05050 TEL185B - TEL185E Only One Name Means ProTek’Tion™ TELEPHONE INTERFACE PROTECTOR Description The TEL185B/E is a two-stage transient voltage protector that provides primary and secondary protection against lightning, inductive switching and electrostatic discharge (ESD) transient threats. The first stage diverts the transient current through the ground terminal return path and the second stage clamps the voltage to a safe level without interruption of service. The TEL185B/E is designed to protect telcom lines from common mode (line-to-ground) transients. There are four (4) independent lines referenced to the ground terminals. TEL185B TEL185E Features applications • Compatible with IEC 61000-4-2 (ESD): Air - 15kV, Contact - 8kV • Compatible with IEC 61000-4-4 (EFT): 40A - 5/50ns • Compatible with IEC 61000-4-5 (Surge): 95A, 8/20µs, Level 4 (LineGnd) & 48A, Level 4 (Line-Line) • Designed for ±185 Volt (Peak) Telephone Lines • 4 Wire, Line-to-Ground Protection • Permanent Two-Stage Protection • Subnanosecond Response Time • Automatic Reset - Does Not Interrupt Service • Effective Against Lightning, Inductive Switching and ESD • Telcom Equipment Connected to Telcom Lines • Line Connected Modems and Fax Machines • Remote Telephone Extensions • Private Wire/Leased Phone Lines Mechanical characteristics • Approximate Weight: 28 grams (TEL185B) & 142 grams (TEL185E) • Flammability Rating UL 94V-0 05050.R5 10/12 Page 1 www.protekdevices.com 05050 TEL185B - TEL185E Only One Name Means ProTek’Tion™ typical device characteristics MAXIMUM RATINGS @ 25°C Unless Otherwise Specified PARAMETER SYMBOL VALUE UNITS VOP ±185 Volts Operating Line Current IO 200 mA Transient Voltage - 20 kV/Wire Transient Current - 8/20µs waveform - 10 kA/Wire Transient Current - 8/20µs waveform - 40 kA/Protector Operating Temperature TA -55 to 100 °C TSTG -55 to 100 °C - <1 ns Peak Operating Line Voltage Storage Temperature Response Time ELECTRICAL CHARACTERISTICS PER LINE @ 25°C Unless Otherwise Specified PART NUMBER TEL185B/E MAXIMUM LEAKAGE CURRENT maximum capacitance r ohms @ ±185vop ID µA @ 0v, 1mhz c pF 12 5 800 MAXIMUM CLAMPING VOLTAGE (8/20µs) maximum line throughput resistance @ ±500A VC volts 330 installation instructions There are five (5) terminals on both the line and equipment side of the TEL185E - four telcom line terminals and one ground terminal. The ground terminal, as shown on the label, is connected internally. A single ground connection is sufficient. However, it is recommended that both ground connections be used for a lower impedance path to earth. This connection can be made through the green AC power ground wire or a known earth ground. The ground wire should be #14 stranded wire. Incoming telcom lines are cut or disconnected from the equipment to insert the TEL185E product. The line side of the terminals are to be connected to outside telephone or telecommunication lines that carry the transient threats into the equipment to be protected. The equipment side of the terminals are to be connected to the equipment to be protected. The location of the product should be such that these wires are as short as possible. A #18 or 20 gauge wire can be used for these connections. The TEL185B requires an edge connector interface for installation. A standard 15 position edge connector can be used. When mounting or wiring the connectors onto a printed circuit board, be sure that the correct terminals are soldered. The line side of the board connections are finger contacts 2 thru 5. The boards are conformal coated for limited protection against moisture. ProTek’s telcom line protector is designed with a short circuit failure mode to give maximum protection. A fuse, PTC, fusible link, or circuit breaker is recommended for each signal line on the input (line) side of the protector for those applications that require an open circuit failure mode. Caution: A low DC resistance ground may not be indicative of a good lightning ground. Lightning contains a broad spectrum of frequencies - up to 1 MHz. A low impedance path to ground at the transient frequencies is necessary. A ground strap is recommended or a #6 AWG stranded wire. For wire lengths over 1.5 meters, there may be some excessive line to earth potential under severe thunderstorm conditions. For these applications, an additional protector may be necessary at the equipment interface. 05050.R5 10/12 Page 2 www.protekdevices.com 05050 TEL185B - TEL185E Only One Name Means ProTek’Tion™ package information TEL185B outline dimensions dim millimeters inches min max min max A - 12.7 - 0.50 B - 76.2 - 3.0 C - 48.2 - 1.90 D - 7.6 - 0.30 E - 17.8 - 0.7 Notes 1. I/O contacts spaced at 0.156” (3.96mm) centers. A B LINE EQUIPMENT D 05050.R5 10/12 C 14 4 3 15 2 13 ORIENTATION NOTCH 2 OUTPUT Connected to Transmit/Receive Circuits CONTINUITY INPUT OUTPUT 5 12 5 12 15 GND E Page 3 INPUT Connected to Line From Outside World www.protekdevices.com 05050 TEL185B - TEL185E Only One Name Means ProTek’Tion™ package information TEL185E outline dimensions dim millimeters inches min max min max A - 95.5 - 3.8 B 82.22 82.98 3.235 3.265 C - 57.2 - 2.25 D - 30.2 - 1.125 E - 15.5 - 0.61 F - 30.2 - 1.19 A B 3 3 4 WARNING 4 LINE GND EQUIPMENT GND 2 2 C D Terminal Strip 1 1 Adhesive Mylar Label Terminal Screw Mounting Hole for #8 Screw #6 Screws F E ORDERING INFORMATION base PART NUMBER MARKING TEL185B Logo, Date Code, Terminal Designations and Part Number TEL185E Logo, Date Code, Terminal Designations and Part Number 05050.R5 10/12 Page 4 www.protekdevices.com 05050 TEL185B - TEL185E Only One Name Means ProTek’Tion™ company information COMPANY PROFILE In business more than 20 years, ProTek Devices™ is a privately-held company located in Tempe, Arizona, that offers a product line of transient voltage suppressors (TVS); avalanche breakdown diodes; steering diode TVS arrays and other surge suppressor component products. These TVS devices protect electronic systems from the effects of lightning, electrostatic discharge (ESD), nuclear electromagnetic pulses (NEMP), inductive switching and EMI / RFI. ProTek Devices also offers high performance interface and linear products that include analog switches; multiplexers; LED drivers; audio control ICs; RF and related high frequency products. The analog devices work in a host of consumer; industrial; automotive and other applications. CONTACT US Corporate Headquarters 2929 South Fair Lane Tempe, Arizona 85282 USA By Telephone General: 602-431-8101 Sales: & Marketing: 602-414-5109 Customer Service: 602-414-5114 Product Technical Support: 602-414-5107 By Fax General: 602-431-2288 By E-mail: Sales: [email protected] Customer Service: [email protected] Technical Support: [email protected] ProTek Devices (Asia Pacific) Pte. Ltd. 8 Ubi Road 2, #06-19 Zervex Singapore - 408538 Tel: +65-67488312 Fax: +65-67488313 Web www.protekdevices.com COPYRIGHT © ProTek Devices 1998 - This literature is subject to all applicable copyright laws and is not for resale in any manner. SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice. DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering and technical assistance. ProTek assumes no responsibility with respect to the selection or specifications of such products. ProTek makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does ProTek assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability without limitation special, consequential or incidental damages. LIFE SUPPORT POLICY: ProTek Devices products are not authorized for use in life support systems without written consent from the factory. 05050.R5 10/12 Page 5 www.protekdevices.com