SECOS SCS706D

SCS706D
VOLTAGE 45V
SC-59 Types
0.03AMP Surface Mount Schottky Barrier Rectifiers
Elektronische Bauelemente
RoHS Compliant Product
A suffix of "-C" specifies halogen & lead-free
FEATURES
·
·
·
SC-59
Low Turn-on Voltage
A
Fast Switching
L
PN Junction Guard Ring for Transient and
ESD Protection
S
2
3
Top View
B
1
MECHANICAL DATA
·
·
·
·
·
D
Case: SOT-346, Molded Plastic
G
Terminals: Solderable per MIL-STD-202,
Method 208
J
C
Polarity: See Diagrams Below
Weight: 0.008 grams (approx.)
K
H
Mounting Position: Any
Dim
Min
Max
A
2.70
3.10
B
1.30
1.70
C
1.00
1.30
D
0.35
0.50
G
1.70
2.30
H
0.00
0.10
J
0.10
0.26
K
0.20
0.60
L
1.25
1.65
S
2.25
3.00
All Dimension in mm
3
2
1
CATHODE
ANODE
1
3
2
CATHODE
ANODE
SCS706D Marking : D3J
zAbsolute maximum ratings (Ta = 25°C)
Symbol
Limits
Unit
Peak reverse voltage
Parameter
VRM
45
V
DC reverse voltage
VR
40
V
Mean rectifying current
IO
30
mA
IFSM
200
mA
Peak forward surge current ∗
Junction temperature
Tj
125
°C
Storage temperature
Tstg
−40~+125
°C
∗60 Hz for 1
zElectrical characteristics (Ta = 25°C)
Parameter
Symbol
Min.
Typ.
Max.
Unit
Conditions
Forward voltage
VF
−
−
0.37
V
IF=1mA
Reverse current
IR
−
−
1
µA
VR=10V
Capacitance between terminals
CT
−
2.0
−
pF
VR=1V, f=1MHz
Note) ESD sensitive product handling required.
http://www.SeCoSGmbH.com
01-Jun-2002 Rev. A
Any changing of specification will not be informed individual
Page 1 of 2
SCS706D
Elektronische Bauelemente
VOLTAGE 45V
SC-59 Types
0.03AMP Surface Mount Schottky Barrier Rectifiers
RATING AND CHARACTERISTIC CURVES (SCS706D)
zElectrical characteristic curves (Ta = 25°C)
1000m
100µ
25
°C
10m
1m
Ta=−25°C
10µ
1µ
0
0.2
0.4
0.6
0.8
1.0
1.2
Ta=25°C
100n
Ta=−25°C
10n
1n
0
1.4
Typ.
pulse measurement
5
10
15
20
25
30
Fig. 1 Forward characteristics
Fig. 2 Reverse characteristics
35
f=1MHz
Ta=25°C
100
20
10
5
80
60
40
20
2
2
4
6
8
10
12
14
REVERSE VOLTAGE : VR (V)
Fig. 3 Capacitance between
terminals characteristics
01-Jun-2002 Rev. A
1µ
REVERSE VOLTAGE : VR (V)
50
http://www.SeCoSGmbH.com
Ta=75°C
FORWARD VOLTAGE : VF (V)
100
1
0
10µ
Io CURRENT (%)
CAPACITANCE BETWEEN TERMINALS : CT (pF)
Ta=75°C
Ta=25°C
100µ
Ta=125°C
REVERSE CURRENT : IR (A)
100m
Ta
=1
FORWARD CURRENT : IF (A)
Typ.
pulse measurement
0
25
50
75
100
125
AMBIENT TEMPERATURE : Ta(°C)
Fig 4. Derating curve
(mounting on glass epoxy PCBs)
Any changing of specification will not be informed individual