POWERDYNAMICS 42R04-2211

6
5
4
3
2
1
MATERIAL AND FINISH:
Insulator: Polycarbonate, UL-94V-0 rated
Contacts: IEC C14, 70°C: Brass, Nickel plated
IEC C16, 120°C: Bronze, Nickel plated
26
12.0+1.0
-0.5
ELECTRICAL SPECIFICATIONS:
Current rating: 10 A
Voltage rating: 250 VAC
D
N
D
ORDERING CODE:
42R04-__ 2 __ 1
1
2
C
L
26
1) ELECTRICAL CIRCUIT
CONFIGURATION
C
15.0+0.5
1 = IEC C14, 10A 250V 70°C
2+GROUND
V
D E
29.0-0.5
24.0+0.5
2 = IEC C16, 10A 250V 120°C
2+GROUND
2) COLOR
1 = BLACK
2 = GRAY
16.0+0.5
4.00
18.6
21.0-0.5
B
B
18 MIN.
PB
NOTES:
1. Contains integral cable clamp strain relief & internal screw
type connections. Maximum wire gauge is 16AWG stranded.
2. Recommended screw torque: 1.2Nm
3. Recommended strip length for jacket and conductors:
PB
PB
ADD C16 CONTACT MATERIAL
6/9/10
C
DF
PB
29.0 -0.5 WAS 28.2 +0.3
11/10/08
B
CHANGE
ADD NOTES 2 & 3; RoHS
1/25/07
A
DATE
REV
A
REVISIONS
CHNG CHCK APPR
14.0±0.2
23
N
G
L
31
5
TOLERANCE
UNLESS OTHERWISE SPECIFIED
X ± 1
X.X ± 0.4
X.XX ± 0.20
DRAWN
BY
CHECK
BY
APPR
BY
6.0 TYP.
6
55
4
GQ
DATE:
08/17/01
TD
DATE:
08/20/01
PB
DATE:
08/21/01
3
Phone: 973 560-0019
Whippany, New Jersey
Fax: 973 560-0076
PART: IEC 60320 C14 & C16 MALE POWER CORD
PLUG; R/A RIGHT HANDED CONNECTION
PART #:
SIZE:
SCALE:
SHEET
1 of 1
42R04-X2X1
A
NTS
2
ALL DIMENSIONS FOR REFERENCE ONLY
DIMENSIONS ARE IN MILLIMETERS
1
REV:
C