MINT1065D 65W Single Output Series Medical, 3rd Edition Certified Universal Input Power Supply 3 Year Warranty •65W Convection Cooled AC-DC Power Supply •Universal Input 90-264 VAC •Class I or Class II input versions •Less 0.5W No Load Power Dissipation •Rugged EMC Compliant Design •2” x 4” x 1.2” Package •ANSI AAMI ES/CSA/EN/IEC 60601-1, 3rd Edition Certified •Meets Efficiency Level IV Efficiency • Compliant (LVD, RoHS) •Optional Chassis/Cover Specifications RoHS All Specifications are typical at nominal input, full load at 25C unless otherwise stated. AC Input 100-240VAC +/- 10%, 47-63 Hz single phase. Input Current 115VAC: 0.7A, 230VAC: 1.5A. Inrush Current The inrush at 264VAC, at a cold start, will not exceed 40A. Input Fuses F1, F2: 2.5A, 250VAC fuses provided on all models. Efficiency Up to 90% typical. Earth Leakage Current <300μA @ 264Vac, 60Hz, normal; <500μA SFC. Touch Current is <100µA NC, <500µA SFC @ 264Vac, 60Hz, measured from output to ground Output Power 65W continuous. Ripple and Noise 1% pk-pk max., 20MHz BW, differential mode. Measured with noise probe directly across output terminals. Output Voltage See chart. Voltage Adjustability Voltage pre-set by fixed resistance. Minimum Load Not required. Total Regulation +/- 2%. See chart. Transient Response 500μs max., 50% load step, typical. Turn On Time Less than 1 second under all rated load conditions. Hold-up Time <17 ms at 65W, nominal input (120VAC). Overvoltage Protection Built-in Overload Protection Hiccup Mode Short Circuit Protection Hiccup Mode Isolation Input-Output: 4000Vac/2 MOOP Input-Ground: 1500Vac/1 MOOP Medical Safety Standards ANSI AAMI ES/CSA/EN/IEC 60601-1, 3rd Edition Switching Frequency Variable 50-75kHz typical. Operating Temperature 0 to 70C (derate from full rated power above 40C). Cooling Convection Output Power Derating See derating chart Storage Temperature -40 to +85C. Relative Humidity 5% to 95%, non-condensing ______________________________________________________________________________________________________________________________ 1 of 3 SL Power Electronics Corp 6050 King Drive Ventura, CA 93003 Phone 805.486.4565 Fax 858.712.2040 Email: [email protected] www.slpower.com MINT1065D 65W Single Output Series Medical 3rd Edition Certified Universal Input Power Supply 3 Year Warranty Output Parameters Model Number Volts (V) Output Current Open Frame w/cover Ripple & Noise Total Regulation OVP Threshold MINT1065D1275K01 12V 5.25A 4.00A 120mV ±2% 15.0 ± 1.5V MINT1065D1375K01 13.2V 4.80A 3.63A 140mV ±2% 16.0 ± 1.5V MINT1065D1575K01 15V 4.33A 3.20A 150mV ±2% 18.0 ± 1.5V MINT1065D1875K01 18V 3.50A 2.66A 180mV ±2% 21.0 ± 2.0V MINT1055D2075K01 20V 3.25A 2.40A 200mV ±2% 23.0 ± 2.0V MINT1065D2475K01 24V 2.70A 2.00A 240mV ±2% 27.0 ± 2.0V MINT1065D4875K01 48V 1.35A 1.00A 480mV ±2% 55.0 ± 4.0V Specifications (continued) Vibration Operating: 0.003 g2/Hz, 1.5 grms overall, 3 axes, 10 min. / axis Non-Operating: 0.026 g2/Hz, 5.0 grms overall, 3 axes, 1 hr. / axis Pollution Degree 2 Dimensions W 2.0” x L 4.0” x H 1.17”. See outline drawing. Weight 150 grams Shock Operating: Half-sine, 20 gpk, 10 ms, 3 axes, 6 shocks total Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total Overvoltage Category OVCII (2500V for Mains), OVCI (1500V for Secondary) Operating Altitude Up to 4000m. Non-operating Altitude -500 to 40,000 ft. EMI/EMC Compliance Conducted Emissions EN55011 Class B, FCC Part 15, Class B. Radiated Emissions EN55011 Class A, FCC Part 15, Class A. Static Discharge Immunity EN61000-4-2, 6kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m. EFT/Burst Immunity EN61000-4-4, 2kV/5kHz.. Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m Voltage Dip Immunity EN61000-4-11 240VAC, 0%/0.5 cycle, 40%/5cycles, 70%/25 cycles Model Number Key MINT 1 065 X 12 75 K 01 Model: Input Connector: Output Connector: Output Voltage: Configuration: Output Pow er: # of Outputs: Product Fam ily: "01" = Standard Model, 02 and higher indicates a m odified m odel. "K" = 3 pin Header (class I input); "C" = 2 pin Header (class II input). "75" = Output Connector, 4 pin header. Other options available, consult factory. "12" = 12V, "24" = 24V, etc. "D" = EN60601-1 3rd Edition Certified, "C" = Optional chassis & cover (class I only). "065" = 65W "1" = Single output "M" = Medical, "I" = Internal, "NT" = New Technology ______________________________________________________________________________________________________________________________ 2 of 3 SL Power Electronics Corp 6050 King Drive Ventura, CA 93003 Phone 805.486.4565 Fax 858.712.2040 Email: [email protected] www.slpower.com MINT1065D 65W Single Output Series Medical 3rd Edition Certified Universal Input Power Supply 3 Year Warranty Mechanical Drawings and Connector Information MINT1065 Series Connectors INPUT: J1 AMP P/N 641937-1 PIN 1) AC LINE PIN 2) AC NEUTRAL OUTPUT: J2 AMP P/N 640445-4 PIN 1) +Vout PIN 2) +Vout PIN 3) -Vout PIN 4) -Vout MATING CONNECTORS: P1 P2 Molex 09-50-3031 Molex 09-50-3041 Pins: Molex 08-50-0105 GND CONNECTION (Class I version) 0.187" FASTON TAB Output Power Derating Curve Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. Rev. 12-19-12 However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. ______________________________________________________________________________________________________________________________ 3 of 3 SL Power Electronics Corp 6050 King Drive Ventura, CA 93003 Phone 805.486.4565 Fax 858.712.2040 Email: [email protected] www.slpower.com