XPPOWER WF100_13

DCDC
2530 Watts
WF Series
xppower.com
•
2:1 Input Range
•
Efficiency to 85%
•
Input Pi Filter
•
Single, Dual & Triple Outputs
•
Remote On/Off
•
Sixsided Metal Case
•
External Output Trim
Specification
Input
Input Voltage Range
Input Current
Input Filter
Undervoltage Lockout
General
•
•
•
•
See table
See Table
Pi network
Turn On >70% nominal input
Turn Off <65% nominal input
Output
Initial Set Accuracy
Output Voltage
Adjustment
Minimum Load
Voltage Balance
Dual Output
Line Regulation
Efficiency
Isolation Voltage
Isolation Resistance
Switching Frequency
MTBF
•
•
•
•
•
See table
500 VDC min (3000 VDC for ‘U’ version)
109 ohms min
300 kHz typical
>800 kHrs to MIL-STD-217F
Environmental
• Single output models: ±2% max
Dual output models: ±2% max V1
±3% max V2
Triple output models: ±2% max V1
±5% max V2 & V3
• ±10% (except triple output models)
• Triple output models only
• ±1.0% max at full load
• ±0.5% max single & dual output models,
±1.0% max triple output models
Load Regulation
• ±1.0% max single & dual output models,
±5.0% max triple output models
Transient Response
• 5% max deviation, recovery to within
1% in 500 µs for a 25% step load change
Ripple & Noise
• 10 mV RMS max
75 mV pk-pk max, 20 MHz BW
Short Circuit Protection • Continuous, trip & restart (hiccup mode)
with auto recovery
Temperature
• 0.02%/˚C max
Coefficient
Remote On/Off
• On >5.5 VDC or open circuit
Off <1.8 VDC or short to Vin
Operating Temperature • -25 ˚C to +100 ˚C (see derating curve)
Storage Temperature • -40 ˚C to +100 ˚C
EMI/RFI
• Six-sided continuous shield
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
Conducted Immunity
Safety Approvals
• EN55022, level A Conducted
EN55022, level A Radiated
• EN61000-4-2, level 2
Perf Criteria A
• EN61000-4-3 3 V/m
Perf Criteria A
• EN61000-4-6 3 V rms
Perf Criteria A
• UL60950-1 for ‘U’ versions only
Input
Voltage
Output
Voltage
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
5.0/±12.0
5.0/±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
5.0/±12.0
5.0/±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
5.0/±12.0
5.0/±15.0
9-18 VDC
18-36 VDC
36-72 VDC
Output
Current
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
5.00
5.00
2.50
2.00
±2.50
±1.25
±1.00
3.50/±0.31
3.50/±0.25
5.00
5.00
2.50
2.00
±2.50
±1.25
±1.00
3.50/±0.31
3.50/±0.25
5.00
5.00
2.50
2.00
±2.50
±1.25
±1.00
3.50/±0.31
3.50/±0.25
No Load
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
30
30
30
30
35
35
35
35
35
30
30
30
30
30
30
30
30
30
20
20
20
20
25
25
25
25
25
Full Load
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
1.86
2.67
3.05
3.05
2.67
3.05
3.05
2.64
2.64
0.92
1.34
1.52
1.52
1.34
1.47
1.47
1.32
1.32
0.46
0.66
0.76
0.76
0.66
0.73
0.73
0.65
0.65
Efficiency
Model
Number(1)
74%
78%
82%
82%
78%
82%
82%
79%
79%
75%
79%
82%
82%
79%
85%
85%
80%
80%
75%
79%
82%
82%
79%
85%
85%
80%
80%
WF100
WF101
WF102
WF103
WF104
WF105
WF106
WF107
WF108
WF200
WF201
WF202
WF203
WF204
WF205
WF206
WF207
WF208
WF300
WF301
WF302
WF303
WF304
WF305
WF306
WF307
WF308
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Notes
1. For optional UL60950-1 approved product, add suffix ‘ U’ to model number.
Mechanical Details
All dimensions are in inches (mm)
Weight: 0.15 lbs (66 g) approx.
Case Material: Black coated copper with non-conductive base.
0.40
0.40
0.40
0.40
(10.16) (10.16) (10.16) (10.16)
8
7
6
5
1.80
(45.7)
BOTTOM VIEW
4
3
2
0.90
(22.9)
2.00
(50.8)
1
0.20
(5.1)
Single Output
PIN CONNECTIONS
Dual Output
Triple Output
1
2
3
4
5
6
7
8
Remote On/Off
No pin
-V input
+V input
Output trim
-Output
+Output
No pin
Remote On/Off
No pin
-V input
+V input
Output trim
-Output
Common
+Output
Remote On/Off
No pin
-V input
+V input
-Output
Common
+5V Output
+Output
Output
Pin No.
2.00 (50.8)
7
8&5
8&5
0.04 (1.02)
DIA
0.40
(10.2)
0.22
(5.6)
min
Pin
TRIPLE OUTPUT LOADING TABLE(1)
Current
Voltage
Minimum(2)
+5
+12 or -12
+15 or -15
0.50 A
0.10 A
0.10 A
Maximum
3.50 A
0.31 A
0.25 A
Notes
1. Maximum total power from all outputs is limited to 25 W but no output should be allowed to
exceed its maximum current.
2. Minimum current on each output is required to maintain specified regulation.
Application Notes
External Output Trimming
Derating Curve
100
Load (%)
80
PIN 7
60
10K
40
PIN 6
20
TRIM UP
0
-20 -10
0
10
20 30 40 50 60
Ambient Temperature (ºC)
70
80
90
100
TRIM
DOWN
TRIM
UP/DOWN
Output may optionally be externally
trimmed (±10%) with a fixed
resistor 10K or external trimpot
as shown
PIN 5
08-Apr-08
DCDC
WF Series
Models and Ratings