Power Distribution & Terminal Blocks PDB Power Distribution Blocks 600Vac/dc Catalog Symbol: Power Distribution Blocks Voltage Rating: 600 Vac/dc maximum SCCR: 10kA (except for select products noted) Agency Information: UL Recognized, Guide XCFR2, File E221592 CSA Certified, Class 6228-01, File 15364 Example: A 3-pole, 16023 series is 16023-3. The line side of the device has (1) conductor opening per pole that accepts 350kcmil - #6 CU/AL. The load side of the device has (6) conductor openings per pole that each accepts #4 - #14 CU or #4 - #12 AL. Power Distribution Blocks (600V) Catalog Data 2-Pole -2 -2 -2 -2 -2 -2 -2 -2 3-Pole -3 -3 -3 -3 -3 -3 -3 -3 4-Pole -4 -4 NA NA NA NA NA NA 16335 -1 -2 -3 NA 500kcmil - #6CU-AL 16370* 16371* -1 -1 -2 -2 -3 -3 NA NA 350kcmil - #6CU-AL 350kcmil - #6CU-AL 16372 16373 -1 -1 -2 -2 -3 -3 NA NA 350kcmil - #6CU-AL 350kcmil - #6CU-AL 16375 16376 -1 -1 -2 -2 -3 -3 NA NA 600kcmil - #2CU-AL 600kcmil - #2CU-AL 16377 16528 -1 -1 -2 -2 -3 -3 NA NA (2)300kcmil - #4CU-AL (2) 600kcmil - #2CU-AL 16530 16541 -1 –1 -2 -2 -3 –3 NA NA (2) 500kcmil - #6CU-AL 500kcmil - #6CU-AL Load (6) #4 - #14CU, #4 - #8AL (6) #4 - #14CU, #4 - #12AL (4) #4 - #14CU, #4 - #8AL (6) #4 - #14CU, #4 - #8AL (6) #4 - #14CU, #4 - #12AL (6) #4 - #14CU, #4 - #8AL (6 )#2 - #14CU, #2 - #12AL (3) #2 - #14CU, #2 - #8AL (2) 1/0 - #14CU, 1/0 - #8AL (3) #2 - #14 CU, #2 - #8AL (2) 1/0 - #14CU, 1/0 - #8AL (12) #4 - #14CU, #4 - #12AL (6) #2 - #14CU, #2 - #8AL (3) 1/0 - #14CU, 1/0 - #8AL (21) #10 - #14CU, #10AL (3) 1/0 - #14CU-AL (14) #10 - #14CU, #10AL (12) #4 - #14CU, #4 - #12AL (6) #2 - #14CU, #2 -8AL (3) 1/0 - #14CU, 1/0 - #8AL (12) #4 - #14CU, #4 - #12AL (4) 3/0 - #6CU-AL (4) #4 - #14CU-AL (12) #4 - #14CU-AL (21) #6 - #14CU-AL *SCCR up to 200kA. See additional information on data sheet #1049. How To Order: Catalog Number + # of Poles Example: 16021-3 (complete part number) Dimensional information on page 3 Optional covers: 1011 SB004093 160 162 163 165 Series: Series: Series: Series: CPB160 - (pole) CPB162 - (pole) CPDB - (pole) CPDB165 (1 for each pole) Page 1 of 3 Data Sheet 1117 Connector Material and Ampacity AL-175A AL-310A AL-175A AL-175A AL-310A AL-350A AL-380A AL-310A CSA 1-Pole NA NA -1 -1 -1 -1 -1 -1 Connection Line 2/0 - #14CU, 2/0 - #8AL 350kcmil - #6CU-AL 2/0 - #14CU, 2/0 - #8AL 2/0 - #14CU, 2/0 - #8AL 350kcmil - #6CU-AL (2) 2/0 - #14CU, 2/0 - #8AL 500kcmil - #6CU-AL 350kcmil - #6CU-AL UL Catalog Number 16021 16023 16220* 16321* 16323* 16325 16330 16332 • • • • • • • • • • • • • • • • AL-380A • • AL-310A AL-310A • • • • AL-310A AL-310A • • • • AL-420A AL-420A • • • • AL-570A AL-840A • • • • AL-760A AL-380A • • • • Power Distribution & Terminal Blocks PDB Splicer Terminal Blocks 600Vac/dc Catalog Symbol: Splicer Terminal Blocks Voltage Rating: 600Vac/dc maximum SCCR: 10kA (except for select products noted) Agency Information: UL Recognized, Guide XCFR2, File E221592 CSA Certified, Class 6228-01, File 15364 Picture shown: 3-Pole - 1 opening on line per phase 1 opening on load per phase Connection 1-Pole 2-Pole 3-Pole 4-Pole Line 16000 16003 16005 16200 16201 16204* 16301 16303 16306 16500 16504 NA NA NA -1 -1 -1 -1 -1 -1 -1 -1 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -2 -3 -3 -3 -3 -3 -3 -3 -3 -3 -3 -3 -4 -4 -4 NA NA NA NA NA NA NA NA 2/0 - #8CU-AL 250kcmil - #6CU Only 350kcmil - #6CU-AL #2 - #14CU, #2 - #8AL 1/0 - #14CU Only 2/0 - #8CU-AL 250kcmil - #6CU Only 350kcmil - #6CU-AL (1)500kcmil - #6CU-AL (2) 350kcmil - #4CU-AL (2) 500kcmil - #6CU-AL Load Connector Material and Ampacity CSA Catalog Number UR Power Distribution Blocks (600V) Catalog Data 2/0 - #8CU-AL 250kcmil - #6CU Only 350kcmil - #6CU-AL #2 - #14CU, #2 - #8AL 1/0 - #14CU Only 2/0 - #8CU-AL 250kcmil - #6CU Only 350kcmil - #6CU-AL (1)500kcmil - #6CU-AL (2) 350kcmil - #4CU-AL (2) 500kcmil - #6CU-AL AL-175A CU-255A AL-310A AL-115A CU-150A AL-175A CU-255A AL-310A AL-380A AL-620A AL-760A • • • • • • • • • • • — — — — — — • • • • • *SCCR up to 200kA. See additional information on data sheet #1049. Dimensional information on page 3 Optional covers: 1011 SB004093 160 162 163 165 Series: Series: Series: Series: CPB160 - (pole) CPB162 - (pole) CPDB - (pole) CPDB165 (1 for each pole) Page 2 of 3 Data Sheet 1117 Power Distribution & Terminal Blocks PDB Connector-Stud and Stud-Stud Blocks 600Vac/dc Catalog Symbol: Connector–Stud Block Voltage Rating: 600Vac/dc maximum SCCR: 10kA (except for select products noted) Agency Information: UL Recognized, Guide XCFR2, File E221592 CSA Certified, Class 6228-01, File 15364 Series 162, 163, and 165 Dimensional Data (Available 1, 2, and 3 pole) H J Series 160 (Available 2, 3, and 4 pole) Dimensional Data 2.12" LINE SIDE D LINE SIDE 0.5" C 0.69" F E E 4.12" (2-Pole) 5.37" (3-Pole) 6.62" (4-Pole) 3.62" (2-Pole) 4.87" (3-Pole) 6.12" (4-Pole) .25" A B L C'Bore 2.8" G 1" 2.0" K Dia. 1.4" LOAD SIDE 0.38" 0.27" Dia. (2 Holes) Slot 0.22" x 0.38". (4 Places) Dimensions for Series 162, 163, and 165 LOAD SIDE 160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165) have mounting holes within barriers–see dimensional drawings. Cat. No. A B 162 163 165 2.88 4.0 5.5 2.25 3.38 4.75 C1 C2 1.07 1.88 1.98 3.60 3.10” 5.79” C3 D E 2.70 1.75 5.21 3.32 8.48” 2.93” 0.81 1.62 2.69 F G H J K L 0.53 0.31 0.84 0.31 0.20 0.41 0.99 0.31 0.87 0.35 Slot .20” wide x .41” long Slot .42” wide x .62” long 1.55” 0.38 1.19” .44” Slot .20” wide x .33” long Slot .41” wide x .53” long 1-Pole 2-Pole 3-Pole Connection Line Load Connector Material and Ampacity CSA Catalog Number UL Connector-Stud Blocks (600V) Catalog Data Connector – Stud 16280* -1 -2 -3 2/0 - #14CU-AL ⁄Ω¢ - 20 ≈ ‹Ω¢ Stud AL-175A • — 16281 -1 -2 -3 2/0 - #14CU-AL ⁄Ω¢ - 20 Tapped hole AL-175A • — 16378 -1 -2 -3 500kcmil - #6CU-AL (2) ⁄Ω¢ - 20 ≈ 1 Stud AL-380A • • 16383 -1 -2 -3 500kcmil - #6CU-AL (1) ‹Ω• - 16 ≈ 1 Stud AL-380A • • 16582 -1 -2 -3 (2) 500kcmil - #6CU-AL (2) ‹Ω• - 16 ≈ 1fiΩ• Stud AL-760A • • 16290 -1 -2 -3 ⁄Ω¢ - 20 ≈ ‹Ω¢ Stud ⁄Ω¢ - 20 ≈ ‹Ω¢ Stud CU-150A • — 16390 -1 -2 -3 ‹Ω• - 16 ≈ 1⁄Ω• Stud ‹Ω• - 16 ≈ 1⁄Ω• Stud CU-250A • • 16394 -1 -2 -3 ⁄Ω™ - 13 ≈ 1⁄Ω¡§ Stud ⁄Ω™ - 13 ≈ 1⁄Ω¡§ Stud CU-400A • • 16395 -1 -2 -3 ‹Ω• - 16 ≈ 1‡Ω¡§ Stud (2) ⁄Ω¢ - 20 ≈ ·Ω¡§ Stud CU-310A • • 16591 -1 -2 -3 ‹Ω• - 16 ≈ 1‡Ω¡§ Stud (2) ‹Ω• - 16 ≈ 1‡Ω¡§ Stud CU-400A • — 16593 -1 -2 -3 ⁄Ω™ - 13 ≈ 1 Stud ⁄Ω™ - 13 ≈ 1 Stud CU-600A • • Stud – Stud *SCCR up to 200kA The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. © 2011 Cooper Bussmann www.cooperbussmann.com 1011 SB04093 Page 3 of 3 Data Sheet 1117