NSC LMP90079MH/NOPB

Sensor AFE System: Multi-Channel, Low-Power 16-Bit
Sensor AFE with True Continuous Background Calibration
1.0 General Description
The LMP90080/LMP90079/LMP90078/LMP90077 are highly
integrated, multi-channel, low-power 16-bit Sensor AFEs.
The devices feature a precision, 16-bit Sigma Delta Analogto-Digital Converter (ADC) with a low-noise programmable
gain amplifier and a fully differential high impedance analog
input multiplexer. A true continuous background calibration
feature allows calibration at all gains and output data rates
without interrupting the signal path. The background calibration feature essentially eliminates gain and offset errors
across temperature and time, providing measurement accuracy without sacrificing speed and power consumption.
Another feature of the LMP90080/LMP90079/LMP90078/
LMP90077 is continuous background sensor diagnostics, allowing the detection of open and short circuit conditions and
out-of-range signals, without requiring user intervention, resulting in enhanced system reliability.
Two sets of independent external reference voltage pins allow
multiple ratiometric measurements. In addition, two matched
programmable current sources are available in the
LMP90080/LMP90078 to excite external sensors such as resistive temperature detectors and bridge sensors. Furthermore, seven GPIO pins are provided for interfacing to external
LEDs and switches to simplify control across an isolation barrier.
Collectively, these features make the LMP90080/LMP90079/
LMP90078/LMP90077 complete analog front-ends for lowpower, precision sensor applications such as temperature,
pressure, strain gauge, and industrial process control. The
LMP90080/LMP90079/LMP90078/LMP90077 are guaranteed over the extended temperature range of -40°C to +125°
C and are available in a 28-pin TSSOP package.
2.0 Features
■ 16-Bit Low-Power Sigma Delta ADC
■ True Continuous Background Calibration at all gains
■ In-Place System Calibration using Expected Value
programming
■ Low-Noise programmable gain (1x - 128x)
■ Continuous background open/short and out of range
sensor diagnostics
■ 8 output data rates (ODR) with single-cycle settling
■ 2 matched excitation current sources from 100 µA to
■
■
■
■
■
■
■
■
■
1000 µA (LMP90080/LMP90078)
4-DIFF / 7-SE inputs (LMP90080/LMP90079)
2-DIFF / 4-SE inputs (LMP90078/LMP90077)
7 General Purpose Input/Output pins
Chopper-stabilized buffer for low offset
SPI 4/3-wire with CRC data link error detection
50 Hz to 60 Hz line rejection at ODR ≤13.42 SPS
Independent gain and ODR selection per channel
Supported by Webench Sensor AFE Designer
Automatic Channel Sequencer
3.0 Key Specifications
■ ENOB/NFR
Up to 16/16 bits
■ Offset Error (typ)
8.4 nV
■ Gain Error (typ)
7 ppm
■ Total Noise
< 10 µV-rms
■ Integral Non-Linearity (INL max)
■ Output Data Rates (ODR)
±1LSB
1.6775 SPS - 214.65 SPS
■ Analog Voltage, VA
+2.85V to +5.5V
■ Operating Temp Range
-40°C to 125°C
■ Package
28-Pin TSSOP
4.0 Applications
■ Temperature and Pressure Transmitters
■ Strain Gauge Interface
■ Industrial Process Control
5.0 Typical Application
30169774
TRI-STATE® is a registered trademark of National Semiconductor Corporation.
© 2011 National Semiconductor Corporation
301697
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077 Sensor AFE System: Multi-Channel, Low-Power 16Bit Sensor AFE with True Continuous Background Calibration
August 30, 2011
LMP90080/LMP90079/
LMP90078/LMP90077
LMP90080/LMP90079/LMP90078/LMP90077
6.0 Block Diagram
30169775
FIGURE 1. Block Diagram
bridge sensors. The LMP90080/LMP90079’s multiplexer supports 4 differential channels while the LMP90078/LMP90077
supports 2. Each effective input voltage that is digitized is VIN
= VINx – VINy, where x and y are any input. In addition, the
input multiplexer of the LMP90080/LMP90079 also supports
7 single-ended channels (LMP90078/LMP90077 supports 4),
where the common ground is any one of the inputs.
• True Continuous Background Calibration
The LMP90080/LMP90079/LMP90078/LMP90077 feature a
16 bit ΣΔ core with continuous background calibration to compensate for gain and offset errors in the ADC, virtually eliminating any drift with time and temperature. The calibration is
performed in the background without user or ADC input interruption, making it unique in the industry and eliminating
down time associated with field calibration required with other
solutions. Having this continuous calibration improves performance over the entire life span of the end product.
• Programmable Gain Amplifiers (FGA & PGA)
The LMP90080/LMP90079/LMP90078/LMP90077 contain
an internal 16x fixed gain amplifier (FGA) and a 1x, 2x, 4x, or
8x programmable gain amplifier (PGA). This allows accurate
gain settings of 1x, 2x, 4x, 8x, 16x, 32x, 64x, or 128x through
configuration of internal registers. Having an internal amplifier
eliminates the need for external amplifiers that are costly,
space consuming, and difficult to calibrate.
• Continuous Background Sensor Diagnostics
Sensor diagnostics are also performed in the background,
without interfering with signal path performance, allowing the
detection of sensor shorts, opens, and out-of-range signals,
which vastly improves system reliability. In addition, the fully
flexible input multiplexer described below allows any input pin
to be connected to any ADC input channel providing additional sensor path diagnostic capability.
• Excitation Current Sources (IB1 & IB2) - LMP90080/
LMP90078
Two matched internal excitation currents, IB1 and IB2, can be
used for sourcing currents to a variety of sensors. The current
range is from 100 µA to 1000 µA in steps of 100 µA.
• Flexible Input MUX Channels
The flexible input MUX allows interfacing to a wide range of
sensors such as thermocouples, RTDs, thermistors, and
www.national.com
2
1.0 General Description ......................................................................................................................... 1
2.0 Features ........................................................................................................................................ 1
3.0 Key Specifications ........................................................................................................................... 1
4.0 Applications .................................................................................................................................... 1
5.0 Typical Application ........................................................................................................................... 1
6.0 Block Diagram ................................................................................................................................ 2
7.0 Ordering Information ........................................................................................................................ 5
8.0 Connection Diagram ........................................................................................................................ 5
9.0 Pin Descriptions .............................................................................................................................. 6
10.0 Absolute Maximum Ratings ............................................................................................................. 7
11.0 Operating Ratings .......................................................................................................................... 7
12.0 Electrical Characteristics ................................................................................................................ 7
13.0 Timing Diagrams ......................................................................................................................... 12
14.0 Specific Definitions ...................................................................................................................... 15
15.0 Typical Performance Characteristics .............................................................................................. 16
16.0 Functional Description .................................................................................................................. 21
16.1 SIGNAL PATH ..................................................................................................................... 21
16.1.1 Reference Input (VREF) .............................................................................................. 21
16.1.2 Flexible Input MUX (VIN) ............................................................................................. 21
16.1.3 Selectable Gains (FGA & PGA) .................................................................................... 22
16.1.4 Buffer (BUFF) ............................................................................................................ 22
16.1.5 Internal/External CLK Selection .................................................................................... 22
16.1.6 Programmable ODRs .................................................................................................. 22
16.1.7 Digital Filter ............................................................................................................... 24
16.1.8 GPIO (D0–D6) ........................................................................................................... 27
16.2 CALIBRATION ..................................................................................................................... 27
16.2.1 Background Calibration ............................................................................................... 27
16.2.2 System Calibration ...................................................................................................... 28
FIGURE 15. Post-calibration Scaling Data-Flow Diagram ................................................... 29
16.3 CHANNELS SCAN MODE ..................................................................................................... 29
16.4 SENSOR INTERFACE .......................................................................................................... 30
16.4.1 IB1 & IB2 - Excitation Currents (LMP90080/LMP90078) ................................................... 30
16.4.2 Burnout Currents ........................................................................................................ 30
16.4.3 Sensor Diagnostic Flags .............................................................................................. 30
16.5 SERIAL DIGITAL INTERFACE ............................................................................................... 32
16.5.1 Register Address (ADDR) ............................................................................................ 32
16.5.2 Register Read/Write Protocol ....................................................................................... 32
16.5.3 Streaming .................................................................................................................. 32
16.5.4 CSB - Chip Select Bar ................................................................................................. 33
16.5.5 SPI Reset .................................................................................................................. 33
16.5.6 DRDYB - Data Ready Bar ............................................................................................ 33
16.5.7 Data Only Read Transaction ........................................................................................ 36
16.5.8 Cyclic Redundancy Check (CRC) ................................................................................. 37
16.6 POWER MANAGEMENT ...................................................................................................... 38
16.7 RESET and RESTART .......................................................................................................... 38
17.0 Applications Information ............................................................................................................... 39
17.1 QUICK START ..................................................................................................................... 39
17.2 CONNECTING THE SUPPLIES ............................................................................................. 39
17.2.1 VA and VIO ............................................................................................................... 39
17.2.2 VREF ........................................................................................................................ 39
17.3 ADC_DOUT CALCULATION .................................................................................................. 39
17.4 REGISTER READ/WRITE EXAMPLES ................................................................................... 40
17.4.1 Writing to Register Examples ....................................................................................... 40
17.4.2 Reading from Register Example ................................................................................... 41
17.5 STREAMING EXAMPLES ..................................................................................................... 42
17.5.1 Normal Streaming Example ......................................................................................... 42
17.5.2 Controlled Streaming Example ..................................................................................... 43
17.6 EXAMPLE APPLICATIONS ................................................................................................... 45
17.6.1 3–Wire RTD ............................................................................................................... 45
17.6.2 Thermocouple and IC Analog Temperature .................................................................... 47
18.0 Registers .................................................................................................................................... 48
18.1 REGISTER MAP .................................................................................................................. 48
18.2 POWER AND RESET REGISTERS ........................................................................................ 49
18.3 ADC REGISTERS ................................................................................................................ 51
3
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
Table of Contents
LMP90080/LMP90079/LMP90078/LMP90077
18.4 CHANNEL CONFIGURATION REGISTERS ............................................................................
18.5 CALIBRATION REGISTERS ..................................................................................................
18.6 SENSOR DIAGNOSTIC REGISTERS .....................................................................................
18.7 SPI REGISTERS ..................................................................................................................
18.8 GPIO REGISTERS ...............................................................................................................
19.0 Physical Dimensions ....................................................................................................................
52
56
57
58
60
61
List of Figures
FIGURE 1. Block Diagram ......................................................................................................................... 2
FIGURE 2. Timing Diagram ...................................................................................................................... 12
FIGURE 3. Simplified VIN Circuitry .............................................................................................................. 21
FIGURE 4. CLK Register Settings ............................................................................................................... 22
FIGURE 5. Digital Filter Response, 1.6775 SPS and 3.355 SPS .......................................................................... 24
FIGURE 6. Digital Filter Response, 6.71 SPS and 13.42 SPS .............................................................................. 24
FIGURE 7. Digital Filter Response at 13.42 SPS ............................................................................................. 25
FIGURE 8. Digital Filter Response, 26.83125 SPS and 53.6625 SPS .................................................................... 25
FIGURE 9. Digital Filter Response 107.325 SPS and 214.65 SPS ........................................................................ 26
FIGURE 10. Digital Filter Response for a 3.5717MHz versus 3.6864 MHz XTAL ...................................................... 26
FIGURE 11. GPIO Register Settings ............................................................................................................ 27
FIGURE 12. Types of Calibration ................................................................................................................ 27
FIGURE 13. BgcalMode2 Register Settings ................................................................................................... 28
FIGURE 14. System Calibration Data-Flow Diagram ......................................................................................... 28
FIGURE 15. Post-calibration Scaling Data-Flow Diagram ................................................................................... 29
FIGURE 16. Burnout Currents .................................................................................................................... 30
FIGURE 17. Burnout Currents Injection for ScanMode3 ..................................................................................... 30
FIGURE 18. Sensor Diagnostic Flags Diagram ............................................................................................... 31
FIGURE 19. Register Read/Write Protocol ..................................................................................................... 32
FIGURE 20. DRDYB Behavior .................................................................................................................... 33
FIGURE 21. DRDYB Behavior for an Incomplete ADC_DOUT Reading .................................................................. 33
FIGURE 22. DrdybCase1 Connection Diagram ............................................................................................... 34
FIGURE 23. Timing Protocol for DrdybCase1 ................................................................................................. 34
FIGURE 24. Timing Protocol for DrdybCase2 ................................................................................................. 35
FIGURE 25. DrdybCase3 Connection Diagram ............................................................................................... 36
FIGURE 26. Timing Protocol for DrdybCase3 ................................................................................................. 36
FIGURE 27. Timing Protocol for Reading SPI_CRC_DAT .................................................................................. 37
FIGURE 28. Timing Protocol for Reading SPI_CRC_DAT beyond normal DRDYB deassertion at every 1/ODR seconds ...... 37
FIGURE 29. Active, Power-Down, Stand-by State Diagram ................................................................................ 38
FIGURE 30. ADC_DOUT vs. VIN of a 16-Bit Resolution (VREF = 5.5V, Gain = 1). .................................................... 39
FIGURE 31. Register-Write Example 1 ......................................................................................................... 40
FIGURE 32. Register-Write Example 2 ......................................................................................................... 40
FIGURE 33. Register-Read Example ........................................................................................................... 41
FIGURE 34. Normal Streaming Example ....................................................................................................... 42
FIGURE 35. Setting up SPI_STREAMCN ...................................................................................................... 43
FIGURE 36. Controlled Streaming Example ................................................................................................... 44
FIGURE 37. Topology #1: 3-wire RTD Using 2 Current Sources ........................................................................... 45
FIGURE 38. Topology #2: 3-wire RTD Using 1 Current Source ............................................................................ 46
FIGURE 39. Thermocouple with CJC ........................................................................................................... 47
List of Tables
TABLE 1. ENOB (Noise Free Resolution) vs. Sampling Rate and Gain at VA = VIO = VREF = 3V .................................
TABLE 2. RMS Noise (µV) vs. Sampling Rate and Gain at VA = VIO = VREF = 3V ....................................................
TABLE 3. ENOB (Noise Free Resolution) vs. Sampling Rate and Gain at VA = VIO = VREF = 5V ..................................
TABLE 4. RMS Noise (µV) vs. Sampling Rate and Gain at VA = VIO = VREF = 5V ....................................................
TABLE 5. Data First Mode Transactions ........................................................................................................
www.national.com
4
11
11
11
11
36
LMP90080/LMP90079/LMP90078/LMP90077
7.0 Ordering Information
Product
Channel Configuration
Current Sources
LMP90080
4 Differential / 7 Single-Ended
Yes
LMP90079
4 Differential / 7 Single-Ended
No
LMP90078
2 Differential / 4 Single-Ended
Yes
LMP90077
2 Differential / 4 Single-Ended
No
Order Code
Temperature Range
Description
LMP90080MH/NOPB
−40°C to +125°C
28-Lead TSSOP Package, Rail of 48
LMP90080MHE/NOPB
−40°C to +125°C
28-Lead TSSOP Package, Reel of 250
LMP90080MHX/NOPB
−40°C to +125°C
28-Lead TSSOP Package, Reel of 2500
LMP90079MH/NOPB
−40°C to +125°C
28-Lead TSSOP Package, Rail of 48
LMP90079MHE/NOPB
−40°C to +125°C
28-Lead TSSOP Package, Reel of 250
LMP90079MHX/NOPB
−40°C to +125°C
28-Lead TSSOP Package, Reel of 2500
LMP90078MH/NOPB
−40°C to +125°C
28-Lead TSSOP Package, Rail of 48
LMP90078MHE/NOPB
−40°C to +125°C
28-Lead TSSOP Package, Reel of 250
LMP90078MHX/NOPB
−40°C to +125°C
28-Lead TSSOP Package, Reel of 2500
LMP90077MH/NOPB
−40°C to +125°C
28-Lead TSSOP Package, Rail of 48
LMP90077MHE/NOPB
−40°C to +125°C
28-Lead TSSOP Package, Reel of 250
LMP90077MHX/NOPB
−40°C to +125°C
28-Lead TSSOP Package, Reel of 2500
8.0 Connection Diagram
30169776
See Pin Descriptions for specific information regarding options LMP90079, LMP90078, and LMP90077.
5
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
9.0 Pin Descriptions
Pin #
Pin Name
Type
1
VA
Analog Supply
Function
2-4
VIN0 - VIN2
Analog Input
Analog input pins
5-7
(LMP90080,
LMP90079)
VIN3 - VIN5
Analog Input
Analog input pins
5-7
(LMP90078,
LMP90077)
VIN3 - VIN5
No Connect
No connect: must be left unconnected
8
VREFP1
Analog Input
Positive reference input
9
VREFN1
Analog Input
Negative reference input
10
VIN6 / VREFP2
Analog Input
Analog input pin or VREFP2 input
Analog power supply pin
11
VIN7 / VREFN2
Analog Input
Analog input pin or VREFN2 input
12 - 13
(LMP90080,
LMP90078)
IB2 & IB1
Analog output
Excitation current sources for external RTDs
12 - 13
(LMP90080,
LMP90078)
IB2 & IB1
No Connect
14
XOUT
Analog output
15
XIN / CLK
Analog input
16
GND
Ground
17
CSB
Digital Input
Chip select bar
18
SCLK
Digital Input
Serial clock
19
SDI
Digital Input
Serial data input
No connect: must be left unconnected
External crystal oscillator connection
External crystal oscillator connection or external
clock input
Power supply ground
20
SDO / DRDYB
Digital Output
21 - 26
D0 - D5
Digital IO
General purpose input/output (GPIO) pins
27
D6 / DRDYB
Digital IO
General purpose input/output pin or data ready bar
28
VIO
Digital Supply
www.national.com
6
Serial data output and data ready bar
Digtal input/output supply pin
1, Note 2)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Analog Supply Voltage, VA
Digital I/O Supply Voltage, VIO
Reference Voltage, VREF
Voltage on Any Analog Input Pin to
GND (Note 3)
Voltage on Any Digital Input PIN to
GND (Note 3)
Voltage on SDO (Note 3)
Input Current at Any Pin (Note 3)
Output Current Source or Sink by SDO
Total Package Input and Output
Current
ESD Susceptibility
Human Body Model (HBM)
-0.3V to 6.0V
-0.3V to 6.0V
-0.3V to VA+0.3V
-0.3V to VA+0.3V
11.0 Operating Ratings
Analog Supply Voltage, VA
Digital I/O Supply Voltage, VIO
Full Scale Input Range, VIN
Reference Voltage, VREF
-0.3V to VIO+0.3V
-0.3V to VIO + 0.3V
5mA
3mA
+2.85V to 5.5V
+2.7V to 5.5V
±VREF / PGA
+0.5V to VA
TMIN = –40°C
TMAX = +125°C
Temperature Range for Electrical
Characteristics
Operating Temperature Range
20mA
–40°C ≤ TA ≤ +125°C
Junction to Ambient Thermal
Resistance (θJA) (Note 4)
2500V
41°C/W
12.0 Electrical Characteristics
Unless otherwise noted, the key for the condition is (VA = VIO = VREF) / ODR (SPS) / buffer / calibration / gain . Boldface limits
apply for TMIN ≤ TA ≤ TMAX; the typical values apply for TA = +25°C.
Symbol
n
ENOB /
NFR
ODR
INL
Parameter
Conditions
Min
Resolution
Effective Number
of Bits and Noise
Free Resolution
Max
16
Bits
Table 1
Bits
5V / all / ON / OFF / all. Shorted input.
Table 3
Bits
1.6675
Table 1
214.6
Gain
FGA × PGA
1
Table 1
128
Integral NonLinearity
3V / 214.65 / ON / ON / 1
-1
± 0.5
+1
3V & 5V / 214.65 / ON / ON / 16
3V / all / ON / ON / all. Shorted input.
5V / all / ON / OFF / all. Shorted input.
3V & 5V / all / ON or OFF / ON / all
Offset Error
3V / 214.65 / ON / ON / 1
3V / 214.65 / ON / ON / 128
5V / 214.65 / ON / ON / 1
5V / 214.65 / ON / ON / 128
3V & 5V / 214.65 / ON or OFF / OFF /
1-8
Offset Drift Over
Temp (Note 5)
Offset Drift over
Time (Note 5)
Units
3V / all / ON / OFF / all. Shorted input.
Output Data Rates
Total Noise
OE
Typ
SPS
LSB
±1
LSB
Table 2
µV
Table 4
µV
Below Noise
Floor (rms)
µV
1.22
9.52
µV
0.00838
0.70
µV
1.79
8.25
µV
0.0112
0.63
µV
100
nV/°C
3V & 5V / 214.65 / ON / ON / 1-8
3
nV/°C
3V & 5V / 214.65 / ON / OFF / 16
25
nV/°C
3V & 5V / 214.65 / ON / ON / 16
0.4
nV/°C
3V & 5V / 214.65 / ON / OFF / 128
6
nV/°C
3V & 5V / 214.65 / ON / ON / 128
0.125
nV/°C
5V / 214.65 / ON / OFF / 1, TA = 150°C
2360
nV /
1000 hours
5V / 214.65 / ON / ON / 1, TA = 150°C
100
nV /
1000 hours
7
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
Machine Models (MM)
200V
Charged Device Model (CDM)
1250V
Junction Temperature (TJMAX)
+150°C
Storage Temperature Range
–65°C to +150°C
For soldering specifications:
see product folder at www.national.com and
www.national.com/ms/MS/MS-SOLDERING.pdf
10.0 Absolute Maximum Ratings (Note
LMP90080/LMP90079/LMP90078/LMP90077
Symbol
Parameter
Conditions
Min
3V & 5V / 214.65 / ON / ON / 1
GE
Gain Error
Gain Drift over
Temp (Note 5)
Gain Drift over
Time (Note 5)
-80
Typ
Max
Units
7
80
ppm
3V & 5V / 13.42 / ON / ON / 16
50
ppm
3V & 5V / 13.42 / ON / ON / 64
50
ppm
3V & 5V / 13.42 / ON / ON / 128
100
ppm
3V & 5V / 214.65 / ON / ON / all
0.5
ppm/°C
5V / 214.65 / ON / OFF / 1, TA = 150°C
5.9
ppm / 1000
hours
5V / 214.65 / ON / ON / 1, TA = 150°C
1.6
ppm / 1000
hours
CONVERTER'S CHARACTERISTIC
CMRR
Input Common
Mode Rejection
Ratio
Reference
Common Mode
Rejection
DC, 3V / 214.65 / ON / ON / 1
70
117
dB
DC, 5V / 214.65 / OFF / OFF / 1
90
120
dB
50/60 Hz, 5V / 214.65 / OFF / OFF / 1
117
dB
VREF = 2.5V
101
dB
115
dB
112
dB
PSRR
Power Supply
Rejection Ratio
DC, 3V / 214.65 / ON / ON / 1
NMRR
Normal Mode
Rejection Ratio
(Note 5)
47 Hz to 63 Hz, 5V / 13.42 / OFF / OFF /
1
78
3V / 214.65 / OFF / OFF / 1
95
136
dB
5V / 214.65 / OFF / OFF / 1
95
143
dB
Cross-talk
75
DC, 5V / 214.65 / ON / ON / 1
dB
POWER SUPPLY CHARACTERISTICS
VA
Analog Supply
Voltage
2.85
3.0
5.5
V
VIO
Digital Supply
Voltage
2.7
3.3
5.5
V
3V / 13.42 / OFF / OFF / 1, ext. CLK
400
500
µA
5V / 13.42 / OFF / OFF / 1, ext. CLK
464
555
µA
3V / 13.42 / ON / OFF / 64, ext. CLK
600
700
µA
IVA
Analog Supply
Current
www.national.com
5V / 13.42 / ON / OFF / 64, ext. CLK
690
800
µA
3V / 214.65 / ON / OFF / 64, int. CLK
1547
1700
µA
5V / 214.65 / ON / OFF / 64, int. CLK
1760
2000
µA
3V / 214.65 / OFF / OFF / 1, int. CLK
826
1000
µA
5V / 214.65 / OFF / OFF / 1, int. CLK
941
1100
µA
Standby, 3V , int. CLK
3
10
µA
Standby, 3V , ext. CLK
257
µA
Standby, 5V, int. CLK
5
Standby, 3V, ext. CLK
300
Power-down, 3V, int/ext CLK
2.6
5
µA
Power-down, 5V, int/ext CLK
4.6
9
µA
8
15
µA
µA
Parameter
Conditions
Min
Typ
Max
Units
VREFN + 0.5
VA
V
GND
VREFP - 0.5
V
0.5
VA
V
REFERENCE INPUT
VREFP
Positive Reference
VREFN
Negative
Reference
VREF
Differential
Reference
VREF = VREFP - VREFN
ZREF
Reference
Impedance
3V / 13.42 / OFF / OFF / 1
10
MOhm
IREF
Reference Input
3V / 13.42 / ON or OFF / ON or OFF /
all
±2
µA
CREFP
Capacitance of the
(Note 5), gain = 1
Positive Reference
6
pF
CREFN
Capacitance of the
Negative
(Note 5), gain = 1
Reference
6
pF
Reference
Leakage Current
1
nA
ILREF
Power-down
ANALOG INPUT
VINP
VINN
Positive Input
Negative Input
Gain = 1-8, buffer ON
GND + 0.1
VA - 0.1
V
Gain = 16 - 128, buffer ON
GND + 0.4
VA - 1.5
V
Gain = 1-8, buffer OFF
GND
VA
V
Gain = 1-8, buffer ON
GND + 0.1
VA - 0.1
V
Gain = 16 - 128, buffer ON
GND + 0.4
VA - 1.5
V
GND
VA
V
Gain = 1-8, buffer OFF
VIN
Differential Input
VIN = VINP - VINN
ZIN
Differential Input
Impedance
ODR = 13.42 SPS
±VREF / PGA
15.4
MOhm
CINP
Capacitance of the 5V / 214.65 / OFF / OFF / 1
Positive Input
4
pF
CINN
Capacitance of the 5V / 214.65 / OFF / OFF / 1
Negative Input
4
pF
3V & 5V / 13.42 / ON / OFF / 1-8
500
pA
3V & 5V / 13.42 / ON / OFF / 16 - 128
100
pA
IIN
Input Leakage
Current
DIGITAL INPUT CHARACTERISTICS at VA = VIO = VREF = 3.0V
VIH
Logical "1" Input
Voltage
VIL
Logical "0" Input
Voltage
IIL
Digital Input
Leakage Current
VHYST
0.7 x VIO
V
-10
Digital Input
Hysteresis
0.3 x VIO
V
+10
µA
0.1 x VIO
V
DIGITAL OUTPUT CHARACTERISTICS at VA = VIO = VREF = 3.0V
VOH
Logical "1" Output
Voltage
Source 300 µA
VOL
Logical "0" Output
Voltage
Sink 300 µA
IOZH,
IOZL
TRISTATE®Leakage
Current
COUT
TRI-STATE
Capacitance
2.6
V
-10
(Note 5)
5
9
0.4
V
10
µA
pF
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
Symbol
LMP90080/LMP90079/LMP90078/LMP90077
Symbol
Parameter
Conditions
Min
Typ
Max
Units
EXCITATION CURRENT SOURCES CHARACTERISTICS (LMP90080/LMP90078 only)
IB1, IB2
0, 100, 200,
300, 400, 500,
600, 700, 800,
900, 1000
Excitation Current
Source Output
IB1/IB2 Tolerance
VA = VREF = 3V
-7
2.5
7
%
VA = VREF = 5V
-3.5
0.2
3.5
%
IB1/IB2 Output
VA = 3.0V & 5.0V,
Compliance Range IB1/IB2 = 100 µA to 1000 µA
IB1/IB2 Regulation
IBTC
IBMT
IBMTC
IB1/IB2 Drift
IB1/IB2 Matching
IB1/IB2 Matching
Drfit
µA
VA - 0.8
V
0.07
%/V
VA = 3.0V
95
ppm/°C
VA = 5.0V
60
ppm/°C
VA = 5.0V,
IB1/IB2 = 100 µA to 1000 µA
3V & 5V / 214.65 / OFF / OFF / 1,
IB1/IB2 = 100 µA
0.34
1.53
%
3V & 5V / 214.65 / OFF / OFF / 1,
IB1/IB2 = 200 µA
0.22
1
%
3V & 5V / 214.65 / OFF / OFF / 1,
IB1/IB2 = 300 µA
0.2
0.85
%
3V & 5V / 214.65 / OFF / OFF / 1,
IB1/IB2 = 400 µA
0.15
0.8
%
3V & 5V / 214.65 / OFF / OFF / 1,
IB1/IB2 = 500 µA
0.14
0.7
%
3V & 5V / 214.65 / OFF / OFF / 1,
IB1/IB2 = 600 µA
0.13
0.7
%
3V & 5V / 214.65 / OFF / OFF / 1,
IB1/IB2 = 700 µA
0.075
0.65
%
3V & 5V / 214.65 / OFF / OFF / 1,
IB1/IB2 = 800 µA
0.085
0.6
%
3V & 5V / 214.65 / OFF / OFF / 1,
IB1/IB2 = 900 µA
0.11
0.55
%
3V & 5V / 214.65 / OFF / OFF / 1,
IB1/IB2 = 1000 µA
0.11
0.45
%
VA = 3.0V & 5.0V,
IB1/IB2 = 100 µA to 1000 µA
2
ppm/°C
893
kHz
INTERNAL/EXTERNAL CLK
CLKIN
Internal Clock
Frequency
CLKEXT
External Clock
Frequency
External Crystal
Frequency
(Note 5)
1.8
MHz
0
V
Input High Voltage
1
V
Frequency
1.8
3.5717
7.2
MHz
10
MHz
7
Serial Clock
www.national.com
7.2
Input Low Voltage
Start-up time
SCLK
3.5717
10
ms
Gain
ODR (SPS)
1
2
4
8
16
32
64
128
1.6775
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
3.355
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (14.5)
6.71
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (16)
16 (16)
16 (15)
16 (14.5)
13.42
16 (16)
16 (16)
16 (15.5)
16 (15)
16 (16)
16 (15.5)
16 (15)
16 (14)
26.83125
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (15)
53.6625
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15)
16 (14.5)
107.325
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (16)
16 (15.5)
16 (14.5)
16 (14)
214.65
16 (16)
16 (16)
16 (15.5)
16 (15)
16 (16)
16 (15)
16 (14.5)
16 (13.5)
TABLE 2. RMS Noise (µV) vs. Sampling Rate and Gain at VA = VIO = VREF = 3V
Gain of the ADC
ODR (SPS)
1
2
4
8
16
32
64
128
1.6775
3.08
1.90
1.53
1.27
0.23
0.21
0.15
0.14
3.355
4.56
2.70
2.21
1.67
0.34
0.27
0.24
0.26
6.71
6.15
4.10
3.16
2.39
0.51
0.40
0.37
0.35
13.42
8.60
5.85
4.29
3.64
0.67
0.54
0.51
0.49
26.83125
3.35
2.24
1.65
1.33
0.33
0.27
0.26
0.25
53.6625
4.81
3.11
2.37
1.90
0.44
0.39
0.37
0.36
107.325
6.74
4.51
3.38
2.66
0.63
0.54
0.52
0.49
214.65
9.52
6.37
4.72
3.79
0.90
0.79
0.72
0.70
TABLE 3. ENOB (Noise Free Resolution) vs. Sampling Rate and Gain at VA = VIO = VREF = 5V
Gain of the ADC
SPS
1
2
4
8
16
32
64
1.6775
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
128
3.355
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
6.71
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15)
13.42
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (15)
26.83125
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
53.6625
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15)
107.325
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (14.5)
214.65
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15)
16 (14)
TABLE 4. RMS Noise (µV) vs. Sampling Rate and Gain at VA = VIO = VREF = 5V
Gain of the ADC
SPS
1
2
4
8
16
32
64
128
1.6775
2.68
1.65
1.24
1.00
0.22
0.19
0.17
0.16
3.355
3.86
2.36
1.78
1.47
0.34
0.27
0.22
0.22
6.71
5.23
3.49
2.47
2.09
0.44
0.34
0.30
0.32
13.42
7.94
5.01
3.74
2.94
0.61
0.50
0.45
0.43
26.83125
2.90
1.86
1.34
1.08
0.29
0.24
0.23
0.23
53.6625
4.11
2.60
1.90
1.50
0.39
0.35
0.32
0.31
107.325
5.74
3.72
2.72
2.11
0.56
0.48
0.46
0.44
214.65
8.25
5.31
3.82
2.97
0.79
0.68
0.64
0.63
11
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
TABLE 1. ENOB (Noise Free Resolution) vs. Sampling Rate and Gain at VA = VIO = VREF = 3V
LMP90080/LMP90079/LMP90078/LMP90077
13.0 Timing Diagrams
Unless otherwise noted, specified limits apply for VA = VIO = 3.0V. Boldface limits apply for TMIN ≤ TA ≤ TMAX; the typical values
apply for TA = +25°C.
30169701
FIGURE 2. Timing Diagram
Symbol
Parameter
Conditions
Min
Typical
fSCLK
Max
10
Units
MHz
tCH
SCLK High time
0.4 / fSCLK
ns
tCL
SCLK Low time
0.4 / fSCLK
ns
30169702
30169703
Symbol
Parameter
tCSSU
CSB Setup time prior to an SCLK
rising edge
5
ns
tCSH
CSB Hold time after the last rising
edge of SCLK
6
ns
www.national.com
Conditions
12
Min
Typical
Max
Units
30169705
Symbol
Parameter
Conditions
Min
Typical
Max
Units
tCLKR
SCLK Rise time
1.15
ns
tCLKF
SCLK Fall time
1.15
ns
tDISU
SDI Setup time prior to an SCLK
rising edge
5
ns
tDIH
SDI Hold time after an SCLK rising
edge
6
ns
30169706
30169707
Symbol
Parameter
tDOA
SDO Access time after an SCLK
falling edge
tDOH
SDO Hold time after an SCLK
falling edge
tDOD1
SDO Disable time after the rising
edge of CSB
Conditions
Min
Typical
Max
Units
35
ns
5
ns
5
13
ns
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
30169704
LMP90080/LMP90079/LMP90078/LMP90077
30169708
Symbol
tDOD2
Parameter
30169709
Conditions
Min
Typical
SDO Disable time after either
edge of SCLK
Max
Units
27
ns
30169711
30169710
Symbol
Parameter
tDOE
SDO Enable time from the falling
edge of the 8th SCLK
tDOR
SDO Rise time
(Note 5)
tDOF
SDO Fall time
tDRDYB
Data Ready Bar pulse at every
1/ODR second
Conditions
Min
Typical
Max
Units
35
ns
7
ns
(Note 5)
7
ns
ODR ≤ 13.42 SPS
64
µs
13.42 < ODR ≤ 214.65 SPS
4
µs
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed
specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test
conditions.
Note 2: All voltages are measured with respect to GND, unless otherwise specified
Note 3: When the input voltage (VIN) exceeds the power supply (VIN < GND or VIN > VA), the current at that pin must be limited to 5mA and VIN has to be within
the Absolute Maximum Rating for that pin. The 20 mA package input current rating limits the number of pins that can safely exceed the power supplies with current
flow to four pins.
Note 4: The maximum power dissipation is a function of TJ(MAX) AND θJA. The maximum allowable power dissipation at any ambient temperature is PD = (TJ
(MAX) - TA) / θJA.
Note 5: This parameter is guaranteed by design and/or characterization and is not tested in production.
www.national.com
14
COMMON MODE REJECTION RATIO is a measure of how
well in-phase signals common to both input pins are rejected.
To calculate CMRR, the change in output offset is measured
while the common mode input voltage is changed.
CMRR = 20 LOG(ΔCommon Input / ΔOutput Offset)
EFFECTIVE NUMBER OF BITS (ENOB, or EFFECTIVE
BITS) – says that the converter is equivalent to a perfect ADC
of this (ENOB) number of bits. LMP90080’s ENOB is a DC
ENOB spec, not the dynamic ENOB that is measured using
FFT and SINAD. Its equation is as follows:
ODR Output Data Rate.
OFFSET ERROR is the difference between the differential
input voltage at which the output code transitions from code
0000h to 0001h and 1 LSB.
POSITIVE FULL-SCALE ERROR is the difference between
the differential input voltage at which the output code transitions to positive full scale and (VREF – 1LSB).
POSITIVE GAIN ERROR is the difference between the positive full-scale error and the offset error divided by (VREF /
Gain).
POWER SUPPLY REJECTION RATIO (PSRR) is a measure
of how well a change in the analog supply voltage is rejected.
PSRR is calculated from the ratio of the change in offset error
for a given change in supply voltage, expressed in dB.
PSRR = 20 LOG (ΔVA / ΔOutput Offset)
GAIN ERROR is the deviation from the ideal slope of the
transfer function.
INTEGRAL NON-LINEARITY (INL) is a measure of the deviation of each individual code from a straight line through the
input to output transfer function. The deviation of any given
code from this straight line is measured from the center of that
code value. The end point fit method is used. INL for this
product is specified over a limited range, per the Electrical
Tables.
NEGATIVE FULL-SCALE ERROR is the difference between
the differential input voltage at which the output code transitions to negative full scale and (-VREF + 1LSB).
15
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
NEGATIVE GAIN ERROR is the difference between the negative full-scale error and the offset error divided by (VREF /
Gain).
NOISE FREE RESOLUTION is a method of specifying the
number of bits for a converter with noise.
14.0 Specific Definitions
Unless otherwise noted, specified limits apply for VA =
VIO = VREF = 3.0V. The maximum and minimum values apply for TA = TMIN to TMAX; the typical values apply for TA = +25°C.
Noise Measurement with Calibration at Gain = 1
250
50
230
30
VOUT (μV)
VOUT (μV)
Noise Measurement without Calibration at Gain = 1
210
190
170
10
-10
-30
VA = 3V
150
0
200
VA = 3V
400
600
TIME (ms)
800
-50
1000
0
200
400
600
TIME (ms)
800
1000
30169715
30169716
Histogram without Calibration at Gain = 1
Histogram with Calibration at Gain = 1
30169721
30169722
Noise Measurement without Calibration at Gain = 8
Noise Measurement with Calibration at Gain = 8
40
20
35
15
30
10
25
5
VOUT (μV)
VOUT (μV)
LMP90080/LMP90079/LMP90078/LMP90077
15.0 Typical Performance Characteristics
20
15
10
-5
-10
5
-15
VA = 3V
0
0
200
VA = 3V
-20
400
600
TIME (ms)
800
1000
0
30169717
www.national.com
0
200
400
600
TIME (ms)
800
1000
30169718
16
Histogram with Calibration at Gain = 8
30169723
30169724
Noise Measurement with Calibration at Gain = 128
4
4
3
3
2
2
1
1
VOUT (μV)
VOUT (μV)
Noise Measurement without Calibration at Gain = 128
0
-1
-2
0
-1
-2
-3
-3
VA = 3V
-4
0
200
VA = 3V
-4
400
600
TIME (ms)
800
1000
0
200
400
600
TIME (ms)
800
1000
30169719
30169720
Histogram without Calibration at Gain = 128
Histogram with Calibration at Gain = 128
30169725
30169726
17
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
Histogram without Calibration at Gain = 8
Noise vs. Gain with Calibration at ODR = 13.42 SPS
30169741
30169748
Noise vs. Gain with Calibration at ODR = 214.65 SPS
Noise vs. Gain without Calibration at ODR = 214.65 SPS
30169749
30169750
Offset Error vs. Temperature without Calibration at Gain = 1 Offset Error vs. Temperature with Calibration at Gain = 1
300
2.0
VA = 3V
250
OFFSET VOLTAGE (μV)
OFFSET VOLTAGE (μV)
LMP90080/LMP90079/LMP90078/LMP90077
Noise vs. Gain without Calibration at ODR = 13.42 SPS
200
150
VA = 5V
VA = 3V
100
50
0
1.0
0.5
VA = 5V
0.0
-40 -20
0 20 40 60 80 100 120
TEMPERATURE (°C)
-40 -20
30169761
www.national.com
1.5
0 20 40 60 80 100 120
TEMPERATURE (°C)
30169764
18
0.4
20
OFFSET VOLTAGE (uV)
OFFSET VOLTAGE ( μV)
25
VA = 5V
15
10
VA = 3V
5
0
0.2
VA = 3V
0.0
-0.2
VA = 5V
-0.4
-40 -20
0 20 40 60 80 100 120
TEMPERATURE (°C)
-40 -20
0 20 40 60 80 100 120
TEMPERATURE (°C)
30169762
30169765
Gain Error vs. Temperature without Calibration at Gain = 1
Gain Error vs. Temperature with Calibration at Gain = 1
40
150
VA = 5V
GAIN ERROR (ppm)
GAIN ERROR (ppm)
160
140
130
120
VA = 3V
110
20
VA = 5V
0
-20
-40
-40 -20
0 20 40 60 80 100 120
TEMPERATURE (°C)
-40 -20
VA = 3V
0 20 40 60 80 100 120
TEMPERATURE (°C)
30169767
30169770
Gain Error vs. Temperature without Calibration at Gain = 8
Gain Error vs. Temperature with Calibration at Gain = 8
-100
-20
-120
GAIN ERROR (ppm)
GAIN ERROR (ppm)
-110
VA = 3V
-130
-140
VA = 5V
-150
-160
-40 -20
-40
VA = 3V
-60
-80
VA = 5V
-100
-120
0 20 40 60 80 100 120
TEMPERATURE (°C)
-40 -20
30169768
0 20 40 60 80 100 120
TEMPERATURE (°C)
30169771
19
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
Offset Error vs. Temperature without Calibration at Gain = 8 Offset Error vs. Temperature with Calibration at Gain = 8
0
-20
-20
-40
-40
GAIN (dB)
GAIN (dB)
Digital Filter Frequency Response
0
-60
-80
-100
-120
10
FREQUENCY (Hz)
100
10
30169751
10
5
0
-5
VA = 5V, 13.4 SPS
-5 -4 -3 -2 -1 0 1
VIN (V)
2
3
4
100
FREQUENCY (Hz)
1k
30169753
INL at Gain = 1
5
30169727
www.national.com
26.83 SPS
53.66 SPS
107.33 SPS
214.65 SPS
-120
1
-10
-60
-80
1.7 SPS
3.4 SPS
6.7 SPS
13.4 SPS
-100
INL (ppm of FSR)
LMP90080/LMP90079/LMP90078/LMP90077
Digital Filter Frequency Response
20
Throughout this datasheet, the LMP90080/LMP90079/
LMP90078/LMP90077 will be referred to as the LMP900xx.
The LMP900xx is a low-power 16-Bit ΣΔ ADC with 4 fully differential / 7 single-ended analog channels for the LMP90080/
LMP90079 and 2 full differential / 4 single-ended for the
LMP90078/LMP90077. Its serial data output is two’s complement format. The output data rate (ODR) ranges from 1.6775
SPS to 214.65 SPS.
The serial communication for LMP900xx is SPI, a synchronous serial interface that operates using 4 pins: chip
select bar (CSB), serial clock (SCLK), serial data in (SDI), and
serial data out / data ready bar (SDO/DRYDYB).
True continuous built-in offset and gain background calibration is also available to improve measurement accuracy. Unlike other ADCs, the LMP900xx’s background calibration can
run without heavily impacting the input signal. This unique
technique allows for positive as well as negative gain calibration and is available at all gain settings.
The registers can be found in Section 18.0 Registers, and a
detailed description of the LMP900xx are provided in the following sections.
16.1.2 Flexible Input MUX (VIN)
LMP900xx provides a flexible input MUX as shown in Figure
3. The input that is digitized is VIN = VINP – VINN; where
VINP and VINN can be any availablie input.
The digitized input is also known as a channel, where
CH = VIN = VINP – VINN. Thus, there are a maximum of 4
differential channels: CH0, CH1, CH2, and CH3 for the
LMP90080/LMP90079. The LMP90078/LMP90077 has 2 differential channels: CH0 and CH1 because it does not have
the VIN3, VIN4, and VIN5 pins.
LMP900xx can also be configured single-endedly, where the
common ground is any one of the inputs. There are a maximum of 7 single-ended channels: CH0, CH1, CH2, CH3, CH4,
CH5, and CH6 for the LMP90080/LMP90079 and 4: CH0,
CH1, CH2, CH3 for the LMP90078/LMP90077.
The input MUX can be programmed in the CHx_INPUTCN
registers. For example on the LMP90080, to program CH0 =
VIN = VIN4 – VIN1, go to the CH0_INPUTCN register and set:
1. VINP = 0x4
2. VINN = 0x1
16.1 SIGNAL PATH
16.1.1 Reference Input (VREF)
The differential reference voltage VREF (VREFP – VREFN)
sets the range for VIN.
The muxed VREF allows the user to choose between VREF1
or VREF2 for each channel. This selection can be made by
30169777
FIGURE 3. Simplified VIN Circuitry
21
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
programming the VREF_SEL bit in the CHx_INPUTCN registers (CHx_INPUTCN: VREF_SEL). The default mode is
VREF1. If VREF2 is used, then VIN6 and VIN7 cannot be
used as inputs because they share the same pin.
Refer to Section 17.2.2 VREF for VREF applications information.
16.0 Functional Description
LMP90080/LMP90079/LMP90078/LMP90077
When gain ≥ 16, the buffer is automatically included in the
signal path. When gain < 16, including or excluding the buffer
from the signal path can be done by programming the
CHX_CONFIG: BUF_EN bit.
16.1.3 Selectable Gains (FGA & PGA)
LMP900xx provides two types of gain amplifiers: a fixed gain
amplifier (FGA) and a programmable gain amplifier (PGA).
FGA has a fixed gain of 16x or it can be bypassed, while the
PGA has programmable gain settings of 1x, 2x, 4x, or 8x.
Total gain is defined as FGA x PGA. Thus, LMP900xx provides gain settings of 1x, 2x, 4x, 8x, 16x, 32x, 64x, or 128x
with true continuous background calibration.
The gain is channel specific, which means that one channel
can have one gain, while another channel can have the same
or a different gain.
The gain can be selected by programming the CHx_CONFIG:
GAIN_SEL bits.
16.1.5 Internal/External CLK Selection
LMP900xx allows two clock options: internal CLK or external
CLK (crystal (XTAL) or clock source).
There is an “External Clock Detection” mode, which detects
the external XTAL if it is connected to XOUT and XIN. When
operating in this mode, the LMP900xx shuts off the internal
clock to reduce power consumption. Below is a flow chart to
help set the appropriate clock registers.
16.1.4 Buffer (BUFF)
There is an internal unity gain buffer that can be included or
excluded from the signal path. Including the buffer provides a
high input impedance but increases the power consumption.
30169778
FIGURE 4. CLK Register Settings
The recommended value for the external CLK is discussed in
the next sections.
case, use the equation below to calculate the new ODR values.
16.1.6 Programmable ODRs
If using the internal CLK or external CLK of 3.5717 MHz, then
the output date rates (ODR) can be selected (using the
ODR_SEL bit) as:
1. 13.42/8 = 1.6775 SPS
2. 13.42/4 = 3.355 SPS
3. 13.42/2 = 6.71SPS
4. 13.42 SPS
5. 214.65/8 = 26.83125 SPS
6. 214.65/4 = 53.6625 SPS
7. 214.65/2 = 107.325 SPS
8. 214.65 SPS (default)
If the internal CLK is not being used and the external CLK is
not 3.5717 MHz, then the ODR will be different. If this is the
ODR_Base1 = (CLKEXT) / (266,240)
www.national.com
ODR_Base2 = (CLKEXT) / (16,640)
ODR1 = (ODR_Base1) / n, where n = 1,2,4,8
ODR2 = (ODR_Base2) / n, where n = 1,2,4,8
For example, a 3.6864 MHz XTAL or external clock has the
following ODR values:
ODR_Base1 = (3.6864 MHz) / (266,240) = 13.85 SPS
ODR_Base2 = (3.6864 MHz) / (16,640) = 221.54 SPS
ODR1 = (13.85 SPS) / n = 13.85, 6.92, 3.46, 1.73 SPS
ODR2 = (221.54 SPS) / n = 221.54, 110.77, 55.38, 27.69 SPS
22
scanning. For example, if the ADC were running at 214.65
SPS and four channels are being scanned, then the ODR per
channel would be 214.65/4 = 53.6625 SPS.
23
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
The ODR is channel specific, which means that one channel
can have one ODR, while another channel can have the same
or a different ODR.
Note that these ODRs are meant for a single channel conversion; the ODR needs to be divided by n for n channels
The LMP900xx has a fourth order rotated sinc filter that is used to configure various ODRs and to reject power supply frequencies
of 50Hz and 60Hz. The 50/60 Hz rejection is only effective when the device is operating at ODR ≤ 13.42 SPS. If the internal CLK
or the external CLK of 3.5717 MHz is used, then the LMP900xx will have the frequency response shown in Figure 5 through Figure
9.
0
1.6775 SPS
3.355 SPS
-20
GAIN (dB)
-40
-60
-80
-100
-120
0
12
24
36
48
60
72
84
96
108
120
FREQUENCY (Hz)
30169760
FIGURE 5. Digital Filter Response, 1.6775 SPS and 3.355 SPS
0
6.71 SPS
13.42 SPS
-20
-40
GAIN (dB)
LMP90080/LMP90079/LMP90078/LMP90077
16.1.7 Digital Filter
-60
-80
-100
-120
0
12
24
36
48
60
72
84
96
108
120
FREQUENCY (Hz)
30169773
FIGURE 6. Digital Filter Response, 6.71 SPS and 13.42 SPS
www.national.com
24
LMP90080/LMP90079/LMP90078/LMP90077
-60
13.42 SPS
-70
GAIN (dB)
-80
-90
-100
-110
-120
45
47
49
51
53
55
57
59
61
63
65
FREQUENCY (Hz)
30169744
FIGURE 7. Digital Filter Response at 13.42 SPS
0
26.83125 SPS
53.6625 SPS
GAIN (dB)
-40
-80
-120
0
200
400
600
800
1000
1200
1400
1600
1800
2000
FREQUENCY (Hz)
30169786
FIGURE 8. Digital Filter Response, 26.83125 SPS and 53.6625 SPS
25
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
0
107.325 SPS
214.65 SPS
GAIN (dB)
-40
-80
-120
0
200
400
600
800
1000
1200
1400
1600
1800
2000
FREQUENCY (Hz)
30169787
FIGURE 9. Digital Filter Response 107.325 SPS and 214.65 SPS
If the internal CLK is not being used and the external CLK is not 3.5717 MHz, then the filter response would be the same as the
response shown above, but the frequency will change according to the equation:
fNEW = [(CLKEXT) / 256 ] x (fOLD / 13.952k)
Using the equation above, an example of the filter response for a 3.5717 MHz XTAL versus a 3.6864 MHz XTAL can be seen in
Figure 10.
0
Crystal = 3.5717 MHz
Crystal = 3.6864 MHz
-20
GAIN (dB)
-40
-60
-80
-100
-120
-140
40
45
50
55
60
FREQUENCY (Hz)
65
70
30169756
FIGURE 10. Digital Filter Response for a 3.5717MHz
versus 3.6864 MHz XTAL
www.national.com
26
30169733
FIGURE 11. GPIO Register Settings
16.2 CALIBRATION
As seen in Figure 12, there are two types of calibration: background calibration and system calibration. These calibrations
are further described in the next sections.
30169779
FIGURE 12. Types of Calibration
Figure 12 also shows that there are two types of background
calibration:
1. Type 1: Correction - the process of continuously
determining and applying the offset and gain calibration
coefficients to the output codes to minimize the
LMP900xx’s offset and gain errors.
This method keeps track of changes in the LMP900xx's
gain and offset errors due to changes in the operating
condition such as voltage, temperature, or time.
2. Type 2: Estimation - the process of determining and
continuously applying the last known offset and gain
16.2.1 Background Calibration
Background calibration is the process of continuously determining and applying the offset and gain calibration coefficients to the output codes to minimize the LMP900xx’s offset
and gain errors. Background calibration is a feature built into
the LMP900xx and is automatically done by the hardware
without interrupting the input signal.
Four differential channels, CH0-CH3, each with its own gain
and ODRs, can be calibrated to improve the accuracy.
Types of Background Calibration:
27
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
Figure 11 shows a flowchart how these GPIOs can be programmed.
16.1.8 GPIO (D0–D6)
Pins D0-D6 are general purpose input/output (GPIO) pins that
can be used to control external LEDs or switches. Only a high
or low value can be sourced to or read from each pin.
LMP90080/LMP90079/LMP90078/LMP90077
The System Calibration Offset Registers (CHx_SCAL_OFFSET) hold the System Calibration Offset Coefficients in 16bit, two's complement binary format. The System Calibration
Gain Registers (CHx_SCAL_GAIN) hold the System Calibration Gain Coefficient in 16-bit, 1.15, unsigned, fixed-point
binary format. For each channel, the System Calibration Offset coefficient is subtracted from the conversion result prior
to the division by the System Calibration Gain coefficient.
A data-flow diagram of these coefficients can be seen in Figure 14.
calibration coefficients to the output codes to minimize
the LMP900xx’s offset and gain errors.
The last known offset or gain calibration coefficients can
come from two sources. The first source is the default
coefficient which is pre-determined and burnt in the
device’s non-volatile memory. The second source is from
a previous calibration run of Type 1: Correction.
The benefits of using type 2 calibration is a higher throughput,
lower power consumption, and slightly better noise. The exact
savings would depend on the number of channels being
scanned, and the ODR and gain of each channel.
Using Background Calibration:
There are four modes of background calibration, which can
be programmed using the BGCALCN bits. They are as follows:
1. BgcalMode0: Background Calibration OFF
2. BgcalMode1: Offset Correction / Gain Estimation
3. BgcalMode2: Offset Correction / Gain Correction
Follow Figure 13 to set other appropriate registers when
using this mode.
4. BgcalMode3: Offset Estimation / Gain Estimation
30169731
FIGURE 14. System Calibration Data-Flow Diagram
There are four distinct sets of System Calibration Offset and
System Calibration Gain Registers for use with CH0-CH3.
CH4-CH6 reuse the registers of CH0-CH2, respectively.
The LMP900xx provides two system calibration modes that
automatically fill the Offset and Gain coefficients for each
channel. These modes are the System Calibration Offset Coefficient Determination mode and the System Calibration
Gain Coefficient Determination mode. The System Calibration Offset Coefficient Determination mode must be entered
prior to the System Calibration Gain Coefficient Determination mode, for each channel.
The system zero-scale condition is a system input condition
(sensor loading) for which zero (0x0000) system-calibrated
output code is desired. It may not, however, cause a zero input voltage at the input of the ADC.
The system reference-scale condition is usually the system
full-scale condition in which the system's input (or sensor's
loading) would be full-scale and the desired system-calibrated output code would be 0x8000 (unsigned 16-bit binary).
However, system full-scale condition need not cause fullscale input voltage at the input of the ADC.
The system reference-scale condition is not restricted to just
the system full-scale condition. In fact, it can be any arbitrary
fraction of full-scale (up to 1.25 times) and the desired systemcalibrated output code can be any appropriate value (up to
0xA000). The CHx_SCAL_GAIN register must be written with
the desired system-calibrated output code (default:0x8000)
before entering the System Calibration Gain Coefficient Determination mode. This helps in in-place system calibration.
Below are the detailed procedures for using the System Calibration Offset Coefficient Determination and System Calibration Gain Coefficient Determination modes.
30169730
FIGURE 13. BgcalMode2 Register Settings
If operating in BgcalMode2, four channels (with the same
ODR) are being converted, and FGA_BGCAL = 0 (default),
then the ODR is reduced by:
1. 0.19% of 1.6775 SPS
2. 0.39% of 3.355 SPS
3. 0.78% of 6.71 SPS
4. 1.54% of 13.42 SPS
5. 3.03% of 26.83125 SPS
6. 5.88% of 53.6625 SPS
7. 11.11% of 107.325 SPS
8. 20% of 214.65 SPS
System Calibration Offset Coefficient Determination
mode
1. Apply system zero-scale condition to the channel (CH0/
CH1/CH2/CH3).
2. Enter the System Calibration Offset Coefficient
Determination mode by programming 0x1 in the
SCALCN register.
3. LMP900xx starts a fresh conversion at the selected
output data rate for the selected channel. At the end of
16.2.2 System Calibration
The LMP900xx provides some unique features to support
easy system offset and system gain calibrations.
www.national.com
28
5.
30169742
FIGURE 15. Post-calibration Scaling Data-Flow Diagram
System Calibration Gain Coefficient Determination mode
1. Repeat the System Calibration Offset Coefficient
Determination to calibrate the System offset for the
channel.
2. Apply the system reference-scale condition to the
channel CH0/CH1/CH2/CH3.
3. In the CHx_SCAL_GAIN register, program the expected
(desired) system-calibrated output code for this condition
in 16-bit unsigned format.
4. Enter the System Calibration Gain Coefficient
Determination mode by programming 0x3 in the
SCALCN register.
5. LMP900xx starts a fresh conversion at the selected
output data rate for the channel. At the end of the
conversion, the CHx_SCAL_GAIN is filled-in (or
overwritten) with the System Calibration Gain coefficient.
6. The System Calibration Gain Coefficient Determination
mode is automatically exited.
7. The computed calibration coefficient is accurate only to
the effective resolution of the device and will probably
contain some noise. The noise factor can be minimized
by computing over many times, averaging (externally)
and putting the resultant value back into the register.
Alternatively, select the output data rate to be 26.83 sps
or 1.67 sps.
16.3 CHANNELS SCAN MODE
There are four scan modes. These scan modes are selected
using the CH_SCAN: CH_SCAN_SEL bit. The first scanned
channel is FIRST_CH, and the last scanned channel is
LAST_CH; they are both located in the CH_SCAN register.
The CH_SCAN register is double buffered. That is, user inputs are stored in a slave buffer until the start of the next
conversion during which time they are transferred to the master buffer. Once the slave buffer is written, subsequent updates are disregarded until a transfer to the master buffer
happens. Hence, it may be appropriate to check the
CH_SCAN_NRDY bit before programming the CH_SCAN
register.
ScanMode0: Single-Channel Continuous Conversion
LMP900xx continuously converts the selected FIRST_CH.
Do not operate in this scan mode if gain ≥ 16 and the LMP900xx is running in background calibration modes BgcalMode1 or BgcalMode2. If this is the case, then it is more
suitable to operate the device in ScanMode2 instead.
ScanMode1: Multiple-Channels Single Scan
LMP900xx converts one or more channels starting from
FIRST_CH to LAST_CH, and then enters the stand-by state.
Post-calibration Scaling
LMP900xx allows scaling (multiplication and shifting) for the
System Calibrated result. This eases downstream processing, if any. Multiplication is done using the System Calibration
Scaling Coefficient in the CHx_SCAL_SCALING register and
shifting is done using the System Calibration Bits Selector in
the CHx_SCAL_BITS_SELECTOR register.
The System Calibration Bits Selector value should ideally be
the logarithm (to the base 2) of the System Calibration Scaling
Coefficient value.
There are four distinct sets of System Calibration Scaling and
System Calibration Bits Selector Registers for use with CH0CH3. CH4-CH6 reuse the registers of CH0-CH2, respectively.
A data-flow diagram of these coefficients can be seen in Figure 15
ScanMode2: Multiple-Channels Continuous Scan
LMP900xx continuously converts one or more channels starting from FIRST_CH to LAST_CH, and then it repeats this
process.
ScanMode3: Multiple-Channels Continuous Scan with
Burnout Currents
This mode is the same as ScanMode2 except that the burnout
current is provided in a serially scanned fashion (injected in a
channel after it has undergone a conversion). Thus it avoids
burnout current injection from interfering with the conversion
result for the channel.
The sensor diagnostic burnout currents are available for all
four scan modes. The burnout current is further gated by the
BURNOUT_EN bit for each channel. ScanMode3 is the only
mode that scans multiple channels while injecting burnout
currents without interfering with the signal. This is described
in details in Section 16.4.2 Burnout Currents.
29
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
4.
the conversion, the CHx_SCAL_OFFSET register is
filled-in with the System Calibration Offset coefficient.
The System Calibration Offset Coefficient Determination
mode is automatically exited.
The computed calibration coefficient is accurate only to
the effective resolution of the device and will probably
contain some noise. The noise factor can be minimized
by computing over many times, averaging (externally)
and putting the resultant value back into the register.
Alternatively, select the output data rate to be 26.83 sps
or 1.67 sps.
LMP90080/LMP90079/LMP90078/LMP90077
16.4 SENSOR INTERFACE
The LMP90080/LMP90078 contains two excitation currents
(IB1 & IB2) for sourcing external sensors, and the LMP900xx
contain two burnout currents for sensor diagnostics. They are
described in the next sections.
Burnout Current Injection:
Burnout currents are injected differently depending on the
channel scan mode selected.
When BURNOUT_EN = 1 and the device is operating in
ScanMode0, 1, or 2, the burnout currents are injected into all
the channels for which the BURNOUT_EN bit is selected.
This will cause problems and hence in this mode, more than
one channel should not have its BURNOUT_EN bit selected.
Also, the burnout current will interfere with the signal and introduce a fixed error depending on the particular external
sensor.
When BURNOUT_EN = 1 and the device is operating in
ScanMode3, burnout currents are injected into the last sampled channel on a cyclical basis (Figure 17). In this mode,
burnout currents injection is truly done in the background
without affecting the accuracy of the on-going conversion.
Operating in this mode is recommended.
16.4.1 IB1 & IB2 - Excitation Currents (LMP90080/
LMP90078)
IB1 and IB2 can be used for providing currents to external
sensors, such as RTDs or bridge sensors. 100µA to 1000µA,
in steps of 100µA, can be sourced by programming the
ADC_AUXCN: RTD_CUR_SEL bits.
Refer to Section 17.6.1 3–Wire RTD to see how IB1 and IB2
can be used to source a 3-wire RTD.
16.4.2 Burnout Currents
As shown in Figure 16, the LMP900xx contains two internal
10 µA burnout current sources, one sourcing current from VA
to VINP, and the other sinking current from VINN to ground.
These currents are used for sensor diagnostics and can be
enabled for each channel using the CHx_INPUTCN:
BURNOUT_EN bit.
30169781
FIGURE 17. Burnout Currents Injection for ScanMode3
16.4.3 Sensor Diagnostic Flags
Burnout currents can be used to verify that an external sensor
is still operational before attempting to make measurements
on that channel. A non-operational sensor means that there
is a possibility the connection between the sensor and the
LMP900xx is open circuited, short circuited, shorted to VA or
GND, overloaded, or the reference may be absent. The sensor diagnostic flags diagram can be seen in Figure 18.
30169780
FIGURE 16. Burnout Currents
www.national.com
30
FIGURE 18. Sensor Diagnostic Flags Diagram
The sensor diagnostic flags are located in the
SENDIAG_FLAGS register and are described in further details below.
POR_AFT_LST_RD:
If POR_AFT_LST_READ = 1, then there was a power-on reset since the last time the SENDIAG_FLAGS register was
read. This flag's status is cleared when this bit is read, unless
this bit is set again on account of another power-on-reset
event in the intervening period.
SHORT_THLD_FLAG:
The short circuit threshold flag is used to report a short-circuit
condition. It is set when the output voltage (VOUT) is within
the absolute Vthreshold. Vthreshold can be programmed using the 8-bit SENDIAG_THLDH register.
For example, assume VREF = 5V, gain = 1, SENDIAG_THLD
= 0xDA (218d). In this case, Vthreshold can be calculated as:
OFLO_FLAGS:
OFLO_FLAGS is used to indicate whether the modulator is
over-ranged or under-ranged. The following conditions are
possible:
1. OFLO_FLAGS = 0x0: Normal Operation
2. OFLO_FLAGS = 0x1: The modulator was not
overranged, but ADC_DOUT got clamped to 0x7FFF
(positive fullscale) or 0x8000 (negative full scale). For
example, if VREF = 5V, VIN = 2V, and gain = 128, then
OFLO_FLAGS would be 01b.
3. OFLO_FLAGS = 0x2: The modulator was over-ranged
towards +VREF.
4. OFLO_FLAGS = 0x3: The modulator was over-ranged
towards −VREF.
The condition of OFLO_FLAGS = 10b or 11b can be used in
conjunction with the RAILS_FLAG to determine the fault condition.
Vthreshold = [(SENDIAG_THLD)(2)(VREF)] / [(Gain)(216)]
Vthreshold = [(218)(2)(5V)] / [(1)(216)]
Vthreshold = 33.3 mV
When
(-33.3mV)
≤ VOUT ≤ (33.3mV), then
SHORT_THLD_FLAG = 1; otherwise, SHORT_THLD_FLAG
= 0.
RAILS_FLAG:
The rails flag is used to detect if one of the sampled channels
is within 50mV of the rails potential (VA or VSS). This can be
further investigated to detect an open-circuit or short-circuit
condition. If the sampled channel is near a rail, then
RAILS_FLAG = 1; otherwise, RAILS_FLAG = 0.
SAMPLED_CH:
These three bits show the channel number for which the
ADC_DOUT and SENDIAG_FLAGS are available. This does
not necessarily indicate the current channel under conversion
because the conversion frame and computation of results
from the channels are pipelined. That is, while the conversion
is going on for a particular channel, the results for the previous
conversion (of the same or a different channel) are available.
31
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
30169782
LMP90080/LMP90079/LMP90078/LMP90077
16.5 SERIAL DIGITAL INTERFACE
A synchronous 4-wire serial peripheral interface (SPI) provides access to the internal registers of LMP900xx via CSB,
SCLK, SDI, SDO/DRDYB.
16.5.2 Register Read/Write Protocol
Figure 19 shows the protocol how to write to or read from a
register.
Transaction 1 sets up the upper register address (URA)
where the user wants to start the register-write or registerread.
Transaction 2 sets the lower register address (LRA) and includes the Data Byte(s), which contains the incoming data
from the master or outgoing data from the LMP900xx.
Examples of register-reads or register-writes can be found in
Section 17.4 REGISTER READ/WRITE EXAMPLES.
16.5.1 Register Address (ADDR)
All registers are memory-mapped. A register address (ADDR)
is composed of an upper register address (URA) and lower
register address (LRA) as shown in ADDR Map. For example,
ADDR 0x3A has URA=0x3 and LRA=0xA.
ADDR Map
Bit
[6:4]
[3:0]
Name
URA
LRA
30169736
FIGURE 19. Register Read/Write Protocol
0x1F, 0x20, 0x21. Once the data reaches ADDR 0x21, LMP900xx will wrap back to ADDR 0x1C and repeat this process
until CSB deasserts. See Section 17.5.2 Controlled Streaming Example for an example of the Controlled Streaming
mode.
If streaming reaches ADDR 0x7F, then it will wrap back to
ADDR 0x00. Furthermore, reading back the Upper Register
Address after streaming will report the Upper Register Address at the start of streaming, not the Upper Register Address at the end of streaming.
To stream, write 0x3 to INST2’s SZ bits as seen in Figure
19. To select the stream type, program the SPI_STREAMCN:
STRM_TYPE bit. The STRM_RANGE can also be programmed in the same register.
16.5.3 Streaming
When writing/reading 3+ bytes, the user must operate the device in Normal Streaming mode or Controlled Streaming
mode. In the Normal Streaming mode, which is the default
mode, data runs continuously starting from ADDR until CSB
deasserts. This mode is especially useful when programming
all the configuration registers in a single transaction. See
Section 17.5.1 Normal Streaming Example for an example of
the Normal Streaming mode.
In the Controlled Streaming mode, data runs continuously
starting from ADDR until the data has run through all
(STRM_RANGE + 1) registers. For example, if the starting
ADDR is 0x1C, STRM_RANGE = 5, then data will be written
to or read from the following ADDRs: 0x1C, 0x1D, 0x1E,
www.national.com
32
16.5.6 DRDYB - Data Ready Bar
DRDYB is a signal generated by the LMP900xx that indicates
a fresh conversion data is available in the ADC_DOUT registers.
DRDYB is automatically asserted every (1/ODR) second as
seen in Figure 20. Before the next assertion, DRDYB will
pulse for tDRDYB second. The value for tDRDYB can be found in
Section 13.0 Timing Diagrams.
16.5.5 SPI Reset
SPI Reset resets the SPI-Protocol State Machine by monitoring the SDI for at least 73 consecutive 1's at each SCLK
30169785
FIGURE 20. DRDYB Behavior
If ADC_DOUT is being read while a new ADC_DOUT becomes available, then the ADC_DOUT that is being read is
still valid (Figure 21). DRDYB will still be deasserted every 1/
ODR second, but a consecutive read on the ADC_DOUT register will fetch the newly converted data available.
30169712
FIGURE 21. DRDYB Behavior for an Incomplete ADC_DOUT Reading
DRDYB can also be accessed via registers using the
DT_AVAIL_B bit. This bit indicates when fresh conversion
data is available in the ADC_DOUT registers. If new conversion data is available, then DT_AVAIL_B = 0; otherwise,
DT_AVAIL_B = 1.
A complete reading for DT_AVAIL_B occurs when the MSB
of ADC_DOUTH is read out. This bit cannot be reset even if
REG_AND_CNV_RST = 0xC3.
DrdybCase1:
Combining
SDO_DRDYB_DRIVER = 0x00
33
SDO/DRDYB
with
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
rising edge. After an SPI Reset, SDI is monitored for a possible Write Instruction at each SCLK rising edge.
SPI Reset will reset the Upper Address Register (URA) to 0,
but the register contents are not reset.
By default, SPI reset is disabled, but it can be enabled by
writing 0x01 to SPI Reset Register (ADDR 0x02).
16.5.4 CSB - Chip Select Bar
An SPI transaction begins when the master asserts (active
low) CSB and ends when the master deasserts (active high)
CSB. Each transaction might be separated by a subsequent
one with a CSB deassertion, but this is optional. Once CSB
is asserted, it must not pulse (deassert and assert again) during a (desired) transaction.
CSB can be grounded in systems where LMP900xx is the only
SPI slave. This frees the software from handling the CSB.
Care has to be taken to avoid any false edge on SCLK, and
while operating in this mode, the streaming transaction should
not be used because exiting from this mode can only be done
through a CSB deassertion.
LMP90080/LMP90079/LMP90078/LMP90077
30169732
FIGURE 22. DrdybCase1 Connection Diagram
As shown in Figure 22, the drdyb signal and SDO can be
multiplexed on the same pin as their functions are mostly
complementary. In fact, this is the default mode for the
SDO/DRDYB pin.
Figure 23 shows a timing protocol for DrdybCase1. In this
case, start by asserting CSB first to monitor a drdyb assertion.
When the drdyb signal asserts, begin writing the Instruction
Bytes (INST1, UAB, INST2) to read from or write to registers.
Note that INST1 and UAB are omitted from the figure below
because this transaction is only required if a new UAB needs
to be implemented.
While the CSB is asserted, DRDYB is driving the
SDO/DRDYB pin unless the device is reading data, in which
case, SDO will be driving the pin. If CSB is deasserted, then
the SDO/DRDYB pin is High-Z.
30169701
FIGURE 23. Timing Protocol for DrdybCase1
can only be used when the LMP900xx is the only device connected to the master's SPI bus because the SDO/DRDYB pin
will be DRDYB even when CSB is deasserted.
The timing protocol for this case can be seen in Figure 24.
When drdyb asserts, assert CSB to start the SPI transaction
and begin writing the Instruction Bytes (INST1, UAB, INST2)
to read from or write to registers.
DrdybCase2:
Combining
SDO/DRDYB
with
SDO_DRDYB_DRIVER = 0x03
SDO/DRDYB can be made independent of CSB by setting
SDO_DRDYB_DRIVER = 0x03 in the SPI Handshake Control
register. In this case, DRDYB will drive the pin unless the device is reading data, independent of the state of CSB. SDO
will drive the pin when CSB is asserted and the device is
reading data.
With this scheme, one can use SDO/DRDYB as a true interrupt source, independent of the state of CSB. But this scheme
www.national.com
34
FIGURE 24. Timing Protocol for DrdybCase2
35
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
30169729
LMP90080/LMP90079/LMP90078/LMP90077
DrdybCase3: Routing DRDYB to D6
30169791
FIGURE 25. DrdybCase3 Connection Diagram
The drdyb signal can be routed to pin D6 by setting
SPI_DRDYB_D6 high and SDO_DRDYB_DRIVER to 0x4.
This is the behavior for DrdybCase3 as shown in Figure 25.
The timing protocol for this case can be seen in Figure 26.
Since DRDYB is separated from SDO, it can be monitored
using the interrupt or polling method. If polled, the drdyb signal
needs to be polled faster than tDRDYB to detect a drdyb assertion. When drdyb asserts, assert CSB to start the SPI
transaction and begin writing the Instruction Bytes (INST1,
UAB, INST2) to read from or write to registers.
30169789
FIGURE 26. Timing Protocol for DrdybCase3
In order to use the data only transaction, the device must be
placed in the data first mode. The following table lists transaction formats for placing the device in and out of the data first
mode and reading the mode status.
16.5.7 Data Only Read Transaction
In a data only read transaction, one can directly access the
data byte(s) as soon as the CSB is asserted without having
to send any instruction byte. This is useful as it brings down
the latency as well as the overhead associated with the instruction byte (as well as the Upper Address Byte, if any).
TABLE 5. Data First Mode Transactions
Bit[7]
Bits[6:5]
Bit[4]
Bits[3:0]
Data Bytes
Enable Data First Mode Instruction
1
11
1
1010
None
Disable Data First Mode Instruction
1
11
1
1011
None
Read Mode Status Transaction
1
00
1
1111
One
www.national.com
36
Transaction; this transaction should be completed before the
next scheduled DRDYB deassertion.
16.5.8 Cyclic Redundancy Check (CRC)
CRC can be used to ensure integrity of data read from LMP900xx. To enable CRC, set EN_CRC high. Once CRC is
enabled, the CRC value is calculated and stored in
SPI_CRC_DAT so that the master device can periodically
read for data comparison. The CRC is automatically reset
when CSB or DRDYB is deasserted.
The CRC polynomial is x8 + x5 + x4 + 1. The reset value of the
SPI_CRC_DAT register is zero, and the final value is onescomplemented before it is sent out. Note that CRC computation only includes the bits sent out on SDO and does not
include the bits of the SPI_CRC_DAT itself; thus it is okay to
read SPI_CRC_DAT repeatedly.
The drdyb signal normally deasserts (active high) every 1/
ODR second. However, this behavior can be changed so that
drdyb deassertion can occur after SPI_CRC_DAT is read, but
not later than normal DRDYB deassertion which occurs at
every 1/ODR seconds. This is done by setting bit
DRDYB_AFT_CRC high.
The timing protocol for CRC can be found in Figure 27.
30169759
FIGURE 27. Timing Protocol for Reading SPI_CRC_DAT
If SPI_CRC_DAT read extends beyond the normal DRDYB
deassertion at every 1/ODR seconds, then CRC_RST has to
be set in the SPI Data Ready Bar Control Register. This is
done to avoid a CRC reset at the DRDYB deassertion.Timing
protocol for reading CRC with CRC_RST set is shown in Figure 28
30169738
FIGURE 28. Timing Protocol for Reading SPI_CRC_DAT beyond normal DRDYB deassertion at every 1/ODR seconds
37
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
Note that while being in the data first mode, once the data
bytes in the data only read transaction are sent out, the device
is ready to start on any normal (non-data-only) transaction
including the Disable Data First Mode Instruction. The current
status of the data first mode (enabled/disabled status) can be
read back using the Read Mode Status Transaction. This
transaction consists of the Read Mode Status Instruction followed by a single data byte (driven by the device). The data
first mode status is available on bit [1] of this data byte.
The data only read transaction allows reading up to eight
consecutive registers, starting from any start address. Usually, the start address will be the address of the most significant byte of conversion data, but it could just as well be any
other address. The start address and number of bytes to be
read during the data only read transaction can be programmed using the DATA_ONLY_1 AND DATA_ONLY_2
registers respectively.
The upper register address is unaffected by a data only read
transaction. That is, it retains its setting even after encountering a data only transaction. The data only transaction uses
its own address (including the upper address) from the
DATA_ONLY_1 register. When in the data first mode, the
SCLK must stop high before entering the Data Only Read
LMP90080/LMP90079/LMP90078/LMP90077
16.7 RESET and RESTART
Writing 0xC3 to the REG_AND_CNV_RST field will reset the
conversion and most of the programmable registers to their
default values. The only registers that will not be reset are the
System Calibration Registers (CHx_SCAL_OFFSET,
CHx_SCAL_GAIN) and the DT_AVAIL_B bit.
If it is desirable to reset the System Calibration Coefficient
Registers, then set RESET_SYSCAL = 1 before writing 0xC3
to REG_AND_CNV_RST. If the device is operating in the
“System Calibration Offset/Gain Coefficient Determination”
mode (SCALCN register), then write REG_AND_CNV_RST
= 0xC3 twice to get out of this mode.
After a register reset, any on-going conversions will be aborted and restarted. If the device is in the power-down state, then
a register reset will bring it out of the power-down state.
To restart a conversion, write 1 to the RESTART bit. This bit
can be used to synchronize the conversion to an external
event.
16.6 POWER MANAGEMENT
The device can be placed in Active, Power-Down, or StandBy state.
In Power-Down, the ADC is not converting data, contents of
the registers are unaffected, and there is a drastic power reduction. In Stand-By, the ADC is not converting data, but the
power is only slightly reduced so that the device can quickly
transition into the active state if desired.
These states can be selected using the PWRCN register.
When written, PWRCN brings the device into the Active, Power-Down, or Stand-By state. When read, PWRCN indicates
the state of the device.
The read value would confirm the write value after a small
latency (approximately 15 µs with the internal CLK). It may be
appropriate to wait for this latency to confirm the state change.
Requests not adhering to this latency requirement may be
rejected.
It is not possible to make a direct transition from the powerdown state to the stand-by state. This state diagram is shown
below.
30169788
FIGURE 29. Active, Power-Down, Stand-by State Diagram
www.national.com
38
17.1 QUICK START
This section shows step-by-step instructions to configure the
LMP900xx to perform a simple DC reading from CH0.
1. Apply VA = VIO = VREFP1 = 5V, and ground VREFN1
2. Apply VINP = ¾VREF and VINN = ¼VREF for CH0.
Thus, set CH0 = VIN = VINP - VINN = ½VREF
(CH0_INPUTCN register)
3. Set gain = 1 (CH0_CONFIG: GAIN_SEL = 0x0)
4. Exclude the buffer from the signal path (CH0_CONFIG:
BUF_EN = 1)
5. Set the background to BgcalMode2 (BGCALCN = 0x2)
6. Select VREF1 (CH0_INPUTCN: VREF_SEL = 0)
7. To use the internal CLK, set CLK_EXT_DET = 1 and
CLK_SEL = 0.
8. Follow the register read/write protocol (Figure 19) to
capture ADC_DOUT from CH0.
17.3 ADC_DOUT CALCULATION
The output code of the LMP900xx can be calculated as:
Equation 1 — Output Code
ADC_DOUT is in 16−bit two's complement binary format. The
largest positive value is 0x7FFF (or 32767 in decimal), while
the largest negative value is 0x8000 (or 32768 in decimal). In
case of an over range the value is automatically clamped to
one of these two values.
Figure 30 shows the theoretical output code, ADC_DOUT, vs.
analog input voltage, VIN, using the equation above.
17.2 CONNECTING THE SUPPLIES
17.2.1 VA and VIO
Any ADC architecture is sensitive to spikes on the analog
voltage, VA, digital input/output voltage, VIO, and ground
pins. These spikes may originate from switching power supplies, digital logic, high power devices, and other sources. To
diminish these spikes, the LMP900xx’s VA and VIO pins
should be clean and well bypassed. A 0.1 µF ceramic bypass
capacitor and a 1 µF tantalum capacitor should be used to
bypass the LMP900xx supplies, with the 0.1 µF capacitor
placed as close to the LMP900xx as possible.
Since the LMP900xx has both external VA and VIO pins, the
user has two options on how to connect these pins. The first
option is to tie VA and VIO together and power them with the
same power supply. This is the most cost effective way of
powering the LMP900xx but is also the least ideal because
noise from VIO can couple into VA and negatively affect performance. The second option involves powering VA and VIO
with separate power supplies. These supply voltages can
have the same amplitude or they can be different.
17.2.2 VREF
Operation with VREF below VA is also possible with slightly
diminished performance. As VREF is reduced, the range of
acceptable analog input voltages is also reduced. Reducing
the value of VREF also reduces the size of the LSB. When
the LSB size goes below the noise floor of the LMP900xx, the
noise will span an increasing number of codes and performance will degrade. For optimal performance, VREF should
30169747
FIGURE 30. ADC_DOUT vs. VIN of a 16-Bit Resolution
(VREF = 5.5V, Gain = 1).
39
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
be the same as VA and sourced with a clean source that is
bypassed with a ceramic capacitor value of 0.1 µF and a tantalum capacitor of 10 µF.
LMP900xx also allows ratiometric connection for noise immunity reasons. A ratiometric connection is when the ADC’s
VREFP and VREFN are used to excite the input device’s (i.e.
a bridge sensor) voltage references. This type of connection
severely attenuates any VREF ripple seen the ADC output,
and is thus strongly recommended.
17.0 Applications Information
LMP90080/LMP90079/LMP90078/LMP90077
17.4 REGISTER READ/WRITE EXAMPLES
17.4.1 Writing to Register Examples
Using the register read/write protocol shown in Figure 19, the following example shows how to write three data bytes starting at
register address (ADDR) 0x1F. After the last byte has been written to ADDR 0x21, deassert CSB to end the register-write.
30169737
FIGURE 31. Register-Write Example 1
The next example shows how to write one data byte to ADDR 0x12. Since the URA for this example is the same as the last example,
transaction 1 can be omitted.
30169790
FIGURE 32. Register-Write Example 2
www.national.com
40
The following example shows how to read two bytes. The first byte will be read from starting ADDR 0x24, and the second byte will
be read from ADDR 0x25.
30169739
FIGURE 33. Register-Read Example
41
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
17.4.2 Reading from Register Example
LMP90080/LMP90079/LMP90078/LMP90077
17.5 STREAMING EXAMPLES
17.5.1 Normal Streaming Example
This example shows how to write six data bytes starting at ADDR 0x28 using the Normal Streaming mode. Because the default
STRM_TYPE is the Normal Streaming mode, setting up the SPI_STREAMCN register can be omitted.
30169792
FIGURE 34. Normal Streaming Example
www.national.com
42
This example shows how to read the 16-bit conversion data (ADC_DOUT) four times using the Controlled Streaming mode. The
ADC_DOUT registers consist of ADC_DOUTH at ADDR 0x1A and ADC_DOUTL at ADDR 0x1B.
The first step (Figure 35) sets up the SPI_STREAMCN register. This step enters the Controlled Streaming mode by setting
STRM_TYPE high in ADDR 0x03. Since two registers (ADDR 0x1A - 0x1B) need to be read, the STRM_RANGE is 1.
30169793
FIGURE 35. Setting up SPI_STREAMCN
The next step shows how to perform the Controlled Streaming mode so that the master device will read ADC_DOUT from ADDR
0x1A and 0x1B, then wrap back to ADDR 0x1A, and repeat this process for four times. After this process, deassert CSB to end
the Controlled Streaming mode.
43
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
17.5.2 Controlled Streaming Example
LMP90080/LMP90079/LMP90078/LMP90077
30169794
FIGURE 36. Controlled Streaming Example
www.national.com
44
LMP90080/LMP90079/LMP90078/LMP90077
17.6 EXAMPLE APPLICATIONS
17.6.1 3–Wire RTD
30169752
FIGURE 37. Topology #1: 3-wire RTD Using 2 Current Sources
Figure 37 shows the first topology for a 3-wire resistive temperature detector (RTD) application. Topology #1 uses two
excitation current sources, IB1 and IB2, to create a differential
voltage across VIN0 and VIN1. As a result of using both IB1
and IB2, only one channel (VIN0-VIN1) needs to be measured. As shown in Equation 2, the equation for this channel
is IB1 x (RTD – RCOMP) assuming that RLINE1 = RLINE2.
The advantage of this circuit is its ratiometric configuration,
where VREF = (IB1 + IB2) x (RREF). Equation 3 shows that
a ratiometric configuration eliminates IB1 and IB2 from the
output equation, thus increasing the overall performance.
Equation 2 — VIN Equation for Topology #1
The PT-100 changes linearly from 100 Ohm at 0°C to
146.07 Ohm at 120°C. If desired, choose a suitable compensating resistor (RCOMP) so that VIN can be virtually 0V at any
desirable temperature. For example, if RCOMP = 100 Ohm,
then at 0°C, VIN = 0V and thus a higher gain can be used.
Equation 3 — ADC_DOUT Showing IB1 & IB2 Elimination
45
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
30169796
FIGURE 38. Topology #2: 3-wire RTD Using 1 Current Source
Figure 38 shows the second topology for a 3-wire RTD application. Topology #2 shows the same connection as topology
#1, but without IB2. Although this topology eliminates a current source, it requires two channel measurements as shown
in Equation 4.
Equation 4 — VIN Equation for Topology #2
www.national.com
46
LMP90080/LMP90079/LMP90078/LMP90077
17.6.2 Thermocouple and IC Analog Temperature
30169799
FIGURE 39. Thermocouple with CJC
The LMP900xx is also ideal for thermocouple temperature
applications. Thermocouples have several advantages that
make them popular in many industrial and medical applications. Compare to RTDs, thermistors, and IC sensors, thermocouples are the most rugged, least expensive, and can
operate over the largest temperature range.
A thermocouple is a sensor whose junction generates a differential voltage, VIN, that is relative to the temperature difference (Thot – Tcold). Thot is also known as the measuring
junction or “hot” junction, which is placed at the measured
environment. Tcold is also known as the reference or “cold”
junction, which is placed at the measuring system environment.
Because a thermocouple can only measure a temperature
difference, it does not have the ability to measure absolute
temperature. To determine the absolute temperature of the
measured environment (Thot), a technique known as cold
junction compensation (CJC) must be used.
In a CJC technique, the “cold” junction temperature, Tcold, is
sensed by using an IC temperature sensor, such as the
LM94022. The temperature sensor should be placed within
close proximity of the reference junction and should have an
isothermal connection to the board to minimize any potential
temperature gradients.
Once Tcold is obtained, use a standard thermocouple lookup-table to find its equivalent voltage. Next, measure the
differential thermocouple voltage and add the equivalent cold
junction voltage. Lastly, convert the resulting voltage to temperature using a standard thermocouple look-up-table.
For example, assume Tcold = 20°C. The equivalent voltage
from a type K thermocouple look-up-table is 0.798 mV. Next,
add the measured differential thermocouple voltage to the
Tcold equivalent voltage. For example, if the thermocouple
voltage is 4.096 mV, the total would be 0.798 mV + 4.096 mV
= 4.894 mV. Referring to the type K thermocouple table gives
a temperature of 119.37°C for 4.894 mV.
47
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
4.
18.0 Registers
1.
2.
3.
If written to, RESERVED bits must be written to only 0
unless otherwise indicated.
Read back value of RESERVED bits and registers is
unspecified and should be discarded.
Recommended values must be programmed and
forbidden values must not be programmed where they
are indicated in order to avoid unexpected results.
If written to, registers indicated as Reserved must have
the indicated default value as shown below. Any other
value can cause unexpected results.
18.1 REGISTER MAP
Register Name
ADDR
(URA & LRA)
Type
Default
RESETCN
Reset Control
0x00
WO
-
SPI_HANDSHAKECN
SPI Handshake Control
0x01
R/W
0x00
SPI_RESET
SPI Reset Control
0x02
R/W
0x00
SPI_STREAMCN
SPI Stream Control
0x03
R/W
0x00
Reserved
-
0x04 - 0x07
-
0x00
0x00
PWRCN
Power Mode Control and Status
0x08
RO &
WO
DATA_ONLY_1
Data Only Read Control 1
0x09
R/W
0x1A
DATA_ONLY_2
Data Only Read Control 2
0x0A
R/W
0x02
ADC_RESTART
ADC Restart Conversion
Reserved
-
GPIO_DIRCN
0x0B
WO
-
0x0C - 0x0D
-
0x00
GPIO Direction Control
0x0E
R/W
0x00
GPIO_DAT
GPIO Data
0x0F
RO &
WO
-
BGCALCN
Background Calibration Control
0x10
R/W
0x00
SPI_DRDYBCN
SPI Data Ready Bar Control
0x11
R/W
0x03
ADC_AUXCN
ADC Auxiliary Control
0x12
R/W
0x00
SPI_CRC_CN
CRC Control
0x13
R/W
0x02
SENDIAG_THLD
Sensor Diagnostic Threshold
0x14
R/W
0x00
Reserved
-
0x15-0x16
-
0x0000
SCALCN
System Calibration Control
0x17
R/W
0x00
ADC_DONE
ADC Data Available
0x18
RO
-
SENDIAG_FLAGS
Sensor Diagnostic Flags
0x19
RO
-
ADC_DOUT
Conversion Data 1 and 0
0x1A - 0x1B
RO
-
Reserved
-
0x1C
-
-
0x1D
RO &
WO
-
SPI_CRC_DAT
CRC Data
CHANNEL CONFIGURATION REGISTERS (CH4 to CH6 for LMP90080/LMP90079 only)
CH_STS
Channel Status
0x1E
RO
0x00
CH_SCAN
Channel Scan Mode
0x1F
R/W
0x30
CH0_INPUTCN
CH0 Input Control
0x20
R/W
0x01
CH0_CONFIG
CH0 Configuration
0x21
R/W
0x70
CH1_INPUTCN
CH1 Input Control
0X22
R/W
0x13
CH1_CONFIG
CH1 Configuration
0x23
R/W
0x70
CH2_INPUTCN
CH2 Input Control
0x24
R/W
0x25
CH2_CONFIG
CH2 Configuration
0x25
R/W
0x70
CH3_INPUTCN
CH3 Input Control
0x26
R/W
0x37
CH3_CONFIG
CH3 Configuration
0x27
R/W
0x70
CH4_INPUTCN
CH4 Input Control
0x28
R/W
0x01
CH4_CONFIG
CH4 Configuration
0x29
R/W
0x70
CH5_INPUTCN
CH5 Input Control
0x2A
R/W
0x13
CH5_CONFIG
CH5 Configuration
0x2B
R/W
0x70
www.national.com
48
ADDR
(URA & LRA)
Type
Default
CH6_INPUTCN
CH6 Input Control
0x2C
R/W
0x25
CH6_CONFIG
CH6 Configuration
0x2D
R/W
0x70
Reserved
-
0x2E - 0x2F
-
0x00
0x30 - 0x31
R/W
0x0000
0x32
-
0x00
0x33 - 0x34
R/W
0x8000
SYSTEM CALIBRATION REGISTERS
CH0_SCAL_OFFSET
CH0 System Calibration Offset Coefficients
Reserved
-
CH0_SCAL_GAIN
CH0 System Calibration Gain Coefficients
Reserved
-
0x35
-
0x00
CH0_SCAL_SCALING
CH0 System Calibration Scaling Coefficients
0x36
R/W
0x01
CH0_SCAL_BITS_SEL
ECTOR
CH0 System Calibration Bit Selector
0x37
R/W
0x00
CH1_SCAL_OFFSET
CH1 System Calibration Offset Coefficients
0x38 - 0x39
R/W
0x0000
Reserved
-
CH1_SCAL_GAIN
CH1 System Calibration Gain Coefficient
Reserved
0x3A
-
0x00
0x3B - 0x3C
R/W
0x8000
-
0x3D
-
0x00
CH1_SCAL_SCALING
CH1 System Calibration Scaling Coefficients
0x3E
R/W
0x01
CH1_SCAL_BITS_SEL
ECTOR
CH1 System Calibration Bit Selector
CH2_SCAL_OFFSET
CH2 System Calibration Offset Coefficients
Reserved
-
CH2_SCAL_GAIN
CH2 System Calibration Gain Coefficient
Reserved
-
CH2_SCAL_SCALING
CH2 System Calibration Scaling Coefficients
CH2_SCAL_BITS_SEL
ECTOR
CH2 System Calibration Bit Selector
CH3_SCAL_OFFSET
CH3 System Calibration Offset Coefficients
Reserved
-
CH3_SCAL_GAIN
CH3 System Calibration Gain Coefficient
Reserved
-
CH3_SCAL_SCALING
CH3 System Calibration Scaling Coefficients
CH3_SCAL_BITS_SEL
ECTOR
CH3 System Calibration Bit Selector
Reserved
-
0x3F
R/W
0x00
0x40 - 0x41
R/W
0x0000
0x42
-
0x00
0x43 - 0x44
R/W
0x8000
0x45
-
0x00
0x46
R/W
0x01
0x47
R/W
0x00
0x48 - 0x49
R/W
0x0000
0x4A
-
0x00
0x4B - 0x4C
R/W
0x8000
0x4D
-
0x00
0x4E
R/W
0x01
0x4F
R/W
0x00
0x50 - 0x7F
-
0x00
18.2 POWER AND RESET REGISTERS
RESETCN: Reset Control (Address 0x00)
Bit
Bit Symbol
Bit Description
Register and Conversion Reset
[7:0] REG_AND_CNV_ RST
0xC3: Register and conversion reset
Others: Neglected
49
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
Register Name
LMP90080/LMP90079/LMP90078/LMP90077
SPI_RESET: SPI Reset Control (Address 0x02)
Bit
Bit Symbol
Bit Description
SPI Reset Enable
[0]
SPI_ RST
0x0 (default): SPI Reset Disabled
0x1: SPI Reset Enabled
Note:Once Written, The contents of this register are sticky. That is, the content of this register cannot be changed with subsequent write.However, a Register reset clears the register
as well as the sticky status.
PWRCN: Power Mode Control and Status (Address 0x08)
Bit
Bit Symbol
[7:2] Reserved
Bit Description
Power Control
[1:0] PWRCN
Write Only – power down mode control
0x0: Active Mode
0x1: Power-down Mode
0x3: Stand-by Mode
Read Only – the present mode is:
0x0 (default): Active Mode
0x1: Power-down Mode
0x3: Stand-by Mode
www.national.com
50
ADC_RESTART: ADC Restart Conversion (Address 0x0B)
Bit
Bit Symbol
[7:1] Reserved
0
RESTART
Bit Description
Restart conversion
1: Restart conversion.
14.2.1. ADC_AUXCN: ADC Auxiliary Control (Address 0x12)
Bit
Bit Symbol
Bit Description
7
Reserved
-
6
RESET_SYSCAL
5
CLK_EXT_DET
4
CLK_SEL
The System Calibration registers (CHx_SCAL_OFFSET and CHx_SCAL_GAIN) are:
0 (default): preserved even when "REG_AND_CNV_ RST" = 0xC3.
1: reset by setting "REG_AND_CNV_ RST" = 0xC3.
External clock detection
0 (default): "External Clock Detection" is operational
1: "External-Clock Detection" is bypassed
Clock select – only valid if CLK_EXT_DET = 1
0 (default): Selects internal clock
1: Selects external clock
Selects RTD Current as follows:
RTD_CUR_SEL
[3:0] (LMP90080 and LMP90078
only)
0x0 (default): 0 µA
0x1: 100 µA
0x2: 200 µA
0x3: 300 µA
0x4: 400 µA
0x5: 500 µA
0x6: 600 µA
0x7: 700 µA
0x8: 800 µA
0x9: 900 µA
0xA: 1000 µA
ADC_DONE: ADC Data Available (Address 0x18)
Bit
Bit Symbol
Bit Description
Data Available – indicates if new conversion data is available
[7:0] DT_AVAIL_B
0x00 − 0xFE: Available
0xFF: Not available
51
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
18.3 ADC REGISTERS
LMP90080/LMP90079/LMP90078/LMP90077
ADC_DOUT: 16-bit Conversion Data (two’s complement) (Address 0x1A - 0x1B)
Address
Name
Register Description
0x1A
ADC_DOUTH
ADC Conversion Data [15:8]
0x1B
ADC_DOUTL
ADC Conversion Data [7:0]
0x1C
Reserved
Reserved
Note: Repeat reads of these registers are allowed as long as such reads are spaced apart by at least 72 µs.
18.4 CHANNEL CONFIGURATION REGISTERS
CH_STS: Channel Status (Address 0x1E)
Bit
Bit Symbol
[7:2] Reserved
Bit Description
Channel Scan Not Ready – indicates if it is okay to program CH_SCAN
1
CH_SCAN_NRDY
0
INV_OR_RPT_RD_STS
0: Update not pending, CH_SCAN register is okay to program
1: Update pending, CH_SCAN register is not ready to be programmed
Invalid or Repeated Read Status
0: ADC_DOUT just read was valid and hitherto unread
1: ADC_DOUT just read was either invalid (not ready) or there was a repeated read.
www.national.com
52
Bit
Bit Symbol
Bit Description
Channel Scan Select
[7:6] CH_SCAN_SEL
0x0 (default): ScanMode0: Single-Channel Continuous Conversion
0x1: ScanMode1: One or more channels Single Scan
0x2: ScanMode2: One or more channels Continuous Scan
0x3: ScanMode3: One or more channels Continuous Scan with Burnout Currents
Last channel for conversion
LAST_CH
[5:3] (CH4 to CH6 for LMP90080
and LMP90079 only)
0x0: CH0
0x1: CH1
0x2: CH2
0x3: CH3
0x4: CH4
0x5: CH5
0x6 (default): CH6
Note: LAST_CH cannot be smaller than FIRST_CH. For example, if LAST_CH = CH5, then
FIRST_CH cannot be CH6. If 0x7 is written it is ignored.
Starting channel for conversion
FIRST_CH
[2:0] (CH4 to CH6 for LMP90080
and LMP90079 only)
0x0 (default): CH0
0x1: CH1
0x2: CH2
0x3: CH3
0x4: CH4
0x5: CH5
0x6: CH6
Note: FIRST_CH cannot be greater than LAST_CH. For example, if FIRST_CH = CH1,
then LAST_CH cannot be CH0. If 0x7 is written it is ignored.
Note: While writing to the CH_SCAN register, if 0x7 is written
to FIRST_CH or LAST_CH the write to the entire CH_SCAN
register is ignored.
53
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
CH_SCAN: Channel Scan Mode (Address 0x1F)
LMP90080/LMP90079/LMP90078/LMP90077
CHx_INPUTCN: Channel Input Control (CH4 to CH6 for LMP90080/LMP90079 only)
Register Address (hex):
a. CH0: 0x20
b. CH1: 0X22
c. CH2: 0x24
d. CH3: 0x26
e. CH4: 0x28
f. CH5: 0x2A
g. CH6: 0x2C
Bit
7
Bit Symbol
BURNOUT_EN
Bit Description
Enable sensor diagnostic
0 (default): Disable Sensor Diagnostics current injection for this Channel
1: Enable Sensor Diagnostics current injection for this Channel
Select the reference
6
VREF_SEL
0 (Default): Select VREFP1 and VREFN1
1: Select VREFP2 and VREFN2
Positive input select
[5:3] VINP
0x0: VIN0
0x1: VIN1
0x2: VIN2
0x3: VIN3 (LMP90080/LMP90079 only)
0x4: VIN4 (LMP90080/LMP90079 only)
0x5: VIN5 (LMP90080/LMP90079 only)
0x6: VIN6
0x7: VIN7
Note: to see the default values for each channel, refer to the table below.
Negative input select
[2:0] VINN
0x0: VIN0
0x1: VIN1
0x2: VIN2
0x3: VIN3 (LMP90080/LMP90079 only)
0x4: VIN4 (LMP90080/LMP90079 only)
0x5: VIN5 (LMP90080/LMP90079 only)
0x6: VIN6
0x7: VIN7
Note: to see the default values for each channel, refer to the table below.
Default VINx for CH0-CH6
VINP
VINN
CH0
VIN0
VIN1
CH1
VIN2
VIN3 (LMP90080/
LMP90079 only)
CH2
VIN4 (LMP90080/ VIN5 (LMP90080/
LMP90079 only)
LMP90079 only)
CH3
VIN6
www.national.com
CH4 (LMP90080/
LMP90079 only)
VIN0
VIN1
CH5 (LMP90080/
LMP90079 only)
VIN2
VIN3
CH6 (LMP90080/
LMP90079 only)
VIN4
VIN5
VIN7
54
LMP90080/LMP90079/LMP90078/LMP90077
CHx_CONFIG: Channel Configuration (CH4 to CH6 LMP90080/LMP90079 only)
Register Address (hex):
a. CH0: 0x21
b. CH1: 0x23
c. CH2: 0x25
d. CH3: 0x27
e. CH4: 0x29
f. CH5: 0x2B
g. CH6: 0x2D
Bit
7
Bit Symbol
Bit Description
Reserved
ODR Select
[6:4] ODR_SEL
0x0: 13.42 / 8 = 1.6775 SPS
0x1: 13.42 / 4 = 3.355 SPS
0x2: 13.42 / 2 = 6.71 SPS
0x3: 13.42 SPS
0x4: 214.65 / 8 = 26.83125 SPS
0x5: 214.65 / 4 = 53.6625 SPS
0x6: 214.65 / 2 = 107.325 SPS
0x7 (default): 214.65 SPS
Gain Select
[3:1] GAIN_SEL
0x0 (default): 1 (FGA OFF)
0x1: 2 (FGA OFF)
0x2: 4 (FGA OFF)
0x3: 8 (FGA OFF)
0x4: 16 (FGA ON)
0x5: 32 (FGA ON)
0x6: 64 (FGA ON)
0x7: 128 (FGA ON)
Enable/Disable the buffer
0
BUF_EN
0 (default): Include the buffer in the signal path
1: Exclude the buffer from the signal path
Note: When gain ≥ 16, the buffer is automatically included in the signal path irrespective
of this bit.
55
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
18.5 CALIBRATION REGISTERS
BGCALCN: Background Calibration Control (Address 0x10)
Bit
Bit Symbol
Bit Description
[7:2] Reserved
Background calibration control – selects scheme for continuous background calibration.
0x0 (default): BgcalMode0: Background Calibration OFF
0x1: BgcalMode1: Offset Correction / Gain Estimation
0x2: BgcalMode2: Offset Correction / Gain Correction
0x3: BgcalMode3: Offset Estimation / Gain Estimation
[1:0] BGCALN
SCALCN: System Calibration Control (Address 0x17)
Bit
Bit Symbol
Bit Description
[7:2] Reserved
System Calibration Control
When written, set SCALCN to:
0x0 (default): Normal Mode
0x1: “System Calibration Offset Coefficient Determination” mode
0x2: “System Calibration Gain Coefficient Determination” mode
0x3: Reserved
[1:0] SCALCN
When read, this bit indicates the system calibration mode is in:
0x0: Normal Mode
0x1: "System Calibration Offset Coefficient Determination" mode
0x2: "System Calibration Gain Coefficient Determination" mode
0x3: Reserved
Note: when read, this bit will indicate the current System Calibration status. Since this coefficient determination mode will only take 1 conversion cycle, reading this register will only
return 0x00, unless this register is read within 1 conversion window.
CHx_SCAL_OFFSET: CH0-CH3 System Calibration Offset Registers (Two's-Complement)
ADDR
Name
Description
0x48
CHx_SCAL_OFFSETH
System Calibration Offset Coefficient Data [15:8]
0x49
CHx_SCAL_OFFSETM
System Calibration Offset Coefficient Data [7:0]
CH0
CH1
CH2
CH3
0x30
0x38
0x40
0x31
0x39
0x41
0x32
0x3A 0x42
0x4A Reserved
-
CHx_SCAL_GAIN: CH0-CH3 System Calibration Gain Registers (Fixed Point 1.23 Format)
ADDR
CH3
Description
CH1
0x33
0x3B 0x43
0x4B CHx_SCAL_GAINH
System Calibration Gain Coefficient Data [15:8]
0x34
0x3C 0x44
0x4C CHx_SCAL_GAINL
System Calibration Gain Coefficient Data [7:0]
0x35
0x3D 0x45
0x4D Reserved
-
www.national.com
CH2
Name
CH0
56
LMP90080/LMP90079/LMP90078/LMP90077
CHx_SCAL_SCALING: CH0-CH3 System Calibration Scaling Coefficient Registers
ADDR
CH0
CH1
CH2
0x36
0x3E 0x46
CH3
Name
Description
0x4E CHx_SCAL_SCALING
System Calibration Scaling Coefficient Data [5:0]
CHx_SCAL_BITS_SELECTOR: CH0-CH3 System Calibration Bit Selector Registers
ADDR
CH0
CH1
CH2
CH3
0x37
0x3F
0x47
0x4F
Name
Description
CHx_SCAL_BITS_SELECTOR
System Calibration Bit Selection Data [2:0]
18.6 SENSOR DIAGNOSTIC REGISTERS
SENDIAG_THLD: Sensor Diagnostic Threshold (Address 0x14)
Address
0x14
Name
Register Description
SENDIAG_THLD
Sensor Diagnostic threshold
SENDIAG_FLAGS: Sensor Diagnostic Flags (Address 0x19 )
Bit
7
Bit Symbol
SHORT_THLD_ FLAG
Bit Description
Short Circuit Threshold Flag = 1 when the absolute value of VOUT is within the absolute
threshold voltage set by the SENDIAG_THLD register.
6
RAILS_FLAG
Rails Flag = 1 when at least one of the inputs is near rail (VA or GND).
5
POR_AFT_LST_RD
Power-on-reset after last read = 1 when there was a power-on-reset event since the last
time the SENDIAG_FLAGS register was read.
Overflow flags
[4:3] OFLO_FLAGS
[2:0] SAMPLED_CH
0x0: Normal operation
0x1: The modulator was not overranged, but ADC_DOUT got clamped to 0x7f_ffff (positive
fullscale) or 0x80_0000 (negative full scale)
0x2: The modulator was over-ranged (VIN > 1.2*VREF/GAIN)
0x3: The modulator was over-ranged (VIN < -1.2*VREF/GAIN)
Channel Number – the sampled channel for ADC_DOUT and SENDIAG_FLAGS.
57
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
18.7 SPI REGISTERS
SPI_HANDSHAKECN: SPI Handshake Control (Address 0x01)
Bit
Bit Symbol
[7:4] Reserved
Bit Description
SDO/DRDYB Driver – sets who is driving the SDO/DRYB pin
Whenever CSB is
Whenever CSB is
Asserted and the Device CSB is
Asserted and the Device
is Not Reading
Deasserted
is Reading ADC_DOUT
ADC_DOUT
[3:1] SDO_DRDYB_ DRIVER
0
SW_OFF_TRG
0x0 (default)
SDO is driving
DRDYB is driving
High-Z
0x3
SDO is driving
DRDYB is driving
DRDYB is driving
0x4
SDO is driving
High-Z
High-Z
Others
Forbidden
Switch-off trigger - refers to the switching of the output drive from the slave to the master.
0 (default): SDO will be high-Z after the last (16th, 24th, 32nd, etc) rising edge of SCLK.
This option allows time for the slave to transfer control back to the master at the end of the
frame.
1: SDO’s high-Z is postponed to the subsequent falling edge following the last (16th, 24th,
32nd, etc) rising edge of SCLK. This option provides additional hold time for the last bit, DB0,
in non-streaming read transfers.
SPI_STREAMCN: SPI Streaming Control (Address 0x03)
Bit
Bit Symbol
Bit Description
Stream type
7
STRM_TYPE
[6:0] STRM_ RANGE
0 (default): Normal Streaming mode
1: Controlled Streaming mode
Stream range – selects Range for Controlled Streaming mode
Default: 0x00
DATA_ONLY_1: Data Only Read Control 1 (Address 0x09)
Bit
7
Bit Symbol
Bit Description
Reserved
Start address for the Data Only Read Transaction
[6:0] DATA_ONLY_ADR
Default: 0x1A
Please refer to the description of DT_ONLY_SZ in DATA_ONLY_2 register.
www.national.com
58
Bit
Bit Symbol
[7:3] Reserved
Bit Description
-
[2:0]
DATA_ONLY_SZ
Number of bytes to be read out in Data Only mode. A value of 0x0 means read one byte
and 0x7 means read 8 bytes.
Default: 0x2
SPI_DRDYBCN: SPI Data Ready Bar Control (Address 0x11 )
Bit
Bit Symbol
Bit Description
Enable DRDYB on D6
7
SPI_DRDYB_D6
6
Reserved
5
CRC_RST
4
Reserved
0 (default): D6 is a GPIO
1: D6 = drdyb signal
CRC Reset
0 (default): Enable CRC reset on DRDYB deassertion
1: Disbale CRC reset on DRDYB deassertion
Gain background calibration
3
FGA_BGCAL
[2:0] Reserved
0 (default): Correct FGA gain error. This is useful only if the device is operating in BgcalMode2 and ScanMode2 or ScanMode3.
1: Correct FGA gain error using the last known coefficients.
Default - 0x3 (do not change this value)
SPI_CRC_CN: CRC Control (Address 0x13 )
Bit
Bit Symbol
[7:5] Reserved
Bit Description
Enable CRC
4
EN_CRC
3
Reserved
2
DRDYB_AFT_CRC
0 (default): Disable CRC
1: Enable CRC
Default - 0x1 (do not change this value)
DRDYB After CRC
[1:0] Reserved
0 (default): DRDYB is deasserted (active high) after ADC_DOUTL is read.
1: DRDYB is deasserted after SPI_CRC_DAT (which follows ADC_DOUTL), is read.
-
59
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077
DATA_ONLY_2: Data Only Read Control 2 (Address 0x0A)
LMP90080/LMP90079/LMP90078/LMP90077
SPI_CRC_DAT: CRC Data (Address 0x1D )
Bit
Bit Symbol
Bit Description
CRC Data
[7:0] CRC_DAT
When written, this register reset CRC:
Any Value: Reset CRC
When read, this register indicates the CRC data.
18.8 GPIO REGISTERS
GPIO_DIRCN: GPIO Direction (Address 0x0E )
Bit
7
Bit Symbol
Bit Description
Reserved
GPIO direction control – these bits are used to control the direction of each General Purpose
Input/Outputs (GPIO) pins D0 - D6.
x
GPIO_DIRCNx
0 (default): Dx is an Input
1: Dx is an Output
where 0 ≤ x ≤ 6.
For example, writing a 1 to bit 6 means D6 is an Output.
Note: If D6 is used for DRDYB, then it cannot be used for GPIO.
GPIO_DAT: GPIO Data (Address 0x0F)
Bit
7
Bit Symbol
Bit Description
Reserved
Write Only - when GPIO_DIRCNx = 0
0: Dx is LO
1: Dx is HI
Read Only - when GPIO_DIRCNx = 1
x
Dx
0: Dx driven LO
1: Dx driven HI
where 0 ≤ x ≤ 6.
For example, writing a 0 to bit 4 means D4 is LO.
It is okay to Read the GPIOs that are configured as outputs and write to GPIOs that are
configured as inputs. Reading the GPIOs that are outputs would return the current value
on those GPIOs, and writing to the GPIOs that are inputs are neglected.
www.national.com
60
LMP90080/LMP90079/LMP90078/LMP90077
19.0 Physical Dimensions inches (millimeters) unless otherwise noted
28-Lead Molded Plastic TSSOP
Order Number LMP90080MH/NOPB, LMP90079MH/NOPB, LMP90078MH/NOPB, LMP90077MH/NOPB
NS Package Number MO-153
61
www.national.com
LMP90080/LMP90079/LMP90078/LMP90077 Sensor AFE System: Multi-Channel, Low-Power 16Bit Sensor AFE with True Continuous Background Calibration
Notes
For more National Semiconductor product information and proven design tools, visit the following Web sites at:
www.national.com
Products
Design Support
Amplifiers
www.national.com/amplifiers
WEBENCH® Tools
www.national.com/webench
Audio
www.national.com/audio
App Notes
www.national.com/appnotes
Clock and Timing
www.national.com/timing
Reference Designs
www.national.com/refdesigns
Data Converters
www.national.com/adc
Samples
www.national.com/samples
Interface
www.national.com/interface
Eval Boards
www.national.com/evalboards
LVDS
www.national.com/lvds
Packaging
www.national.com/packaging
Power Management
www.national.com/power
Green Compliance
www.national.com/quality/green
Switching Regulators
www.national.com/switchers
Distributors
www.national.com/contacts
LDOs
www.national.com/ldo
Quality and Reliability
www.national.com/quality
LED Lighting
www.national.com/led
Feedback/Support
www.national.com/feedback
Voltage References
www.national.com/vref
Design Made Easy
www.national.com/easy
www.national.com/powerwise
Applications & Markets
www.national.com/solutions
Mil/Aero
www.national.com/milaero
PowerWise® Solutions
Serial Digital Interface (SDI) www.national.com/sdi
Temperature Sensors
www.national.com/tempsensors SolarMagic™
www.national.com/solarmagic
PLL/VCO
www.national.com/wireless
www.national.com/training
PowerWise® Design
University
THE CONTENTS OF THIS DOCUMENT ARE PROVIDED IN CONNECTION WITH NATIONAL SEMICONDUCTOR CORPORATION
(“NATIONAL”) PRODUCTS. NATIONAL MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY
OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES TO
SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME WITHOUT NOTICE. NO LICENSE, WHETHER EXPRESS,
IMPLIED, ARISING BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS
DOCUMENT.
TESTING AND OTHER QUALITY CONTROLS ARE USED TO THE EXTENT NATIONAL DEEMS NECESSARY TO SUPPORT
NATIONAL’S PRODUCT WARRANTY. EXCEPT WHERE MANDATED BY GOVERNMENT REQUIREMENTS, TESTING OF ALL
PARAMETERS OF EACH PRODUCT IS NOT NECESSARILY PERFORMED. NATIONAL ASSUMES NO LIABILITY FOR
APPLICATIONS ASSISTANCE OR BUYER PRODUCT DESIGN. BUYERS ARE RESPONSIBLE FOR THEIR PRODUCTS AND
APPLICATIONS USING NATIONAL COMPONENTS. PRIOR TO USING OR DISTRIBUTING ANY PRODUCTS THAT INCLUDE
NATIONAL COMPONENTS, BUYERS SHOULD PROVIDE ADEQUATE DESIGN, TESTING AND OPERATING SAFEGUARDS.
EXCEPT AS PROVIDED IN NATIONAL’S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NATIONAL ASSUMES NO
LIABILITY WHATSOEVER, AND NATIONAL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO THE SALE
AND/OR USE OF NATIONAL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR
PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY
RIGHT.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR
SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL
COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein:
Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected
to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness.
National Semiconductor and the National Semiconductor logo are registered trademarks of National Semiconductor Corporation. All other
brand or product names may be trademarks or registered trademarks of their respective holders.
Copyright© 2011 National Semiconductor Corporation
For the most current product information visit us at www.national.com
National Semiconductor
Americas Technical
Support Center
Email: [email protected]
Tel: 1-800-272-9959
www.national.com
National Semiconductor Europe
Technical Support Center
Email: [email protected]
National Semiconductor Asia
Pacific Technical Support Center
Email: [email protected]
National Semiconductor Japan
Technical Support Center
Email: [email protected]