Electrical Specifications at 25OC
Parameter -- Single Hybrid
Impedance
R Load
PRI.
SEC.
Turns Ratio
T-31201
Units
600
1200
Ω
Ω
Package for Single Hybrid P/N T-31201
Dimensions in Inches (mm)
1.00
(25.4)
0.613 : 1
Direct Current in Pri. (DCI)
maximum
90
mA
PRI. + 10%
SEC. + 10%
80
197
Ω
Ω
max., ref. 1 kHz
4.5
dB
Return Loss
Typ., @ 1 kHz
25
dB
Longitudinal Balance
min., @ 1 kHz
60
dB
Frequency Response
300 Hz to 3.5 kHz
+ 0.50
dB
minimum
1250
VRMS
DC Resistance
Insertion Loss
Isolation
8
1
7
2
.200
(5.08)
1.69
(42.93)
MAX.
.750
(19.05)
TYP.
6
3
5
4
.250
(6.35)
3 PL.
1.39
(35.30)
MAX.
.150
(3.81)
TYP.
.680
(17.27)
Schematic for Dual Application: 2 each of P/N T-31202
2-Wire
Line
4-Wire
Transmit
Dual Configuration
4-Wire
Receive
ZL
R
e
1
Electrical Specifications at 25OC
Parameter -- Dual Hybrid *
Impedance
R Load
PRI.
SEC.
Turns Ratio
T-31202
Units
600
1200
Ω
Ω
e
2
L
Rg
Zo Balance
0.660 : 1
Direct Current in Pri. (DCI)
maximum
0
mA
PRI. + 10%
SEC. + 10%
58
82
Ω
Ω
3.85
dB
min., @ 1 kHz
25
dB
Longitudinal Balance
Longitudinal Balance
min., @ 200Hz to 1kHz
min., @ 1 kHz to 4 kHz
60
40
dB
dB
Frequency Response
300 Hz to 3.5 kHz
+ 0.50
dB
minimum
1500
VRMS
DC Resistance
Insertion Loss
max., ref. 1 kHz
Return Loss
Isolation
.785
(19.94)
.725
(18.42)
.187
(4.75)
TYP.
.042
(1.07)
TYP.
.187
(4.75)
TYP.
1
* Dual Applications require 2 each of P/N T-31202
Rhombus
Industries Inc.
2
3
Bottom View
6
Specifications subject to change without notice.
.620
(15.75)
5
4
For other values & Custom Designs, contact factory.
24
.016
(0.41)
.420
(10.67)
Package for Dual Hybrid
P/N T-31202
Dimensions in Inches (mm)
HYBRID - 11/98
15801 Chemical Lane, Huntington Beach, CA 92649-1595