tolerances: ±0.25mm[±0.010inch]
Ip ≤1.6*Iin-max
FOOTPRINT DETAILS
Pin
Single
Dual
2,3
GND
GND
9
No Pin
0V
11
NC
-Vo
14
+Vo
+Vo
16
0V
0V
22,23
Vin
Vin
NC: No connection.
http://www.microdc.cn
Note:
Unit :mm[inch]
General tolerances:±0.50mm[±0.020inch]
L=530mm[20.866inch]
Tube Quantity: 15pcs
L=220mm[8.661inch]
Tube Quantity: 6pcs
No parallel connection or plug and play.
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646