ROITHNER RLT1550-40G

RLT1550-40G
TECHNICAL DATA
Infrared Laser Diode
Features
•
•
•
•
Lasing Mode Structure: Single mode
Peak Wavelength : typ. 1550 nm
Optical Ouput Power: 40 mW
Package: 9 mm
Electrical Connection
Pin Configuration
Bottom View
n-type
PIN
1
2
3
Function
LD Cathode
LD Anode, PD Cathode
PD Anode
Typical Characteristics
Characteristics
CW Output Power
Operating regime
Center Wavelength
FWHM Beam Divergence
Operating Voltage
Monitor Voltage
Operating Temperature
Package
Symbols
Pop
λC
θ║
θ┴
Uop
Um
Top
Values
40
CW
1550 +/- 10
8
45
<2
<5
25
9 mm
Unit
mW
nm
deg
deg
V
V
°C
Technical Parameters of stocked samples
Sample No.
1-V417
2-V417
3-V417
4-V417
6-V417
12-V417
14-V417
15-V417
16-V417
17-V417
04.08.2010
Threshold current Ith
[mA]
40
42
37
37
37
34
34
37
32
35
Operating current Iop
[mA]
189
192
184
193
189
163
164
171
170
171
rlt1550_40g.doc
Monitor current Im
[µA]
294
82
232
334
67
170
176
176
365
142
Peak wavelength
at Pop λop [nm]
1565
1567
1566
1566
1567
1563
1564
1567
1564
1565
1 of 3
Package Dimensons
9 mm Package (Unit:mm)
Intensity, a.u.
Typical beam divergence
θ_|_
θ||
-60
-40
-20
0
20
40
60
θ,deg.
04.08.2010
rlt1550_40g.doc
2 of 3
Safety of Laser light
•
Laser Light can damage the human eyes and skin. Do not expose the eye or
skin directly to any laser light and/or through optical lens. When handling the
LDs, wear appropriate safety glasses to prevent laser light, even any
reflections from entering to the eye. Focused laser beam through optical
instruments will increase the chance of eye hazard.
Cautions
1. Operating methode
• This LD shall change its forward voltage requirement and optical ouput power according to
temperature change. Also, the LD will require more operation current to maintain same
ouput power as it degrades. In order to maintain output power, use of APC (Automatic
Power Control) is recommended. Which use monitor feedback to adjust the operation
current.
• Confirm that electrical spike current generated by swithing on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handeling the product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated striclty below
absolute maximum rating.
04.08.2010
rlt1550_40g.doc
3 of 3