OKX-T/5-D12 Series www.murata-ps.com Adjustable 5-Amp SIP Non-Isolated DC/DC Converters FEATURES Non-isolated SIP PoL DC/DC power module 8.3-13.8Vdc input voltage range Programmable output voltage from 0.75255.5Vdc Under Voltage shutdown (Vin) Typical unit Drives 1000 μF ceramic capacitive loads High power conversion efficiency 93% at 5 Vout (typical) Outstanding thermal derating performance Over temperature and over current protection On/Off control UL60950, CSA-C22.2 No.60950 IEC/EN60950 (pending) Industry-standard (DOSA) SIP format RoHS-6 hazardous substance compliance PRODUCT OVERVIEW The OKX-T/5-D12 series are miniature SIP nonisolated Point-of-Load (POL) DC/DC power converters for embedded applications. The module is fully compatible with Distributed-power Open Standards Alliance industry-standard specifications. Applications include powering CPU’s, datacom/ telecom systems, programmable logic and mixed voltage systems. The wide input range is 8.3 to 13.8 Volts DC at 5 amps. Based on fixed-frequency synchronous buck converter switching topology, the high power conversion efficient Point of Load (PoL) module features programmable output voltage and On/Off control. These converters also include under voltage lock out (UVLO), output short circuit protection, over-current and over temperature protections. These units are designed to meet all standard UL/ EN/IEC 60950-1 safety certifications and RoHS-6 hazardous substance compliance. Connection Diagram +Vin F1 +Vout t4XJUDIJOH On/Off Control Controller t'JMUFST t$VSSFOU4FOTF External DC Power Source Trim Open = On Closed = Off (Positive On/Off) Reference and Error Amplifier Common Common Figure 1. OKX-T/5-D12 Note: Murata Power Solutions strongly recommends an external input fuse, F1. See specifications. For full details go to www.murata-ps.com/rohs (pending) www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 1 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE Output Model Number ➀ VOUT (Volts) ➀ IOUT (Amps, max) ➀ OKX-T/5-D12-C .7525-5.5 5 Input R/N Power (mVp-p) (Watts) Max. d 25 25 Regulation (Max.) Vin Nom. Range (Volts) (Volts) e Line Load ±0.2% ±0.5% 12 8.3-13.8 Efficiency Iin, no load (mA) Iin, full load (Amps) Min. Typ. Dimensions are in inches (mm) 45 2.24 91.5% 93.0% 0.40x0.90x0.282 (10.16x 22.86x 7.163) Case ➀ All specifications are at nominal line voltage, Vout=nominal (5V for D12 models) and full load, +25°C unless otherwise noted. d Ripple and Noise (R/N) is shown at Vout=1V. See specs for details. e The input voltage range must be 0.5V greater than the output voltage. PART NUMBER STRUCTURE OK X - T / 5 - D12 N - C Okami Non-isolated PoL RoHS Hazardous Substance Compliance C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder) SIP Mount Trimmable Output Voltage Range D12 Models = 0.7525-5.5V Maximum Rated Output Current in Amps On/Off Logic P = Positive Logic N = Negative Logic Input Voltage Range D12 = 8.3-13.8V Note: Some model number combinations may not be available. See Ordering Guide above. Contact Murata Power Solutions for availability. www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 2 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters FUNCTIONAL SPECIFICATIONS, OKX-T/5-D12-C Conditions ➀ Full power operation None, install external fuse Power on or off, referred to -Vin ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Input Reverse Polarity On/Off Remote Control Output Power Minimum 0 Typical/Nominal Maximum 15 None 0 0 25 13.8 25.5 Units Vdc Vdc Vdc W Current-limited, no damage, 0 5 A short-circuit protected Storage Temperature Range Vin = Zero (no power) -55 125 °C Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied or recommended. INPUT Conditions ➀ ➂ Operating voltage range Vin ≥ Vout +2 8.3 12 13.8 Vdc Recommended External Fuse Fast blow 6 A Turn On/Start-up threshold Rising input voltage, 0A load @1Vout 7.5 8.3 Vdc Turn Off/Undervoltage lockout 15 Falling input voltage, 0A load @1Vout 7.3 7.8 8.15 Vdc Reverse Polarity Protection None, install external fuse None Vdc Internal Filter Type C-TYPE Output Current Input current Full Load Conditions Low Line Inrush Transient Short Circuit Input Current No Load Input Current No Load Input Current Shut-Down Mode Input Current Reflected (back) ripple current ➁ Vin = nominal (5Vo set) Vin @ min, 5 Vout 2.24 3.204 2.322 3.321 5Vout, Iout @ 0 0.75V, Iout @ 0 45 20 5 20 75 35 Measured at input with specified filter A A A2-Sec. mA mA mA mA, pk-pk GENERAL and SAFETY Efficiency Safety @ Vin nom, 5Vout @ Vin min, 5Vout @ Vin nom, 3.3Vout @ Vin nom, 2.5Vout @Vin nom, 1.8Vout @Vin nom, 1.5Vout @Vin nom, 1.2Vout @Vin nom, 1Vout Certified to UL-60950-1, CSA-C22.2 No.60950-1, IEC/EN60950-1, 2nd edition 91.5 92.5 89 87 84 82 79 76 93 94 91 89 86 84 81 78 % % % % % % % % Yes (pending) Calculated MTBF ➃ Per Telcordia SR332, issue 1 class 3, ground fixed, Tambient=+25˚C Hours x 106 TBD DYNAMIC CHARACTERISTICS 290 Fixed Switching Frequency Startup Time Startup Time Dynamic Load Response Dynamic Load Peak Deviation Power On, to Vout regulation band, 100% resistive load Remote ON to 10% Vout (50% resistive load) 50-100-50% load step, settling time to within ±2% of Vout di/dt = 2.5 A/μSec same as above 320 350 KHz 8 10 mS 6 mS 80 μSec ±200 mV 0.4 +Vin V V mA +Vin 0.4 V V mA FEATURES and OPTIONS Remote On/Off Control ➄ “N” suffix: Negative Logic, ON state Negative Logic, OFF state Control Current “P” suffix: Positive Logic, ON state Positive Logic, OFF state Control Current Pin open=ON 0 1.5 open collector/drain Pin open=ON open collector/drain 1 7.8 0 1 www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 3 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters FUNCTIONAL SPECIFICATIONS, OKX-T/5-D12-C (CONT.) OUTPUT Total Output Power Voltage Nominal Output Voltage Range 13 Setting Accuracy Output Voltage Overshoot - Startup: Current Output Current Range Minimum Load Current Limit Inception ➅ Short Circuit Short Circuit Current ➆ Short Circuit Duration (remove short for recovery) Short circuit protection method Regulation ➉ Total Regulation Band Line Regulation Load Regulation Ripple and Noise ➇ Ripple and Noise Ripple and Noise Ripple and Noise Temperature Coefficient Maximum Capacitive Loading Maximum Capacitive Loading 14 Conditions ➀ Minimum 0 See trim formula At 50% load 0.7525 -2 0 98% of Vnom., after warmup @5Vout 9 Typical/Nominal 25 5 No minimum load 11.5 Hiccup technique, autorecovery within ±1% of Vout 2 Output shorted to ground, no damage Continuous Maximum 25.5 Units W 5.5 2 1 Vdc % of Vnom. %Vo nom 5 A 14.5 A A Current limiting Over all line, load and temp conditions Vin=min. to max. Vout=nom. Iout=min. to max. Vin=48V. 5Vo, 12Vin 3.3Vo, 12Vin 1.8Vo, 12Vin 1Vo, 12Vin At all outputs low ESR; >0.001, <0.01 ohm 0.01 ohm 2 ±0.02 1000 3000 % Vo set % % mV pk-pk mV pk-pk mV pk-pk mV pk-pk % of Vnom./°C uF μF 0.40x0.90x0.282 10.2x22.9x8.85 0.1 2.8 Inches mm Ounces Grams ±0.2 ±0.5 70 50 30 25 MECHANICAL (Through Hole Models) Outline Dimensions Weight ENVIRONMENTAL Operating Ambient Temperature Range ➈ Operating PCB Temperature 12 Storage Temperature Thermal Protection/Shutdown Electromagnetic Interference Conducted, EN55022/CISPR22 Radiated, EN55022/CISPR22 Full power, all output voltages, see derating curves No derating Vin = Zero (no power) Measured in center External filter is required -40 85 °C -40 -55 130 100 125 135 °C °C °C 130 B B Class Class Notes ➀ Specifications are typical at +25 deg.C, Vin=nominal (+12V.), Vout=nominal (+5V), full load, external caps and natural convection unless otherwise indicated. Extended tests at higher power must supply substantial forced airflow. All models are tested and specified with external 1 μF paralleled with 10 μF ceramic output capacitors and a 22 μF external input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate our test equipment and may not be required to achieve specified performance in your applications. However, Murata Power Solutions recommends installation of these capacitors. All models are stable and regulate within spec under no-load conditions. ➁ Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is Cin=2 x 100 μF tantalum, Cbus=1000 μF electrolytic, Lbus=1 μH. ➂ Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total RMS current over time does not exceed the Derating curve. ➇ Output noise may be further reduced by adding an external filter. At zero output current, the output may contain low frequency components which exceed the ripple specification. The output may be operated indefinitely with no load. ➈ All models are fully operational and meet published specifications, including “cold start” at –40°C. ➉ Regulation specifications describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme. 11 Other input or output voltage ranges will be reviewed under scheduled quantity special order. 12 Maximum PC board temperature is measured with the sensor in the center of the converter. 13 Do not exceed maximum power specifications when adjusting the output trim. 14 ➃ Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ISSUE 2, ground fixed controlled conditions, Tambient=+25 deg.C, full output load, natural air convection. ➄ The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to -Input Common. A logic gate may also be used by applying appropriate external voltages which not exceed +Vin. 15 ➅ Short circuit shutdown begins when the output voltage degrades approximately 1% from the selected setting. ➆ “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output. If the overcurrent condition still exists, the restart current will be removed and then tried again. This short current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter immediately recovers normal operation. 16 The maximum output capacitive loads depend on the the Equivalent Series Resistance (ESR) of the external output capacitor and, to a lesser extent, the distance and series impedance to the load. Larger caps will reduce output noise but may change the transient response. Newer ceramic caps with very low ESR may require lower capacitor values to avoid instability. Thoroughly test your capacitors in the application. Please refer to the Output Capacitive Load Application Note. Do not allow the input voltage to degrade lower than the input undervoltage shutdown voltage at all times. Otherwise, you risk having the converter turn off. The undervoltage shutdown is not latching and will attempt to recover when the input is brought back into normal operating range. The outputs are not intended to sink appreciable reverse current. www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 4 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters PERFORMANCE DATA, OKX-T/5-D12-C Efficiency vs. Line Voltage and Load Current @ +25°C (VOUT = 5V) Efficiency vs. Line Voltage and Load Current @ +25°C (VOUT = 3.3V) 96 94 94 92 90 92 88 VIN = 8.3V VIN = 12V VIN = 14V 86 Efficiency (%) Efficiency (%) 88 VIN = 8.3V VIN = 12V VIN = 14V 90 86 84 82 80 84 82 80 78 76 78 74 76 72 74 70 0 1 2 3 Load Curre nt (Amps) 4 5 0 6 Efficiency vs. Line Voltage and Load Current @ +25°C (VOUT = 2.5V) 94 92 92 90 90 88 3 Load Curre nt (Amps) 4 5 6 5 6 5 6 86 VIN = 8.3V VIN = 12V VIN = 14V 84 VIN = 8.3V VIN = 12V VIN = 14V 84 Efficiency (%) 86 Efficiency (%) 2 Efficiency vs. Line Voltage and Load Current @ +25°C (VOUT = 1.8V) 88 82 80 82 80 78 78 76 76 74 74 72 72 70 68 70 0 1 2 3 Load Curre nt (Amps) 4 5 0 6 1 2 3 4 Load Curre nt (Amps) Efficiency vs. Line Voltage and Load Current @ +25°C (VOUT = 1.5V) Efficiency vs. Line Voltage and Load Current @ +25°C (VOUT = 1.2V) 90 90 88 88 86 86 84 84 VIN = 8.3V VIN = 12V VIN = 14V 80 82 Efficiency (%) 82 Efficiency (%) 1 78 76 78 76 74 74 72 72 70 70 68 68 66 VIN = 8.3V VIN = 12V VIN = 14V 80 66 0 1 2 3 Load Curre nt (Amps) 4 5 6 0 1 2 3 Load Curre nt (Amps) 4 www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 5 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters PERFORMANCE DATA, OKX-T/5-D12-C Efficiency vs. Line Voltage and Load Current @ +25°C (VOUT = 1V) Maximum Current Temperature Derating at Sea Level (For Vin = 12.0V, Vout = 0.75 to 5V. Airflow is from pin 3 to pin 2.) 88 5.25 86 5.00 84 Natural convection 82 Output Current (Amps) 4.75 Efficiency (%) 80 VIN = 8.3V VIN = 12V VIN = 14V 78 76 74 72 70 68 4.50 4.25 4.00 3.75 3.50 66 3.25 64 62 0 1 2 3 Load Curre nt (Amps) 4 5 6 3.00 20 25 30 35 40 45 50 55 60 65 Ambient Temperature (ºC) 70 75 80 85 90 Step Load Transient Response (Vin=12V, Vout=5V, Cload = 1 uF || 10 uF) Top trace=Vout, Bottom trace=Iout 2.5A 5.0A 5.0A 2.5A 12Vin www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 6 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters PERFORMANCE DATA, OKX-T/5-D12-C Transient Response (Vout=3.3V, Cload= 1uF || 10uF) Top trace=Vout, Bottom trace=Iout 2.5A 5.0A 5.0A 2.5A 12Vin Step Load Transient Response (Vout=0.75V, Cload = 1 uF || 10 uF) Top trace=Vout, Bottom trace=Iout 2.5A 5.0A 5.0A 2.5A 12Vin www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 7 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters PERFORMANCE DATA, OKX-T/5-D12-C Output Ripple and Noise (Vin=12V, Cin=100uf, Cout= 1 uF || 10 uF, Ta=+25°C) 0A 5.0A 5.0Vout Output Ripple and Noise (Vin=12V, Cin=100uf, Cout= 1 uF || 10 uF, Ta=+25°C) 0A 5.0A 1.0Vout www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 8 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters PERFORMANCE DATA, OKX-T/5-D12-C Start-up Delay ( Vin=12V, Cin=100uF, Cload= 1uF || 10 uF, Ta=+25°C) 0A 5.0A 5.0Vout 3.3Vout 1.5Vout www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 9 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters PERFORMANCE DATA, OKX-T/5-D12-C On/Off Enable delay (Vin=12V, Cin=100uf, Cload= 1uF || 10uF, Ta=+25°C) 0A 5.0A 5.0Vout www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 10 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters MECHANICAL SPECIFICATIONS TOP VIEW 7.1 0.28 22.9 0.90 END VIEW FRONT VIEW 10.2 0.40 1.45 0.057 REF 1.3 0.05 0.34 REF 3.8 0.15 5 4 3 0.55 REF 2 2.54 0.100 TYP 0.025 TYP 20.32 0.800 1.3 0.05 5.8 0.23 0.64 0.025 Dimensions are in mm [inches] shown for ref. only. RECOMMENDED FOOTPRINT (VIEWED FROM TOP) [23.37] 0.92 [20.32] 0.800 [7.62] 0.30 5 4 Third Angle Projection [1.52] 0.06 3 2 1 [2.54] 0.100 [5.08] 0.200 [1.52] 0.06 [17.78] 0.700 [0.94] 0.037 (5 OR 6 PLS) ISOMETRIC VIEW (REF ONLY) Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 1˚ Components are shown for reference only. I/O CONNECTIONS Pin Function 1 +Vout 2 Trim 3 Gnd (Common) 4 +Vin 5 Remote On/Off *The Remote On/Off can be provided with either positive (P) or negative (N) logic. www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 11 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters STANDARD PACKAGING Each static dissipative polyethylene foam tray accommodates 75 converters 2.75±.25 (69.85) Closed height 11.00 ±.25 (279.4) 10.50±.25 (266.7) Carton accommodates four (4) trays of 75 yielding 300 converters per carton. Dimensions are in inches (mm shown for ref. only). Third Angle Projection Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 1˚ Components are shown for reference only. www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 12 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters TECHNICAL NOTES Input Fusing Certain applications and/or safety agencies may require fuses at the inputs of power conversion components. Fuses should also be used when there is the possibility of sustained input voltage reversal which is not current-limited. For greatest safety, we recommend a fast blow fuse installed in the ungrounded input supply line. The installer must observe all relevant safety standards and regulations. For safety agency approvals, install the converter in compliance with the end-user safety standard, i.e. IEC/EN/UL 60950-1. Input Under-Voltage Shutdown and Start-Up Threshold Under normal start-up conditions, converters will not begin to regulate properly until the ramping-up input voltage exceeds and remains at the Start-Up Threshold Voltage (see Specifications). Once operating, converters will not turn off until the input voltage drops below the Under-Voltage Shutdown Limit. Subsequent restart will not occur until the input voltage rises again above the Start-Up Threshold. This built-in hysteresis prevents any unstable on/off operation at a single input voltage. Users should be aware however of input sources near the Under-Voltage Shutdown whose voltage decays as input current is consumed (such as poorly regulated capacitor inputs), the converter shuts off and then restarts as the external capacitor recharges. Such situations could oscillate. To prevent this, make sure the operating input voltage is well above the UV Shutdown voltage AT ALL TIMES. Start-Up Time Assuming that the output current is set at the rated maximum, the Vin to Vout Start-Up Time (see Specifications) is the time interval between the point when the ramping input voltage crosses the Start-Up Threshold and the fully loaded regulated output voltage enters and remains within its specified regulation band. Actual measured times will vary with input source impedance, external input capacitance, input voltage slew rate and final value of the input voltage as it appears at the converter. These converters include a soft start circuit to moderate the duty cycle of its PWM controller at power up, thereby limiting the input inrush current. The On/Off Remote Control interval from On command to Vout regulated assumes that the converter already has its input voltage stabilized above the Start-Up Threshold before the On command. The interval is measured from the On command until the output enters and remains within its specified accuracy band. The specification assumes that the output is fully loaded at maximum rated current. Similar conditions apply to the On to Vout regulated specification such as external load capacitance and soft start circuitry. Recommended Input Filtering The user must assure that the input source has low AC impedance to provide dynamic stability and that the input supply has little or no inductive content, including long distributed wiring to a remote power supply. The converter will operate with no additional external capacitance if these conditions are met. For best performance, we recommend installing a low-ESR capacitor immediately adjacent to the converter’s input terminals. The capacitor should be a ceramic type such as the Murata GRM32 series or a polymer type. Initial suggested capacitor values are 10 to 22 μF, rated at twice the expected maxi- mum input voltage. Make sure that the input terminals do not go below the undervoltage shutdown voltage at all times. More input bulk capacitance may be added in parallel (either electrolytic or tantalum) if needed. Recommended Output Filtering The converter will achieve its rated output ripple and noise with no additional external capacitor. However, the user may install more external output capacitance to reduce the ripple even further or for improved dynamic response. Again, use low-ESR ceramic (Murata GRM32 series) or polymer capacitors. Initial values of 10 to 47 μF may be tried, either single or multiple capacitors in parallel. Mount these close to the converter. Measure the output ripple under your load conditions. Use only as much capacitance as required to achieve your ripple and noise objectives. Excessive capacitance can make step load recovery sluggish or possibly introduce instability. Do not exceed the maximum rated output capacitance listed in the specifications. Input Ripple Current and Output Noise All models in this converter series are tested and specified for input reflected ripple current and output noise using designated external input/output components, circuits and layout as shown in the figures below. The Cbus and Lbus components simulate a typical DC voltage bus. Please note that the values of Cin, Lbus and Cbus may vary according to the specific converter model. TO OSCILLOSCOPE CURRENT PROBE +INPUT VIN + – + – LBUS CBUS CIN -INPUT CIN = 2 x 100μF, ESR < 700mΩ @ 100kHz CBUS = 1000μF, ESR < 100mΩ @ 100kHz LBUS = 1μH Figure 2. Measuring Input Ripple Current Minimum Output Loading Requirements All models regulate within specification and are stable under no load to full load conditions. Operation under no load might however slightly increase output ripple and noise. Thermal Shutdown To prevent many over temperature problems and damage, these converters include thermal shutdown circuitry. If environmental conditions cause the temperature of the DC/DC’s to rise above the Operating Temperature Range up to the shutdown temperature, an on-board electronic temperature sensor will power down the unit. When the temperature decreases below the turn-on threshold, the converter will automatically restart. There is a small amount of temperature hysteresis to prevent rapid on/off cycling. www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 13 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters output voltage to begin ramping up to its appropriate value. If the short-circuit condition persists, another shutdown cycle will initiate. This rapid on/off cycling is called “hiccup mode”. The hiccup cycling reduces the average output current, thereby preventing excessive internal temperatures and/or component damage. A short circuit can be tolerated indefinitely. +SENSE +OUTPUT C1 C2 SCOPE RLOAD -OUTPUT C1 = 1μF C2 = 10μF LOAD 2-3 INCHES (51-76mm) FROM MODULE Figure 3. Measuring Output Ripple and Noise (PARD) CAUTION: If you operate too close to the thermal limits, the converter may shut down suddenly without warning. Be sure to thoroughly test your application to avoid unplanned thermal shutdown. Temperature Derating Curves The graphs in this data sheet illustrate typical operation under a variety of conditions. The Derating curves show the maximum continuous ambient air temperature and decreasing maximum output current which is acceptable under increasing forced airflow measured in Linear Feet per Minute (“LFM”). Note that these are AVERAGE measurements. The converter will accept brief increases in current or reduced airflow as long as the average is not exceeded. Note that the temperatures are of the ambient airflow, not the converter itself which is obviously running at higher temperature than the outside air. Also note that very low flow rates (below about 25 LFM) are similar to “natural convection,” that is, not using fan-forced airflow. Murata Power Solutions makes Characterization measurements in a closed cycle wind tunnel with calibrated airflow. We use both thermocouples and an infrared camera system to observe thermal performance. CAUTION: If you routinely or accidentally exceed these Derating guidelines, the converter may have an unplanned Over Temperature shut down. Also, these graphs are all collected at slightly above Sea Level altitude. Be sure to reduce the derating for higher density altitude. Output Current Limiting Current limiting inception is defined as the point at which full power falls below the rated tolerance. See the Performance/Functional Specifications. Note particularly that the output current may briefly rise above its rated value in normal operation as long as the average output power is not exceeded. This enhances reliability and continued operation of your application. If the output current is too high, the converter will enter the short circuit condition. Output Short Circuit Condition When a converter is in current-limit mode, the output voltage will drop as the output current demand increases. If the output voltage drops too low (approximately 98% of nominal output voltage for most models), the PWM controller will shut down. Following a time-out period, the PWM will restart, causing the Remote On/Off Control The remote On/Off Control can be ordered with either logic type. Please refer to the Connection Diagram on page 1 for On/Off connections. Positive logic models are enabled when the On/Off pin is left open or is pulled high to +Vin with respect to –Vin. Therefore, the On/Off control can be disconnected if the converter should always be on. Positive-logic devices are disabled when the On/Off is grounded or brought to within a low voltage (see Specifications) with respect to –Vin. Negative logic devices are on (enabled) when the On/Off pin is left open or brought to within a low voltage (see Specifications) with respect to –Vin. The device is off (disabled) when the On/Off is pulled high (see Specifications) with respect to –Vin. Dynamic control of the On/Off function must sink appropriate signal current when brought low and withstand appropriate voltage when brought high. Be aware too that there is a finite time in milliseconds (see Specifications) between the time of On/Off Control activation and stable, regulated output. This time will vary slightly with output load type and current and input conditions. Output Capacitive Load These converters do not require external capacitance added to achieve rated specifications. Users should only consider adding capacitance to reduce switching noise and/or to handle spike current load steps. Install only enough capacitance to achieve your noise and surge response objectives. Excess external capacitance may cause regulation problems and possible oscillation or instability. Proper wiring of the Sense inputs will improve these factors under capacitive load. The maximum rated output capacitance and ESR specification is given for a capacitor installed immediately adjacent to the converter. Any extended output wiring, smaller wire gauge or less ground plane may tolerate somewhat higher capacitance. Also, capacitors with higher ESR may use a larger capacitance. Pre-Biased Startup Some sections have external power already partially applied (possibly because of earlier power sequencing) before POL power up. Or leakage power is present so that the DC/DC converter must power up into an existing output voltage. This power may either be stored in an external bypass capacitor or supplied by an active source. These converters include a pre-bias startup mode to prevent initialization problems. This “pre-biased” condition can also occur with some types of programmable logic or because of blocking diode leakage or small currents passed through forward biased ESD diodes. This feature is variously called “monotonic” because the voltage does not decay or produce a negative transient once the input power is applied and startup begins. www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 14 of 15 OKX-T/5-D12 Series Adjustable 5-Amp SIP Non-Isolated DC/DC Converters Output Voltage Adustment The output voltage may be adjusted over a limited range by connecting an external trim resistor (Rtrim) between the Trim pin and Ground. The Rtrim resistor is recommended to have a ±0.5% accuracy (or better) with low temperature coefficient, ±100 ppm/°C or better. Mount the resistor close to the converter with very short leads or use a surface mount trim resistor. In the tables below, the calculated resistance is given. Do not exceed the specified limits of the output voltage or the converter’s maximum power rating when applying these resistors. Also, avoid high noise at the Trim input. However, to prevent instability, you should never connect any capacitors to Trim. OKX-T/5-D12 Output Voltage Calculated Rtrim (KΩ) 5.0 V. 1.472 3.3 V. 3.122 2.5 V. 5.009 2.0 V. 7.416 1.8 V. 9.024 1.5 V. 13.05 1.2 V. 22.46 1.0 V. 41.424 0.7525 V. ∞ (open) Resistor Trim Equation: 10500 RTRIM (:) = _____________ VOUT – 0.7525V –1000 Soldering Guidelines Product Label Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifications may cause damage to the product. Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers. Because of the small size of these products, the product label contains a character-reduced code to indicate the model number and manufacturing date code. Not all items on the label are always used. Please note that the label differs from the product photograph on page 1. Here is the layout of the label: Wave Solder Operations for through-hole mounted products (THMT) For Sn/Ag/Cu based solders: Maximum Preheat Temperature 115° C. Maximum Pot Temperature 270° C. Maximum Solder Dwell Time 7 seconds For Sn/Pb based solders: Maximum Preheat Temperature 105° C. Maximum Pot Temperature 250° C. Maximum Solder Dwell Time 6 seconds Mfg. date code X00016 Product code YMDX Rev. Revision level Figure 4. Label Artwork Layout The label contains three rows of information: First row – Murata Power Solutions logo Second row – Model number product code (see table) Third row – Manufacturing date code and revision level Model Number Product Code OKX-T/5-D12N-C X00105 OKX-T/5-D12P-C X01105 The manufacturing date code is four characters: First character – Last digit of manufacturing year, example 2009 Second character – Month code (1 through 9 and O through D) Third character – Day code (1 through 9 = 1 to 9, 10 = O and 11 through 31 = A through Z) Fourth character – Manufacturing information Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2012 Murata Power Solutions, Inc. www.murata-ps.com/support MDC_OKX-T/5-D12 Series.A01 Page 15 of 15